Macroscope (Wild-Leica)

Last updated
A Wild M400 macroscope Wild Heerbrugg M400.jpg
A Wild M400 macroscope

A macroscope or photomacroscope in its camera-equipped version (in German: makroskop / photomakroskop) is a type of optical microscope developed and named by Swiss microscope manufacturers Wild Heerbrugg and later, after that company's merger with Leica in 1987, by Leica Microsystems of Germany, optimised for high quality macro photography and/or viewing using a single objective lens and light path, rather than stereoscopic viewing of specimens, at magnifications up to around x40 (which can be increased further with optional supplementary lenses or higher power eyepieces). The Wild, subsequently Leica "macroscope" line was in production from approximately 1976–2003; it was succeeded by the Leica Z6 and Z16 offerings, which continued an equivalent (optically improved) functionality, but without the "macroscope" designation. The macroscope remains a useful, if somewhat specialised, instrument for examination of relevant specimens in various laboratories today. [1]

Contents

Description

The macroscope outwardly resembles a binocular microscope (stereo microscope) but has a single light path in place of the dual light paths of the latter, which is relayed as an identical image to both eyepieces, and optionally, a camera port. In the Wild era it was offered as the M400, M410, M420 and M450 instruments, [2] [3] [4] subsequently sold as the Leica M420 only. [5] Optimised for macro photography in particular (since the camera path passed through the centre of the imaging lens, thereby offering the best optical performance), the instrument was not intended for mass sale but for specialised technical use, such as in universities and research laboratories, for example for production of images for use in scientific publications, or for inspection and production control for microscopic circuits, etc., in the semiconductor industry. In addition to their generally good optical performance, macroscopes offer a large, fixed working distance independent of magnification setting between the bottom of the objective lens and the subject, which is advantageous for manipulation of the specimens and/or introduction of supplementary lighting, etc. A further benefit of the macroscope principle (in contrast to the stereo microscope) is there is no parallax error (apparent lateral shift of the specimen) when acquiring "z-stacks" or focus stacked images for subsequent merging. [6]

A Wild M420 macroscope Wild Heerbrugg M420.jpg
A Wild M420 macroscope

Model features and history

The Wild M400 and M450 were introduced in 1976, the M450 being essentially an M400 without the dedicated photo tube (thus intended for observation only). [7] The M400 was sold with a dedicated range of camera bodies controlled by a large electronics box separate from the microscope, with some of the camera elements (the exposure sensor and the shutter) incorporated into the microscope body, and was an expensive model to both make and purchase. Both it and the later M420 incorporated a manual aperture control (to control depth-of-field) and it was available with a "Macrozoom" objective with a magnification range of 6.3x to 32x, i.e., an approximate zoom ratio of 1:5. Supplementary lenses were available which modified the objective magnification by 0.5x, 1.5x or 2x. There also was a version of the M450 marketed as the EpiMakroScop, which had the "Epizoom" objective, essentially a Macrozoom with a permanently attached 2x front element, thus twice the magnification but only half of the potential field-of-view of its "standard" equivalent. [8] The (later) M420 was a cheaper option than the M400, lacking the electronic controls and in-microscope photography-associated features, but allowing the user to mount a camera of their choice on the top; the M410 was its sister model, designed for observation only (no photo tube). After the M420 production was taken over by Leica, initial models were offered with the same Macrozoom objective, and later ones with a new "Apozoom" objective possessing a zoom range between 5.8x and 35x (1:6), designed to provide higher resolution and better colour correction. [7] Final magnification in the image plane was calculated incorporating a 1.25x magnification in both the viewing and photo tubes, leading to (for example) a range of 7.875x to 40x for the Macrozoom-equipped system (quoted range using the 10x eyepieces), further variable via a choice of different eyepiece magnifications and/or the additional supplementary lenses that could be mounted on the objective.

