A positive pressure enclosure, also known as a welding habitat or hot work habitat, is a chamber used to provide a safe working environment for performing hot work in the presence of explosive gases or vapors. They are commonly used in welding environments and are associated with the offshore oil industry. [1]

Contents

A positive pressure enclosure works by providing a constant inflow of breathable air, which in turn causes a continuous outflow of gas from the chamber. This outflow of gas prevents the ingress of explosive gases or vapors that are often present in these work environments. This constant venting of gases from the chamber also serves to purge the air inside the chamber of unwanted gaseous byproducts of the welding process. Most commercial versions of positive pressure enclosures are referred to by their manufacturers as habitats. [2]


Safety measures

Air quality

According to Malaysia's Department of Occupational Safety and Health (DOSH) the ventilation is considered adequate when the number of air changes every hour is not less than 10 under normal conditions (defined as "processes which generate little or no heat, smoke or fume") and no less than twenty ("should there be processes which generate heat, smoke or fume"). [3]

The airflow inside the habitat should be arranged in a one-way flow with the inlet (at floor level) and outlet (at top level) on the farthest and opposite side. The habitat ventilation flow rate must be 2,000 cubic feet per minute from a clean source per welder to dilute the polluted air inside the habitat.[ citation needed ]

Heat stress

The United States Department of Labor OSHA claims that every type of job that raises workers deep core temperature (listed as higher than 100.4 degrees F (38°C)) raises the risk of heat stress, and provides a list of guidelines which might be used to manage work in these environments. [4]

Positive pressure assurance

A minimum positive pressure of 0.1 inch of water or 0.00025 bar (equivalent to 25 Pascal or 0.00363 PSI) shall be maintained inside the Habitat enclosure to prevent ingestion of hydrocarbon in the event of leak occurred outside. [5] [ unreliable source? ]

Standards

IEC standard

Many countries are members of the International Electrotechnical Commission (IEC). Positive pressure enclosures, or "welding habitats" are working on the principle of overpressure. This protection principle is regulated by IEC Standard 60079-13. [6]

ATEX directive

The ATEX certification is the national certification standard of the European Union, and mandatory to operate equipment in explosive atmosphere in Europe. ATEX certification is not based on the IECEx certification scheme, certification is bases on the ATEX directive 2014/34/EU – see main article. Under the ATEX 2014/34/EU Directive, all equipment requires a proper manufacturer's EU Declaration of Conformity. For Zone 1 welding habitats this EU Declaration of Conformity must be based on a Notified Body issued EU–Type Examination Certificate for pressurized habitats (rooms) EN 60079-13.

Operating principles

Flammability limits

Flammable gases are not generally explosive under all conditions,[ citation needed ] . Additionally, oxygen must be present. [7] The flammability limits of gases are expressed in proportions to the other gases present.[ citation needed ] For example, for methane, research by Akifumi Takahashi et. al. shows limits between 4.4% for the lower explosive limit and the upper explosive limit at 16.3%. [8] A positive pressure enclosure works by ensuring that the methane present in the work area never approaches the lower explosive limit.

Positive pressure

The operating pressure inside a typical isolation chamber is set only marginally above local pressure; typically only 0.05 kilopascals (about 0.007 pounds per square inch) above local atmospheric pressure. This is low enough to be undetectable to operators working inside the enclosure (a person sitting in a bathtub full of water is exposed to higher pressures), but due to the leakages, it needs to ensure that the volume of air inside the enclosure is constantly changing. Intake air is drawn into the enclosure by fan units.[ citation needed ]

See also

Related Research Articles

<span class="mw-page-title-main">Acetylene</span> Hydrocarbon compound (HC≡CH)

Acetylene is the chemical compound with the formula C2H2 and structure H−C≡C−H. It is a hydrocarbon and the simplest alkyne. This colorless gas is widely used as a fuel and a chemical building block. It is unstable in its pure form and thus is usually handled as a solution. Pure acetylene is odorless, but commercial grades usually have a marked odor due to impurities such as divinyl sulfide and phosphine.

<span class="mw-page-title-main">Fume hood</span> Type of local ventilation device

A fume hood is a type of local exhaust ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapors or dusts. The device is an enclosure with a movable sash window on one side that traps and exhausts gases and particulates either out of the area or back into the room, and is most frequently used in laboratory settings.

