Cured-in-place pipe

Last updated
Sewage repairmen inserting uncured liner into a soon-to-be repaired pipe Trenchless sewer relining repairmen.jpg
Sewage repairmen inserting uncured liner into a soon-to-be repaired pipe

A cured-in-place pipe (CIPP) is a trenchless rehabilitation method used to repair existing pipelines. It is a jointless, seamless pipe lining within an existing pipe. As one of the most widely used rehabilitation methods, CIPP has applications in sewer, water, gas, chemical and district heating pipelines ranging in diameter from 0.1 to 2.8 meters (2–110 inches).

Contents

The process of CIPP involves inserting and running a felt lining into a preexisting pipe that is the subject of repair. Resin within the liner is then exposed to a curing element to harden it and make it attach to the inner walls of the pipe. Once fully cured, the lining now acts as a new pipeline.

Process

Installation

A resin impregnated felt tube made of polyester, fiberglass cloth, spread tow carbon fiber or other resin-impregnable substance, is inserted or pulled through a damaged pipe, usually from an upstream access point such as a manhole or excavation. (It is possible to insert the liner from a downstream access point, but this is more risky). CIPP is considered a trenchless technology, meaning little to no digging is typically required, for a potentially more cost-effective and less disruptive method than traditional "dig and replace" pipe repair methods. The liner is inserted using water or air pressure, applied via pressure vessels, scaffolds or a "chip unit".

Curing

Cured-in-place pipes require that their resin be cured after installation to achieve full strength, by hot water or steam or, if a fiberglass tube is used, by UV light. As the resin cures, a tight-fitting, jointless and corrosion-resistant replacement pipe is formed. Service laterals, where present, can be reconnected from within the newly-formed larger-diameter pipe, by cutting replacement openings using robotically controlled cutting devices, then sealed using specially-designed CIPP materials referred to as 'top-hats'. The resins used are typically polyester for mainline lining and epoxy for lateral lines. Since all resins shrink (epoxy resins shrink far less than poly and vinyl ester versions) and because it is impossible to bond to a sewer line with fats, oils, and grease present, an annular space is always created around the new CIPP liner, between it and the host pipe. Some spaces are large enough to require additional work to prevent water from moving along them and re-entering the waste stream, for example: insertion of hydrophilic material which swells to fill the void; lining of the entire connection and host pipe with continuous repair (YT repair) gaskets; and point repairs placed at the ends of the host pipe.

History

Conception

In 1971, Eric Wood implemented the first cured-in-place pipe technology in London, England. He called the CIPP process insitu form, derived from the Latin meaning "form in place". Wood applied for U.S. patent no. 4009063 on January 29, 1975. The patent was granted February 22, 1977, and was commercialized by Insituform Technologies until it entered the public domain on February 22, 1994.

Implementation

The process began to be used in residential and commercial applications in Japan and Europe in the 1970s and for residential application in the United States in the 1980s. [1]

Advantages

CIPP does not typically require excavation to rehabilitate a leaking or structurally unsound pipeline. (Depending upon design considerations an excavation may be made, but the liner is often installed through a manhole or other existing access point.) CIPP has a smooth, jointless interior and no joints.

Disadvantages and limitations

Except for very common sizes, liners are not usually stocked and must be made specifically for each project. [2] CIPP requires bypassing the existing pipeline while the liner is being installed, which may be inconvenient as, depending on diameter and system used (steam, water or UV), curing may take from one to 30 hours and must be carefully monitored, inspected, and tested. Obstructions in the existing pipeline, such as protruding laterals, must be removed prior to installation. CIPP is not always cheaper than similar methods such as Shotcrete, thermoformed pipe, close-fit pipe, spiral wound pipe and sliplining. The CIPP process may release chemical agents into the surrounding environment. The most common liner material, a non-woven felted fabric, does not go around bends well without wrinkling nor maintain roundness going around corners. Once a line is repaired with the CIPP method, it can no longer be cleaned using cables or snakes; instead, high-pressure water blasting (hydrojetting) must be used.

Quality assurance and quality control

Testing of CIPP installations is required to confirm that the materials used comply with the site and engineering requirements. Since ground and ambient installation conditions as well as crew skills can affect the success or failure of a cure cycle, testing is performed by 3rd party laboratories in normal cases and should be requested by the owner.