Successors

The original "macroscope" line was formally dropped in around 2003, in favour of a redesigned product range, the Leica Z6 APO (6.3x zoom range) and Z16 APO (16x zoom range); these follow similar design principles but no longer incorporate "macroscope" in their model names, although the word persists as a descriptive term in some product literature. [9] [10] A fluorescence-equipped version of these instruments is also marketed as the Leica MacroFluo. [6]

Similar/earlier instruments

The term "macroscope" was not actually invented by Wild Heerbrugg but appears to have been a generic term used earlier by some other optical manufacturers including Bausch and Lomb (for a small monocular device), [11] and EdnaLite Research Corporation, whose "MacroScope" (also marketed as the "S/P (=Scientific Products) Macroscope system") included "four separate levels of magnification". [12]

Related Research Articles

<span class="mw-page-title-main">Binoculars</span> Pair of telescopes mounted side-by-side

Binoculars or field glasses are two refracting telescopes mounted side-by-side and aligned to point in the same direction, allowing the viewer to use both eyes when viewing distant objects. Most binoculars are sized to be held using both hands, although sizes vary widely from opera glasses to large pedestal-mounted military models.

<span class="mw-page-title-main">Optical microscope</span> Microscope that uses visible light

The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of microscope and were possibly invented in their present compound form in the 17th century. Basic optical microscopes can be very simple, although many complex designs aim to improve resolution and sample contrast.

<span class="mw-page-title-main">Leica Camera</span> German optics company

<span class="mw-page-title-main">Monocular</span> Optical device

A monocular is a compact refracting telescope used to magnify images of distant objects, typically using an optical prism to ensure an erect image, instead of using relay lenses like most telescopic sights. The volume and weight of a monocular are typically less than half of a pair of binoculars with similar optical properties, making it more portable and also less expensive. This is because binoculars are essentially a pair of monoculars packed together — one for each eye. As a result, monoculars only produce two-dimensional images, while binoculars can use two parallaxed images to produce binocular vision, which allows stereopsis and depth perception.

<span class="mw-page-title-main">Objective (optics)</span>

In optical engineering, an objective is an optical element that gathers light from an object being observed and focuses the light rays from it to produce a real image of the object. Objectives can be a single lens or mirror, or combinations of several optical elements. They are used in microscopes, binoculars, telescopes, cameras, slide projectors, CD players and many other optical instruments. Objectives are also called object lenses, object glasses, or objective glasses.

<span class="mw-page-title-main">Magnification</span> Process of enlarging the apparent size of something

Magnification is the process of enlarging the apparent size, not physical size, of something. This enlargement is quantified by a size ratio called optical magnification. When this number is less than one, it refers to a reduction in size, sometimes called de-magnification.

<span class="mw-page-title-main">Nikkor</span> Brand of lenses produced by Nikon

Nikkor is the brand of lenses produced by Nikon Corporation, including camera lenses for the Nikon F-mount.

<span class="mw-page-title-main">Eyepiece</span> Type of lens attached to a variety of optical devices such as telescopes and microscopes

An eyepiece, or ocular lens, is a type of lens that is attached to a variety of optical devices such as telescopes and microscopes. It is named because it is usually the lens that is closest to the eye when someone looks through an optical device to observe an object or sample. The objective lens or mirror collects light from an object or sample and brings it to focus creating an image of the object. The eyepiece is placed near the focal point of the objective to magnify this image to the eyes. The amount of magnification depends on the focal length of the eyepiece.

<span class="mw-page-title-main">Macro photography</span> Photography genre and techniques of extreme close-up pictures

Macro photography is extreme close-up photography, usually of very small subjects and living organisms like insects, in which the size of the subject in the photograph is greater than life size . By the original definition, a macro photograph is one in which the size of the subject on the negative or image sensor is life size or greater. In some senses, however, it refers to a finished photograph of a subject that is greater than life size.

<span class="mw-page-title-main">Panasonic Lumix DMC-FZ20</span>

Panasonic Lumix DMC-FZ20 is a 2004 superzoom bridge digital camera by Panasonic. It is the successor of the FZ10. The highest-resolution pictures it records are 2,560 by 1,920 pixels. It has a polycrystalline, thin-film transistor, liquid crystal display and EVF. It records to Secure Digital media. The camera also has a microphone. The camera's dimensions are 127.6 mm (5.02 

<span class="mw-page-title-main">Contax</span> Japanese camera brand

Contax began as a German camera model in the Zeiss Ikon line in 1932, and later became a brand name. The early cameras were among the finest in the world, typically featuring high quality Zeiss interchangeable lenses. The final products under the Contax name were a line of 35 mm, medium format, and digital cameras engineered and manufactured by Japanese multinational Kyocera, and featuring modern Zeiss optics. In 2005, Kyocera announced that it would no longer produce Contax cameras. The rights to the brand are currently part of Carl Zeiss AG, but no Contax cameras are currently in production, and the brand is considered dormant.

