Coal burner

Last updated
Coal burner working as a component of an asphalt plant in Thailand Coal burner in Thailand.jpg
Coal burner working as a component of an asphalt plant in Thailand

A coal burner (or pulverized coal burner) is a mechanical device that burns pulverized coal (also known as powdered coal or coal dust since it is as fine as face powder in cosmetic makeup) into a flame in a controlled manner. Coal burners are mainly composed of the pulverized coal machine, the host of combustion machine (including combustion chamber, automatic back and forth motion system, automatic rotation system, the combustion air supply system) control system, ignition system, the crater[ clarification needed ] and others.

Contents

Mechanism

In the worksite, a coal burner usually works with the coal pulverizer and coal hopper. The coal in the hopper is conveyed to the coal pulverizer by screw conveyor. The coal pulverizer will crush the coal into pulverized coal. In the coal burner, the pulverized coal mixes with air (high-speed air flow is generated by the draft fan on the coal burner), and is ignited by the oil burning igniter.

Ignition

There are mainly two ways to ignite the coal burner. These are manual and automatic, differing in that in automatic systems, a high-energy ignition device generates sparks, replacing people's hands. [1]

Use

Pulverized coal burners have a wide range of uses in industrial production and daily life, such as providing heat for boilers, hot mix asphalt plant, cement kiln, metal furnace, annealing, quenching furnace, precision casting shell burning furnace, melting furnace, forging furnace and other heating furnace or kiln.

Requirements for coal

Note: These indexes are the lowest requirements for the coal.

See also

Related Research Articles

<span class="mw-page-title-main">Boiler</span> Closed vessel in which fluid is heated

A boiler is a closed vessel in which fluid is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, central heating, boiler-based power generation, cooking, and sanitation.

<span class="mw-page-title-main">Briquette</span> Compressed block of biomass used for fueling a fire

A briquette is a compressed block of coal dust or other combustible biomass material used for fuel and kindling to start a fire. The term derives from the French word brique, meaning brick.

<span class="mw-page-title-main">Fuel gas</span> Fuels which under ordinary conditions, are gaseous

Fuel gas is one of a number of fuels that under ordinary conditions are gaseous. Most fuel gases are composed of hydrocarbons, hydrogen, carbon monoxide, or mixtures thereof. Such gases are sources of energy that can be readily transmitted and distributed through pipes.

A cyclone furnace is a type of coal combustor commonly used in large industrial boilers.

<span class="mw-page-title-main">Pilot light</span> Small gas flame used to light larger gas burner

A pilot light is a small gas flame, usually natural gas or liquefied petroleum gas, which serves as an ignition source for a more powerful gas burner. Originally a pilot light was kept permanently alight, but this wastes gas. Now it is more common to light a burner electrically, but gas pilot lights are still used when a high energy ignition source is necessary, as in when lighting a large burner.

<span class="mw-page-title-main">Thermal power station</span> Power plant that generates electricity from heat energy

A thermal power station is a type of power station in which heat energy is converted to electrical energy. In a steam-generating cycle heat is used to boil water in a large pressure vessel to produce high-pressure steam, which drives a steam turbine connected to an electrical generator. The low-pressure exhaust from the turbine enters a steam condenser where it is cooled to produce hot condensate which is recycled to the heating process to generate more high pressure steam. This is known as a Rankine cycle.

<span class="mw-page-title-main">Air preheater</span> Device designed to heat air before another process

An air preheater is any device designed to heat air before another process (for example, combustion in a boiler With the primary objective of increasing the thermal efficiency of the process. They may be used alone or to replace a recuperative heat system or to replace a steam coil.

<span class="mw-page-title-main">Pellet fuel</span> Solid fuel made from compressed organic material

Pellet fuels are a type of solid fuel made from compressed organic material. Pellets can be made from any one of five general categories of biomass: industrial waste and co-products, food waste, agricultural residues, energy crops, and untreated lumber. Wood pellets are the most common type of pellet fuel and are generally made from compacted sawdust and related industrial wastes from the milling of lumber, manufacture of wood products and furniture, and construction. Other industrial waste sources include empty fruit bunches, palm kernel shells, coconut shells, and tree tops and branches discarded during logging operations. So-called "black pellets" are made of biomass, refined to resemble hard coal and were developed to be used in existing coal-fired power plants. Pellets are categorized by their heating value, moisture and ash content, and dimensions. They can be used as fuels for power generation, commercial or residential heating, and cooking.

