Optometer (ophthalmic instrument)

Last updated

The optometer was a device used for measuring the necessary spherical and/or cylindrical corrections to be prescribed for eyeglasses, from the middle of the 18th century until around 1922, when modern instruments were developed. [1] [2] [3] The term, coined in 1738 by W. Porterfield to describe his Scheiner slit optometer, [4] and used for 200 years to describe many different inventions to measure refractive error of the eye, has completely fallen out of usage today as the task of measuring eyes for spectacles is done with modern instruments, such as the phoropter.

Contents

"Phoropter" is one of several generic names for modern instruments containing an optometer for each eye (battery of lenses for determination of optical error), combined with prisms and other attachments for measuring binocularity. The term refractor is another such term, and "vision tester" or other descriptive terms are used because "phoroptor", spelled with "-or", is a trademark of one company. [5]

Greens' Refractor, 1934 to 1978 Greens' refractor 001.jpg
Greens' Refractor, 1934 to 1978

Examples of optometers


The modern phoropter or refractor

A modern phoropter made by Reichert Reichert Phoropter 2025.jpg
A modern phoropter made by Reichert

In the middle of the 19th century, doctors tested for optical error using single hand-held lenses, held one at a time in front of the patient's eye, or in a trial frame. A wooden case with dozens or hundreds of lenses was held on the doctor's lap, or in a case near the patient's chair, as he or she examined the patient.

In the later part of the 19th century, the United States, Germany, France and the UK were actively inventing numerous mechanical optometers, to speed up the process of bringing lenses before the patients' eyes. Various patented or unpatented optometers were sold throughout the later 19th and the start of the 20th centuries, some containing rotating batteries of lenses in various arrangements, usually with the name of the inventor at the front.

Around 1910, binocularity was tested using trial frames which sat on the patient's face or on a support bar, with extra testing devices added to the front of the frames, such as Maddox rods, rotating prisms, and phorometers. The refraction part of the exam was done with trial lenses that fit into the back of the same trial frame. Optometer was the generic name for devices, crude and simple, with rotating batteries of sphere and cylinder lenses placed in front of each eye, one at a time; so there was no testing for binocularity. When the optometer and phorometer were combined into single instruments, the modern refractor/phoropter was born. This happened in the middle 1910s when two companies in the New York City area began to market competing versions. [12]

A third US company, Bausch & Lomb, joined the competition in 1934, while the other 2 made improvements. Around that time, many companies in Europe and Asia began making phoropters of their own design, as well as copying American models.

See also

Related Research Articles

<span class="mw-page-title-main">Binoculars</span> Pair of telescopes mounted side-by-side

Binoculars or field glasses are two refracting telescopes mounted side-by-side and aligned to point in the same direction, allowing the viewer to use both eyes when viewing distant objects. Most binoculars are sized to be held using both hands, although sizes vary widely from opera glasses to large pedestal-mounted military models.

<span class="mw-page-title-main">Esotropia</span> Form of strabismus in which the eyes turn inward

Esotropia is a form of strabismus in which one or both eyes turn inward. The condition can be constantly present, or occur intermittently, and can give the affected individual a "cross-eyed" appearance. It is the opposite of exotropia and usually involves more severe axis deviation than esophoria. Esotropia is sometimes erroneously called "lazy eye", which describes the condition of amblyopia; a reduction in vision of one or both eyes that is not the result of any pathology of the eye and cannot be resolved by the use of corrective lenses. Amblyopia can, however, arise as a result of esotropia occurring in childhood: In order to relieve symptoms of diplopia or double vision, the child's brain will ignore or "suppress" the image from the esotropic eye, which when allowed to continue untreated will lead to the development of amblyopia. Treatment options for esotropia include glasses to correct refractive errors, the use of prisms, orthoptic exercises, or eye muscle surgery.

<span class="mw-page-title-main">Cooke triplet</span> Patented photographic lens system designed by Dennis Taylor

The Cooke triplet is a photographic lens designed and patented in 1893 by Dennis Taylor who was employed as chief engineer by T. Cooke & Sons of York. It was the first lens system that allowed the elimination of most of the optical distortion or aberration at the outer edge of the image.