<span class="mw-page-title-main">Saturation diving</span> Diving decompression technique

Saturation diving is diving for periods long enough to bring all tissues into equilibrium with the partial pressures of the inert components of the breathing gas used. It is a diving mode that reduces the number of decompressions divers working at great depths must undergo by only decompressing divers once at the end of the diving operation, which may last days to weeks, having them remain under pressure for the whole period. A diver breathing pressurized gas accumulates dissolved inert gas used in the breathing mixture to dilute the oxygen to a non-toxic level in the tissues, which can cause decompression sickness if permitted to come out of solution within the body tissues; hence, returning to the surface safely requires lengthy decompression so that the inert gases can be eliminated via the lungs. Once the dissolved gases in a diver's tissues reach the saturation point, however, decompression time does not increase with further exposure, as no more inert gas is accumulated.

<span class="mw-page-title-main">Positive pressure</span> Force applied in a chamber to remove a fluid

Positive pressure is a pressure within a system that is greater than the environment that surrounds that system. Consequently, if there is any leak from the positively pressured system, it will egress into the surrounding environment. This is in contrast to a negative pressure room, where air is sucked in.

<span class="mw-page-title-main">Confined space</span> Space with limited entry and egress and not suitable for human inhabitants

A confined space is a space with limited entry and egress and not suitable for human inhabitants. An example is the interior of a storage tank, occasionally entered by maintenance workers but not intended for human occupancy. Hazards in a confined space often include harmful dust or gases, asphyxiation, submersion in liquids or free-flowing granular solids, electrocution, or entrapment.

<span class="mw-page-title-main">Immediately dangerous to life or health</span> Exposure to dangerous levels of airborne contaminants

The term immediately dangerous to life or health (IDLH) is defined by the US National Institute for Occupational Safety and Health (NIOSH) as exposure to airborne contaminants that is "likely to cause death or immediate or delayed permanent adverse health effects or prevent escape from such an environment." Examples include smoke or other poisonous gases at sufficiently high concentrations. It is calculated using the LD50 or LC50. The Occupational Safety and Health Administration (OSHA) regulation defines the term as "an atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual's ability to escape from a dangerous atmosphere."

<span class="mw-page-title-main">Gas tungsten arc welding</span> Welding process

Gas tungsten arc welding is an arc welding process that uses a non-consumable tungsten electrode to produce the weld. The weld area and electrode are protected from oxidation or other atmospheric contamination by an inert shielding gas. A filler metal is normally used, though some welds, known as 'autogenous welds', or 'fusion welds' do not require it. A constant-current welding power supply produces electrical energy, which is conducted across the arc through a column of highly ionized gas and metal vapors known as a plasma.

<span class="mw-page-title-main">Electrical equipment in hazardous areas</span> Electrical equipment in places where fire or explosion hazards may exist

In electrical and safety engineering, hazardous locations are places where fire or explosion hazards may exist. Sources of such hazards include gases, vapors, dust, fibers, and flyings, which are combustible or flammable. Electrical equipment installed in such locations can provide an ignition source, due to electrical arcing, or high temperatures. Standards and regulations exist to identify such locations, classify the hazards, and design equipment for safe use in such locations.

A leak is a way for fluid to escape a container or fluid-containing system, such as a tank or a ship's hull, through which the contents of the container can escape or outside matter can enter the container. Leaks are usually unintended and therefore undesired. The word leak usually refers to a gradual loss; a sudden loss is usually called a spill.

Mixtures of dispersed combustible materials and oxygen in the air will burn only if the fuel concentration lies within well-defined lower and upper bounds determined experimentally, referred to as flammability limits or explosive limits. Combustion can range in violence from deflagration through detonation.

<span class="mw-page-title-main">ATEX directive</span> EU ATEX Directive on workplaces with an explosive atmosphere

The ATEX directives are two EU directives describing the minimum safety requirements for workplaces and equipment used in explosive atmospheres. The name is an initialization of the term ATmosphères EXplosibles.

<span class="mw-page-title-main">Intrinsic safety</span> Electrical safety protection technique

Intrinsic safety (IS) is a protection technique for safe operation of electrical equipment in hazardous areas by limiting the energy, electrical and thermal, available for ignition. In signal and control circuits that can operate with low currents and voltages, the intrinsic safety approach simplifies circuits and reduces installation cost over other protection methods. Areas with dangerous concentrations of flammable gases or dust are found in applications such as petrochemical refineries and mines. As a discipline, it is an application of inherent safety in instrumentation. High-power circuits such as electric motors or lighting cannot use intrinsic safety methods for protection.

<span class="mw-page-title-main">Thermal spraying</span> Coating process for applying heated materials to a surface

Thermal spraying techniques are coating processes in which melted materials are sprayed onto a surface. The "feedstock" is heated by electrical or chemical means.

