Mass spectrometric immunoassay

Last updated

Mass spectrometric immunoassay (MSIA) is a rapid method is used to detect and/ or quantify antigens and or antibody analytes. [1] This method uses an analyte affinity (either through antigens or antibodies) isolation to extract targeted molecules and internal standards from biological fluid in preparation for matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS). [2] [3] [4] This method allows for "top down" and "bottom up" analysis. This sensitive method allows for a new and improved process for detecting multiple antigens and antibodies in a single assay. [1] This assay is also capable of distinguishing mass shifted forms of the same molecule via a panantibody, as well as distinguish point mutations in proteins. [4] [5] Each specific form is detected uniquely based on their characteristic molecular mass. MSIA has dual specificity because of the antibody-antigen reaction coupled with the power of a mass spectrometer.

Contents

There are various other immunoassy techniques that have been used previously such as radioimmunoassay (RIA) and enzyme immunoassay (EIA and ELISA). These techniques are extremely sensitive however, there are many limitations to these methods. For example, quantification for ELISA and EIA require several hours because the binding has to reach equilibrium. [1] RIA's disadvantage is that you need radioactive particles which are universally known to be carcinogens.

The creation of MSIA fulfilled the need to determine the presence of one or more antigens in a specimen as well as the quantification of those said species.

History

This assay was patented in 2006 by Randall Nelson, Peter Williams and Jennifer Reeve Krone. [1] The idea first came about with the development of ELISA and RIA. [6] An earlier patent method suggested tagging antigens or antibodies with stable isotopes or long-lived radioactive elements. [7] But limitations to both methods called for a better detection methods of a protein or proteins. The invention combines antigen-antibody binding with a mass spectrometer which aids in identifying qualitatively and quantifying analytes respectively.

Mass spectrum generated using mass spectrometric immunoassay Myotoxin mass spectra.png
Mass spectrum generated using mass spectrometric immunoassay

An early MSIA experiment was done on a venom laced human blood sample for the Antigen myotoxin. The experiment was successful in that the mass spectrum resulting from the analysis showed a distinct response for myotoxin at the molecular weight corresponding to 4,822 Da (a). [1] The m/z ratio at 5,242 Da (b) is the molecular weight of the modified variant H-myotoxina, used as an internal reference species. The figure of the mass spectrum is shown below.

Methodology

schematic of the general procedure used for mass spectrometric immunoassays. Mass Spectrometric Immunoassay.png
schematic of the general procedure used for mass spectrometric immunoassays.

An illustration of the MSIA procedure is depicted in the figure to the right. Analytes in a biological liquid sample are collected from solution by using a MSIA tip (also known as MSIA microcolumns [8] ) that contains a derivatized affinity frit. Biological samples contain various proteins that span a wide dynamic range so purification is needed to minimize the complex matrix and maximize mass spectrometry sensitivity. [9] the MSIA tip serves as a place to purify these samples by immobilizing the analyte with high selectivity and specificity. Analytes are bound to the frit based on their affinities and all other nonspecific molecules are rinsed away. The specific targets are then eluted on to a mass spectrometer target plate with a MALDI matrix. However, proteins may be digested prior to ms analysis. A MALDI-TOF-MS later follows and targeted analytes are detected based on their m/z values. This method is qualitative, but the addition of mass shifted variants of the analyte for use as an internal standard makes this method useful for quantitative analysis. [5]

Pipetor tips, which have been termed MSIA tips or affinity pipette tips play a key role in the process of detecting analytes within biological samples. MSIA tips typically contain porous solid support which has derivatized antigens or antibodies covalently attached. Different analytes have different affinity for the tips so it is necessary to derivatize MSIA tips based on the analyte of interest. The main use of these tips are to flow samples through and the analytes affinity for the bound antigen/antibody allows for the capture of analyte. Non specifically bound compounds are rinsed out of the MSIA tips.

The process can be simplified into 6 simple steps which Thermo termed the "work flow".

  1. Gather Sample
  2. Load Affinity Ligand
  3. Purify Target Analyte
  4. Elute Target Analyte
  5. Pre-MS Sampling Process
  6. MS Analysis

Many "work flows" are commercially available for purchase.

Applications

MSIA is a method that can be used as an assay for a variety of different molecules such as proteins, hormones, drugs, toxins, and various pathogens found in biological fluids (Human and animal plasma, saliva, urine, tears etc.). [1] [10] MSIA has also been applied to clinical samples and have been proven to be a unique assay for clinically relevant proteins. [11] Successfully assaying toxins, drugs and other pathogens are important to the environment as well as the human body. MSIA can be used for a range of biomedical and environmental applications.

