David Brower Center

Last updated
Photo of words printed on the wall at David Brower Center David Brower Center-Berkeley wall words DevSummit2018.jpg
Photo of words printed on the wall at David Brower Center

The David Brower Center is a nonprofit space located in downtown Berkeley, California, containing three floors of office space, a gallery focusing primarily on environmental and social art, conference facilities, a 178-seat theater, and a restaurant, Gather. It was named in honor of David Brower, a Berkeley native, who was the first executive director of the Sierra Club and a backer of Marion Edey’s founding of the League of Conservation Voters. [1] [2] The center is part of a larger mixed-use development, that includes the Oxford Plaza (an affordable housing complex with street level commercial space). The David Brower Center's mission is to "inspire and nurture current and future generations of leaders, with the goal of making sustainable thinking and practices mainstream."

Contents

The center is home to dozens of organizations, which occupy the three floors of office space, including Earth Island Institute, Friends of the Earth (both of which were founded by David Brower), as well as Equity Community Builders, Impact Hub, Strategen, and several others.

In addition to housing nonprofit organizations, since 2009, the Hazel Wolf Gallery within the Brower Center has highlighted the work of many artists, including Sebastião Salgado, Daniel McCormick, David Liittschwager, Laura Cunningham, Isabella Kirkland, Chris Jordan, David Maisel, Jeffrey Long, Bill Curtsinger, Joseph Holmes, and more recently, Richard Misrach and Douglas Gayeton.

Building Design

The Brower Center, which was designed by architectural studio WRT/Solomon E.T.C. (now with Mithun), completed construction and opened its doors in 2009. The center makes use of a number of sustainable technologies and design techniques that came out of a highly integrated design process including radiant heating and cooling, daylighting, shading, underfloor air distribution (UFAD), natural ventilation through operable windows, solar panels, rainwater harvesting, and a building dashboard. [3] In 2010, the center received a LEED Platinum rating from the US Green Building Council. [4] An occupant survey conducted by the Center for the Built Environment in the spring of 2010 indicated that the general satisfaction of the building is 1.78 out of a scale of -3 (very dissatisfied) to +3 (very satisfied). [5] In a post occupancy evaluation conducted by an architecture class at the University of California, Berkeley, over half of the questionnaire respondents said that the building was inspiring in regard to sustainability. [6]

Heating and Cooling

The primary method for space conditioning is a hydronic, in-slab radiant system that is located in the exposed concrete ceiling slabs on the 2nd, 3rd, and 4th floors. [5] These systems are often referred to as thermally activated building systems. The radiant system is used for both heating and cooling. To chill the water in the radiant system, the system makes use of a cooling tower located on the roof. Because the radiant system has a large surface area and high thermal mass, it is able to use warmer chilled water temperatures than a typical cooling system. This makes it a good match for non-compressor-based cooling. The cooling tower is able to chill the supply water using only the outdoor air, without any chiller.

Daylighting

The offices in the David Brower Center have almost 100% continuous daylighting autonomy. [1] This metric indicates the percentage of occupied hours that can rely purely on sunlight for lighting the space. The building achieves this continuous daylight autonomy through the use of light shelves and glazed facades on the south and east sides of the building, in addition to a fairly narrow building depth of 8.2 metres (27 ft). The heights of individual floors were driven by daylight availability and programmatic requirements. The ground floor, which has reduced daylight availability due to surrounding site obstructions, has the highest floor-to-floor height, while the top floor, which is partially daylit from roof-level skylights, has the lowest floor-to-floor height. [7]

Shading and Solar Panels

Lining the façade of the David Brower Center are fixed exterior aluminum louvers. [7] These louvers block the direct sun and minimize heat gains within the building. In addition to the exterior shading devices, occupants can make further adjustments from within the building using manually-operated interior roller fabric shades above each window.

On top of the David Brower Center, there is a 68 kilowatts (91 hp) photovoltaic array that offsets approximately 35 percent of the building's electricity energy demand. [1] The solar panels are located on the northern and southern edges of the roof parapet, and double as an awning for the southern façade to reduce solar heat gain. The PV array is orientation is design for maximum exposure to daylight.