Samples should be representative of the installation environment since the liner is installed in the ground. Wet sandbags should be used around the restraint where the test sample will be extracted from. As with any specimen preparation for a materials test, it is important to not affect the material properties during the specimen preparation process. Research has shown that test specimen selection can have a significant effect on the CIPP flexural testing results. A technical presentation [3] at the CERIU INFRA 2012 Infrastructures Municipales Conference in Montreal outlined the results of a research project which examined the effects of test specimen preparation on measured flexural properties. Test specimens for ASTM D790 flexural testing must meet the dimensional tolerances of ASTM D790.

The North American CIPP industry has standardized around the standard ASTM F1216 which uses test specimens oriented parallel with the pipe axis, while Europe uses the standard EN ISO 11296–4 with test specimens oriented in the hoop direction. Research has shown that flexural testing results from the same liner material are usually lower when determined using EN ISO 11296-4 as compared to ASTM F1216.

Environmental, public health, and infrastructure incidents

Testing conducted by the Virginia Department of Transportation [4] and university researchers [5] from 2011 to 2013 showed that some CIPP installations can cause aquatic toxicity. [6] A list of environmental, public health, and infrastructure incidents caused by CIPP installations as of 2013 was published by the Journal of Environmental Engineering. [7] In 2014, university researchers [5] published a more detailed study in Environmental Science & Technology [8] that examined CIPP condensate chemical and aquatic toxicity as well as chemical leaching from stormwater culvert CIPP installations in Alabama. [9] In this new report additional water and air environmental contamination incidents were reported not previously described elsewhere.

In 2017, CALTRANS backed university researchers [10] examined water impacts caused by CIPPs used for stormwater culvert repairs. [11]

In April 2018, a study funded by six state transportation agencies (1) compiled and reviewed CIPP-related surface water contamination incidents from publicly reported data; (2) analyzed CIPP water quality impacts; (3) evaluated current construction practices for CIPP installations as reported by US state transportation agencies; and (4) reviewed current standards, textbooks, and guideline documents. [12] [13] In 2019, another study funded by these agencies identified actions to reduce chemical release from ultraviolet light (UV) CIPP manufacturing sites. [14]

With proper engineering design specifications, contractor installation procedures, and construction oversight many of these problems can likely be prevented.

Worker and public safety concerns

On July 26, 2017, Purdue University researchers published a peer-reviewed study in the American Chemical Society's journal Environmental Science & Technology Letters about material emissions collected and analyzed from steam cured CIPP installations in Indiana and California. [15] To further make the study accessible to the public and CIPP worker community, the study authors established a website and made their publication open-access, freely available for download. Purdue University professors also commented on their study and called for changes to the process to better protect workers, the public, and environment from harm. [16]

On August 25, 2017, the National Association of Sewer Service Companies, Incorporated (NASSCO), which is a (501c6) nonprofit dedicated to "improving the success rate of everyone involved in the pipeline rehabilitation industry through education, technical resources, and industry advocacy", posted a document on its website [17] bringing up several important concerns and unanswered questions regarding the study, and its messaging. NASSCO then sent a letter to the researchers who then responded. [18]

On September 22, 2017, NASSCO announced it would fund and coordinate an assessment of previous data and studies, and an additional study [19] and analysis of possible risks related to the CIPP installation and curing process. Later in September, the NASSCO posted a request for proposals to “review of recent publication(s) that propose the presence of organic chemicals and other available literature relating to emissions associated with the CIPP installation process, and a scope of services for additional sampling and analysis of emissions during the field installation of CIPP using the steam cure process.” The request specifically identified the project would review studies conducted by the Virginia Department of Transportation, California Department of Transportation, and Purdue University.

At the federal and state levels in September 2017, on September 26, the US Centers for Disease Control and Prevention (CDC) National Institute for Occupational Safety and Health (NIOSH) published a Science Blog contribution regarding Inhalation and Dermal Exposure Risks Associated with Sanitary Sewer, Storm Sewer, and Drinking Water Pipe Repairs. [20] In September 2017, the California Department of Public Health issued a notice to municipalities and health officials about CIPP installations. One of several statements in this document was that "municipalities, engineers, and contractors should not tell residents the exposures are safe." [21]

On October 5, 2017, the National Environmental Health Association sponsored a webinar about the hazards involved for workers and residents associated with cured-in-place pipe repair. The video can be found here. [22] Several questions [23] about the webinar, and the study have been raised, and feedback noted by industry members.

On October 25, 2017, a 22-year old CIPP worker died at a sanitary sewer worksite in Streamwood, Illinois. [24] The U.S. Occupational Safety and Health Administration (OSHA) completed their investigation April 2018 and issued the company a penalty. Chemical exposure was a contributing factor in the worker fatality.