An important application of mass spectrometric immunoassy is that it can be used as a rapid, sensitive and accurate screening of apolipoproteins and mutations of them. Apolipoproteins represent a groups of proteins with many functions such as transport and clearance as well as enzyme activation. [4] Recent studies have claimed that mutations in apopliproteins result in, or assist in the progression of various associated diseases including amyloidosis, amyloid cardiomyopathy, Alzheimer's disease, hypertriglyceridemic, lowered cholesterol, hyperlipidemia and atherosclerosis to name a few. Nelson and colleagues did a study using MSIA to characterize and isolate apolipoproteins species.[ citation needed ]

Benefits

There are many benefits to using a mass spectrometric immunoassay. Most importantly, the assay is extremely fast and the data are reproducible, and automated. They are sensitive, precise and allows for absolute quantification. Analytes can be detected to low detection limits (as low as picomolar) and the assay covers a wide dynamic range [9] .

See also

Related Research Articles

Proteomics Large-scale study of proteins

Proteomics is the large-scale study of proteins. Proteins are vital parts of living organisms, with many functions. The proteome is the entire set of proteins that is produced or modified by an organism or system. Proteomics has enabled the identification of ever increasing numbers of protein. This varies with time and distinct requirements, or stresses, that a cell or organism undergoes. Proteomics is an interdisciplinary domain that has benefitted greatly from the genetic information of various genome projects, including the Human Genome Project. It covers the exploration of proteomes from the overall level of protein composition, structure, and activity. It is an important component of functional genomics.

ELISA Method to detect an antigen using an antibody and enzyme

The enzyme-linked immunosorbent assay (ELISA) is a commonly used analytical biochemistry assay, first described by Engvall and Perlmann in 1971. The assay uses a solid-phase type of enzyme immunoassay (EIA) to detect the presence of a ligand in a liquid sample using antibodies directed against the protein to be measured. ELISA has been used as a diagnostic tool in medicine, plant pathology, and biotechnology, as well as a quality control check in various industries.

An assay is an investigative (analytic) procedure in laboratory medicine, pharmacology, environmental biology and molecular biology for qualitatively assessing or quantitatively measuring the presence, amount, or functional activity of a target entity. The analyte can be a drug, biochemical substance, or cell in an organism or organic sample. The measured entity is often called the analyte, the measurand, or the target of the assay. An assay usually aims to measure an analyte's intensive property and express it in the relevant measurement unit.

Biochip

In molecular biology, biochips are essentially miniaturized laboratories that can perform hundreds or thousands of simultaneous biochemical reactions. Biochips enable researchers to quickly screen large numbers of biological analytes for a variety of purposes, from disease diagnosis to detection of bioterrorism agents. Digital microfluidic biochips have become one of the most promising technologies in many biomedical fields. In a digital microfluidic biochip, a group of (adjacent) cells in the microfluidic array can be configured to work as storage, functional operations, as well as for transporting fluid droplets dynamically.

A radioimmunoassay (RIA) is an immunoassay that uses radiolabeled molecules in a stepwise formation of immune complexes. A RIA is a very sensitive in vitro assay technique used to measure concentrations of substances, usually measuring antigen concentrations by use of antibodies.

Immunoassay Biochemical test for a protein or other molecule using an antibody

An immunoassay is a biochemical test that measures the presence or concentration of a macromolecule or a small molecule in a solution through the use of an antibody (usually) or an antigen (sometimes). The molecule detected by the immunoassay is often referred to as an "analyte" and is in many cases a protein, although it may be other kinds of molecules, of different sizes and types, as long as the proper antibodies that have the required properties for the assay are developed. Analytes in biological liquids such as serum or urine are frequently measured using immunoassays for medical and research purposes.

Protein methods are the techniques used to study proteins. There are experimental methods for studying proteins. Computational methods typically use computer programs to analyze proteins. However, many experimental methods require computational analysis of the raw data.

Heterophile antibodies are antibodies induced by external antigens.

Cross-reactivity, in a general sense, is the reactivity of an observed agent which initiates reactions outside the main reaction expected. This has implications for any kind of test or assay, including diagnostic tests in medicine, and can be a cause of false positives. In immunology, the definition of cross-reactivity refers specifically to the reaction of the immune system to antigens. There can be cross-reactivity between the immune system and the antigens of two different pathogens, or between one pathogen and proteins on non-pathogens, which in some cases can be the cause of allergies.

