This article needs additional citations for verification .(July 2023) |
A 600 series connector is an obsolete three-pin connector with up to six conductors.
It was for many years the standard telephone service connector in Australia, used on rural party lines and the national Postmaster-General's Department (later Telstra) landline network, but has since the 1970s been superseded by the six position modular connector in this application. As of 2008 [update] a large installed base remained and a large variety of connectors, adapters and equipment such as ADSL filters were still in production and readily available.
It has no other common or standard use, either within Australia or beyond. However it is manufactured in other countries, usually in China, for export to Australia.
The 600 series plug has up to three flat pins plus a non-conducting spigot, which ensures correctly oriented insertion. Each pin carries up to two conductors by means of two contacts, one on each side of the pin. The pin bodies are of a non-conductive plastic material.
The original series 600 plugs and sockets were designed to be equally suitable for fixed wall mounting or for use on flexible cords. Such connectors are still available, but specialised fixed and line versions also exist. [1]
Standard three pin six conductor. Often now replaced by a modular 6P2C connector and an adaptor; In particular, this combination is now the most common connector supplied with new equipment in Australia.
The non-conducting spigot of the original 605 plug was provided with a hole for a countersunk screw, allowing the plug to be fixed in a wall-mounted socket. Removal then required first removing the socket cover, to allow this retaining screw to be removed. In this way a semi-permanent connection, requiring tools for disconnection, could be achieved.
Standard six conductor.
The original 610 socket was provided with two mounting holes, one behind the receptacle for the plug spigot, and both for countersunk screws. This arrangement allowed the socket to be secured using two screws, with no plug inserted, or alternatively with the plug inserted, using the same two mounting holes but with one of the screws passing through the spigot to secure the plug as well.
Similar to 610, but with the contacts of pairs one and two allowed to connect when no plug is inserted, contact 1 connecting to 2 and 5 to 6.
This is particularly designed for mode 3 connection. The incoming line to the mode 3 device is connected using pair one, and pair two is used as the outgoing line to other devices. If the mode 3 device is unplugged, the switch contacts maintain line connection to the other devices.
This function is not generally supported by modular connectors. Modular connectors providing suitable switch contacts are available but not common; Instead, mode 3 devices use two modular connectors, one for the incoming line and the other for the outgoing line. The convenience of using a single connector in this application is one reason for the continued use of 600 series connectors, but mixing this wiring scheme with modular connectors does not work well. For example, if a modern modem with its supplied 6P2C adaptor is plugged into a conventionally wired 611 mode 3 socket, the result is to disconnect all downstream devices.
In some sockets conductors 3 and 4 also connect when no plug is present, shorting pair three. Sockets are also available with cams to allow the switching functions to be selectively enabled as required. In some older sockets this could be achieved by simply bending the contacts; The cams merely implement this useful accidental feature in an intentional fashion.
Many recent 611 sockets have a stepped recess for the plug spigot, to accept a plug with a larger spigot but still provide a good fit for a standard 605 plug. Equipment requiring mode 3 connection can then be equipped with these larger spigot plugs, to prevent this equipment being connected to a 610 socket which does not provide mode 3 support. These plugs are common on older fax machines and modems, and used on some security and similar equipment. These plugs were also used on Telex machines within Australia.
In general, 60x where x is any numeric other than 0 or 5 indicates a non-standard plug. Compatibility and designs vary from maker to maker.
In general, 61x where x is any numeric other than 0 or 1 indicates a non-standard socket. Compatibility and designs vary from maker to maker.
Extension leads are generally four conductor, including pair one and one other pair, wired straight through pin to pin. Some incorporate an adaptor plug which includes a 610 socket, often with all six conductors connected, allowing the extension to also serve as a double adaptor.
Double adaptors are almost always six conductor, wired pin to pin, with a 605 plug and two 610 sockets in parallel.
A mode 3 adaptor appears physically to be a double adaptor, but the sockets are one 610 and one 611, with pair one of the 610 wired to pair two of the 611, and pair one of the 611 to pair one of the plug. Treatment of the other conductors varies, and may be assignable.
