Oxygen permeability

Last updated

Oxygen permeability (OP) is a parameter of a contact lens that expresses the ability of the lens to let oxygen reach the eye by diffusion. In soft contact lenses, it is dependent on the thickness of the lens and the material of the lens, especially concerning the water content. Because of this dependence on thickness, transmissibility level (abbreviated Dk/t), the Dk per thickness of the lens, is more commonly used.

Contents

The earliest models of soft contact lenses, based on hydrogel material, had a level of oxygen permeability of around 6–8 Dk/t. [1] Polymacon, the material used in the first hydrogel contact lenses in some countries in the 1960s and approved by the FDA in the U.S. in 1971, has a Dk of 9 .

These days, typical values of oxygen permeability for hydrogel contact lenses range from 25 to 50. For example, Nelfilcon A has a Dk value of 26, and the Omafilcon A has a Dk of 25.

While those numbers are typical of hydrogel contact lenses, many contact lenses are made of silicone hydrogel, which has a much higher oxygen permeability. For example, the Dk value of Lotrafilcon B and Comfilcon A, two silicone hydrogels, is 110 and 128, respectively. These values are more than twice the values of oxygen permeability for hydrogel materials.

D being diffusivity (cm2/sec) – a measure of how fast the oxygen moves through the material. Note, different sources may use different units: contact package inserts often use cm2/sec, while academic papers may use other values for distance such as mm2/sec.

k being the solubility (ml O2/ml of material × mm Hg) – a measure of how much oxygen is contained in the material. Once again, various sources may use units of different sizes. Do not assume that they're the same unless specified by the source.

See also

Related Research Articles

<span class="mw-page-title-main">Bausch & Lomb</span> Canadian eye health company

Bausch + Lomb is an eye health products company based in Vaughan, Ontario, Canada. It is one of the world's largest suppliers of contact lenses, lens care products, pharmaceuticals, intraocular lenses, and other eye surgery products. The company was founded in Rochester, New York, in 1853 by optician John Bausch and cabinet maker turned financial backer Henry Lomb. Until its sale in 2013, Bausch + Lomb was one of the oldest continually operating companies in the United States.

<span class="mw-page-title-main">Corrective lens</span> Type of lens

A corrective lens is a lens that is typically worn in front of the eye to improve daily vision. The most common use is to treat refractive errors: myopia, hypermetropia, astigmatism, and presbyopia. Glasses or "spectacles" are worn on the face a short distance in front of the eye. Contact lenses are worn directly on the surface of the eye. Intraocular lenses are surgically implanted most commonly after cataract removal but can be used for purely refractive purposes.

<span class="mw-page-title-main">Contact lens</span> Lenses placed on the eyes surface

Contact lenses, or simply contacts, are thin lenses placed directly on the surface of the eyes. Contact lenses are ocular prosthetic devices used by over 150 million people worldwide, and they can be worn to correct vision or for cosmetic or therapeutic reasons. In 2010, the worldwide market for contact lenses was estimated at $6.1 billion, while the US soft lens market was estimated at $2.1 billion. Multiple analysts estimated that the global market for contact lenses would reach $11.7 billion by 2015. As of 2010, the average age of contact lens wearers globally was 31 years old, and two-thirds of wearers were female.

The focal length of an optical system is a measure of how strongly the system converges or diverges light; it is the inverse of the system's optical power. A positive focal length indicates that a system converges light, while a negative focal length indicates that the system diverges light. A system with a shorter focal length bends the rays more sharply, bringing them to a focus in a shorter distance or diverging them more quickly. For the special case of a thin lens in air, a positive focal length is the distance over which initially collimated (parallel) rays are brought to a focus, or alternatively a negative focal length indicates how far in front of the lens a point source must be located to form a collimated beam. For more general optical systems, the focal length has no intuitive meaning; it is simply the inverse of the system's optical power.

Permeability in fluid mechanics and the Earth sciences is a measure of the ability of a porous material to allow fluids to pass through it.

<span class="mw-page-title-main">Hydrogel</span> Soft water-rich polymer gel

A hydrogel is a biphasic material, a mixture of porous, permeable solids and at least 10% by weight or volume of interstitial fluid composed completely or mainly by water. In hydrogels the porous permeable solid is a water insoluble three dimensional network of natural or synthetic polymers and a fluid, having absorbed a large amount of water or biological fluids. These properties underpin several applications, especially in the biomedical area. Many hydrogels are synthetic, but some are derived from nature. The term 'hydrogel' was coined in 1894.