Antibody microarray

An antibody microarray is a specific form of protein microarray. In this technology, a collection of capture antibodies are spotted and fixed on a solid surface such as glass, plastic, membrane, or silicon chip, and the interaction between the antibody and its target antigen is detected. Antibody microarrays are often used for detecting protein expression from various biofluids including serum, plasma and cell or tissue lysates. Antibody arrays may be used for both basic research and medical and diagnostic applications.

Surface-enhanced laser desorption/ionization (SELDI) is a soft ionization method in mass spectrometry (MS) used for the analysis of protein mixtures. It is a variation of matrix-assisted laser desorption/ionization (MALDI). In MALDI, the sample is mixed with a matrix material and applied to a metal plate before irradiation by a laser, whereas in SELDI, proteins of interest in a sample become bound to a surface before MS analysis. The sample surface is a key component in the purification, desorption, and ionization of the sample. SELDI is typically used with time-of-flight (TOF) mass spectrometers and is used to detect proteins in tissue samples, blood, urine, or other clinical samples, however, SELDI technology can potentially be used in any application by simply modifying the sample surface.

Quantitative proteomics

Quantitative proteomics is an analytical chemistry technique for determining the amount of proteins in a sample. The methods for protein identification are identical to those used in general proteomics, but include quantification as an additional dimension. Rather than just providing lists of proteins identified in a certain sample, quantitative proteomics yields information about the physiological differences between two biological samples. For example, this approach can be used to compare samples from healthy and diseased patients. Quantitative proteomics is mainly performed by two-dimensional gel electrophoresis (2-DE) or mass spectrometry (MS). However, a recent developed method of quantitative dot blot (QDB) analysis is able to measure both the absolute and relative quantity of an individual proteins in the sample in high throughput format, thus open a new direction for proteomic research. In contrast to 2-DE, which requires MS for the downstream protein identification, MS technology can identify and quantify the changes.

Lateral flow test Immunochromatographic testing devices

Lateral flow tests, also known as lateral flow immunochromatographic assays, are simple devices intended to detect the presence of a target substance in a liquid sample without the need for specialized and costly equipment. These tests are widely used in medical diagnostics for home testing, point of care testing, or laboratory use. For instance, the home pregnancy test is a lateral flow test that detects a certain hormone. These tests are simple, economic and generally show results in around 5-30 minutes. Many lab-based applications increase the sensitivity of simple lateral flow tests by employing additional dedicated equipment.

Virus quantification involves counting the number of viruses in a specific volume to determine the virus concentration. It is utilized in both research and development (R&D) in commercial and academic laboratories as well as production situations where the quantity of virus at various steps is an important variable. For example, the production of viral vaccines, recombinant proteins using viral vectors and viral antigens all require virus quantification to continually adapt and monitor the process in order to optimize production yields and respond to ever changing demands and applications. Examples of specific instances where known viruses need to be quantified include clone screening, multiplicity of infection (MOI) optimization and adaptation of methods to cell culture. This page discusses various techniques currently used to quantify viruses in liquid samples. These methods are separated into two categories, traditional vs. modern methods. Traditional methods are industry-standard methods that have been used for decades but are generally slow and labor-intensive. Modern methods are relatively new commercially available products and kits that greatly reduce quantification time. This is not meant to be an exhaustive review of all potential methods, but rather a representative cross-section of traditional methods and new, commercially available methods. While other published methods may exist for virus quantification, non-commercial methods are not discussed here.

Surround optical-fiber immunoassay

Surround optical-fiber immunoassay (SOFIA) is an ultrasensitive, in vitro diagnostic platform incorporating a surround optical-fiber assembly that captures fluorescence emissions from an entire sample. The technology's defining characteristics are its extremely high limit of detection, sensitivity, and dynamic range. SOFIA's sensitivity is measured at the attogram level (10−18 g), making it about one billion times more sensitive than conventional diagnostic techniques. Based on its enhanced dynamic range, SOFIA is able to discriminate levels of analyte in a sample over 10 orders of magnitude, facilitating accurate titering.

A ligand binding assay (LBA) is an assay, or an analytic procedure, which relies on the binding of ligand molecules to receptors, antibodies or other macromolecules. A detection method is used to determine the presence and extent of the ligand-receptor complexes formed, and this is usually determined electrochemically or through a fluorescence detection method. This type of analytic test can be used to test for the presence of target molecules in a sample that are known to bind to the receptor.

Stable isotope standards and capture by anti-peptide antibodies (SISCAPA) is a mass spectrometry method for measuring the amount of a protein in a biological sample.

