AS-Interface

Last updated

Actuator Sensor Interface (AS-Interface or ASi) is an industrial networking solution (physical layer, data access method and protocol) used in PLC, DCS and PC-based automation systems. It is designed for connecting simple field I/O devices (e.g. binary ON/OFF devices such as actuators, sensors, rotary encoders, analog inputs and outputs, push buttons, and valve position sensors) in discrete manufacturing and process applications using a single two-conductor cable.

Contents

AS-Interface is an 'open' technology supported by a multitude of automation equipment vendors. The AS-Interface has been an international standard according to IEC 62026-2 since 1999.

AS-Interface is a networking alternative to the hard wiring of field devices. It can be used as a partner network for higher level fieldbus networks such as Profibus, DeviceNet, Interbus and Industrial Ethernet, for whom it offers a low-cost remote I/O solution. It is used in automation applications, including conveyor control, packaging machines, process control valves, bottling plants, electrical distribution systems, airport baggage carousels, elevators, bottling lines and food production lines. AS-Interface provides a basis for Functional Safety in machinery safety/emergency stop applications. Safety devices communicating over AS-Interface follow all the normal AS-Interface data rules. The AS-Interface specification is managed by AS-International, a member funded non-profit organization located in Gelnhausen/Germany. Several international subsidiaries exist around the world.

History

AS-Interface was developed during the late 1980s and early 1990s by a development partnership of 11 companies mostly known for their offering of industrial non-contact sensing devices like inductive sensors, photoelectric sensors, capacitive sensors and ultrasonic sensors. Once development was completed the consortium was resolved and a member organization, AS-International , was founded. The first operational system was shown at the 1994 Hanover fair.

In 2018, a new technology step was presented at SPS IPC Drives in Nuremberg. This technology is named ASi-5. ASi-5 was developed by well-known manufacturers of automation technology.

Use

The AS-Interface (from the Actuator Sensor Interface) has been developed as an alternative to conventional parallel cabling of sensors and actuators and offers the following advantages:

The main application areas of the system are factory automation, process technology and home automation.

Technology

The AS-Interface is a single-master system, this means a master device exchanges the input and output data with all configured devices. The transmission medium is an unshielded two-wire yellow flat cable. The cable is used for signal transmission and at the same time for power supply (30 V). The communication electronics and participants with low power requirements, like light beams, can be powered directly. Consumers with a higher energy requirement, such as valve terminals, can use a separate, usually black flat cable for power supply (30 V).

The sensors or actuators are often connected via the so-called piercing technology. The insulation of the polarity profiled flat cable is pierced by means of two penetrating mandrels during assembly, this makes an easy and simple connection with reduced assembly efforts. Sensors and actuators that do not have an AS-Interface connection can be connected to the system via modules. For modules with penetration technology, the AS-Interface flat cable must be used.

Here is a flat cable drawing ASi CABLE2.JPG
Here is a flat cable drawing

The topology of the AS-Interface networks is arbitrary. You can build lines, star, ring or tree structures.

ASi-3 communication and transmission technology

A telegram (message frame) consists of 4-bit user data. The master communicates with the participants with a serial transmission protocol. Each subscriber is assigned an address by an addressing device or via the master. A maximum of 31 (standard devices) or 62 (advanced devices) nodes can be connected. Each node can have up to four inputs and/or four outputs for actuators or sensors. This provides up to 124 (4 x 31 = 124) input and 124 outputs on a standard device network (nodes addressed 1-31) or 248 (4 x 62 = 248) inputs and 248 outputs on an advanced network (nodes addressed 1A - 31A and 1B - 31B ). The serial communication is modulated onto the power supply. Manchester coding is used for the communication. For 31 participants, the cycle is 5 ms. To address 62 participants, two cycles are necessary. The topology of the AS-Interface is arbitrary, but without a repeater or extender, the cable length must not exceed 100 m. Due to a special terminating resistor (a combination of resistive and capacitive load), however, it is possible to increase the maximum cable length up to 300 m. Diagnostic devices or masters with built-in diagnostics simplify network troubleshooting. Failed slaves can be easily replaced, the master automatically redirects them. Safety at Work is the concept of functional safety used in ASi-3 technology. This means that safety-related components such as emergency stop actuations, door interlocks or light grids can be used in the AS-Interface network. This is a different transmission protocol overlaid onto the regular ASi protocol on the same cable and requires a separate safety master such as Siemens ASiMon devices on which your safety devices are configured. AS-Interface can provide safety support up to SIL (Safety Integrity Level) 3 according to IEC 61508 as well as Performance Level e (PL e) according to EN ISO 13849-1.