The conductors are numbered 1–6 from the end further from the spigot. The contact terminals are normally labelled with their numbers on rewireable plugs and sockets.
Use of pair one is almost always to standard, but pairs two and three may not be present, or the conductors may be used for other purposes. Pair two is often used for local power supply or other proprietary purposes. Adaptors to modular connectors may connect only pair one, or pairs one and two, or all six conductors.
Modems and other equipment supplied in Australia are nowadays normally provided with a modular plug, and an adaptor which connects only pair one, allowing the modular plug to be used with a 610 or 611 socket in need. The pin carrying pair three is often missing completely from the plugs of these adaptors.
Legacy installations and equipment most often use either:
In the early 1980s Telecom would install multiple phone sockets in premises as requested, but charged a rental fee per socket, to cover installation and maintenance. In this era the ringing tone was generated by electro-mechanical bells in each phone and with pulse dialling then in use, the 6xx series plugs and sockets supported separation of the bell circuit. This was to avoid a bell tinkling noise during dialling, from any on-hook phones in the circuit. The standard multi-extension wiring in residential premises thus used 3 wires of the 4 wire cable. White was wired to pins 2 and 3 which were bridged by a link in each socket. Red (bell circuit) was connect to pin 5 and blue was connected to pin 6. The black wire was unused and left unconnected in the socket. Electro-mechanical phones such as the 800 series had their internal wiring slightly adjusted to support such multiple extension use.
When phones moved to electronic ringers and tone dialling, the additional socket wiring using pins 3 and 5 was no longer needed for suppression and the use of only pair one, with white on pin 2 and blue on pin 6 became the standard socket wiring, until being superseded by the modular connector.
All connection schemes connect pair one to the centre two connectors on the modular connector.
This is the most common scheme, connecting only pair one:
The pin carrying contacts 3 and 4 is generally completely absent from these adaptors, as are the contacts 1 and 5. Equipment such as handsets, modems and extension bells sold in or for use in Australia often arrives packaged with one of these adaptors.
This is common in extension cables, many of which have built-in adaptors to 6P4C (and more rarely to 6P6C). There are several conflicting schemes, some using pair two in addition to one, others one and three. As most applications use only pair one, most users are unaware of the potential problem.
Even if no modular connector is included in an extension cable, most 600 series extension cables are four conductor. Pair one is always connected, and either pair two or three.
A common connection scheme is:
Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor. An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit, or between different electrical circuits, thereby joining them into a larger circuit.
A phone connector is a family of cylindrically-shaped electrical connectors primarily for analog audio signals. Invented in the late 19th century for telephone switchboards, the phone connector remains in use for interfacing wired audio equipment, such as headphones, speakers, microphones, mixing consoles, and electronic musical instruments. A male connector, is mated into a female connector, though other terminology is used.
A registered jack (RJ) is a standardized telecommunication network interface for connecting voice and data equipment to a computer service provided by a local exchange carrier or long distance carrier. Registered interfaces were first defined in the Universal Service Ordering Code (USOC) system of the Bell System in the United States for complying with the registration program for customer-supplied telephone equipment mandated by the Federal Communications Commission (FCC) in the 1970s. Subsequently, in 1980 they were codified in title 47 of the Code of Federal Regulations Part 68. Registered jack connections began to see use after their invention in 1973 by Bell Labs. The specification includes physical construction, wiring, and signal semantics. Accordingly, registered jacks are primarily named by the letters RJ, followed by two digits that express the type. Additional letter suffixes indicate minor variations. For example, RJ11, RJ14, and RJ25 are the most commonly used interfaces for telephone connections for one-, two-, and three-line service, respectively. Although these standards are legal definitions in the United States, some interfaces are used worldwide.
A DC connector is an electrical connector that supplies direct current (DC) power.
A power cord, line cord, or mains cable is an electrical cable that temporarily connects an appliance to the mains electricity supply via a wall socket or extension cord. The terms are generally used for cables using a power plug to connect to a single-phase alternating current power source at the local line voltage. The terms power cable, mains lead, flex or kettle lead are also used. A lamp cord is a light-weight, ungrounded, single-insulated two-wire cord used for small loads such as a table or floor lamp.