Building Structure

The Brower Center is designed to withstand seismic activity by allowing the structure to flex without incurring serious deformation. This is done through the combination of horizontally post-tensioned moment frames with a vertically post-tensioned core. [1] The core comprises uniformly arrayed columns and two centrally located, C-shaped, walls. [8] The entire structure is supported by a mat foundation.

All concrete used in the building structure contains slag, a byproduct of steel manufacturing. Slag is used to substitute a portion of the Portland cement (70% in the foundations and 50% in the superstructure). [1] The addition of slag reduced an estimated 5000 tons of CO2 emissions from the concrete production. [8]

Related Research Articles

A Trombe wall is a massive equator-facing wall that is painted a dark color in order to absorb thermal energy from incident sunlight and covered with a glass on the outside with an insulating air-gap between the wall and the glaze. A Trombe wall is a passive solar building design strategy that adopts the concept of indirect-gain, where sunlight first strikes a solar energy collection surface in contact with a thermal mass of air. The sunlight absorbed by the mass is converted to thermal energy (heat) and then transferred into the living space.

<span class="mw-page-title-main">Passive solar building design</span> Architectural engineering that uses the Suns heat without electric or mechanical systems

In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.

<span class="mw-page-title-main">Daylighting (architecture)</span> Practice of placing openings and reflective surfaces so that sunlight can provide internal lighting

Daylighting is the practice of placing windows, skylights, other openings, and reflective surfaces so that direct or indirect sunlight can provide effective internal lighting. Particular attention is given to daylighting while designing a building when the aim is to maximize visual comfort or to reduce energy use. Energy savings can be achieved from the reduced use of artificial (electric) lighting or from passive solar heating. Artificial lighting energy use can be reduced by simply installing fewer electric lights where daylight is present or by automatically dimming or switching off electric lights in response to the presence of daylight – a process known as daylight harvesting.

<span class="mw-page-title-main">League of Conservation Voters</span> Environmental advocacy organization in Washington, D.C., United States

The League of Conservation Voters (LCV) is an American environmental advocacy group. LCV says that it "advocates for sound environmental laws and policies, holds elected officials accountable for their votes and actions, and elects pro-environment candidates." The organization pursues its goals through voter education, voter mobilization, and direct contributions to political candidates. LCV includes 29 state affiliates. LCV was founded in 1970 by environmentalist Marion Edey, with support from David Brower. The group's current president is Gene Karpinski. It is headquartered in Washington, D.C., and has over two million members.

<span class="mw-page-title-main">Basement</span> Below-ground floor of a building

A basement or cellar is one or more floors of a building that are completely or partly below the ground floor. Especially in residential buildings, it often is used as a utility space for a building, where such items as the furnace, water heater, breaker panel or fuse box, car park, and air-conditioning system are located; so also are amenities such as the electrical system and cable television distribution point. In cities with high property prices, such as London, basements are often fitted out to a high standard and used as living space.

<span class="mw-page-title-main">Louver</span> Window protection with horizontal angled slats

A louver or louvre is a window blind or shutter with horizontal slats that are angled to admit light and air, but to keep out rain and direct sunshine. The angle of the slats may be adjustable, usually in blinds and windows, or fixed.

<span class="mw-page-title-main">Underfloor heating</span> Form of central heating and cooling

Underfloor heating and cooling is a form of central heating and cooling that achieves indoor climate control for thermal comfort using hydronic or electrical heating elements embedded in a floor. Heating is achieved by conduction, radiation and convection. Use of underfloor heating dates back to the Neoglacial and Neolithic periods.

Pearl River Tower is a 71-story, 309.6 m (1,016 ft), clean technology neofuturistic skyscraper at the junction of Jinsui Road/Zhujiang Avenue West, Tianhe District, Guangzhou, China. The tower's architecture and engineering were performed by Skidmore, Owings & Merrill with Adrian D. Smith and Gordon Gill as architects. Ground broke on the tower on 8 September 2006 and construction was completed in March 2011. It is intended for office use and is partially occupied by the China National Tobacco Corporation.

