Intravoxel incoherent motion (IVIM) imaging is a concept and a method initially introduced and developed by Le Bihan et al. [1] [2] to quantitatively assess all the microscopic translational motions that could contribute to the signal acquired with diffusion MRI. In this model, biological tissue contains two distinct environments: molecular diffusion of water in the tissue (sometimes referred to as 'true diffusion'), and microcirculation of blood in the capillary network (perfusion). The concept introduced by D. Le Bihan is that water flowing in capillaries (at the voxel level) mimics a random walk (“pseudo-diffusion” [2] ) (Fig.1), as long as the assumption that all directions are represented in the capillaries (i.e. there is no net coherent flow in any direction) is satisfied.
It is responsible for a signal attenuation in diffusion MRI, which depends on the velocity of the flowing blood and the vascular architecture. Similarly to molecular diffusion, the effect of pseudodiffusion on the signal attenuation depends on the b value. However, the rate of signal attenuation resulting from pseudodiffusion is typically an order of magnitude greater than molecular diffusion in tissues, so its relative contribution to the diffusion-weighted MRI signal becomes significant only at very low b values, allowing diffusion and perfusion effects to be separated. [2] [3]
In the presence of the magnetic field gradient pulses of a diffusion MRI sequence, the MRI signal gets attenuated due to diffusion and perfusion effects. In a simple model, this signal attenuation, S/So, can be written as: [2]
where is the volume fraction of incoherently flowing blood in the tissue (“flowing vascular volume”), the signal attenuation from the IVIM effect and is the signal attenuation from molecular diffusion in the tissue.
Assuming blood water flowing in the randomly oriented vasculature changes several times direction (at least 2) during the measurement time (model 1), one has for :
where is the diffusion-sensitization of the MRI sequence, is the sum of the pseudo-diffusion coefficient associated to the IVIM effect and , the diffusion coefficient of water in blood:
where is the mean capillary segment length and is the blood velocity. [2] [4]
If blood water flows without changing direction (either because flow is slow or measurement time is short) while capillary segments are randomly and isotropically oriented (model 2), becomes:
where is a parameter linked to the gradient pulse amplitude and time course (similar to the b value). [2] [4]
In both cases, the perfusion effect results in a curvature of the diffusion attenuation plot towards b=0 (Fig.2).
In a simple approach and under some approximations, the ADC calculated from 2 diffusion-weighted images acquired with b0=0 and b1, as ADC = ln(S(b0)/S (b1)), is: [2] [4]
where is the tissue diffusion coefficient. The ADC thus only depends on the flowing vascular volume (tissue vascularity) and not on the blood velocity and capillary geometry, which is a strong advantage. The contribution of perfusion to the ADC is larger when using small b values. On the other hand, set of data obtained from images acquired with a multiple b values can be fitted with Eq.[1] using either model 1 (Eq.[2,3]) or model 2(Eq.[4]) to estimate and/or blood velocity. The late part of the curve (towards high b values, generally above 1000 s/mm²) also presents some degree of curvature (Fig.2). This is because diffusion in biological tissues is not free (Gaussian), but can be hindered by many obstacles (in particular cell membranes) or even restricted (i.e. intracellular). Several models have been proposed to describe this curvature at higher b-values, mainly the “biexponential” model which assumes the presence of 2 water compartments with fast and slow diffusion [5] [6] (where neither compartment is the from IVIM), the relative 'fast' and 'slow' labels referring to restricted and hindered diffusion, rather than pseudodiffusion/perfusion and true (hindered) diffusion. Another alternative is the “kurtosis” model which quantifies the deviation from free (Gaussian) diffusion in the parameter (Eq. [7]). [7] [8]
Biexponential model:
Where and are the relative fractions and diffusion coefficients of the fast and slow compartments. This general formulation of a biexponential decay of diffusion-weighted imaging signal with b-value can be used for IVIM, which requires sampling of low b-values (<100 s/mm²) to capture pseudodiffusion decay, or for restriction imaging, which requires higher b-value acquisitions (>1000 s/mm²) to capture restricted diffusion.
Kurtosis model:
where is the tissue intrinsic diffusion coefficient and the Kurtosis parameter (deviation from Gaussian diffusion). Both models can be related assuming some hypotheses about the tissue structure and the measurement conditions. Separation of perfusion from diffusion requires good signal-to-noise ratios [9] [10] and there are some technical challenges to overcome (artifacts, influence of other bulk flow phenomena, etc.). [3] [11] [12] Also the “perfusion” parameters accessible with the IVIM method somewhat differs from the “classical” perfusion parameters obtained with tracer methods: “Perfusion” can be seen with the physiologist eyes (blood flow) or the radiologist eyes (vascular density). [13] [14] Indeed, there is room to improve the IVIM model and understand better its relationship with the functional vascular architecture and its biological relevance.
