Luer taper

Last updated
A syringe with a male Luer-Lock fitting, and a needle with female Luer-Lock fitting (purple) which screws into it Syringe and hypodermic.jpg
A syringe with a male Luer-Lock fitting, and a needle with female Luer-Lock fitting (purple) which screws into it

The Luer taper is a standardized system of small-scale fluid fittings used for making leak-free connections between a male-taper fitting and its mating female part on medical and laboratory instruments, including hypodermic syringe tips and needles or stopcocks and needles. Currently ISO 80369 governs the Luer standards and testing methods. [1]

Contents

History

Named after the Lüer family who founded the medical instrument maker Maison Lüer in Paris, the two piece syringe was invented by either the employed instrument maker Karl Schneider [2] or Jeanne Lüer together with the glass blower Fournier. [3] It was patented by Jeanne's husband Hermann Wülfing Lüer in 1894, with international patents taken out in the following years. It originated as a 6% taper fitting for glass bottle stoppers (so one side is 1.72 degrees from the centerline). Key features of Luer taper connectors are defined in the ISO 80369-7 standards. [4] It is also defined in the DIN and EN standard 1707:1996 [5] and 20594-1:1993. [6] In 1930, Fairleigh S. Dickinson of Becton Dickinson, which had exclusive rights of marketing the Luer-syringe in the United States of America since 1898, patented the "Luer-Lok [7] ", a steel fitting that secures the needle to the syringe. [3]

Variants

There are two varieties of Luer taper connections: locking and slipping. [8] Their trade names are confusingly similar to the nonproprietary names. "Luer-Lok" and "Luer-slip" are registered trademarks of Becton Dickinson. "Luer-Lok" style connectors are often generically referred to as "luer lock" (always in lower case), while "luer-slip" style connectors may be generically referred to as "slip tip". Luer lock fittings are securely joined by means of a tabbed hub on the female fitting which screws into threads in a sleeve on the male fitting. The Luer lock fitting was developed in the United States by Fairleigh S. Dickinson. 'Luer lock' style connectors are divided into two types "one piece luer lock" and "two piece luer lock" or "rotating collar luer lock". One piece Luer lock comes as a single mold, and locking is achieved by rotating the entire luer connector or system. In two piece luer lock, a free rotating collar with threads is assembled to the luer and the locking is achieved by rotating the collar.

Slip tip (Luer-slip) fittings simply conform to Luer taper dimensions and are pressed together and held by friction (they have no threads). Luer components are manufactured from either metal or plastic and are available from many companies worldwide.

See also

Record connector, older standard for non-needle small diameter connections in Europe. [9]

Related Research Articles

A flange is a protruded ridge, lip or rim, either external or internal, that serves to increase strength ; for easy attachment/transfer of contact force with another object ; or for stabilizing and guiding the movements of a machine or its parts. Flanges are often attached using bolts in the pattern of a bolt circle.

<span class="mw-page-title-main">Syringe</span> Medical injection device

A syringe is a simple reciprocating pump consisting of a plunger that fits tightly within a cylindrical tube called a barrel. The plunger can be linearly pulled and pushed along the inside of the tube, allowing the syringe to take in and expel liquid or gas through a discharge orifice at the front (open) end of the tube. The open end of the syringe may be fitted with a hypodermic needle, a nozzle or tubing to direct the flow into and out of the barrel. Syringes are frequently used in clinical medicine to administer injections, infuse intravenous therapy into the bloodstream, apply compounds such as glue or lubricant, and draw/measure liquids. There are also prefilled syringes.

<span class="mw-page-title-main">Vacutainer</span> Type of blood collection equipment for medical testing

A vacutainer blood collection tube is a sterile glass or plastic test tube with a colored rubber stopper creating a vacuum seal inside of the tube, facilitating the drawing of a predetermined volume of liquid. Vacutainer tubes may contain additives designed to stabilize and preserve the specimen prior to analytical testing. Tubes are available with a safety-engineered stopper, with a variety of labeling options and draw volumes. The color of the top indicates the additives in the vial.

<span class="mw-page-title-main">Ferrule</span> Ring used for fastening or joining

A ferrule is any of a number of types of objects, generally used for fastening, joining, sealing, or reinforcement. They are often narrow circular rings made from metal, or less commonly, plastic. Ferrules are also often referred to as eyelets or grommets within the manufacturing industry.

<span class="mw-page-title-main">Hypodermic needle</span> Device to inject substances into the circulatory system

A hypodermic needle, one of a category of medical tools which enter the skin, called sharps, is a very thin, hollow tube with one sharp tip. It is commonly used with a syringe, a hand-operated device with a plunger, to inject substances into the body or extract fluids from the body. Large-bore hypodermic intervention is especially useful in catastrophic blood loss or treating shock.

<span class="mw-page-title-main">Screw thread</span> Helical structure used to convert between rotational and linear movement or force

A screw thread, often shortened to thread, is a helical structure used to convert between rotational and linear movement or force. A screw thread is a ridge wrapped around a cylinder or cone in the form of a helix, with the former being called a straight thread and the latter called a tapered thread. A screw thread is the essential feature of the screw as a simple machine and also as a threaded fastener.

<span class="mw-page-title-main">Machine taper</span>

A machine taper is a system for securing cutting tools or toolholders in the spindle of a machine tool or power tool. A male member of conical form fits into the female socket, which has a matching taper of equal angle.