In 2018, NASSCO funded a study on chemical emissions from six CIPP installations. [25] In 2020, the study was completed. [26] A few locations and worker tasks were identified of potential chemical exposure concern and worksite recommendations were provided.

In 2019 and 2021, the U.S. National Institute for Occupational Safety and Health published a safety evaluations ofUV, steam and hot water CIPP worksites. A UV CIPP company was the first to engage NIOSH. Study results indicated several worker chemical exposure conditions that exceeded recommended limits, and this US federal agency recommended several actions to reduce worker exposures. [27] Two years later, the NIOSH published results of a steam and hot water CIPP worksite study. [28] Results indicated several worker chemical exposure conditions that exceeded recommended limits. The US federal agency recommended several actions to reduce worker exposures.

In 2020, the Florida Department of Health issued their own factsheet about CIPP to municipalities and health departments. [29] The document explained the CIPP process, health concerns, chemicals used and created, how persons living nearby can protect themselves from exposure, and biomonitoring and blood testing considerations after exposure.

In 2022, researchers made several additional discoveries. In the Journal of Hazardous Materials, a study funded by the National Institute of Environmental Health Sciences and National Science Foundation revealed CIPP pressure makes blowback from sinks and toilets in nearby buildings possible and provided recommendations for emergency responders and health officials. [30] Later that year, a study in the Journal of Cleaner Production revealed that by modifying the initiator loading, an ingredient in thermal based CIPP resins, pollution potential of the process could be reduced by 33-42%. Though, also found was that non-styrene CIPP resin contained styrene due to handling at the resin processing facility. [31] In October, researchers discovered that steam based CIPP creates and emits nanoplastics into the air during plastic manufacture. [32] Results of these investigations help better understand the occupational safety, bystander safety, and environmental pollution risks associated with current practices, and also improve technology and practice to reduce undesirable consequences.

See also

Related Research Articles

Fiberglass or fibreglass is a common type of fiber-reinforced plastic using glass fiber. The fibers may be randomly arranged, flattened into a sheet called a chopped strand mat, or woven into glass cloth. The plastic matrix may be a thermoset polymer matrix—most often based on thermosetting polymers such as epoxy, polyester resin, or vinyl ester resin—or a thermoplastic.

<span class="mw-page-title-main">Stormwater</span> Water that originates during precipitation events and snow/ice melt

Stormwater, also written storm water, is water that originates from precipitation (storm), including heavy rain and meltwater from hail and snow. Stormwater can soak into the soil (infiltrate) and become groundwater, be stored on depressed land surface in ponds and puddles, evaporate back into the atmosphere, or contribute to surface runoff. Most runoff is conveyed directly as surface water to nearby streams, rivers or other large water bodies without treatment.

<span class="mw-page-title-main">Water pollution</span> Contamination of water bodies

Water pollution is the contamination of water bodies, with a negative impact on their uses. It is usually a result of human activities. Water bodies include lakes, rivers, oceans, aquifers, reservoirs and groundwater. Water pollution results when contaminants mix with these water bodies. Contaminants can come from one of four main sources. These are sewage discharges, industrial activities, agricultural activities, and urban runoff including stormwater. Water pollution may affect either surface water or groundwater. This form of pollution can lead to many problems. One is the degradation of aquatic ecosystems. Another is spreading water-borne diseases when people use polluted water for drinking or irrigation. Water pollution also reduces the ecosystem services such as drinking water provided by the water resource.

<span class="mw-page-title-main">Sanitary sewer</span> Underground pipe for transporting sewage

A sanitary sewer is an underground pipe or tunnel system for transporting sewage from houses and commercial buildings to a sewage treatment plant or disposal.

Trenchless technology is a type of subsurface construction work that requires few trenches or no continuous trenches. It is a rapidly growing sector of the construction and civil engineering industry. It can be defined as "a family of methods, materials, and equipment capable of being used for the installation of new or replacement or rehabilitation of existing underground infrastructure with minimal disruption to surface traffic, business, and other activities."

<span class="mw-page-title-main">Bisphenol A</span> Chemical compound used in plastics manufacturing

Bisphenol A (BPA) is a chemical compound primarily used in the manufacturing of various plastics. It is a colourless solid which is soluble in most common organic solvents, but has very poor solubility in water. BPA is produced on an industrial scale by the condensation reaction of phenol and acetone. Global production in 2022 was estimated to be in the region of 10 million tonnes.