<span class="mw-page-title-main">Farsightedness</span> Eye condition in which light is focused behind instead of on the retina

Far-sightedness, also known as long-sightedness, hypermetropia, and hyperopia, is a condition of the eye where distant objects are seen clearly but near objects appear blurred. This blur is due to incoming light being focused behind, instead of on, the retina due to insufficient accommodation by the lens. Minor hypermetropia in young patients is usually corrected by their accommodation, without any defects in vision. But, due to this accommodative effort for distant vision, people may complain of eye strain during prolonged reading. If the hypermetropia is high, there will be defective vision for both distance and near. People may also experience accommodative dysfunction, binocular dysfunction, amblyopia, and strabismus. Newborns are almost invariably hypermetropic, but it gradually decreases as the newborn gets older.

<span class="mw-page-title-main">Eyeglass prescription</span> Order written by an eyewear prescriber

An eyeglass prescription is an order written by an eyewear prescriber, such as an optometrist, that specifies the value of all parameters the prescriber has deemed necessary to construct and/or dispense corrective lenses appropriate for a patient. If an eye examination indicates that corrective lenses are appropriate, the prescriber generally provides the patient with an eyewear prescription at the conclusion of the exam.

<span class="mw-page-title-main">Amblyopia</span> Failure of the brain to process input from one eye

Amblyopia, also called lazy eye, is a disorder of sight in which the brain fails to fully process input from one eye and over time favors the other eye. It results in decreased vision in an eye that typically appears normal in other aspects. Amblyopia is the most common cause of decreased vision in a single eye among children and younger adults.

<span class="mw-page-title-main">Visual acuity</span> Clarity of vision

Visual acuity (VA) commonly refers to the clarity of vision, but technically rates an animal's ability to recognize small details with precision. Visual acuity depends on optical and neural factors. Optical factors of the eye influence the sharpness of an image on its retina. Neural factors include the health and functioning of the retina, of the neural pathways to the brain, and of the interpretative faculty of the brain.

<span class="mw-page-title-main">Refractive surgery</span> Surgery to treat common vision disorders

Refractive surgery is an optional eye surgery used to improve the refractive state of the eye and decrease or eliminate dependency on glasses or contact lenses. This can include various methods of surgical remodeling of the cornea (keratomileusis), lens implantation or lens replacement. The most common methods today use excimer lasers to reshape the curvature of the cornea. Refractive eye surgeries are used to treat common vision disorders such as myopia, hyperopia, presbyopia and astigmatism.

<span class="mw-page-title-main">Eye examination</span> Series of tests assessing vision and pertaining to the eyes

An eye examination, commonly known as an eye test, is a series of tests performed to assess vision and ability to focus on and discern objects. It also includes other tests and examinations of the eyes. Eye examinations are primarily performed by an optometrist, ophthalmologist, or an orthoptist. Health care professionals often recommend that all people should have periodic and thorough eye examinations as part of routine primary care, especially since many eye diseases are asymptomatic. Typically, a healthy individual who otherwise has no concerns with their eyes receives an eye exam once in their 20s and twice in their 30s.

<span class="mw-page-title-main">Slit lamp</span> Device for examining the eye

In ophthalmology and optometry, a slit lamp is an instrument consisting of a high-intensity light source that can be focused to shine a thin sheet of light into the eye. It is used in conjunction with a biomicroscope. The lamp facilitates an examination of the anterior segment and posterior segment of the human eye, which includes the eyelid, sclera, conjunctiva, iris, natural crystalline lens, and cornea. The binocular slit-lamp examination provides a stereoscopic magnified view of the eye structures in detail, enabling anatomical diagnoses to be made for a variety of eye conditions. A second, hand-held lens is used to examine the retina.

<span class="mw-page-title-main">Ophthalmoscopy</span> Part of an eye examination

Ophthalmoscopy, also called funduscopy, is a test that allows a health professional to see inside the fundus of the eye and other structures using an ophthalmoscope. It is done as part of an eye examination and may be done as part of a routine physical examination. It is crucial in determining the health of the retina, optic disc, and vitreous humor.

<span class="mw-page-title-main">Autorefractor</span> Type of optical machine

An autorefractor or automated refractor is a computer-controlled machine used during an eye examination to provide an objective measurement of a person's refractive error and prescription for glasses or contact lenses. This is achieved by measuring how light is changed as it enters a person's eye.

