A well test is conducted to evaluate the amount of water that can be pumped from a particular water well. More specifically, a well test will allow prediction of the maximum rate at which water can be pumped from a well, and the distance that the water level in the well will fall for a given pumping rate and duration of pumping.
Well testing differs from aquifer testing in that the behaviour of the well is primarily of concern in the former, while the characteristics of the aquifer (the geological formation or unit that supplies water to the well) are quantified in the latter.
An aquifer test is conducted to evaluate an aquifer by "stimulating" the aquifer through constant pumping, and observing the aquifer's "response" (drawdown) in observation wells. Aquifer testing is a common tool that hydrogeologists use to characterize a system of aquifers, aquitards and flow system boundaries.
When water is pumped from a well the water level in the well falls. This fall is called drawdown. The amount of water that can be pumped is limited by the drawdown produced. Typically, drawdown also increases with the length of time that the pumping continues.
In water-related science and engineering, there are two similar but distinct definitions in use for the word drawdown:
The components of observed drawdown in a pumping well were first described by Jacob (1947), and the test was refined independently by Hantush (1964) and Bierschenk (1963) as consisting of two related components,
Mahdi S. Hantush (1921–1984) was a prominent Hydrologist known for his analytical work on leaky aquifers and well hydraulics. He is the founder of the New Mexico Tech Hydrology Program. His granddaughter is Yasmin Younis, the 2018 Student Commencement Speaker at Boston University’s 185th Commencement which went viral all over the Middle East.
where s is drawdown (units of length e.g., m), is the pumping rate (units of volume flowrate e.g., m³/day), is the aquifer loss coefficient (which increases with time — as predicted by the Theis solution) and is the well loss coefficient (which is constant for a given flow rate).
The first term of the equation () describes the linear component of the drawdown; i.e., the part in which doubling the pumping rate doubles the drawdown.
The second term () describes what is often called the 'well losses'; the non-linear component of the drawdown. To quantify this it is necessary to pump the well at several different flow rates (commonly called steps). Rorabaugh (1953) added to this analysis by making the exponent an arbitrary power (usually between 1.5 and 3.5).
To analyze this equation, both sides are divided by the discharge rate (), leaving on the left side, which is commonly referred to as specific drawdown. The right hand side of the equation becomes that of a straight line. Plotting the specific drawdown after a set amount of time () since the beginning of each step of the test (since drawdown will continue to increase with time) versus pumping rate should produce a straight line.
Fitting a straight line through the observed data, the slope of the best fit line will be (well losses) and the intercept of this line with will be (aquifer losses). This process is fitting an idealized model to real world data, and seeing what parameters in the model make it fit reality best. The assumption is then made that these fitted parameters best represent reality (given the assumptions that went into the model are true).
The relationship above is for fully penetrating wells in confined aquifers (the same assumptions used in the Theis solution for determining aquifer characteristics in an aquifer test).
Often the well efficiency is determined from this sort of test, this is a percentage indicating the fraction of total observed drawdown in a pumping well which is due to aquifer losses (as opposed to being due to flow through the well screen and inside the borehole). A perfectly efficient well, with perfect well screen and where the water flows inside the well in a frictionless manner would have 100% efficiency. Unfortunately well efficiency is hard to compare between wells because it depends on the characteristics of the aquifer too (the same amount of well losses compared to a more transmissive aquifer would give a lower efficiency).
Specific capacity is a quantity that which a water well can produce per unit of drawdown. It is normally obtained from a step drawdown test. Specific capacity is expressed as:
where
The specific capacity of a well is also a function of the pumping rate it is determined at. Due to non-linear well losses the specific capacity will decrease with higher pumping rates. This complication makes the absolute value of specific capacity of little use; though it is useful for comparing the efficiency of the same well through time (e.g., to see if the well requires rehabilitation).
Hydrology is the scientific study of the movement, distribution, and quality of water on Earth and other planets, including the water cycle, water resources and environmental watershed sustainability. A practitioner of hydrology is a hydrologist, working within the fields of earth or environmental science, physical geography, geology or civil and environmental engineering. Using various analytical methods and scientific techniques, they collect and analyze data to help solve water related problems such as environmental preservation, natural disasters, and water management.