A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements. There are two types of chilled beams, a Passive Chilled Beam (PCB) and an Active Chilled Beam (ACB). They both consist of pipes of water (fin-and-tube) that pass through a heat exchanger contained in a case suspended from, or recessed in, the ceiling. As the beam cools the air around it, the air becomes denser and falls to the floor. It is replaced by warmer air moving up from below, causing a constant passive air movement called convection, to cool the room. The active beam consists of air duct connections, induction nozzles, hydronic heat transfer coils, supply outlets and induced air inlets. It contains an integral air supply that passes through nozzles, and induces air from the room to the cooling coil. For this reason, it has a better cooling capacity than the passive beam. Instead, the passive beam provides space cooling without the use of a fan and it is mainly done by convection. Passive beams can be either exposed or recessed. The passive approach can provide higher thermal comfort levels, while the active approach uses the momentum of ventilation air that enters at relatively high velocity to induce the circulation of room air through the unit. A chilled beam is similar in appearance to a VRF unit.

<span class="mw-page-title-main">Architectural light shelf</span> Architectural lighting feature

A light shelf is a horizontal surface that reflects daylight deep into a building. Light shelves are placed above eye-level and have high-reflectance upper surfaces, which reflect daylight onto the ceiling and deeper into the space.

<span class="mw-page-title-main">Council House 2</span> Office in Melbourne, Australia

Council House 2 (also known as CH2), is an office building located at 240 Little Collins Street in the Melbourne central business district, Australia. It is used by the City of Melbourne council, and in April 2005, became the first purpose-built office building in Australia to achieve a maximum Six Green Star rating, certified by the Green Building Council of Australia. CH2 officially opened in August 2006.

HVAC is a major sub discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and energy efficiency. The discipline of HVAC includes a large number of specialized terms and acronyms, many of which are summarized in this glossary.

<span class="mw-page-title-main">Underfloor air distribution</span>

Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets, located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

<span class="mw-page-title-main">Tower at PNC Plaza</span> High-rise building in Pittsburgh, Pennsylvania

The Tower at PNC Plaza is a 33-story skyscraper in Pittsburgh, Pennsylvania. It is the corporate headquarters of the PNC Financial Services Group and has approximately 800,000 square feet (74,000 m2), standing 33 stories tall. Nearby buildings totaling 37,000 square feet (3,400 m2), were purchased by PNC and deconstructed to make space for the Tower at PNC Plaza. It is located at the intersection of Fifth Avenue and Wood Street, where PNC and its predecessors have been based since 1858.

<span class="mw-page-title-main">Green Factory</span> Office Building in Seongnam, South Korea

The Green Factory is an office building located in Bundang-gu Seongnam-si of South Korea, and serves as the headquarters of Naver Corporation, a Korean internet content service company. The building was completed in March 2010, with 27 floors above ground and 7 floors underground.

<span class="mw-page-title-main">Swanston Academic Building</span> Education in Victoria, Australia

The Swanston Academic building is an RMIT building designed by the architecture firm Lyons and is located on Swanston Street in Melbourne across from Peter Corrigan designed building 8 and ARM's Storey Hall. Construction began in September 2010 and was completed in September 2012. The budget for the SAB was $200,000,000. The new building contains 35,000 square metres (380,000 sq ft) of floor space, is 11 storeys high and provides 6 large lecture theatres for students. The colourful building is intended to reflect the cities surroundings in the façade. “The idea is to wear the ‘cloak’ of the city”.

<span class="mw-page-title-main">The Terry Thomas Building</span> Office building in Seattle, Washington

The Terry Thomas Building, located in the South Lake Union neighborhood of Seattle, Washington is a sustainable, LEED-certified office building completed in 2008. The Terry Thomas is Seattle's first commercial office building structure developed in decades without central air conditioning. It was designed by Seattle-based architectural firm Weber Thompson, who also designed the interiors of the building and use it as their headquarters.

