Rain roof

Last updated

A rain roof is a second, newer roof that has been constructed over an existing roof that has failed, or which has inadequate slope to shed rain. Since such additional spaces may not be visible or accessible, the concealed void presents a particular hazard in firefighting operations, as a fire may develop or persist in such a space undetected.

Contents

Description

Rain roofs are commonly found in North America over an older flat or minimally sloped roof that has developed leaks, or in a building that has been added to in a manner that requires revised drainage patterns. Construction usually involves framing or trusses that create a space above the original roof, which remains in place, which are then covered with new roofing materials. Side and end walls may be extended upwards to create sufficient space for the framing and to enclose the new space. [1]

While rain roofs are commonly found in large, older commercial buildings, they may also be built over single and double-wide mobile homes to improve drainage. [1]

Fire safety

Firefighting operations can be complicated by the presence of the undetected concealed space, and by the presence of a second water-shedding roof underneath. A concealed space, potentially unknown to firefighters, and difficult or impossible to access, may allow a fire to grow or persist in spite of firefighting operations inside and outside the building. [1]

A rain roof was a significant hazard that contributed to the deaths of six New York City Fire Department firefighters in the 1978 Waldbaum's supermarket fire. [2]

See also

Related Research Articles

<span class="mw-page-title-main">Roof</span> Top covering of a building

A roof is the top covering of a building, including all materials and constructions necessary to support it on the walls of the building or on uprights, providing protection against rain, snow, sunlight, extremes of temperature, and wind. A roof is part of the building envelope.

<span class="mw-page-title-main">Firefighter</span> Rescuer trained to extinguish fires and save people

A firefighter is a first responder trained in firefighting, primarily to control and extinguish fires that threaten life and property, as well as to rescue persons from confinement or dangerous situations. Male firefighters are sometimes referred to as firemen.

<span class="mw-page-title-main">Shed</span> Type of structure: a small hut used for storage or as a workspace

A shed is typically a simple, single-story roofed structure that is used for hobbies, or as a workshop in a back garden or on an allotment. Sheds vary considerably in their size and complexity of construction, from simple open-sided ones designed to cover bicycles or garden items to large wood-framed structures with shingled roofs, windows, and electrical outlets. Sheds used on farms or in the industry can be large structures. The main types of shed construction are metal sheathing over a metal frame, plastic sheathing and frame, all-wood construction, and vinyl-sided sheds built over a wooden frame. Small sheds may include a wooden or plastic floor, while more permanent ones may be built on a concrete pad or foundation. Sheds may be lockable to deter theft or entry by children, domestic animals, wildlife, etc.

<span class="mw-page-title-main">Dormer</span> Structural element of a building

A dormer is a roofed structure, often containing a window, that projects vertically beyond the plane of a pitched roof. A dormer window is a form of roof window.

<span class="mw-page-title-main">Firefighting</span> Actions to prevent damage from fire

Firefighting is a profession aimed at controlling and extinguishing fire. A person who engages in firefighting is known as a firefighter or fireman. Firefighters typically undergo a high degree of technical training. This involves structural firefighting and wildland firefighting. Specialized training includes aircraft firefighting, shipboard firefighting, aerial firefighting, maritime firefighting, and proximity firefighting.

In firefighting, the policy of two-in, two-out refers to United States Occupational Safety and Health Administration (OSHA) policy 29 CFR 1910.134(g)(4)(i). The respiratory protection standard requires that workers engaged in fighting interior structural fires work in a buddy system; at least two workers must enter the building together, so that they can monitor each other's whereabouts as well as the work environment. There must also be at least two standby personnel outside the fire area prepared to rescue the inside firefighters should the need arise. One of these outside firefighters must actively monitor the status of the inside fighters but the second outside firefighter may perform a variety of other duties, such as pump operations, incident commander or outside hose line operation. There are no provisions in the standard to waive the requirements for either the "two-inside firefighters" or the "two-outside firefighters", although the circumstances under which this provision applies are more limited than generally understood.

Firefighting jargon includes a diverse lexicon of both common and idiosyncratic terms. One problem that exists in trying to create a list such as this is that much of the terminology used by a particular department is specifically defined in their particular standing operating procedures, such that two departments may have completely different terms for the same thing. For example, depending on whom one asks, a safety team may be referred to as a standby, a RIT or RIG or RIC, or a FAST. Furthermore, a department may change a definition within its SOP, such that one year it may be RIT, and the next RIG or RIC.

This is a glossary of firefighting equipment.

