An interstitial space is an intermediate space located between regular-use floors, commonly located in hospitals and laboratory-type buildings to allow space for the mechanical systems of the building. By providing this space, laboratory and hospital rooms may be easily rearranged throughout their lifecycles and therefore reduce lifecycle cost.

Contents

Description

An interstitial space is useful when the mechanical system of the building is highly sophisticated and changing the space on the primary floors is a distinct possibility. The heights of these spaces are generally six to eight feet and allow easy access for repair or alteration. [1] If changes or maintenance need to be performed in the interstitial space, the primary space does not need to be shut down, which is important in buildings like hospitals where the equipment in the space must operate constantly. Unlike traditionally built buildings, where the mechanical space is located in the basement or on the top floor, the interstitial space needs few vertical penetrations and therefore leaves more open space on the primary floor. The entire floor plan of these buildings can be more open because there are fewer fixed vertical penetrations through the floor and walls.

Another way to use an interstitial space is to incorporate a design that divides the functions of the building into groups and localizes them. The Zeidler Partnership Architects’ (ZPA) design of the William Osler Health Centre (WOHC) in Brampton, Ontario, is one example of this design. (Note: this was designed but ZPA was not awarded the project.) The groups in this design are based on similar structural and mechanical systems. Flexible design allows for easy expansion or redesign in the future. Horizontal expansion is especially easy because of the interstitial space between the surgical suite and the emergency floors, where the mechanical system functions are the most crucial in this building. Double floor height is used to maintain the horizontal flow of connections throughout the rest of the building without causing any interference with other building systems.

History

The idea of using an interstitial space was started in the 1960s by professors at Texas A&M University’s College of Architecture. Their concept was to standardize spaces and allow for rapid changes in medical facilities. While the spaces for building systems like plumbing, mechanical, and electrical systems were not as large as today’s, it was an important beginning of an idea to separate the systems by floor. The first building to actually use an interstitial space design was Louis Kahn’s Salk Institute of Biological Studies in La Jolla, California. The design allowed the building to keep up with ever-changing technology. [2] From there, designs progressed to concepts created by Zeidler Partnership Architects (ZPA); a firm who has completed over 40 healthcare and lab facilities for buildings using an interstitial space design. [3] Today, many firms have drawn inspiration from ZPA and use their concept to develop their own design. Some designs cover the whole floor area and some, like the WOHC, are partial interstitial spaces.

Pros and cons of using an interstitial space

Pros

Interstitial spaces are exceedingly useful when a building needs to be re-modeled. In a medical or lab facility, where technology can change quickly, future equipment sizes and requirements can be unpredictable. With an interstitial space, room layouts in the primary floor may be altered much more easily than traditionally designed buildings since there are fewer service stacks penetrating the floors. The walls can be arranged and rearranged freely. If a drastic renovation must occur, only one floor at a time has to be shut down for renovation, instead of the whole building. The cost of the building is reduced significantly since major equipment does not have to be changed during a renovation. Lifecycle cost includes anything that pertains to the building from when it is in its schematic design phase until it is demolished. A chart of the cost distribution is shown in figure 2. If the equipment itself must be retrofitted, it can be done faster, since the spaces have ample area to work and are separated by floor. The lifetime of the building may also be increased, since the adaptable spaces may be retrofitted instead of needing to be torn down for a redesigned building.

Figure 2. Lifecycle building cost pie chart. Lifecycle building cost pie chart.jpg
Figure 2. Lifecycle building cost pie chart.

Separating the building systems from the primary space can also be helpful during construction. If sequenced correctly, it can decrease the installation time of major equipment significantly. Each trade may work on one floor and move to the next after another is finished. Also, wall, ceiling, and floor finishes may be worked on while the building systems are installed as opposed to a traditionally designed building where they would have to wait for more equipment to be installed.

Another advantage of using an interstitial space is that easy access to the equipment in them may encourage preventative maintenance. If a more efficient system can be installed easily, it can again reduce lifecycle cost.