<span class="mw-page-title-main">High-density polyethylene</span> Class of polyethylenes

High-density polyethylene (HDPE) or polyethylene high-density (PEHD) is a thermoplastic polymer produced from the monomer ethylene. It is sometimes called "alkathene" or "polythene" when used for HDPE pipes. With a high strength-to-density ratio, HDPE is used in the production of plastic bottles, corrosion-resistant piping, geomembranes and plastic lumber. HDPE is commonly recycled, and has the number "2" as its resin identification code.

<span class="mw-page-title-main">Crumb rubber</span> Recycled rubber produced from scrap tires

Crumb rubber is recycled rubber produced from automotive and truck scrap tires. During the recycling process, steel and tire cord (fluff) are removed, leaving tire rubber with a granular consistency. Continued processing with a granulator or cracker mill, possibly with the aid of cryogenics or by mechanical means, reduces the size of the particles further. The particles are sized and classified based on various criteria including color. The granulate is sized by passing through a screen, the size based on a dimension or mesh. Crumb rubber is often used in artificial turf as cushioning.

Pipe bursting is a trenchless method of replacing buried pipelines without the need for a traditional construction trench. "Launching and receiving pits" replace the trench needed by conventional pipe-laying.

<span class="mw-page-title-main">Engineered stone</span> Composite material

Engineered stone is a composite material made of crushed stone bound together by an adhesive to create a solid surface. The adhesive is most commonly polymer resin, with some newer versions using cement mix. This category includes engineered quartz (SiO2), polymer concrete and engineered marble stone. The application of these products depends on the original stone used. For engineered marbles the most common application is indoor flooring and walls, while the quartz based product is used primarily for kitchen countertops as an alternative to laminate or granite. Related materials include geopolymers and cast stone. Unlike terrazzo, the material is factory made in either blocks or slabs, cut and polished by fabricators, and assembled at the worksite.

<span class="mw-page-title-main">Pipefitter</span> Tradesman who works with mechanical pipes

A pipefitter or steamfitter is a tradesman who installs, assembles, fabricates, maintains, and repairs mechanical piping systems. Pipefitters usually begin as helpers or apprentices. Journeyman pipefitters deal with industrial/commercial/marine piping and heating/cooling systems. Typical industrial process pipe is under high pressure, which requires metals such as carbon steel, stainless steel, and many different alloy metals fused together through precise cutting, threading, grooving, bending, and welding. A plumber concentrates on lower pressure piping systems for sewage and potable tap water in the industrial, commercial, institutional, or residential atmosphere. Utility piping typically consists of copper, PVC, CPVC, polyethylene, and galvanized pipe, which is typically glued, soldered, or threaded. Other types of piping systems include steam, ventilation, hydraulics, chemicals, fuel, and oil.

<span class="mw-page-title-main">Vitrified clay pipe</span>

Vitrified clay pipe (VCP) is pipe made from a blend of clay and shale that has been subjected to high temperature to achieve vitrification, which results in a hard, inert ceramic.

Insituform Technologies, Inc. is a worldwide provider of trenchless technologies for gravity and pressure pipelines. Insituform is a subsidiary of Aegion Corporation.

Sliplining is a technique for repairing leaks or restoring structural stability to an existing pipeline. It involves installing a smaller, "carrier pipe" into a larger "host pipe", grouting the annular space between the two pipes, and sealing the ends. Sliplining has been used since the 1940s.

Michels Corporation is a family-owned and operated energy and infrastructure construction company headquartered in Brownsville, WI. Established in 1959, Michels Corporation ranks #27th out of 400 top contractors in North America, performing work throughout the world.

<span class="mw-page-title-main">Philadelphia Water Department</span>

The Philadelphia Water Department is the public water utility for the City of Philadelphia. PWD provides integrated potable water, wastewater, and stormwater services for Philadelphia and some communities in Bucks, Delaware and Montgomery counties. PWD is a municipal agency of the City of Philadelphia, and is seated in rented space at the Jefferson Tower in the Market East area of Center City, Philadelphia.

<span class="mw-page-title-main">East Side Big Pipe</span>

The East Side Big Pipe is a large sewer line and tunnel in Portland in the U.S. state of Oregon. It is part of a combined sewer system of pipes, sumps, drains, pumps, and other infrastructure that transports sewage and stormwater run-off to the city's Columbia Boulevard Wastewater Treatment Plant. The East Side Big Pipe project, begun in 2006 and finished in 2011, was the largest of a 20-year series of projects designed to nearly eliminate combined sewer overflows (CSO)s into the Willamette River and the Columbia Slough. The combined projects were completed on time, and they reduced CSOs into the river by 94 percent and into the slough by more than 99 percent.