Orthokeratology, also referred to as Night lenses, Ortho-K, OK, Overnight Vision Correction, Corneal Refractive Therapy (CRT), Accelerated Orthokeretology, Cornea Corrective Contacts, Eccentricity Zero Molding, and Gentle Vision Shaping System (GVSS), is the use of gas-permeable contact lenses that temporarily reshape the cornea to reduce refractive errors such as myopia, hyperopia, and astigmatism.

<span class="mw-page-title-main">Acuvue</span>

Acuvue is a brand of disposable contact lenses made in Jacksonville Florida and Limerick-based Vistakon, a subsidiary of Johnson & Johnson (J&J).

In science and engineering, hydraulic conductivity, is a property of porous materials, soils and rocks, that describes the ease with which a fluid can move through the pore space, or fractures network. It depends on the intrinsic permeability of the material, the degree of saturation, and on the density and viscosity of the fluid. Saturated hydraulic conductivity, Ksat, describes water movement through saturated media. By definition, hydraulic conductivity is the ratio of volume flux to hydraulic gradient yielding a quantitative measure of a saturated soil's ability to transmit water when subjected to a hydraulic gradient.

Moisture vapor transmission rate (MVTR), also water vapor transmission rate (WVTR), is a measure of the passage of water vapor through a substance. It is a measure of the permeability for vapor barriers.

<span class="mw-page-title-main">Silicone rubber</span> Elastomer

Silicone rubber is an elastomer composed of silicone—itself a polymer—containing silicon together with carbon, hydrogen, and oxygen. Silicone rubbers are widely used in industry, and there are multiple formulations. Silicone rubbers are often one- or two-part polymers, and may contain fillers to improve properties or reduce cost.

In physics and engineering, permeation is the penetration of a permeate through a solid. It is directly related to the concentration gradient of the permeate, a material's intrinsic permeability, and the materials' mass diffusivity. Permeation is modeled by equations such as Fick's laws of diffusion, and can be measured using tools such as a minipermeameter.

<span class="mw-page-title-main">Units of textile measurement</span> Systems for measuring textiles

Textile fibers, threads, yarns and fabrics are measured in a multiplicity of units.

<span class="mw-page-title-main">Corneal neovascularization</span> Medical condition

Corneal neovascularization (CNV) is the in-growth of new blood vessels from the pericorneal plexus into avascular corneal tissue as a result of oxygen deprivation. Maintaining avascularity of the corneal stroma is an important aspect of corneal pathophysiology as it is required for corneal transparency and optimal vision. A decrease in corneal transparency causes visual acuity deterioration. Corneal tissue is avascular in nature and the presence of vascularization, which can be deep or superficial, is always pathologically related.

<span class="mw-page-title-main">Pellucid marginal degeneration</span> Degenerative corneal condition

Pellucid marginal degeneration (PMD) is a degenerative corneal condition, often confused with keratoconus. It typically presents with painless vision loss affecting both eyes. Rarely, it may cause acute vision loss with severe pain due to perforation of the cornea. It is typically characterized by a clear, bilateral thinning (ectasia) in the inferior and peripheral region of the cornea, although some cases affect only one eye. The cause of the disease remains unclear.

KeraSoft is a patented range of soft and silicone hydrogel contact lenses designed to manage the condition of irregular corneas including keratoconus. They are marketed as an alternative to rigid gas-permeable lenses, offering improved comfort and longer wearing times.

<span class="mw-page-title-main">Effects of long-term contact lens wear on the cornea</span> Overview of the effects of long-term contact lens wear on the cornea

Long-term contact lens use can lead to alterations in corneal thickness, stromal thickness, curvature, corneal sensitivity, cell density, and epithelial oxygen uptake, etc. Other changes may include the formation of epithelial vacuoles and microcysts as well as the emergence of polymegethism in the corneal endothelium. Decreased corneal sensitivity, vision loss, and photophobia have also been observed in patients who have worn contact lenses for an extended period of time. Many contact lens-induced changes in corneal structure are reversible if contact lenses are removed for an extended period of time.

The aim of an accurate intraocular lens power calculation is to provide an intraocular lens (IOL) that fits the specific needs and desires of the individual patient. The development of better instrumentation for measuring the eye's axial length (AL) and the use of more precise mathematical formulas to perform the appropriate calculations have significantly improved the accuracy with which the surgeon determines the IOL power.

<span class="mw-page-title-main">Ophthalmic drug administration</span>

Ophthalmic drug administration is the administration of a drug to the eyes, most typically as an eye drop formulation. Topical formulations are used to combat a multitude of diseased states of the eye. These states may include bacterial infections, eye injury, glaucoma, and dry eye. However, there are many challenges associated with topical delivery of drugs to the cornea of the eye.

References

  1. "Oxygen permeability". lenses-contact.co.uk.