Cons

The largest and most well known negative of interstitial spaces is a high first cost. [4] Adding more floors increases the amount of material used for floor decks, walls, etc. The construction expense becomes much larger when anything is added because it affects many other systems in the building. One main thing that increases is the amount of façade material necessary to cover the skin of the building. Depending on that material, the cost and time of construction could be largely inflated.

Equipment costs can become a large deterrent of owners also. Several smaller pieces of equipment must be purchased for each floor instead of one large piece for the whole building. The large piece of equipment is much cheaper than all of the small pieces combined in almost every case.

Related Research Articles

A colocation center or "carrier hotel", is a type of data centre where equipment, space, and bandwidth are available for rental to retail customers. Colocation facilities provide space, power, cooling, and physical security for the server, storage, and networking equipment of other firms and also connect them to a variety of telecommunications and network service providers with a minimum of cost and complexity.

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Passive solar building design</span> Architectural engineering that uses the Suns heat without electric or mechanical systems

In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.

<span class="mw-page-title-main">Fire sprinkler system</span> Fire protection method

A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available at a cost-effective price.

<span class="mw-page-title-main">Basement</span> Below-ground floor of a building

A basement or cellar is one or more floors of a building that are completely or partly below the ground floor. Especially in residential buildings, it often is used as a utility space for a building, where such items as the furnace, water heater, breaker panel or fuse box, car park, and air-conditioning system are located; so also are amenities such as the electrical system and cable television distribution point. In cities with high property prices, such as London, basements are often fitted out to a high standard and used as living space.

<span class="mw-page-title-main">Structural insulated panel</span>

A structural insulated panel, or structural insulating panel, (SIP), is a form of sandwich panel used in the construction industry.

<span class="mw-page-title-main">Adaptive reuse</span> Reuse of an existing building for a new purpose

Adaptive reuse refers to the process of reusing an existing building for a purpose other than which it was originally built or designed for. It is also known as recycling and conversion. Adaptive reuse is an effective strategy for optimizing the operational and commercial performance of built assets. Adaptive reuse of buildings can be an attractive alternative to new construction in terms of sustainability and a circular economy. It has prevented thousands of buildings' demolition and has allowed them to become critical components of urban regeneration. Not every old building can qualify for adaptive reuse. Architects, developers, builders and entrepreneurs who wish to become involved in rejuvenating and reconstructing a building must first make sure that the finished product will serve the need of the market, that it will be completely useful for its new purpose, and that it will be competitively priced.

<span class="mw-page-title-main">Dropped ceiling</span> Secondary ceiling hung below a main ceiling

A dropped ceiling is a secondary ceiling, hung below the main (structural) ceiling. It may also be referred to as a drop ceiling, T-bar ceiling, false ceiling, suspended ceiling, grid ceiling, drop in ceiling, drop out ceiling, or ceiling tiles and is a staple of modern construction and architecture in both residential and commercial applications.

<span class="mw-page-title-main">Modular design</span> Design approach

Modular design, or modularity in design, is a design principle that subdivides a system into smaller parts called modules, which can be independently created, modified, replaced, or exchanged with other modules or between different systems.

<span class="mw-page-title-main">Raised floor</span> Elevated floor above a solid substrate to create a void for mechanical and electrical services

A raised floor provides an elevated structural floor above a solid substrate to create a hidden void for the passage of mechanical and electrical services. Raised floors are widely used in modern office buildings, and in specialized areas such as command centers, Information technology data centers and computer rooms, where there is a requirement to route mechanical services and cables, wiring, and electrical supply. Such flooring can be installed at varying heights from 2 inches (51 mm) to heights above 4 feet (1.2 m) to suit services that may be accommodated beneath. Additional structural support and lighting are often provided when a floor is raised enough for a person to crawl or even walk beneath.

A building envelope or building enclosure is the physical separator between the conditioned and unconditioned environment of a building, including the resistance to air, water, heat, light, and noise transfer.