Fluorescence polarization immunoassay

Fluorescence polarization immunoassay (FPIA) is a class of in vitro biochemical test used for rapid detection of antibody or antigen in sample. FPIA is a competitive homogenous assay, that consists of a simple prepare and read method, without the requirement of separation or washing steps.

The enzyme-linked immune absorbent spot (ELISpot) is a type of assay that focuses on quantitatively measuring the frequency of cytokine secretion for a single cell. The ELISpot Assay is also a form of immunostaining since it is classified as a technique that uses antibodies to detect a protein analyte, with the word analyte referring to any biological or chemical substance being identified or measured.

Kinetic exclusion assay

A kinetic exclusion assay is a type of bioassay in which a solution containing receptor, ligand, and receptor-ligand complex is briefly exposed to additional ligand immobilized on a solid phase. A fraction of the free receptor is captured by the solid phase ligand and subsequently labeled with a fluorescent secondary molecule. The short contact time with the solid phase does not allow significant dissociation of the pre-formed complexes in the solution. Solution dissociation is thus “kinetically excluded” from contributing to the captured receptor and the resulting signal provides a measure of the free receptor in the solution. Measuring the free receptor as a function of total ligand in a series of equilibrated solutions enables calculation of the equilibrium dissociation constant (Kd). Measuring the free receptor with several points before equilibrium enables measurement of the association rate constant (kon). The off rate (koff) can also be directly measured, however it is usually calculated from the measured Kd and measured kon,

References

  1. 1 2 3 4 5 6 US 6974704B2
  2. Nelson, Randall W.; Krone, Jennifer R.; Bieber, Allan L.; Williams, Peter. (1995). "Mass Spectrometric Immunoassay". Analytical Chemistry. 67 (7): 1153–1158. doi:10.1021/ac00103a003. OSTI   1087876. PMID   15134097.
  3. Niederkofler, Eric E.; Tubbs, Kemmons A.; Gruber, Karl; Nedelkov, Dobrin; Kiernan, Urban A.; Williams, Peter; Nelson, Randall W. (2001-07-01). "Determination of β-2 Microglobulin Levels in Plasma Using a High-Throughput Mass Spectrometric Immunoassay System". Analytical Chemistry. 73 (14): 3294–3299. doi:10.1021/ac010143j. ISSN   0003-2700. PMID   11476228.
  4. 1 2 3 Niederkofler, Eric E.; Tubbs, Kemmons A.; Kiernan, Urban A.; Nedelkov, Dobrin; Nelson, Randall W. (2003-03-01). "Novel mass spectrometric immunoassays for the rapid structural characterization of plasma apolipoproteins". Journal of Lipid Research. 44 (3): 630–639. doi: 10.1194/jlr.d200034-jlr200 . ISSN   0022-2275. PMID   12562854.
  5. 1 2 Tubbs, Kemmons A.; Nedelkov, Dobrin; Nelson, Randall W. (2001). "Detection and Quantification of β-2-Microglobulin Using Mass Spectrometric Immunoassay". Analytical Biochemistry. 289 (1): 26–35. doi:10.1006/abio.2000.4921. PMID   11161291.
  6. Nelson, Randall W.; Borges, Chad R. (2011-06-01). "Mass Spectrometric Immunoassay Revisited". Journal of the American Society for Mass Spectrometry. 22 (6): 960–968. Bibcode:2011JASMS..22..960N. doi:10.1007/s13361-011-0094-z. ISSN   1044-0305. PMC   3761394 . PMID   21953037.
  7. USpatent 4022876A
  8. "Thermo Fisher Scientific". youtube.com.
  9. 1 2 "Thermo Scientific Mass Spectrometric Immunoassay" (PDF). ThermoFisher. 2014. Retrieved April 5, 2018.
  10. Nelson, Randall W.; Nedelkov, Dobrin; Tubbs, Kemmons A.; Kiernan, Urban A. (2004-08-01). "Quantitative Mass Spectrometric Immunoassay of Insulin Like Growth Factor 1". Journal of Proteome Research. 3 (4): 851–855. doi:10.1021/pr0499388. ISSN   1535-3893. PMID   15359740.
  11. Krastins, Bryan; Prakash, Amol; Sarracino, David A.; Nedelkov, Dobrin; Niederkofler, Eric E.; Kiernan, Urban A.; Nelson, Randall; Vogelsang, Maryann S.; Vadali, Gouri (2013). "Rapid development of sensitive, high-throughput, quantitative and highly selective mass spectrometric targeted immunoassays for clinically important proteins in human plasma and serum". Clinical Biochemistry. 46 (6): 399–410. doi:10.1016/j.clinbiochem.2012.12.019. PMC   3779129 . PMID   23313081.