IVIM MRI was initially introduced to evaluate perfusion and produce maps of brain perfusion, for brain activation studies (before the introduction of BOLD fMRI) and clinical applications (stroke, brain tumors). [10] [15] [16] [17] [18] [19] Recent work has proven the validity of the IVIM concept from fMRI, with an increase in the IVIM perfusion parameters in brain activated regions, and the potential of the approach to aid in our understanding of the different vascular contributions to the fMRI signal. [20] [21] [22] [23] IVIM MRI has also been used in the context of fMRI in a negative way.
A limitation of BOLD fMRI is its spatial resolution, as flow increase in somewhat large arteries or veins feed or drain large neuronal territories. By inserting “diffusion” gradient pulses in the MRI sequence (corresponding to low b-values), one may crush the contribution of the largest vessels (with high D* values associated with fast flow) in the BOLD signal and improve the spatial resolution of the activation maps. [24] [25] [26] [27] [28] Several groups have relied on this trick, though not always considering referring to the IVIM concept. This IVIM concept has also been borrowed to improve other applications, for instance, arterial spin labeling (ASL) [29] [30] or to suppress signal from extracellular flowing fluid in perfused cell systems. [31] [32]
However, IVIM MRI has recently undergone a striking revival for applications not in the brain, but throughout the body as well. [33] Following earlier encouraging results in the kidneys, [34] [35] [36] or even the heart, [37] IVIM MRI really took off for liver applications. For instance, Luciani et al. [38] found that D* was significantly reduced in cirrhotic patients, which, according to the IVIM model, points out to reduce blood velocity (and flow). (Another theoretical, rather unlikely interpretation would be that capillary segments become longer or more straight in those patients with liver fibrosis). The perfusion fraction, f, which is linked to blood volume in the IVIM model, remained normal, confirming earlier results by Yamada et al. [39] Though, blood volume is expected to be reduced in liver cirrhosis.
One has to keep in mind that IVIM imaging has a differential sensitivity to vessel types, according to the range of motion sensitization (b values) which are used. [40] [41] Signal from large vessels with rapid flow disappears quickly with very low b values, while smaller vessels with slower flow might still contribute to the IVIM signal acquired with b values larger than 200 s/mm². It has also been shown that the parameter f, often related to perfusion fraction, is sensitive to differential spin-spin relaxation rates in the two model compartments (blood/tissue) and can thus be overestimated in highly perfused tissue. [42] Correction of this effect is achieved by additional images at a different echo time. [43] Many more applications are now under investigation, especially for imaging of patients suspected of cancer in the body (prostate, liver, kidney, pancreas, etc.) [12] and human placenta. [44] [45] A key feature of IVIM diffusion MRI is that it does not involve contrast agents, and it may appear as an interesting alternative for perfusion MRI in some patients at risk for Nephrogenic Systemic Fibrosis (NSF).
Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to form pictures of the anatomy and the physiological processes of the body. MRI scanners use strong magnetic fields, magnetic field gradients, and radio waves to generate images of the organs in the body. MRI does not involve X-rays or the use of ionizing radiation, which distinguishes it from computed tomography (CT) and positron emission tomography (PET) scans. MRI is a medical application of nuclear magnetic resonance (NMR) which can also be used for imaging in other NMR applications, such as NMR spectroscopy.
Perfusion is the passage of fluid through the circulatory system or lymphatic system to an organ or a tissue, usually referring to the delivery of blood to a capillary bed in tissue. Perfusion may also refer to fixation via perfusion, used in histological studies. Perfusion is measured as the rate at which blood is delivered to tissue, or volume of blood per unit time per unit tissue mass. The SI unit is m3/(s·kg), although for human organs perfusion is typically reported in ml/min/g. The word is derived from the French verb "perfuser" meaning to "pour over or through". All animal tissues require an adequate blood supply for health and life. Poor perfusion (malperfusion), that is, ischemia, causes health problems, as seen in cardiovascular disease, including coronary artery disease, cerebrovascular disease, peripheral artery disease, and many other conditions.
Diffusion-weighted magnetic resonance imaging is the use of specific MRI sequences as well as software that generates images from the resulting data that uses the diffusion of water molecules to generate contrast in MR images. It allows the mapping of the diffusion process of molecules, mainly water, in biological tissues, in vivo and non-invasively. Molecular diffusion in tissues is not random, but reflects interactions with many obstacles, such as macromolecules, fibers, and membranes. Water molecule diffusion patterns can therefore reveal microscopic details about tissue architecture, either normal or in a diseased state. A special kind of DWI, diffusion tensor imaging (DTI), has been used extensively to map white matter tractography in the brain.