<span class="mw-page-title-main">Valve actuator</span> Mechanism for opening and closing a valve

A valve actuator is the mechanism for opening and closing a valve. Manually operated valves require someone in attendance to adjust them using a direct or geared mechanism attached to the valve stem. Power-operated actuators, using gas pressure, hydraulic pressure or electricity, allow a valve to be adjusted remotely, or allow rapid operation of large valves. Power-operated valve actuators may be the final elements of an automatic control loop which automatically regulates some flow, level or other process. Actuators may be only to open and close the valve, or may allow intermediate positioning; some valve actuators include switches or other ways to remotely indicate the position of the valve.

<span class="mw-page-title-main">Dust explosion</span> Rapid combustion of fine particles suspended in the air

A dust explosion is the rapid combustion of fine particles suspended in the air within an enclosed location. Dust explosions can occur where any dispersed powdered combustible material is present in high-enough concentrations in the atmosphere or other oxidizing gaseous medium, such as pure oxygen. In cases when fuel plays the role of a combustible material, the explosion is known as a fuel-air explosion.

<span class="mw-page-title-main">Hyperbaric welding</span> Welding metal at elevated pressure

Hyperbaric welding is the process of extreme welding at elevated pressures, normally underwater. Hyperbaric welding can either take place wet in the water itself or dry inside a specially constructed positive pressure enclosure and hence a dry environment. It is predominantly referred to as "hyperbaric welding" when used in a dry environment, and "underwater welding" when in a wet environment. The applications of hyperbaric welding are diverse—it is often used to repair ships, offshore oil platforms, and pipelines. Steel is the most common material welded.

<span class="mw-page-title-main">Oxy-fuel welding and cutting</span> Metalworking technique using a fuel and oxygen

Oxy-fuel welding and oxy-fuel cutting are processes that use fuel gases and oxygen to weld or cut metals. French engineers Edmond Fouché and Charles Picard became the first to develop oxygen-acetylene welding in 1903. Pure oxygen, instead of air, is used to increase the flame temperature to allow localized melting of the workpiece material in a room environment. A common propane/air flame burns at about 2,250 K, a propane/oxygen flame burns at about 2,526 K, an oxyhydrogen flame burns at 3,073 K and an acetylene/oxygen flame burns at about 3,773 K.

<span class="mw-page-title-main">Flame arrester</span>

A flame arrester, deflagration arrester, or flame trap is a device or form of construction that will allow free passage of a gas or gaseous mixture but will interrupt or prevent the passage of flame. It prevents the transmission of flame through a flammable gas/air mixture by quenching the flame on the high surface area provided by an array of small passages through which the flame must pass. The emerging gases are cooled enough to prevent ignition on the protected side.

Infrared open-path gas detectors send out a beam of infrared light, detecting gas anywhere along the path of the beam. This linear 'sensor' is typically a few metres up to a few hundred metres in length. Open-path detectors can be contrasted with infrared point sensors.

Engineering controls are strategies designed to protect workers from hazardous conditions by placing a barrier between the worker and the hazard or by removing a hazardous substance through air ventilation. Engineering controls involve a physical change to the workplace itself, rather than relying on workers' behavior or requiring workers to wear protective clothing.

References

  1. Łabanowski, Jerzy (2011). "Development of under-water welding techniques". Welding International. 25 (12): 933–937. doi:10.1080/09507116.2010.540847. ISSN   0950-7116. S2CID   137610663.
  2. Halvorsen, Hugo (1 August 2015). "Working Together for Safety Recommendation 036E/2015 - Use of habitats" (PDF). samarbeidforsikkerhet.no. Archived (PDF) from the original on 4 December 2022. Retrieved 6 August 2023.
  3. "FACTORIES AND MACHINERY (SAFETY, HEALTH AND WELFARE) REGULATIONS 1970 (REVISED – 1983)". 28 February 1983. p. 12. Archived from the original on 16 August 2022. Retrieved 6 August 2023.
  4. "Heat Stress Guide". osha.gov. Retrieved 6 August 2023.
  5. admin (23 June 2022). "Pressurised Habitat Technician". Elite Offshore Pvt Ltd. Retrieved 6 August 2023.
  6. "International Standard IEC 60079-13" (PDF). iec.ch. May 2017. Retrieved 6 August 2023.
  7. Jones, G. W.; Kennedy, R. E. (1935). "Prevention of Gas Explosions by Controlling Oxygen Concentration". Industrial & Engineering Chemistry. 27 (11): 1344–1346. doi:10.1021/ie50311a027. ISSN   0019-7866.
  8. Takahashi, Akifumi; Urano, Youkichi; Tokuhashi, Kazuaki; Hidekazu Nagai; Kaise, Masahiro; Kondo, Shigeo (1 September 1998). "Fusing ignition of various metal wires for explosion limits measurement of methane/air mixture". Journal of Loss Prevention in the Process Industries. 11 (5): 353–360. doi:10.1016/S0950-4230(98)00010-2. ISSN   0950-4230.