Taper may refer to:

A dry enema is an alternative technique for cleansing the human rectum either for reasons of health, or for sexual hygiene. It is accomplished by squirting a small amount of sterile lubricant into the rectum, resulting in a bowel movement more quickly and with less violence than can be achieved by an oral laxative.

<span class="mw-page-title-main">Hose coupling</span> Connector on the end of a hose

A hose coupling is a connector on the end of a hose to connect it with another hose or with a tap or a hose appliance, such as an irrigation sprinkler. It is usually made of steel, brass, stainless steel, aluminium or plastic.

<span class="mw-page-title-main">Needle remover</span> Medical device

A needle remover is a device used to physically remove a needle from a syringe. In developing countries, there is still a need for improvements in needle safety in hospital settings as most of the needle removal processes are done manually and under severe risk of hazard from needles puncturing skin risking infection. These countries cannot afford needles with individual safety devices attached, so needle-removers must be used to remove the needle from the syringe. This lowers possible pathogen spread by preventing the reuse of the syringes, reducing incidents of accidental needle-sticks, and facilitating syringe disposal.

<span class="mw-page-title-main">Plug valve</span>

Plug valves are valves with cylindrical or conically tapered "plugs" which can be rotated inside the valve body to control flow through the valve. The plugs in plug valves have one or more hollow passageways going sideways through the plug, so that fluid can flow through the plug when the valve is open. Plug valves are simple and often economical.

<span class="mw-page-title-main">Piping and plumbing fitting</span> Connecting pieces in pipe systems

A fitting or adapter is used in pipe systems to connect straight sections of pipe or tube, adapt to different sizes or shapes, and for other purposes such as regulating fluid flow. These fittings are used in plumbing to manipulate the conveyance of water, gas, or liquid waste in domestic or commercial environments, within a system of pipes or tubes.

<span class="mw-page-title-main">Ground glass joint</span> Used in laboratories to easily assemble apparatus from parts

Ground glass joints are used in laboratories to quickly and easily fit leak-tight apparatus together from interchangeable commonly available parts. For example, a round bottom flask, Liebig condenser, and oil bubbler with ground glass joints may be rapidly fitted together to reflux a reaction mixture. This is a large improvement compared with older methods of custom-made glassware, which was time-consuming and expensive, or the use of less chemical resistant and heat resistant corks or rubber bungs and glass tubes as joints, which took time to prepare as well.

<span class="mw-page-title-main">Cannula transfer</span>

Cannula transfer or cannulation is a set of air-free techniques used with a Schlenk line, in transferring liquid or solution samples between reaction vessels via cannulae, avoiding atmospheric contamination. While the syringes are not the same as cannulae, the techniques remain relevant.

The carpuject is a syringe device for the administration of injectable fluid medication. It was patented by the Sterling Drug Company, which became the Sterling Winthrop, after World War II. It is designed with a luer-lock device to accept a sterile hypodermic needle or to be linked directly to intravenous tubing line. The product can deliver an intravenous or intramuscular injection by means of a holder which attaches to the barrel and plunger to the barrel plug. Medication is prefilled into the syringe barrel. When the plug at the end of the barrel is advanced to the head of the barrel it discharges and releases the contents through the needle or into the lumen of the tubing.

Value Plastics is a designer, manufacturer, and global distributor of plastic tubing components used mainly in medical device, biotech, and industrial applications.

<span class="mw-page-title-main">Scuba cylinder valve</span> Valve controlling flow of breathing gas into and out of a scuba cylinder

A scuba cylinder valve or pillar valve is a high pressure manually operated screw-down shut off valve fitted to the neck of a scuba cylinder to control breathing gas flow to and from the pressure vessel and to provide a connection with the scuba regulator or filling whip. Cylinder valves are usually machined from brass and finished with a protective and decorative layer of chrome plating. A metal or plastic dip tube or valve snorkel screwed into the bottom of the valve extends into the cylinder to reduce the risk of liquid or particulate contaminants in the cylinder getting into the gas passages when the cylinder is inverted, and blocking or jamming the regulator.

References

  1. "ISO 80369-7:2016 - Small-bore connectors for liquids and gases in healthcare applications -- Part 7: Connectors for intravascular or hypodermic applications".
  2. "The Life and Death of the Luer | MDDI Medical Device and Diagnostic Industry News Products and Suppliers". Mddionline.com. 20 August 2012. Retrieved 2017-03-06.
  3. 1 2 Sella, Andrea (27 August 2012). "Lüer's syringe". Chemistry World.
  4. "ISO 594-1:1986 - Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements". Iso.org. Retrieved 2017-03-06.
  5. DIN and EN standard 1707:1996 "Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment - Lock fittings".
  6. DIN and EN 20594-1:1993 "Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment described".
  7. "The Life and Death of the Luer". MDDI Medical Device and Diagnostic Industry. 20 August 2012. Retrieved 2017-03-06.
  8. Ravin A. (1952) A Luer slip with a rotating lock. J. Lab Clin. Med.39(1), S. 168 PMID   14889106.
  9. Brown, Jim (August 20, 2012). "Sidebar: Air Show Disaster Elevates Luer Connector". Medical Device + Diagnostic Industry.