Magnetic resonance elastography (MRE) is a form of elastography that specifically leverages MRI to quantify and subsequently map the mechanical properties of soft tissue. First developed and described at Mayo Clinic by Muthupillai et al. in 1995, MRE has emerged as a powerful, non-invasive diagnostic tool, namely as an alternative to biopsy and serum tests for staging liver fibrosis.
In magnetic resonance, a spin echo or Hahn echo is the refocusing of spin magnetisation by a pulse of resonant electromagnetic radiation. Modern nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) make use of this effect.
During nuclear magnetic resonance observations, spin–lattice relaxation is the mechanism by which the longitudinal component of the total nuclear magnetic moment vector (parallel to the constant magnetic field) exponentially relaxes from a higher energy, non-equilibrium state to thermodynamic equilibrium with its surroundings (the "lattice"). It is characterized by the spin–lattice relaxation time, a time constant known as T1.
Kenneth Kin Man Kwong is a Hong Kong-born American nuclear physicist. He is a pioneer in human brain imaging. He received his bachelor's degree in Political Science in 1972 from the University of California, Berkeley. He went on to receive his Ph.D. in physics from the University of California, Riverside studying photon-photon collision interactions.
Functional magnetic resonance imaging (fMRI) of the spinal cord is an adaptation of the fMRI method that has been developed for use in the brain. Although the basic principles underlying the methods are the same, spinal fMRI requires a number of specific adaptations to accommodate the periodic motion of the spinal cord, the small cross-sectional dimensions and length of the spinal cord, and the fact that the magnetic field that is used for MRI varies with position in the spinal cord because of magnetic susceptibility differences between bone and tissues. Spinal fMRI has been used to produce maps of neuronal activity at most levels of the spinal cord in response to various stimuli, such as touch, vibration, and thermal changes, and with motor tasks. Research applications of spinal fMRI to date include studies of normal sensory and motor function, and studies of the effects of trauma and multiple sclerosis on the spinal cord.
Susceptibility weighted imaging (SWI), originally called BOLD venographic imaging, is an MRI sequence that is exquisitely sensitive to venous blood, hemorrhage and iron storage. SWI uses a fully flow compensated, long echo, gradient recalled echo (GRE) pulse sequence to acquire images. This method exploits the susceptibility differences between tissues and uses the phase image to detect these differences. The magnitude and phase data are combined to produce an enhanced contrast magnitude image. The imaging of venous blood with SWI is a blood-oxygen-level dependent (BOLD) technique which is why it was referred to as BOLD venography. Due to its sensitivity to venous blood SWI is commonly used in traumatic brain injuries (TBI) and for high resolution brain venographies but has many other clinical applications. SWI is offered as a clinical package by Philips and Siemens but can be run on any manufacturer's machine at field strengths of 1.0 T, 1.5 T, 3.0 T and higher.
The physics of magnetic resonance imaging (MRI) concerns fundamental physical considerations of MRI techniques and technological aspects of MRI devices. MRI is a medical imaging technique mostly used in radiology and nuclear medicine in order to investigate the anatomy and physiology of the body, and to detect pathologies including tumors, inflammation, neurological conditions such as stroke, disorders of muscles and joints, and abnormalities in the heart and blood vessels among others. Contrast agents may be injected intravenously or into a joint to enhance the image and facilitate diagnosis. Unlike CT and X-ray, MRI uses no ionizing radiation and is, therefore, a safe procedure suitable for diagnosis in children and repeated runs. Patients with specific non-ferromagnetic metal implants, cochlear implants, and cardiac pacemakers nowadays may also have an MRI in spite of effects of the strong magnetic fields. This does not apply on older devices, and details for medical professionals are provided by the device's manufacturer.
Quantitative Susceptibility Mapping (QSM) provides a novel contrast mechanism in Magnetic Resonance Imaging (MRI) different from traditional Susceptibility Weighted Imaging. The voxel intensity in QSM is linearly proportional to the underlying tissue apparent magnetic susceptibility, which is useful for chemical identification and quantification of specific biomarkers including iron, calcium, gadolinium, and super paramagnetic iron oxide (SPIO) nano-particles. QSM utilizes phase images, solves the magnetic field to susceptibility source inverse problem, and generates a three-dimensional susceptibility distribution. Due to its quantitative nature and sensitivity to certain kinds of material, potential QSM applications include standardized quantitative stratification of cerebral microbleeds and neurodegenerative disease, accurate gadolinium quantification in contrast enhanced MRI, and direct monitoring of targeted theranostic drug biodistribution in nanomedicine.