Sprayed in place pipe (SIPP) technologies is a trench-less rehabilitation method used to repair existing pipelines, that involves a robotic lining system that develops and manufactures proprietary lining polymeric. SIPP is a jointless, seamless, pipe with in a pipe with the capability to rehabilitate pipes ranging in diameter of .1 to 2.8 meters. SIPP can be applied in water, sewer, gas, and chemical pipelines.

<span class="mw-page-title-main">Occupational hazards of solar panel installation</span>

The introduction and rapid expansion of solar technology has brought with it a number of occupational hazards for workers responsible for panel installation. Guidelines for safe solar panel installation exist, however the injuries related to panel installation are poorly quantified.

<span class="mw-page-title-main">Lead service line</span> Pipe used to connect water main to users

A lead service line is a pipe made of lead which is used in potable water distribution to connect a water main to a user's premises.

References

  1. "Pipers Pick Epoxy To Plug Pinholes". The Washington Post . October 5, 2002. Archived from the original on October 22, 2012. Retrieved December 29, 2008.
  2. Mohammed Najafi, PhD, PE and Sanjov Gokhale, PhD, PE, Trenchless Technology (New York: McGraw Hill, 2004), p. 295–311. Available from Water Environment Federation at "Trenchless Technology Pipeline and Utility Design, Construction, and Renewal". Archived from the original on April 18, 2008. Retrieved May 4, 2009..
  3. Araujo, T. (November 19, 2012). "Essais de Flexion du Chemisage (Flexural Testing of CIPP)" (PDF). Ceriu.qc.ca/.
  4. "Virginia Department of Transportation - Home". www.VirginiaDOT.org. Retrieved September 3, 2017.
  5. 1 2 "Maintenance". www.SouthCE.org. Retrieved September 3, 2017.
  6. Whelton, A.J., Salehi, M., Tabor, M., Donaldson, B., and Estaba, J. (2013). ”Impact of Infrastructure Coating Materials on Storm-Water Quality: Review and Experimental Study.” J. Environ. Eng., 139(5), 746–756.
  7. Whelton Andrew J.; Salehi Maryam; Tabor Matthew; Donaldson Bridget; Estaba Jesus (May 1, 2013). "Impact of Infrastructure Coating Materials on Storm-Water Quality: Review and Experimental Study". Journal of Environmental Engineering. 139 (5): 746–756. doi:10.1061/(ASCE)EE.1943-7870.0000662.
  8. Tabor, Matthew L.; Newman, Derrick; Whelton, Andrew J. (September 16, 2014). "Stormwater Chemical Contamination Caused by Cured-in-Place Pipe (CIPP) Infrastructure Rehabilitation Activities". Environmental Science & Technology. 48 (18): 10938–10947. Bibcode:2014EnST...4810938T. doi:10.1021/es5018637. PMID   25127182.
  9. Tabor, M.L., Newman, D., Whelton, A.J. (2014). ”Stormwater Chemical Contamination Caused by Cured-in-Place Pipe (CIPP) Infrastructure Rehabilitation Activities.” Environ. Sci. Technol..
  10. "University researchers" (PDF). SWRCB.ca.gov. Retrieved September 3, 2017.
  11. Currier B. (2017). ”Water Quality of Flow Through Cured-in-Place-Pipe (CIPP) FINAL REPORT", Prepared for CALTRANS, Sacramento, CA.
  12. Ra, Kyungyeon; Teimouri Sendesi, Seyedeh Mahboobeh; Howarter, John A.; Jafvert, Chad T.; Donaldson, Bridget M.; Whelton, Andrew J. (2018). "Critical Review: Surface Water and Stormwater Quality Impacts of Cured-In-Place Pipe Repairs". Journal - American Water Works Association. 110 (5): 15–32. Bibcode:2018JAWWA.110e..15R. doi: 10.1002/awwa.1042 .
  13. "Review of common construction practice finds environmental contamination, need for improved oversight and monitoring - News - Purdue University". Purdue.edu.
