Microdispensing

Last updated

Microdispensing is the technique of producing liquid media dosages in volumes of less than one microlitre. The continuing miniaturization in almost all technical areas creates constant challenges for industry, development and research facilities. Microdispensing is one of those challenges. Ever smaller amounts of adhesive, liquid, oil, grease and a multitude of other media must be dispensed reliably and accurately in dosage and placement with short cycle times. The precise positioning and quantity of fluids such as glue, reagents or any other substance has a great influence on the overall quality of a medical device. A few examples are:

Contents

Microdispensing is also used in non-medical applications, like on-demand soda flavoring (the Coca-Cola Freestyle and Pepsi Spire), inkjet printing, and 3-D printing.

Dispensing techniques

There are two basic types of dispensing techniques: classic contact dispensing and non-contact dispensing.

Contact dispensing

In contact dispensing, the drop forms at the exit of a nozzle, and is deposited by contact, while the drop is still on the nozzle. The technique is as old as the wish to divide a medium, stored in a big container, into smaller amounts. A good example for this is applying adhesive with a tube: To apply the adhesive requires contact between the tip of the tube and the part for the bead of adhesive to be transferred. This method has disadvantages:

Despite all of these disadvantages, contact dispensing is still used in the majority of automated processes today, because of:

Typical technologies for contact dispensing

Gear pump

Pressure-time systems

Non-contact dispensing (Jetting)

In non-contact dispensing, the drop also forms at the end of a nozzle, but far enough away from the target area that the drop separates from the nozzle before it hits. This, too, is a very old technique, as old as squirting liquid from a tube.

Because of increasing requirements in regards to cycle time and accuracy in almost all areas of production, non-contact dispensing is constantly gaining importance. A good example for this is the attachment of very small electronic parts (SMD parts) onto printed circuit boards and substrates. For this, the part carrier only needs to be positioned in one plane - after that the adhesive can be transferred without contact. The following examples show the advantages of non-contact dispensing:

Non-contact dispensing can be divided in two different methods:

Jet-forming dispensing


Jet-forming dispensing exists when the flow velocity of a medium at the nozzle exit is high enough that the effects of gravitation and surface tension on the separation of the fluid from the nozzle are of secondary importance. This state is characterized by the Weber number:

where

: Fluid density (kg/m 3)
: Jet velocity (m/s)
: Nozzle diameter (m)
: Surface tension (N/m)

The physical border line between drop- and jet-forming is around a Weber-number of 8. At this point the dynamic pressure of the flowing medium exceeds the pressure from the surface tension of the drop, which therefore sticks to the nozzle. This transitional stage can be demonstrated at a water tap by gradually increasing the flow, going from the dropping status until a continuous water jet has formed. The Weber-number in this case is, however, clearly above 8, because of the jet exit conditions of the nozzle.

By using the Weber-number, the theoretical lower limit of the mass flow can be found for the jet-forming conditions. In actual applications, to assure a safe dispensing process, the real Weber-numbers chosen should be between 20 and 50.

For a calculated estimation of the fluid flow velocity in the nozzle, for fluids with Newtonian flow behavior, the formula for capillary fluid flow according to the Hagen–Poiseuille law has been proven.

: Volumetric flow rate
: Pressure difference between nozzle entrance and nozzle exit
: Nozzle radius
: Dynamic viscosity
: Length of the nozzle

To avoid atomizing of the fluid at the nozzle exit, the fluid flow in the nozzle must be laminar, which is the case as long as the Reynolds number (Re) of the nozzle is smaller than the critical Reynolds-number of the nozzle:

Reynolds-number of the nozzle:

: Dynamic viscosity

Critical Reynolds-number of the nozzle:

Thus, the theoretical range of the jet-forming dispension is enclosed at its lower limit by the Weber-number and at its upper limit by the critical Reynolds-number. For practical applications, a high kinetic energy in the fluid jet is not desirable, because the jet probably would burst and spatter tiny droplets around the target point. Jet-forming dispensing systems are therefore usually operated in the area of lower Weber-numbers.

In practice, the calculation of the Weber-number becomes more complicated when fluids with additives are used, which demonstrate a non-Newtonian (i.e. thixotropic) flow behavior and therefore the viscosity during the flow through the nozzle is different.

Dynamic drop dispensing


Dynamic drop dispensing is characterised by separation of a drop from the nozzle exit through a dynamic process, because the static pressure of the liquid medium is insufficient for forming a fluid jet.