<span class="mw-page-title-main">Framing (construction)</span> Construction technique

Framing, in construction, is the fitting together of pieces to give a structure support and shape. Framing materials are usually wood, engineered wood, or structural steel. The alternative to framed construction is generally called mass wall construction, where horizontal layers of stacked materials such as log building, masonry, rammed earth, adobe, etc. are used without framing.

Waldbaum's was a supermarket chain with stores in the New York City boroughs of Brooklyn, Queens, Staten Island, and the Bronx; and in Nassau, Suffolk counties and Upstate New York. The chain also for a time operated stores in New Jersey, Connecticut, and Massachusetts. Founded in 1904, Waldbaum's was one of seven "banner store chains" owned and operated by The Great Atlantic & Pacific Tea Company (A&P), which acquired the chain from its founding family in 1986.

<span class="mw-page-title-main">Aircraft rescue and firefighting</span>

Aircraft rescue and firefighting (ARFF) is a type of firefighting that involves the emergency response, mitigation, evacuation, and rescue of passengers and crew of aircraft involved in aviation accidents and incidents.

<span class="mw-page-title-main">Roof pitch</span> Measure of roof steepness

Roof pitch is the steepness of a roof expressed as a ratio of inch(es) rise per horizontal foot, or as the angle in degrees its surface deviates from the horizontal. A flat roof has a pitch of zero in either instance; all other roofs are pitched.

A placard is a notice installed in a public place, like a small card, sign, or plaque. It can be attached to or hung from a vehicle or building to indicate information about the vehicle operator or contents of a vehicle or building. It can also refer to paperboard signs or notice carried by picketers or demonstrators.

An ember attack is when, during a bushfire, embers such as burning twigs, bark fragments, moss or leaves become temporarily airborne and are carried by winds in a cluster.

Ventilation is a part of structural firefighting tactics, and involves the expulsion of heat and smoke from a burning building, permitting the firefighters to more easily and safely find trapped individuals and attack the fire. If a large fire is not properly ventilated, it is much harder to fight, and can build up enough poorly burned smoke to create a smoke explosion or enough heat to create a flashover. Poorly placed or timed ventilation can increase the fire's air supply, causing it to grow and spread rapidly. Flashover from inadequate ventilation can cause the temperature inside the building to peak at over 1,000 °C (1,830 °F).

<span class="mw-page-title-main">New Bedford Fire Museum</span> Firefighting museum in MA, United States

The New Bedford Fire Museum is a local history museum at 51 Bedford Street in New Bedford, Massachusetts, United States. It is located in the 1867 Fire Station No. 4, the city's oldest surviving fire station. The building was listed on the National Register of Historic Places in 1975. The museum is open between July 4 and Labor Day. It houses a collection of firefighting equipment and memorabilia related to the history of firefighting in the city.

<span class="mw-page-title-main">Buford Tower</span> Historic structure in Austin, Texas

Buford Tower is a tower standing along the north shore of Lady Bird Lake in downtown Austin, Texas. The structure was originally built in 1930 as a drill tower for the Austin Fire Department, but it now serves as a bell tower and landmark. Named after fire department Captain James L. Buford, the structure has been listed on the National Register of Historic Places since 2016.

<span class="mw-page-title-main">Firefighting apparatus</span> Vehicle for use during firefighting operations

A firefighting apparatus or firefighting appliance describes any vehicle that has been customized for use during firefighting operations. These vehicles are highly customized depending on their needs and the duty they will be performing. These duties can include firefighting and emergency medical services.

The Waldbaum's Supermarket Fire was a major American fire on 2 August 1978 in Sheepshead Bay, Brooklyn, New York City that killed six FDNY firefighters. The Waldbaum's store at 2892 Ocean Avenue was undergoing extensive renovations, but was open for customers when the fire broke out.

A cockloft is a horizontal void between a building's uppermost ceiling and its roof, with no habitable space.They are typically of combustible construction, with limited or no access. They may create a large space over multiple occupancies or adjoining buildings. They are commonly present in North America in older commercial buildings and rowhouses, with the roof above sloping from front to back, creating a shallow attic-like space.

References

  1. 1 2 3 Smith, Michael L. (February 1, 2007). "Rain Roofs Do More Than Shed Rain!". Firehouse. Retrieved 16 January 2024.
  2. Quintiere, J.G. "Fire Investigation; an Analysis of the Waldbaum Fire Brooklyn NY August 3 1978". National Institute of Standards and Technology. Retrieved 16 January 2024.