  14. Li, Xianzhen; al, et. (2019). "Outdoor manufacture of UV-Cured plastic linings for storm water culvert repair: Chemical emissions and residual". Environmental Pollution. 245: 1031–1040. Bibcode:2019EPoll.245.1031L. doi: 10.1016/j.envpol.2018.10.080 . PMID   30682737.
  15. Teimouri Sendesi, Seyedeh Mahboobeh; Ra, Kyungyeon; Conkling, Emily N.; Boor, Brandon E.; Nuruddin, Md.; Howarter, John A.; Youngblood, Jeffrey P.; Kobos, Lisa M.; Shannahan, Jonathan H.; Jafvert, Chad T.; Whelton, Andrew J. (2017). "Worksite Chemical Air Emissions and Worker Exposure during Sanitary Sewer and Stormwater Pipe Rehabilitation Using Cured-in-Place-Pipe (CIPP)". Environmental Science & Technology Letters. 4 (8): 325–333. Bibcode:2017EnSTL...4..325T. doi: 10.1021/acs.estlett.7b00237 .
  16. "Home". Cippsafety.org.
  17. "document on its website". Nassco.org. Retrieved March 6, 2022.
  18. "Response to NASSCO Incorporated's August 25, 2017 Public Statement" (PDF). CIPPSafety.org. Retrieved October 11, 2022.
  19. "an additional study". Nassco.org. Retrieved March 6, 2022.
  20. "Cured-in-Place-Pipe (CIPP): Inhalation and Dermal Exposure Risks Associated with Sanitary Sewer, Storm Sewer, and Drinking Water Pipe Repairs". Blogs.cdc.gov. September 26, 2017.
  21. "Cure-in-place pipe (CIPP): Additional Considerations for Municipalities" (PDF). Retrieved March 6, 2022.
  22. "Cured in Place Piping (CIPP) Webinar | National Environmental Health Association". Neha.org.
  23. "Purdue CIPP Safety Study Webinar Review: Or What Happens When Scientists Don't Know the Basics of Sewer Design or Trenchless Rehab Best Practices". Linkedin.com. Retrieved March 6, 2022.
  24. "Worker, 22, dies after being trapped in 20-inch sewer pipe in Streamwood". abc7chicago.com.
  25. "CIPP Emissions Study - Request for Proposal". Nassco.org.
  26. "NASSCO CIPP Emissions Phase 2: Evaluation of Air Emissions from Polyester Resin CIPP with Steam Cure Final Report" (PDF). NASSCO CIPP Emissions Phase 2: Evaluation of Air Emissions from Polyester Resin CIPP with Steam Cure Final Report.
  27. "Evaluation of Exposures to Styrene During Ultraviolet Cured-in-place Pipe Installation" (PDF). Retrieved February 1, 2022.
  28. "Evaluation of Exposures to Styrene during Cured-in-place Pipe Liner Preparation and during Pipe Repairs using Hot Water and Steam HHE Report No. 2019-0080-3379" (PDF). Retrieved February 1, 2022.
  29. "CURED-IN-PLACE-PIPE [CIPP]" (PDF). Retrieved December 1, 2020.
  30. Noh, Yoorae; Boor, Brandon E.; Shannahan, Jonathan H.; Troy, Cary D.; Jafvert, Chad T.; Whelton, Andrew J. (2022). "Emergency responder and public health considerations for plastic sewer lining chemical waste exposures in indoor environments". Journal of Hazardous Materials. 422: 126832. Bibcode:2022JHzM..42226832N. doi: 10.1016/j.jhazmat.2021.126832 . PMC   9614704 . PMID   34449354.
  31. Noh, Yoorae; Odimayomi, Tolulope; Teimouri Sendesi, Seyedeh Mahboobeh; Youngblood, Jeffrey P.; Whelton, Andrew J. (2022). "Environmental and human health risks of plastic composites can be reduced by optimizing manufacturing conditions". Journal of Cleaner Production. 356: 131803. Bibcode:2022JCPro.35631803N. doi: 10.1016/j.jclepro.2022.131803 .
  32. Morales, Ana C.; Tomlin, Jay M.; West, Christopher P.; Rivera-Adorno, Felipe A.; Peterson, Brianna N.; Sharpe, Steven A. L.; Noh, Yoorae; Sendesi, Seyedeh M. T.; Boor, Brandon E.; Howarter, John A.; Moffet, Ryan C.; China, Swarup; o'Callahan, Brian T.; El-Khoury, Patrick Z.; Whelton, Andrew J.; Laskin, Alexander (2022). "Atmospheric emission of nanoplastics from sewer pipe repairs". Nature Nanotechnology. 17 (11): 1171–1177. Bibcode:2022NatNa..17.1171M. doi:10.1038/s41565-022-01219-9. OSTI   1988613. PMID   36203091.