ASi-5 communication and transmission technology

16 bits are available for cyclic transmission using ASi-5. A cyclic transmission of up to 32 bytes per participant is possible. An acyclic parameter channel with up to 256 bytes is available for each device as well. ASi-5 is to provide a set of up to 1536 binary inputs and 1536 binary outputs per Ethernet address. 1.2 ms cycle time can be achieved by the system for up to 24 participants. This fast cycle time allows new fields of applications that were previously reserved for expensive network systems. 96 participants can be addressed in an ASi-5 network. These 96 devices then have a cycle time of 5 ms. Communication diagnostics describes the information about message transmission between the connected nodes and the master. The system continuously monitors the transmission quality of the messages from each device connected. This single channel diagnosis is available in the system. Disturbed transmission channels are redirected automatically. Device diagnostics provides information about the connected device. The available diagnostics data are determined by the device manufacturer. Diagnostic data can be transmitted via the acyclic services with a data width of up to 256 bytes. The ASi-5 system is open for the use of parameter interfaces such as e.g. IO-Link. IO-Link devices can be efficiently collected over long distances and could be integrated cyclically up to 32 bytes. 16 safe bits are available for safety-related switching devices, such as emergency stop, light curtains, safety switches and similar are available. It is possible to achieve Safety Integrity Level (SIL)3 Performance Level e according to IEC 13849 for functional safety. ASi-5 uses a novel communication method. The new ASi-5 technology allows the use of ASi-3 components together with components of the new ASi-5 technology on a common cable. If ASi-3 devices are to be used together with ASi-5 components, then in addition to the corresponding devices the use of a new ASi-3 / ASi-5 master is required. Old systems can be easily upgraded by new devices with additional functions. New systems can be installed on a cable using proven ASi-3 components and new ASi-5 devices.

Standardization

The AS-Interface is described in the international standard IEC 62026-2: 2015. Other local standards are: Europe: EN 62026-2: 2015 Japan: JIS C 82026-2 (2013) China: GB / T 18858.2 (2002) Korea: KS C IEC 62026-2 (2007)

AS-Interface products are certified by the AS-International Association e.V. Tests and certifications ensure that devices from different manufacturers work together. The concepts of functional safety at AS-Interface have been positively assessed by the TÜV (Technical Inspection Association) or the Institute for Occupational Safety of the German Social Accident Insurance and confirmed the fulfillment of the relevant safety standards.

Related Research Articles

<span class="mw-page-title-main">Programmable logic controller</span> Programmable digital computer used to control machinery

A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity that requires high reliability, ease of programming, and process fault diagnosis. Dick Morley is considered as the father of PLC as he had invented the first PLC, the Modicon 084, for General Motors in 1968.

Supervisory control and data acquisition (SCADA) is a control system architecture comprising computers, networked data communications and graphical user interfaces for high-level supervision of machines and processes. It also covers sensors and other devices, such as programmable logic controllers, which interface with process plant or machinery.

<span class="mw-page-title-main">I²C</span> Serial communication bus

I2C (Inter-Integrated Circuit; pronounced as “eye-squared-C”), alternatively known as I2C or IIC, is a synchronous, multi-master/multi-slave (controller/target), single-ended, serial communication bus invented in 1982 by Philips Semiconductors. It is widely used for attaching lower-speed peripheral ICs to processors and microcontrollers in short-distance, intra-board communication.

<span class="mw-page-title-main">KNX</span> Standard in building automation

KNX is an open standard for commercial and residential building automation. KNX devices can manage lighting, blinds and shutters, HVAC, security systems, energy management, audio video, white goods, displays, remote control, etc. KNX evolved from three earlier standards; the European Home Systems Protocol (EHS), BatiBUS, and the European Installation Bus.

A Controller Area Network is a vehicle bus standard designed to allow microcontrollers and devices to communicate with each other's applications without a host computer. It is a message-based protocol, designed originally for multiplex electrical wiring within automobiles to save on copper, but it can also be used in many other contexts. For each device, the data in a frame is transmitted serially but in such a way that if more than one device transmits at the same time, the highest priority device can continue while the others back off. Frames are received by all devices, including by the transmitting device.

<span class="mw-page-title-main">Profibus</span> Communications protocol

Profibus is a standard for fieldbus communication in automation technology and was first promoted in 1989 by BMBF and then used by Siemens. It should not be confused with the Profinet standard for Industrial Ethernet. Profibus is openly published as type 3 of IEC 61158/61784-1.

