Fixed-pattern noise

Last updated

Fixed-pattern noise (FPN) is the term given to a particular noise pattern on digital imaging sensors often noticeable during longer exposure shots where particular pixels are susceptible to giving brighter intensities above the average intensity.

Contents

Overview

FPN is a general term that identifies a temporally constant lateral non-uniformity (forming a constant pattern) in an imaging system with multiple detector or picture elements (pixels). It is characterised by the same pattern of variation in pixel-brightness occurring in images taken under the same illumination conditions in an imaging array. This problem arises from small differences in the individual responsitivity of the sensor array (including any local postamplification stages) that might be caused by variations in the pixel size, material or interference with the local circuitry. It might be affected by changes in the environment like different temperatures, exposure times, etc.

The term "fixed pattern noise" usually refers to two parameters. [1] One is the dark signal non-uniformity (DSNU), which is the offset from the average across the imaging array at a particular setting (temperature, integration time) but no external illumination and the photo response non-uniformity (PRNU), which describes the gain or ratio between optical power on a pixel versus the electrical signal output. The latter is often simplified as a single value measured at e.g. 50% saturation level, implying a linear approximation of the not perfectly linear photo response non-linearity (PRNL). [2] Often PRNU as defined above is subdivided in pure "(offset) FPN" which is the part not dependent on temperature and integration time, and the integration time and temperature dependent "DSNU".

Sometimes pixel noise [3] as the average deviation from the array average under different illumination and temperature conditions is specified. Pixel noise therefore gives a number (commonly expressed in rms) that identifies FPN in all permitted imaging conditions, which might strongly deteriorate if additional electrical gain (and noise) is included. Recent uses for PRNU include measures to fighting motion picture piracy.

In practice, a long exposure (integration time) emphasizes the inherent differences in pixel response so they may become a visible defect, degrading the image. Although FPN does not change appreciably across a series of captures, it may vary with integration time, imager temperature, imager gain and incident illumination, it is not expressed in a random (uncorrelated or changing) spatial distribution, occurring only at certain, fixed pixel locations.

Suppression of FPN

FPN is commonly suppressed by flat-field correction (FFC) that uses DSNU and PRNU to linearly interpolate and reduce the local photo response (non-uniform PRNL) to the array average. Hence, two exposures with an equal illumination across the array are necessary (one without light and one close to saturation) to obtain the values. Note that this correction usually is very sensitive to modifications of the system parameters (i.e., exposure time, temperature). The main challenge is to generate a flat field illumination for short time exposures and wavelengths, to avoid speckle (in monochromatic light conditions) and statistical fluctuations of the light stream that become most obvious at short integration times.

Many patents and methods exist to reduce or eliminate fixed pattern noise in digital imagers [ citation needed ] . Specific for the suppression of "offset FPN" as defined above, on-chip techniques for suppression exist, such as correlated double sampling.

See also

Related Research Articles

<span class="mw-page-title-main">Charge-coupled device</span> Device for the movement of electrical charge

A charge-coupled device (CCD) is an integrated circuit containing an array of linked, or coupled, capacitors. Under the control of an external circuit, each capacitor can transfer its electric charge to a neighboring capacitor. CCD sensors are a major technology used in digital imaging.

<span class="mw-page-title-main">Photodiode</span> Converts light into current

A photodiode is a semiconductor diode sensitive to photon radiation, such as visible light, infrared or ultraviolet radiation, X-rays and gamma rays. It produces an electrical current when it absorbs photons. This can be used for detection and measurement applications, or for the generation of electrical power in solar cells. Photodiodes are used in a wide range of applications throughout the electromagnetic spectrum from visible light photocells to gamma ray spectrometers.

Gamma correction or gamma is a nonlinear operation used to encode and decode luminance or tristimulus values in video or still image systems. Gamma correction is, in the simplest cases, defined by the following power-law expression:

<span class="mw-page-title-main">Multi-exposure HDR capture</span> Technique to capture HDR images and videos

In photography and videography, multi-exposure HDR capture is a technique that creates high dynamic range (HDR) images by taking and combining multiple exposures of the same subject matter at different exposure levels. Combining multiple images in this way results in an image with a greater dynamic range than what would be possible by taking one single image. The technique can also be used to capture video by taking and combining multiple exposures for each frame of the video. The term "HDR" is used frequently to refer to the process of creating HDR images from multiple exposures. Many smartphones have an automated HDR feature that relies on computational imaging techniques to capture and combine multiple exposures.

<span class="mw-page-title-main">Vignetting</span> Reduction of an images brightness or saturation toward the periphery compared to the image center

In photography and optics, vignetting is a reduction of an image's brightness or saturation toward the periphery compared to the image center. The word vignette, from the same root as vine, originally referred to a decorative border in a book. Later, the word came to be used for a photographic portrait that is clear at the center and fades off toward the edges. A similar effect is visible in photographs of projected images or videos off a projection screen, resulting in a so-called "hotspot" effect.

A spectroradiometer is a light measurement tool that is able to measure both the wavelength and amplitude of the light emitted from a light source. Spectrometers discriminate the wavelength based on the position the light hits at the detector array allowing the full spectrum to be obtained with a single acquisition. Most spectrometers have a base measurement of counts which is the un-calibrated reading and is thus impacted by the sensitivity of the detector to each wavelength. By applying a calibration, the spectrometer is then able to provide measurements of spectral irradiance, spectral radiance and/or spectral flux. This data is also then used with built in or PC software and numerous algorithms to provide readings or Irradiance (W/cm2), Illuminance, Radiance (W/sr), Luminance (cd), Flux, Chromaticity, Color Temperature, Peak and Dominant Wavelength. Some more complex spectrometer software packages also allow calculation of PAR μmol/m2/s, Metamerism, and candela calculations based on distance and include features like 2- and 20-degree observer, baseline overlay comparisons, transmission and reflectance.