<span class="mw-page-title-main">Radiant heating and cooling</span> Category of HVAC technologies

Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", "embedded surface systems", "thermally active building systems", and infrared heaters. According to some definitions, a technology is only included in this category if radiation comprises more than 50% of its heat exchange with the environment; therefore technologies such as radiators and chilled beams are usually not considered radiant heating or cooling. Within this category, it is practical to distinguish between high temperature radiant heating, and radiant heating or cooling with more moderate source temperatures. This article mainly addresses radiant heating and cooling with moderate source temperatures, used to heat or cool indoor environments. Moderate temperature radiant heating and cooling is usually composed of relatively large surfaces that are internally heated or cooled using hydronic or electrical sources. For high temperature indoor or outdoor radiant heating, see: Infrared heater. For snow melt applications see: Snowmelt system.

<span class="mw-page-title-main">David and Lucile Packard Foundation Headquarters</span> Office in California, United States

The David and Lucile Packard Foundation Headquarters is the corporate headquarters of the David and Lucile Packard Foundation, located in Los Altos, California. The Packard Foundation was created in 1964 by David Packard and his wife Lucile Salter Packard, one of the top 100 grant-making foundations in the United States, with the goals of improving the lives of children, enabling the creative pursuit of science, advancing reproductive health, and conserving and restoring the Earth’s natural systems. The David and Lucile Packard Foundation Headquarters is designed by EHDD to be the largest net zero energy building in California, and it has successfully reduced the energy use by 65% over conventional buildings.

Cooling load is the rate at which sensible and latent heat must be removed from the space to maintain a constant space dry-bulb air temperature and humidity. Sensible heat into the space causes its air temperature to rise while latent heat is associated with the rise of the moisture content in the space. The building design, internal equipment, occupants, and outdoor weather conditions may affect the cooling load in a building using different heat transfer mechanisms. The SI units are watts.

References

  1. 1 2 3 4 5 Gonchar, Joann. "David Brower Center". GreenSource. Retrieved 2014-11-24.
  2. "Marion Edey, Ecology Lobbyist, Is Married to Joseph Browder". The New York Times. 1972-04-24. ISSN   0362-4331 . Retrieved 2023-05-10. https://www.nytimes.com/1972/04/24/archives/marion-edey-ecology-lobbyist-is-married-to-joseph-browder.html
  3. Lovett, Mark (2012-06-08). "David Brower Center – LEED Platinum-Certified". Global Patriot. Archived from the original on 2015-09-19. Retrieved 2014-11-24.
  4. "U.S. Green Building Council | U.S. Green Building Council". Usgbc.org. Retrieved 2014-02-06.
  5. 1 2 Bauman, Fred; Webster, Tom; Zhang, Hui; Arens, Edward; Lehrer, David; Dickerhoff, Darryl; Feng, Jingjuan; Heinzerling, David; Fannon, Tiefeng; Yu, Jingjuan; Hoffmann, Sabine; Hoyt, Tyler; Pasut, Wilmer; Schiavon, Stefano; Vasudev, Janani; Kaam, Soazig (2013), Advanced Integrated Systems Technology Development, Center for the Built Environment, University of California, Berkeley
  6. Cranz, Galen; Lindsay, Georgia; Morhayim, Lusi; Lin, Annie (2013), Communicating Sustainability: A Postoccupancy Evaluation of the David Brower Center, Environment and Behavior
  7. 1 2 Zelenay, Krystyna; Perepelitza, Mark; Lehrer, David (2011), High-Performance Facades: Design Strategies and Applications in North America and Northern Europe, Center for the Built Environment, University of California, Berkeley
  8. 1 2 Stevenson, Mark; Panian, Leo (2009), Sustainability through Strength, Concrete International

37°52′10″N122°15′59″W / 37.86948°N 122.26635°W / 37.86948; -122.26635