Life Safety Code

Last updated

The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.

Contents

Despite its title, the standard is not a legal code, is not published as an instrument of law, and has no statutory authority in its own right. However, it is deliberately crafted with language suitable for mandatory application to facilitate adoption into law by those empowered to do so.

The bulk of the standard addresses "those construction, protection, and occupancy features necessary to minimize danger to life from the effects of fire, including smoke, heat, and toxic gases created during a fire.". [1] The standard does not address the "general fire prevention or building construction features that are normally a function of fire prevention codes and building codes". [2]

History

The Life Safety Code was originated in 1913 by the Committee on Safety to Life (one of the NFPA's more than 200 committees). As noted in the 1991 Life Safety Code Handbook; "...the Committee devoted its attention to a study of notable fires involving loss of life and to analyzing the causes of that loss of life. This work led to the preparation of standards for the construction of stairways,fire escapes, and similar structures; for fire drills in various occupancies and for the construction and arrangement of exit facilities for factories, schools and other occupancies, which form the basis of the present Code." [3] This study became the basis for two early NFPA publications, "Outside Stairs for Fire Exits" (1916) and "Safeguarding Factory Workers from Fire" (1918).

In 1921 the Committee on Safety to Life expanded and the publication they generated in 1927 became known as the Building Exits Code. New editions were published in 1929, 1934, 1936, 1938, 1942 and 1946.

After a disastrous series of fires between 1942 and 1946, including the Cocoanut Grove Nightclub fire in Boston, which claimed the lives of 492 people and the Winecoff Hotel fire in Atlanta which claimed 119 lives, the Building Exits Code began to be utilized as potential legal legislation. The verbiage of the code, however, was intended for building contractors and not legal statutes, so the NFPA decided to re-edit the Code and some revisions appeared in the 1948, 1949, 1951 and 1952 publications. The editions published in 1957, 1958, 1959, 1960, 1961 and 1963 refined the verbiage and presentation even further.

In 1955 the NPFA101 was broken into three separate documents, NFPA101B (covering nursing homes) and NFPA101C (covering interior finishes). NFPA101C was revised once in 1956 before both publications were withdrawn and pertinent passages re-incorporated back into the main body.

The Committee on Safety to Life was restructured in 1963 and the first publication in 1966 was a complete revision. The title was changed from Building Exits Code to Code for Safety to Life from Fire in Buildings and Structures. The final revision to all "code language" (legalese) was made and it was decided that the Code would be revised and republished on a three-year schedule. New editions were subsequently published in 1967, 1970, 1973 and 1976.

The Committee was reorganized again in 1977 and the 1981 edition of the Code featured major editorial and structural changes that reflect the organization of the modern Code.

Ongoing amendment

Codes produced by NFPA are continually updated to incorporate new technologies as well as lessons learned from actual fire experiences.

The fire at The Station nightclub in 2003, which claimed the lives of 100 and injured more than 200, resulted in swift attention to several amendments specific to nightclubs and large crowds.

Current code

The Life Safety Code is unusual among safety codes in that it applies to existing structures as well as new structures. When a Code revision is adopted into local law, existing structures may have a grace period before they must comply, but all structures must comply with code. In some cases, the authority having jurisdiction can simply permit previously approved features to be used under specified conditions. In other cases, the local law amends the Code to omit undesired sections prior to its adoption.

When some or all of the Code is adopted as regulations in a jurisdiction, it can be enforced by inspectors from local zoning boards, fire departments, building inspectors, fire marshals or other bodies and authorities having jurisdiction.

In particular, the Life Safety Code deals with hazards to human life in buildings, public and private conveyances and other human occupancies, but only when permanently fixed to a foundation, attached to a building, or permanently moored for human habitation. [4] Regardless of official adoption as regulations, Life Safety Code provides a valuable source for determination of liability in accidents, and many codes and related standards are sponsored by insurance companies.

The Life Safety Code is coordinated with hundreds of other building codes and standards such as National Electrical Code NFPA 70, fuel-gas, mechanical, plumbing (for sprinklers and standpipes), energy and fire codes.

Normally, the Life Safety Code is used by architects and designers of vehicles and vessels used for human occupancy. Since the Life Safety Code is a valuable source for determining liability in accidents, it is also used by insurance companies to evaluate risks and set rates, not to mention assessment of compliance after an incident.

In the United States, the words Life Safety Code and NFPA 101 are registered trademarks of NFPA. All or part of the NFPA's Life Safety Code are adopted as local regulations throughout the country.

Sample sections

This listing of chapters from the 2009 edition [5] shows the scope of the Code.