AC power plugs and sockets connect devices to mains electricity to supply them with electrical power. A plug is the connector attached to an electrically-operated device, often via a cable. A socket is fixed in place, often on the internal walls of buildings, and is connected to an AC electrical circuit. Inserting the plug into the socket allows the device to draw power from this circuit.
A telephone jack and a telephone plug are electrical connectors for connecting a telephone set or other telecommunications apparatus to the telephone wiring inside a building, establishing a connection to a telephone network. The plug is inserted into its counterpart, the jack, which is commonly affixed to a wall or baseboard. The standards for telephone jacks and plugs vary from country to country, though the 6P2C style modular plug has become by far the most common type.
TAE is the German standard for telephone plugs and sockets.
A banana connector is a single-wire electrical connector used for joining wires to equipment. The term 4 mm connector is also used, especially in Europe, although not all banana connectors will mate with 4 mm parts, and 2 mm banana connectors exist. Various styles of banana plug contacts exist, all based on the concept of spring metal applying outward force into the unsprung cylindrical jack to produce a snug fit with good electrical conductivity. Common types include: a solid pin split lengthwise and splayed slightly, a tip of four leaf springs, a cylinder with a single leaf spring on one side, a bundle of stiff wire, a central pin surrounded by a multiple-slit cylinder with a central bulge, or simple sheet spring metal rolled into a nearly complete cylinder. The plugs are frequently used to terminate patch cords for electronic test equipment such as laboratory power supply units, while sheathed banana plugs are common on multimeter probe leads.
IEC 60309 is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes". They are also referred to as "pin & sleeve" connectors in North America or as "CeeForm" connectors in the entertainment industry. The maximum voltage allowed by the standard is 1000 V DC or AC; the maximum current, 800 A; and the maximum frequency, 500 Hz. The ambient temperature range is −25 °C to 40 °C.
Industrial and multiphase plugs and sockets provide a connection to the electrical mains rated at higher voltages and currents than household plugs and sockets. They are generally used in polyphase systems, with high currents, or when protection from environmental hazards is required. Industrial outlets may have weatherproof covers, waterproofing sleeves, or may be interlocked with a switch to prevent accidental disconnection of an energized plug. Some types of connectors are approved for hazardous areas such as coal mines or petrochemical plants, where flammable gas may be present.
In telecommunications, structured cabling is building or campus cabling infrastructure that consists of a number of standardized smaller elements called subsystems. Structured cabling components include twisted pair and optical cabling, patch panels and patch cables.
NEMA connectors are power plugs and sockets used for AC mains electricity in North America and other countries that use the standards set by the US National Electrical Manufacturers Association. NEMA wiring devices are made in current ratings from 15 to 60 amperes (A), with voltage ratings from 125 to 600 volts (V). Different combinations of contact blade widths, shapes, orientations, and dimensions create non-interchangeable connectors that are unique for each combination of voltage, electric current carrying capacity, and grounding system.
A stage pin connector, also known as a grounded stage pin (GSP), grounded pin connector (GPC) or theater paddle (TP), is a standard cable type for theatrical lighting in North America and in many countries in the theatre world.
A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.
British telephone sockets were introduced in their current plug and socket form on 19 November 1981 by British Telecom to allow subscribers to connect their own telephones. The connectors are specified in British Standard BS 6312. Electrical characteristics of the telephone interface are specified by individual network operators, e.g. in British Telecom's SIN 351. Electrical characteristics required of British telephones used to be specified in BS 6305.
Many different electrical connectors have been used to connect microphones to audio equipment—including PA systems, radios, tape recorders, and numerous other devices.
ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).
Plugs and sockets for electrical appliances not hardwired to mains electricity originated in the United Kingdom in the 1870s and were initially two-pin designs. These were usually sold as a mating pair, but gradually de facto and then official standards arose to enable the interchange of compatible devices. British standards have proliferated throughout large parts of the former British Empire.
There are approximately 20 types in common use around the world, such as AC power plugs and sockets, and many obsolete socket types which are still found in older buildings.