Magnetic resonance imaging of the brain uses magnetic resonance imaging (MRI) to produce high quality two-dimensional or three-dimensional images of the brain and brainstem as well as the cerebellum without the use of ionizing radiation (X-rays) or radioactive tracers.
Perfusion MRI or perfusion-weighted imaging (PWI) is perfusion scanning by the use of a particular MRI sequence. The acquired data are then post-processed to obtain perfusion maps with different parameters, such as BV, BF, MTT and TTP.
Synthetic MRI is a simulation method in Magnetic Resonance Imaging (MRI), for generating contrast weighted images based on measurement of tissue properties. The synthetic (simulated) images are generated after an MR study, from parametric maps of tissue properties. It is thereby possible to generate several contrast weightings from the same acquisition. This is different from conventional MRI, where the signal acquired from the tissue is used to generate an image directly, often generating only one contrast weighting per acquisition. The synthetic images are similar in appearance to those normally acquired with an MRI scanner.
The history of magnetic resonance imaging (MRI) includes the work of many researchers who contributed to the discovery of nuclear magnetic resonance (NMR) and described the underlying physics of magnetic resonance imaging, starting early in the twentieth century. MR imaging was invented by Paul C. Lauterbur who developed a mechanism to encode spatial information into an NMR signal using magnetic field gradients in September 1971; he published the theory behind it in March 1973.
An MRI sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance.
Arterial spin labeling (ASL), also known as arterial spin tagging, is a magnetic resonance imaging technique used to quantify cerebral blood perfusion by labelling blood water as it flows throughout the brain. ASL specifically refers to magnetic labeling of arterial blood below or in the imaging slab, without the need of gadolinium contrast. A number of ASL schemes are possible, the simplest being flow alternating inversion recovery (FAIR) which requires two acquisitions of identical parameters with the exception of the out-of-slice saturation; the difference in the two images is theoretically only from inflowing spins, and may be considered a 'perfusion map'. The ASL technique was developed by Alan P. Koretsky, Donald S. Williams, John A. Detre and John S. Leigh Jr in 1992.
Denis Le Bihan is a medical doctor, physicist, member of the Institut de France, member of the French Academy of Technologies and director since 2007 of NeuroSpin, an institution of the Atomic Energy and Alternative Energy Commission (CEA) in Saclay, dedicated to the study of the brain by magnetic resonance imaging (MRI) with a very high magnetic field. Denis Le Bihan has received international recognition for his outstanding work, introducing new imaging methods, particularly for the study of the human brain, as evidenced by the many international awards he has received, such as the Gold Medal of the International Society of Magnetic Resonance in Medicine (2001), the coveted Lounsbery Prize, the Louis D. Prize from the Institut de France, the prestigious Honda Prize (2012), the Louis-Jeantet Prize (2014), the Rhein Foundation Award (2021). His work has focused on the introduction, development and application of highly innovative methods, notably diffusion MRI.
Hyperpolarized 129Xe gas magnetic resonance imaging (MRI) is a medical imaging technique used to visualize the anatomy and physiology of body regions that are difficult to image with standard proton MRI. In particular, the lung, which lacks substantial density of protons, is particularly useful to be visualized with 129Xe gas MRI. This technique has promise as an early-detection technology for chronic lung diseases and imaging technique for processes and structures reliant on dissolved gases. 129Xe is a stable, naturally occurring isotope of xenon with 26.44% isotope abundance. It is one of two Xe isotopes, along with 131Xe, that has non-zero spin, which allows for magnetic resonance. 129Xe is used for MRI because its large electron cloud permits hyperpolarization and a wide range of chemical shifts. The hyperpolarization creates a large signal intensity, and the wide range of chemical shifts allows for identifying when the 129Xe associates with molecules like hemoglobin. 129Xe is preferred over 131Xe for MRI because 129Xe has spin 1/2, a longer T1, and 3.4 times larger gyromagnetic ratio (11.78 MHz/T).
Hyperpolarized gas MRI, also known as hyperpolarized helium-3 MRI or HPHe-3 MRI, is a medical imaging technique that uses hyperpolarized gases to improve the sensitivity and spatial resolution of magnetic resonance imaging (MRI). This technique has many potential applications in medicine, including the imaging of the lungs and other areas of the body with low tissue density.
{{cite book}}
: |journal=
ignored (help){{cite journal}}
: CS1 maint: multiple names: authors list (link){{cite journal}}