<span class="mw-page-title-main">1-Wire</span> Device communications bus system

1-Wire is a wired half duplex serial bus designed by Dallas Semiconductor that provides low-speed (16.3 kbit/s) data communication and supply voltage over a single conductor.

Modbus or MODBUS is a client/server data communications protocol in the application layer of the OSI model. It was originally published by Modicon in 1979 for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol for communication between industrial electronic devices in a wide range of buses and network.

A vehicle bus is a specialized internal communications network that interconnects components inside a vehicle. In electronics, a bus is simply a device that connects multiple electrical or electronic devices together. Special requirements for vehicle control such as assurance of message delivery, of non-conflicting messages, of minimum time of delivery, of low cost, and of EMF noise resilience, as well as redundant routing and other characteristics mandate the use of less common networking protocols. Protocols include Controller Area Network (CAN), Local Interconnect Network (LIN) and others. Conventional computer networking technologies are rarely used, except in aircraft, where implementations of the ARINC 664 such as the Avionics Full-Duplex Switched Ethernet are used. Aircraft that use AFDX include the B787, the A400M and the A380. Trains commonly use Ethernet Consist Network (ECN). All cars sold in the United States since 1996 are required to have an On-Board Diagnostics connector, for access to the car's electronic controllers.

A fieldbus is a member of a family of industrial digital communication networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158.

A process automation or automation system (PAS) is used to automatically control a process such as chemical, oil refineries, paper and pulp factories. The PAS often uses a network to interconnect sensors, controllers, operator terminals and actuators. A PAS is often based on open standards in contrast to a DCS, which is traditionally proprietary. However in recent times the PAS is considered to be more associated with SCADA systems.

<span class="mw-page-title-main">Profinet</span> Computer network protocol

Profinet is an industry technical standard for data communication over Industrial Ethernet, designed for collecting data from, and controlling equipment in industrial systems, with a particular strength in delivering data under tight time constraints. The standard is maintained and supported by Profibus and Profinet International, an umbrella organization headquartered in Karlsruhe, Germany.

CANopen is a communication protocol and device profile specification for embedded systems used in automation. In terms of the OSI model, CANopen implements the layers above and including the network layer. The CANopen standard consists of an addressing scheme, several small communication protocols and an application layer defined by a device profile. The communication protocols have support for network management, device monitoring and communication between nodes, including a simple transport layer for message segmentation/desegmentation. The lower level protocol implementing the data link and physical layers is usually Controller Area Network (CAN), although devices using some other means of communication can also implement the CANopen device profile.

EtherCAT is an Ethernet-based fieldbus system developed by Beckhoff Automation. The protocol is standardized in IEC 61158 and is suitable for both hard and soft real-time computing requirements in automation technology.

Digital Addressable Lighting Interface (DALI) is a trademark for network-based products that control lighting. The underlying technology was established by a consortium of lighting equipment manufacturers as a successor for 1-10 V/0–10 V lighting control systems, and as an open standard alternative to several proprietary protocols. The DALI, DALI-2 and D4i trademarks are owned by the lighting industry alliance, DiiA.

An industrial control system (ICS) is an electronic control system and associated instrumentation used for industrial process control. Control systems can range in size from a few modular panel-mounted controllers to large interconnected and interactive distributed control systems (DCSs) with many thousands of field connections. Control systems receive data from remote sensors measuring process variables (PVs), compare the collected data with desired setpoints (SPs), and derive command functions that are used to control a process through the final control elements (FCEs), such as control valves.

DeviceNet is a network protocol used in the automation industry to interconnect control devices for data exchange. It utilizes the Common Industrial Protocol over a Controller Area Network media layer and defines an application layer to cover a range of device profiles. Typical applications include information exchange, safety devices, and large I/O control networks.

Sercos III is the third generation of the Sercos interface, a standardized open digital interface for the communication between industrial controls, motion devices, input/output devices (I/O), and Ethernet nodes, such as PCs. Sercos III applies the hard real-time features of the Sercos interface to Ethernet. It is based upon and conforms to the Ethernet standard. Work began on Sercos III in 2003, with vendors releasing first products supporting it in 2005.

AS-International is the nonprofit trade association for AS-Interface users worldwide.

IO-Link is a short distance, bi-directional, digital, point-to-point, wired, industrial communications networking standard used for connecting digital sensors and actuators to either a type of industrial fieldbus or a type of industrial Ethernet. Its objective is to provide a technological platform that enables the development and use of sensors and actuators that can produce and consume enriched sets of data that in turn can be used for economically optimizing industrial automated processes and operations. The technology standard is managed by the industry association Profibus and Profinet International.

References