A well-known example is inkjet printing. In this application, the volume of a small dispensing chamber with adjoining nozzle becomes reduced through a short impulse, whereby the ink is ejected through the nozzle. Nozzle chamber, nozzle and ink reservoir are hereby fluidically connected without any valve in between. During the dispensing process, some of the medium is also flowing in the reverse direction (back into the reservoir). The surface tension of the fluid at the nozzle exit prevents air being sucked in and fluid from exiting the nozzle when the dispensing chamber is filled up again. The principle of this process is only useful for low-viscosity fluids and this principle is not applicable with higher fluid pressures.

Ink-jet systems have the following inherent properties:

• Very small single-drop volumes are achievable (8 picolitres)
• High dispensing frequencies can be realised (some kHz)
• Low costs for mass production
• Only certain low-viscosity media are dispensable (i.e. no volatile media)
• Principally not leak-proof

For industrial production, the dispensing amounts and the range of viscosity spectra of ink-jet systems for most applications are too small. In these fields of production, specially-designed valves with tappet drives of high dynamic pressure are used instead. These microdispensing systems are characterised by the following properties:

• Single drop volumes from 10 to 200 nanolitres
• Dispensing frequencies up to 100 Hz
• Dispensing accuracy < 1%
• Media viscosities up to 200 Pa·s (thixotropic)

Related Research Articles

Fluid dynamics Aspects of fluid mechanics involving flow

In physics and engineering, fluid dynamics is a subdiscipline of fluid mechanics that describes the flow of fluids—liquids and gases. It has several subdisciplines, including aerodynamics and hydrodynamics. Fluid dynamics has a wide range of applications, including calculating forces and moments on aircraft, determining the mass flow rate of petroleum through pipelines, predicting weather patterns, understanding nebulae in interstellar space and modelling fission weapon detonation.

Turbine rotary mechanical device that extracts energy from a fluid flow

A turbine is a rotary mechanical device that extracts energy from a fluid flow and converts it into useful work. The work produced by a turbine can be used for generating electrical power when combined with a generator. A turbine is a turbomachine with at least one moving part called a rotor assembly, which is a shaft or drum with blades attached. Moving fluid acts on the blades so that they move and impart rotational energy to the rotor. Early turbine examples are windmills and waterwheels.

A viscometer is an instrument used to measure the viscosity of a fluid. For liquids with viscosities which vary with flow conditions, an instrument called a rheometer is used. Thus, a rheometer can be considered as a special type of viscometer. Viscometers only measure under one flow condition.

In fluid dynamics, turbulence or turbulent flow is fluid motion characterized by chaotic changes in pressure and flow velocity. It is in contrast to a laminar flow, which occurs when a fluid flows in parallel layers, with no disruption between those layers.

Drag coefficient Dimensionless parameter to quantify fluid resistance

In fluid dynamics, the drag coefficient is a dimensionless quantity that is used to quantify the drag or resistance of an object in a fluid environment, such as air or water. It is used in the drag equation in which a lower drag coefficient indicates the object will have less aerodynamic or hydrodynamic drag. The drag coefficient is always associated with a particular surface area.

Coandă effect Tendency of a fluid jet to stay attached to a convex surface

The Coandă effect is the tendency of a fluid jet to stay attached to a convex surface. It is named after Romanian inventor Henri Coandă, who described it as "the tendency of a jet of fluid emerging from an orifice to follow an adjacent flat or curved surface and to entrain fluid from the surroundings so that a region of lower pressure develops."

Tribology is the science and engineering of interacting surfaces in relative motion. It includes the study and application of the principles of friction, lubrication, and wear. Tribology is highly interdisciplinary. It draws on many academic fields, including physics, chemistry, materials science, mathematics, biology, and engineering. People who work in the field of tribology are referred to as tribologists.

Permeability in fluid mechanics and the Earth sciences is a measure of the ability of a porous material to allow fluids to pass through it.

Darcy's law is an equation that describes the flow of a fluid through a porous medium. The law was formulated by Henry Darcy based on results of experiments on the flow of water through beds of sand, forming the basis of hydrogeology, a branch of earth sciences.

There are two different Bejan numbers (Be) used in the scientific domains of thermodynamics and fluid mechanics. Bejan numbers are named after Adrian Bejan.