<span class="mw-page-title-main">Pellet stove</span> Stove that uses pellet fuel

A pellet stove is a stove that burns compressed wood or biomass pellets to create a source of heat for residential and sometimes industrial spaces. By steadily feeding fuel from a storage container (hopper) into a burn pot area, it produces a constant flame that requires little to no physical adjustments. Today's central heating systems operated with wood pellets as a renewable energy source can reach an efficiency factor of more than 90%.

<span class="mw-page-title-main">Forced-air</span> HVAC system

A forced-air central heating system is one which uses air as its heat transfer medium. These systems rely on ductwork, vents, and plenums as means of air distribution, separate from the actual heating and air conditioning systems. The return plenum carries the air from several large return grills (vents) to a central air handler for re-heating. The supply plenum directs air from the central unit to the rooms which the system is designed to heat. Regardless of type, all air handlers consist of an air filter, blower, heat exchanger/element/coil, and various controls. Like any other kind of central heating system, thermostats are used to control forced air heating systems.

A pulverized coal-fired boiler is an industrial or utility boiler that generates thermal energy by burning pulverized coal that is blown into the firebox.

A pulverizer or grinder is a mechanical device for the grinding of many different types of materials. For example, a pulverizer mill is used to pulverize coal for combustion in the steam-generating furnaces of coal power plants.

<span class="mw-page-title-main">Oil burner</span>

An oil burner is a heating device which burns #1, #2 and #6 heating oils, diesel fuel or other similar fuels. In the United States ultra low #2 diesel is the common fuel used. It is dyed red to show that it is road-tax exempt. In most markets of the United States heating oil is the same specification of fuel as on-road un-dyed diesel.

<span class="mw-page-title-main">Coal-fired power station</span> Type of thermal power station

A coal-fired power station or coal power plant is a thermal power station which burns coal to generate electricity. Worldwide there are over 2,400 coal-fired power stations, totaling over 2,000 gigawatts capacity. They generate about a third of the world's electricity, but cause many illnesses and the most early deaths, mainly from air pollution.

Turndown ratio refers to the width of the operational range of a device, and is defined as the ratio of the maximum capacity to minimum capacity. For example, a device with a maximum output of 10 units and a minimum output of 2 units has a turndown ratio of 5. The term is commonly used with measurement devices and combustion plant like boilers and gasifiers.

<span class="mw-page-title-main">Wood-burning stove</span> Type of stove

A wood-burning stove is a heating or cooking appliance capable of burning wood fuel, often called solid fuel, and wood-derived biomass fuel, such as sawdust bricks. Generally the appliance consists of a solid metal closed firebox, often lined by fire brick, and one or more air controls. The first wood-burning stove was patented in Strasbourg in 1557. This was two centuries before the Industrial Revolution, so iron was still prohibitively expensive. The first wood-burning stoves were high-end consumer items and only gradually became used widely.

Staged combustion is a method used to reduce the emission of nitrogen oxides (NOx) during combustion. There are two methods for staged combustion: air staged supply and fuel staged supply. Applications of staged combustion include boilers and rocket engines.

Coal-water slurry fuel is a combustible mixture of fine coal particles suspended in water. It can be used to power boilers, gas turbines, diesel engines and heating and power stations.

Pellet heating is a heating system in which wood pellets are combusted. Other pelletized fuels such as straw pellets are used occasionally. Today's central heating system which run on wood pellets as a renewable energy source are comparable in operation and maintenance of oil and gas heating systems.

<span class="mw-page-title-main">Pellet boiler</span> Heating system

A pellet boiler is a heating system that burns wood pellets. Pellet boilers are used in central heating systems for heat requirements from 3.9 kW (kilowatt) to 1 MW (megawatt) or more. Pellet central heating systems are used in single family homes, and in larger residential, commercial, or institutional applications. Pellet boiler systems run most efficiently at full load and can usually be regulated down to 30% of full load. Since the warm up phase of pellet boilers usually takes longer than for oil or gas firing systems, short burning phases have negative effects on the fuel efficiency. In order to improve energy efficiency and reduce harmful emissions, pellet boilers are usually combined with buffer systems, such as insulated water tanks.

References

  1. "Ignition System of Pulverized Coal Burner". Pulverized Coal Burners. Bertrand. Archived from the original on 2 April 2015. Retrieved 2 April 2015.