<span class="mw-page-title-main">Flat-field correction</span> Digital imaging calibration technique

Flat-field correction (FFC) is a digital imaging technique to mitigate the image detector pixel-to-pixel sensitivity and distortions in the optical path. It is a standard calibration procedure in everything from personal digital cameras to large telescopes.

<span class="mw-page-title-main">Image noise</span> Visible interference in an image

Image noise is random variation of brightness or color information in images, and is usually an aspect of electronic noise. It can be produced by the image sensor and circuitry of a scanner or digital camera. Image noise can also originate in film grain and in the unavoidable shot noise of an ideal photon detector. Image noise is an undesirable by-product of image capture that obscures the desired information. Typically the term “image noise” is used to refer to noise in 2D images, not 3D images.

A camera raw image file contains unprocessed or minimally processed data from the image sensor of either a digital camera, a motion picture film scanner, or other image scanner. Raw files are so named because they are not yet processed, and contain large amounts of potentially redundant data. Normally, the image is processed by a raw converter, in a wide-gamut internal color space where precise adjustments can be made before conversion to a viewable file format such as JPEG or PNG for storage, printing, or further manipulation. There are dozens of raw formats in use by different manufacturers of digital image capture equipment.

A staring array, also known as staring-plane array or focal-plane array (FPA), is an image sensor consisting of an array of light-sensing pixels at the focal plane of a lens. FPAs are used most commonly for imaging purposes, but can also be used for non-imaging purposes such as spectrometry, LIDAR, and wave-front sensing.

Demosaicing, also known as color reconstruction, is a digital image processing algorithm used to reconstruct a full color image from the incomplete color samples output from an image sensor overlaid with a color filter array (CFA) such as a Bayer filter. It is also known as CFA interpolation or debayering.

<span class="mw-page-title-main">Image sensor</span> Device that converts images into electronic signals

An image sensor or imager is a sensor that detects and conveys information used to form an image. It does so by converting the variable attenuation of light waves into signals, small bursts of current that convey the information. The waves can be light or other electromagnetic radiation. Image sensors are used in electronic imaging devices of both analog and digital types, which include digital cameras, camera modules, camera phones, optical mouse devices, medical imaging equipment, night vision equipment such as thermal imaging devices, radar, sonar, and others. As technology changes, electronic and digital imaging tends to replace chemical and analog imaging.

The following are common definitions related to the machine vision field.

The merits of digital versus film photography were considered by photographers and filmmakers in the early 21st century after consumer digital cameras became widely available. Digital photography and digital cinematography have both advantages and disadvantages relative to still film and motion picture film photography. In the 21st century, photography came to be predominantly digital, but traditional photochemical methods continue to serve many users and applications.

<span class="mw-page-title-main">Dark-frame subtraction</span> Method of reducing image noise in long-exposure photographs

In digital photography, dark-frame subtraction is a way to reduce image noise in photographs shot with long exposure times, at high ISO sensitivity or at high temperatures. It takes advantage of two components of image noise that remain the same from one shot to the next, dark current and fixed-pattern noise. Noise from the image sensor include hot pixels, which light up more brightly than surrounding pixels. The technique works by taking a picture with the shutter closed and subtracting that electronically from the original photo exhibiting the noise.

<span class="mw-page-title-main">Image sensor format</span> Shape and size of a digital cameras image sensor

In digital photography, the image sensor format is the shape and size of the image sensor.

Optical heterodyne detection is a method of extracting information encoded as modulation of the phase, frequency or both of electromagnetic radiation in the wavelength band of visible or infrared light. The light signal is compared with standard or reference light from a "local oscillator" (LO) that would have a fixed offset in frequency and phase from the signal if the latter carried null information. "Heterodyne" signifies more than one frequency, in contrast to the single frequency employed in homodyne detection.

<span class="mw-page-title-main">RawTherapee</span> Raw photo processing software

RawTherapee is application software for processing photographs in raw image formats, as created by many digital cameras. It comprises a subset of image editing operations specifically aimed at non-destructive post-production of raw photos and is primarily focused on improving a photographer's workflow by facilitating the handling of large numbers of images. It is notable for the advanced control it gives the user over the demosaicing and developing process. It is cross-platform, with versions for Microsoft Windows, macOS and Linux.

An oversampled binary image sensor is an image sensor with non-linear response capabilities reminiscent of traditional photographic film. Each pixel in the sensor has a binary response, giving only a one-bit quantized measurement of the local light intensity. The response function of the image sensor is non-linear and similar to a logarithmic function, which makes the sensor suitable for high dynamic range imaging.

Photo response non-uniformity, pixel response non-uniformity, or PRNU, is a form of fixed-pattern noise related to digital image sensors, as used in cameras and optical instruments. Both CCD and CMOS sensors are two-dimensional arrays of photosensitive cells, each broadly corresponding to an image pixel. Due to the non-uniformity of image sensors, each cell responds with a different voltage level when illuminated with a uniform light source, and this leads to luminance inaccuracy at the pixel level.

References

  1. Electronic Shuttering for High Speed CMOS Machine Vision Applications http://www.automaatioseura.fi/jaostot/mvn/mvn2007/parameter.html Archived 2009-10-15 at the Wayback Machine
  2. "Standard for Measurement and Presentation of Specifications for Machine Vision Sensors and Cameras" (PDF). emva.org. European machine vision association.
  3. Commercial Sensor Survey Radiation Testing Progress Report http://trs-new.jpl.nasa.gov/dspace/bitstream/2014/40825/1/08-22.pdf Archived 2009-04-14 at the Wayback Machine

Notes