<span class="mw-page-title-main">Phoropter</span> Ophthalmic testing device

A phoropter or refractor is an ophthalmic testing device. It is commonly used by eye care professionals during an eye examination, and contains different lenses used for refraction of the eye during sight testing, to measure an individual's refractive error and determine their eyeglass prescription. It also is used to measure the patients' phorias and ductions, which are characteristics of binocularity.

<span class="mw-page-title-main">Astigmatism</span> Type of eye defect

Astigmatism is a type of refractive error due to rotational asymmetry in the eye's refractive power. This results in distorted or blurred vision at any distance. Other symptoms can include eyestrain, headaches, and trouble driving at night. Astigmatism often occurs at birth and can change or develop later in life. If it occurs in early life and is left untreated, it may result in amblyopia.

Aniseikonia is an ocular condition where there is a significant difference in the perceived size of images. It can occur as an overall difference between the two eyes, or as a difference in a particular meridian. If the ocular image size in both eyes are equal, the condition is known as iseikonia.

<span class="mw-page-title-main">Lensmeter</span> Ophthalmic instrument mainly used by optometrists and opticians

A lensmeter or lensometer (sometimes even known as focimeter or vertometer), is an optical instrument used in ophthalmology. It is mainly used by optometrists and opticians to measure the back or front vertex power of a spectacle lens and verify the correct prescription in a pair of eyeglasses, to properly orient and mark uncut lenses, and to confirm the correct mounting of lenses in spectacle frames. Lensmeters can also verify the power of contact lenses, if a special lens support is used.

<span class="mw-page-title-main">Gholam A. Peyman</span> Iranian-American ophthalmologist and retina surgeon known for inventing LASIK eye surgery

Gholam A. Peyman is an Iranian American ophthalmologist, retina surgeon, and inventor. He is best known for his invention of LASIK eye surgery, a vision correction procedure designed to allow people to see clearly without glasses. He was awarded the first US patent for the procedure in 1989.

The Bagolini striated glasses test, or BSGT, is a subjective clinical test to detect the presence or extent of binocular functions and is generally performed by an optometrist or orthoptist or ophthalmologist. It is mainly used in strabismus clinics. Through this test, suppression, microtropia, diplopia and manifest deviations can be noted. However this test should always be used in conjunction with other clinical tests, such as Worth 4 dot test, Cover test, Prism cover test and Maddox rod to come to a diagnosis.

<span class="mw-page-title-main">Ophthalmic trial frame</span> Tool used in eye examination

A trial frame is a tool used by ophthalmic professionals like ophthalmologists and optometrists. It is basically an adjustable spectacle frame with multiple cells, used to hold corrective lenses, and other accessories in subjective refraction and retinoscopy.

<span class="mw-page-title-main">Jackson cross cylinder</span> Ophthalmic instrument

The Jackson cross cylinder (JCC) is an instrument used by ophthalmologists, orthoptists and optometrists in their routine eye examination, particularly in determination of corrective lens power in patients with astigmatism. It is also used for testing near point of the eye.

References

  1. "The Modern Phorometer," 1917, Henry DeZeng, self-published, Camden New Jersey
  2. "Instructions for L. A. Berteling's Compound Optometer," 1885, L. A. Berteling, George Spaulding & Co. San Francisco
  3. "Ein Neues Optometer," 1863, Karl Burow, Berlin
  4. "Thomas Young's Contribution to Visual Optics", Journal of Vision, Oct 14, 2010, David A. Atchison and W. Neil Charman.
  5. "Visual Optics and Refraction" by David D. Michaels, Mosby 1980, p. 232
  6. U.S. Patent Office
  7. "Instructions for L. A. Berteling's Compound Optometer," 1885, L. A. Berteling, George Spaulding & Co. San Francisco, p. 17
  8. "Instructions for L. A. Berteling's Compound Optometer," 1885, L. A. Berteling, George Spaulding & Co. San Francisco, p. 16
  9. "The Modern Phorometer," 1917, Henry DeZeng, self-published, Camden New Jersey, p.26
  10. "The Modern Phorometer," 1917, Henry DeZeng, self-published, Camden New Jersey, p 46
  11. "The Modern Phorometer," 1917, Henry DeZeng, self-published, Camden New Jersey, frontispiece
  12. phoropter