Beyond the policies, core definitions and topical requirements of chapters 1–11, chapters 12–42 address the specific requirements for each listed class of occupancy, making reference to Chapters 1–11, as well as other codes.

The Code and corresponding Handbook also include several supplemental publications including:

See also

Related Research Articles

The Station nightclub fire occurred on the evening of February 20, 2003, in West Warwick, Rhode Island, United States, killing 100 people and injuring 230. The fire was caused by pyrotechnics set off by the tour manager of the evening's headlining band, Great White, which ignited flammable acoustic foam in the walls and ceilings surrounding the stage. It reached flashover within one minute, causing all combustible materials to burn. Intense black smoke engulfed the club within two minutes. Video footage of the fire shows its ignition, rapid growth, the billowing smoke that quickly made escape impossible, and blocked egress that further hindered evacuation.

<span class="mw-page-title-main">Fire sprinkler system</span> Fire protection method

A fire sprinkler system is an active fire protection method, consisting of a water supply system, providing adequate pressure and flowrate to a water distribution piping system, onto which fire sprinklers are connected. Although historically only used in factories and large commercial buildings, systems for homes and small buildings are now available at a cost-effective price. Fire sprinkler systems are extensively used worldwide, with over 40 million sprinkler heads fitted each year. Even though Fire Sprinkler Systems are a Life Saving System and are not designed to protect the building, 96% of buildings that had fires and were completely protected by fire sprinkler systems were controlled by the fire sprinklers alone.

<span class="mw-page-title-main">National Electrical Code</span> Electrical wiring standard

The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association. Despite the use of the term "national", it is not a federal law. It is typically adopted by states and municipalities in an effort to standardize their enforcement of safe electrical practices. In some cases, the NEC is amended, altered and may even be rejected in lieu of regional regulations as voted on by local governing bodies.

<span class="mw-page-title-main">National Fire Protection Association</span> International nonprofit organization

The National Fire Protection Association (NFPA) is an international nonprofit organization devoted to eliminating death, injury, property and economic loss due to fire, electrical and related hazards. As of 2018, the NFPA claims to have 50,000 members and 9,000 volunteers working with the organization through its 250 technical committees.

<span class="mw-page-title-main">Fire safety</span> Practices to reduce the results of fire

Fire safety is the set of practices intended to reduce the destruction caused by fire. Fire safety measures include those that are intended to prevent the ignition of an uncontrolled fire and those that are used to limit the development and effects of a fire after it starts.

<span class="mw-page-title-main">Fire sprinkler</span> Component that discharges water to protect buildings

A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly designed and maintained fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.

<span class="mw-page-title-main">Fire escape</span> Type of emergency exit for tall buildings

A fire escape is a special kind of emergency exit, usually mounted to the outside of a building or occasionally inside but separate from the main areas of the building. It provides a method of escape in the event of a fire or other emergency that makes the stairwells inside a building inaccessible. Fire escapes are most often found on multiple-story residential buildings, such as apartment buildings. At one time, they were a very important aspect of fire safety for all new construction in urban areas; more recently, however, they have fallen out of common use. This is due to the improved building codes incorporating fire detectors, technologically advanced fire fighting equipment, which includes better communications and the reach of fire fighting ladder trucks, and more importantly fire sprinklers. The international building codes and other authoritative agencies have incorporated fire sprinklers into multi-story buildings below 15 stories and not just skyscrapers.

<span class="mw-page-title-main">Fire door</span> Fire resistant door

A fire door is a door with a fire-resistance rating used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship. In North American building codes, it, along with fire dampers, is often referred to as a closure, which can be derated compared against the fire separation that contains it, provided that this barrier is not a firewall or an occupancy separation. In Europe national standards for fire doors have been harmonised with the introduction of the new standard EN 16034, which refers to fire doors as fire-resisting door sets. Starting September 2016, a common CE marking procedure was available abolishing trade barriers within the European Union for these types of products. In the UK, it is Part B of the Building Regulations that sets out the minimum requirements for the fire protection that must be implemented in all dwellings this includes the use of fire doors. All fire doors must be installed with the appropriate fire resistant fittings, such as the frame and door hardware, for it to fully comply with any fire regulations.