Rheometer

A rheometer is a laboratory device used to measure the way in which a liquid, suspension or slurry flows in response to applied forces. It is used for those fluids which cannot be defined by a single value of viscosity and therefore require more parameters to be set and measured than is the case for a viscometer. It measures the rheology of the fluid.

Choked flow is a compressible flow effect. The parameter that becomes "choked" or "limited" is the fluid velocity.

Rocket engine nozzle

A rocket engine nozzle is a propelling nozzle used in a rocket engine to expand and accelerate the combustion gases produced by burning propellants so that the exhaust gases exit the nozzle at hypersonic velocities.

A spray nozzle is a precision device that facilitates dispersion of liquid into a spray. Nozzles are used for three purposes: to distribute a liquid over an area, to increase liquid surface area, and create impact force on a solid surface. A wide variety of spray nozzle applications use a number of spray characteristics to describe the spray.

Liquid One of the four fundamental states of matter

A liquid is a nearly incompressible fluid that conforms to the shape of its container but retains a (nearly) constant volume independent of pressure. As such, it is one of the four fundamental states of matter, and is the only state with a definite volume but no fixed shape. A liquid is made up of tiny vibrating particles of matter, such as atoms, held together by intermolecular bonds. Like a gas, a liquid is able to flow and take the shape of a container. Most liquids resist compression, although others can be compressed. Unlike a gas, a liquid does not disperse to fill every space of a container, and maintains a fairly constant density. A distinctive property of the liquid state is surface tension, leading to wetting phenomena. Water is, by far, the most common liquid on Earth.

Reynolds number Dimensionless quantity used to help predict fluid flow patterns

The Reynolds number is an important dimensionless quantity in fluid mechanics used to help predict flow patterns in different fluid flow situations. At low Reynolds numbers, flows tend to be dominated by laminar (sheet-like) flow, while at high Reynolds numbers turbulence results from differences in the fluid's speed and direction, which may sometimes intersect or even move counter to the overall direction of the flow. These eddy currents begin to churn the flow, using up energy in the process, which for liquids increases the chances of cavitation. The Reynolds number has wide applications, ranging from liquid flow in a pipe to the passage of air over an aircraft wing. It is used to predict the transition from laminar to turbulent flow, and is used in the scaling of similar but different-sized flow situations, such as between an aircraft model in a wind tunnel and the full size version. The predictions of the onset of turbulence and the ability to calculate scaling effects can be used to help predict fluid behaviour on a larger scale, such as in local or global air or water movement and thereby the associated meteorological and climatological effects.

Spray nozzles are designed to perform under various operating conditions. The following characteristics should be considered when selecting a nozzle:

Visco-elastic jets

Visco-elastic jets are the jets of viscoelastic fluids, i.e. fluids that disobey Newton's law of Viscocity. A Viscoelastic fluid that returns to its original shape after the applied stress is released.

Biofluid dynamics may be considered as the discipline of biological engineering or biomedical engineering in which the fundamental principles of fluid dynamics are used to explain the mechanisms of biological flows and their interrelationships with physiological processes, in health and in diseases/disorder. It can be considered as the conjuncture of mechanical engineering and biological engineering. It spans from cells to organs, covering diverse aspects of the functionality of systemic physiology, including cardiovascular, respiratory, reproductive, urinary, musculoskeletal and neurological systems etc. Biofluid dynamics and its simulations in computational fluid dynamics (CFD) apply to both internal as well as external flows. Internal flows such as cardiovascular blood flow and respiratory airflow, and external flows such as flying and aquatic locomotion. Biological fluid Dynamics involves the study of the motion of biological fluids. It can be either circulatory system or respiratory systems. Understanding the circulatory system is one of the major areas of research. The respiratory system is very closely linked to the circulatory system and is very complex to study and understand. The study of Biofluid Dynamics is also directed towards finding solutions to some of the human body related diseases and disorders. The usefulness of the subject can also be understood by seeing the use of Biofluid Dynamics in the areas of physiology in order to explain how living things work and about their motions, in developing an understanding of the origins and development of various diseases related to human body and diagnosing them, in finding the cure for the diseases related to cardiovascular and pulmonary systems.

Capillary Breakup Rheometry is an experimental technique used to assess the extensional rheological response of low viscous fluids. Unlike most shear and extensional rheometers, this technique does not involve active stretch or measurement of stress or strain but exploits only surface tension to create a uniaxial extensional flow. Hence, although it is common practice to use the name rheometer, capillary breakup techniques should be better addressed to as indexers.

References