<span class="mw-page-title-main">Noise control</span> Strategies to reduce noise pollution or its impact

Noise control or noise mitigation is a set of strategies to reduce noise pollution or to reduce the impact of that noise, whether outdoors or indoors.

<span class="mw-page-title-main">Retrofitting</span> Addition of new technology or features to older systems

Retrofitting is the addition of new technology or features to older systems. Retrofits can happen for a number of reasons, for example with big capital expenditures like naval vessels, military equipment or manufacturing plants, businesses or governments may retrofit in order to reduce the need to replace a system entirely. Other retrofits may be due to changing codes or requirements, such as seismic retrofit which are designed strengthening older buildings in order to make them earthquake resistant.

<span class="mw-page-title-main">Building insulation</span> Material to reduce heat transfer in structures

Building insulation is material used in a building to reduce the flow of thermal energy. While the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an insulation material will be chosen for its ability to perform several of these functions at once.

<span class="mw-page-title-main">Cable management</span>

Cable management refers to management of electrical or optical cable in a cabinet or an installation. The term is used for products, workmanship or planning. Cables can easily become tangled, making them difficult to work with, sometimes resulting in devices accidentally becoming unplugged as one attempts to move a cable. Such cases are known as "cable spaghetti", and any kind of problem diagnosis and future updates to such enclosures could be very difficult.

HVAC is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized terms and acronyms, many of which are summarized in this glossary.

<span class="mw-page-title-main">Central vacuum cleaner</span> Type of vacuum cleaner appliance

A central vacuum cleaner is a type of vacuum cleaner appliance installed into a building as a semi-permanent fixture. Central vacuum systems are designed to remove dirt and debris from homes and buildings by sending dirt particles through piping installed inside the walls to a collection container in a remote utility space. The power unit is a permanent fixture, usually installed in a basement, garage, or storage room, along with the collection container. Inlets are installed in walls throughout the building that attach to power hoses and other central vacuum accessories to remove dust, particles, and small debris from interior rooms. Most power hoses have a power switch located on the handle.

Sustainable refurbishment describes working on existing buildings to improve their environmental performance using sustainable methods and materials. A refurbishment or retrofit is defined as: "any work to a building over and above maintenance to change its capacity, function or performance' in other words, any intervention to adjust, reuse, or upgrade a building to suit new conditions or requirements". Refurbishment can be done to a part of a building, an entire building, or a campus. Sustainable refurbishment takes this a step further to modify the existing building to perform better in terms of its environmental impact and its occupants' environment.

<span class="mw-page-title-main">Mechanical, electrical, and plumbing</span> Subfields of building design and construction

Mechanical, electrical and plumbing (MEP) refers to the installation of services which provide a comfortable space for the building occupants. In residential and commercial buildings, these elements are often designed by specialized MEP engineering firms. The part of Mechanical in the overall MEP system is almost 70% of the total work. MEP's design is important for planning, decision-making, accurate documentation, performance- and cost-estimation, construction, and operating/maintaining the resulting facilities.

<span class="mw-page-title-main">Electrical conduit</span> Tube used to protect and route electrical wiring in a building or structure

An electrical conduit is a tube used to protect and route electrical wiring in a building or structure. Electrical conduit may be made of metal, plastic, fiber, or fired clay. Most conduit is rigid, but flexible conduit is used for some purposes.

References

  1. Hospital and Healthcare Facility Design: 2nd Edition. Richard L. Miller and Earl S. Swensson. W W Norton & Co Inc., 2002, pp. 5152
  2. David J. Fine and Stephen Vanderber. Healthcare In An Era Of Radical Transformation. Yale University Press, 2000, pp. 116-117
  3. Zeidler, Eberhard H. (2004). "Planning for Change: Hospital Design Theories in Practice". American Institute of Architects. Archived from the original on 5 July 2007. Retrieved 2023-01-11.{{cite web}}: CS1 maint: unfit URL (link)
  4. David R. Riley and Sandra Vondrak. Interstitial Space Design In Modern Laboratories. Journal of Architectural Engineering, Vol. 11, No. 2, June 2005, pp. 60-70