The International Building Code (IBC) is a model building code developed by the International Code Council (ICC). It has been adopted for use as a base code standard by most jurisdictions in the United States. The IBC addresses both health and safety concerns for buildings based upon prescriptive and performance related requirements. The IBC is fully compatible with all other published ICC codes. The code provisions are intended to protect public health and safety while avoiding both unnecessary costs and preferential treatment of specific materials or methods of construction. However, a 2019 New York Times story revealed a secret agreement with the National Association of Home Builders that allowed the industry group, which represents the construction industry, to limit improvements in the code that would make buildings more environmentally sustainable and resistant to natural disasters, prompting a congressional investigation. The ICC, in response to a Congressional inquiry, vehemently denied the characterization of the agreement, noting, "While home builders are among [our code development] partners, they do not have disproportionate control of the Code Council's model code development process. On the contrary, volunteer government officials with experience and expertise exercise by far the most control in the process."

NFPA 70E, titled Standard for Electrical Safety in the Workplace, is a standard of the National Fire Protection Association (NFPA). The document covers electrical safety requirements for employees. The NFPA is best known for publishing the National Electrical Code.

<span class="mw-page-title-main">Fire protection</span> Measures that prevent or mitigate unwanted fire

Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. It involves the study of the behaviour, compartmentalisation, suppression and investigation of fire and its related emergencies, as well as the research and development, production, testing and application of mitigating systems. In structures, be they land-based, offshore or even ships, the owners and operators are responsible to maintain their facilities in accordance with a design-basis that is rooted in laws, including the local building code and fire code, which are enforced by the authority having jurisdiction.

<span class="mw-page-title-main">Fire alarm system</span> A system, that works using multiple devices to warn of an emergency.

A fire alarm system warns people when smoke, fire, carbon monoxide or other fire-related or general notification emergencies are detected. These alarms may be activated automatically from smoke detectors and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points or pull stations. Alarms can be either motorized bells or wall mountable sounders or horns. They can also be speaker strobes which sound an alarm, followed by a voice evacuation message which warns people inside the building not to use the elevators. Fire alarm sounders can be set to certain frequencies and different tones including low, medium, and high, depending on the country and manufacturer of the device. Most fire alarm systems in Europe sound like a siren with alternating frequencies. Fire alarm electronic devices are known as horns in the United States and Canada and can be either continuous or set to different codes. Fire alarm warning devices can also be set to different volume levels.

<span class="mw-page-title-main">Passive fire protection</span> Component or system to passively prevent the spread of fire

Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor-ceilings and roofs, fire doors, windows, and wall assemblies, fire-resistant coatings, and other fire and smoke control assemblies. Passive fire protection systems can include active components such as fire dampers.

Within the context of building construction and building codes, "occupancy" refers to the use, or intended use, of a building, or portion of a building, for the shelter or support of persons, animals or property. A closely related meaning is the number of units in such a building that are rented, leased, or otherwise in use. Lack of occupancy, in this sense, is known as "vacancy".

Heat and smoke vents are installed in buildings as an active fire protection measure. They are openings in the roof which are intended to vent the heat and smoke developed by a fire inside the building by the action of buoyancy, such that they are known as "gravity vents".

<span class="mw-page-title-main">Combustibility and flammability</span> Ability to easily ignite in air at ambient temperatures

A combustible material is something that can burn in air. A combustible material is flammable if it ignites easily at ambient temperatures. In other words, a combustible material ignites with some effort and a flammable material catches fire immediately on exposure to flame.

The NFPA 72 is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.

The Fire Sprinkler Incentive Act (FSIA) is the name of a piece of legislation that has been introduced in both the House and the Senate since 2003. The legislation would amend the 1986 Internal Revenue Code by classifying fire sprinkler retrofits as either a Section 179 depreciation deduction or a fifteen-year property for purposes of depreciation. Currently the tax depreciation time for commercial property is 39 years and 27.5 for residential.

The California Building Standards Code is the building code for California, and Title 24 of the California Code of Regulations (CCR). It is maintained by the California Building Standards Commission which is granted the authority to oversee processes related to the California building codes by California Building Standards Law. The California building codes under Title 24 are established based on several criteria: standards adopted by states based on national model codes, national model codes adapted to meet California conditions, and standards passed by the California legislature that address concerns specific to California.

<span class="mw-page-title-main">Exit sign</span> Sign indicating the location of the nearest emergency exit

An exit sign is a pictogram or short text in a public facility denoting the location of the closest emergency exit to be used in case of fire or other emergency that requires rapid evacuation. Most relevant codes require exit signs to be permanently lit.

References

  1. NFPA 101, Life Safety Code 2006 edition NFPA, 1.1.2
  2. NFPA 101, Life Safety Code 2006 edition NFPA, 1.1.6
  3. Life Safety Code Handbook, National Fire Protection Association, 1991. Lathrop, James K. Ed. NFPA
  4. NFPA 101 Section 11.6
  5. NFPA 101 Life Safety Code 2009 edition, National Fire Protection Association, July 2008