The Leica Digilux 1 is a digital camera developed in partnership with Panasonic, which was released in 2002, roughly the same time as the Canon PowerShot G2 and the Nikon 2000. It is the second of Leica's digital offerings. Where the original Digilux was developed in partnership with Fuji Camera, the Digilux 1 was developed jointly with Panasonic; Leica is responsible for optics, while Panasonic designs the camera electronics. According to Leica, this allows both companies to design cameras that creates a harmonious matching of lens to sensor to produce color and contrast to Leica standards.

A parfocal lens is a lens that stays in focus when magnification/focal length is changed. There is inevitably some amount of focus error, but too small to be considered significant.

<span class="mw-page-title-main">Panasonic Lumix DMC-FZ30</span>

Panasonic Lumix DMC-FZ30 is a bridge digital camera by Panasonic. It is the successor of the Panasonic Lumix DMC-FZ20. The highest-resolution pictures it records is 8 megapixels.

<span class="mw-page-title-main">Panasonic Lumix DMC-FZ50</span>

Panasonic Lumix DMC-FZ50 is a superzoom bridge digital camera by Panasonic.

<span class="mw-page-title-main">Close-up lens</span> Secondary lens used to enable macro photography

In photography, a close-up lens is a simple secondary lens used to enable macro photography without requiring a specialised primary lens. They work like reading glasses, allowing a primary lens to focus more closely. Bringing the focus closer allows the photographer more possibilities.

<span class="mw-page-title-main">Digital microscope</span>

A digital microscope is a variation of a traditional optical microscope that uses optics and a digital camera to output an image to a monitor, sometimes by means of software running on a computer. A digital microscope often has its own in-built LED light source, and differs from an optical microscope in that there is no provision to observe the sample directly through an eyepiece. Since the image is focused on the digital circuit, the entire system is designed for the monitor image. The optics for the human eye are omitted.

<span class="mw-page-title-main">Stereo microscope</span>

The stereo, stereoscopic or dissecting microscope is an optical microscope variant designed for low magnification observation of a sample, typically using light reflected from the surface of an object rather than transmitted through it. The instrument uses two separate optical paths with two objectives and eyepieces to provide slightly different viewing angles to the left and right eyes. This arrangement produces a three-dimensional visualization of the sample being examined. Stereomicroscopy overlaps macrophotography for recording and examining solid samples with complex surface topography, where a three-dimensional view is needed for analyzing the detail.

<span class="mw-page-title-main">Leica Microsystems</span>

Ernst Leitz GmbH was a German corporation based in Wetzlar, a German centre for optics as well as an important location for the precision engineering industry.

References

  1. A Google Scholar search for "wild" OR "leica" AND "macroscope", yielded 4,120 results as at August 2023; to repeat this search use this URL.
  2. Wild Heerbrugg AG: Wild Leitz M400 user manual
  3. Wild Heerbrugg AG: Wild M410 / M420 user manual
  4. Wild M450 brochure at www.savazzi.net
  5. Leica M420 Instruction Manual at www.manualslib.com.
  6. 1 2 Leica MacroFluo brochure at downloads.leica-microsystems.com.
  7. 1 2 Wild/Leica M420 (plus associated models), information page on www.savazzi.net.
  8. Le Naturaliste forum: loupe binoculaire Wild M400
  9. Leica Z6 APO and Z16 APO brochure - copy at www.savazzi.net.
  10. Leica Z6 APO Manual 6:1 Macroscope Leica Z6 APO
  11. Worthpoint.com: vintage 1960s Bausch & Lomb 10-30x zoom macroscope microscope on tripod w/case
  12. EdnaLite advertisement on p. 1189 of "Science" Magazine, vol. 138(3545), 7 December 1962; also marketed as the S/P (=Scientific Products) Macroscope system, as advertised in Journal of Bacteriology, year and volume not stated, refer p. 16 of this "advertisement" section