The water table is the upper surface of the zone of saturation. The zone of saturation is where the pores and fractures of the ground are saturated with water.
Hydrogeology is the area of geology that deals with the distribution and movement of groundwater in the soil and rocks of the Earth's crust. The terms groundwater hydrology, geohydrology, and hydrogeology are often used interchangeably.
Permeability in fluid mechanics and the earth sciences is a measure of the ability of a porous material to allow fluids to pass through it.
Darcy's law is an equation that describes the flow of a fluid through a porous medium. The law was formulated by Henry Darcy based on results of experiments on the flow of water through beds of sand, forming the basis of hydrogeology, a branch of earth sciences.
A hydrograph is a graph showing the rate of flow (discharge) versus time past a specific point in a river, channel, or conduit carrying flow. The rate of flow is typically expressed in cubic meters or cubic feet per second . It can also refer to a graph showing the volume of water reaching a particular outfall, or location in a sewerage network. Graphs are commonly used in the design of sewerage, more specifically, the design of surface water sewerage systems and combined sewers.
Hydraulic conductivity, symbolically represented as , is a property of vascular plants, soils and rocks, that describes the ease with which a fluid can move through pore spaces or fractures. It depends on the intrinsic permeability of the material, the degree of saturation, and on the density and viscosity of the fluid. Saturated hydraulic conductivity, Ksat, describes water movement through saturated media. By definition, hydraulic conductivity is the ratio of velocity to hydraulic gradient indicating permeability of porous media.
Hydraulic head or piezometric head is a specific measurement of liquid pressure above a vertical datum.
In the field of hydrogeology, storage properties are physical properties that characterize the capacity of an aquifer to release groundwater. These properties are Storativity (S), specific storage (Ss) and specific yield (Sy).
Used in hydrogeology, the groundwater flow equation is the mathematical relationship which is used to describe the flow of groundwater through an aquifer. The transient flow of groundwater is described by a form of the diffusion equation, similar to that used in heat transfer to describe the flow of heat in a solid. The steady-state flow of groundwater is described by a form of the Laplace equation, which is a form of potential flow and has analogs in numerous fields.
A slug test is a particular type of aquifer test where water is quickly added or removed from a groundwater well, and the change in hydraulic head is monitored through time, to determine the near-well aquifer characteristics. It is a method used by hydrogeologists and civil engineers to determine the transmissivity/hydraulic conductivity and storativity of the material the well is completed in.
Centrifugal pumps are a sub-class of dynamic axisymmetric work-absorbing turbomachinery. Centrifugal pumps are used to transport fluids by the conversion of rotational kinetic energy to the hydrodynamic energy of the fluid flow. The rotational energy typically comes from an engine or electric motor. The fluid enters the pump impeller along or near to the rotating axis and is accelerated by the impeller, flowing radially outward into a diffuser or volute chamber (casing), from which it exits.
Fluid conductance is a measure of how effectively fluids are transported through a medium or a region. The concept is particularly useful in cases in which the amount of fluid transported is linearly related to whatever is driving the transport.
The flow coefficient of a device is a relative measure of its efficiency at allowing fluid flow. It describes the relationship between the pressure drop across an orifice, valve or other assembly and the corresponding flow rate.
Well drainage means drainage of agricultural lands by wells. Agricultural land is drained by pumped wells to improve the soils by controlling water table levels and soil salinity.
A hydrologic model is a simplification of a real-world system that aids in understanding, predicting, and managing water resources. Both the flow and quality of water are commonly studied using hydrologic models.
Specific Pump Power (SPP) or Pumpkin Power (PP) is a metric in fluid dynamics that quantifies the energy-efficiency of pump systems. It is a measure of the electric power that is needed to operate a pump, relative to the volume flow rate. It is not constant for a given pump, but changes with both flow rate and pump pressure. This term 'SPP' is adapted from the established metric Specific fan power (SFP) for fans (blowers). It is commonly used when measuring the energy efficiency of buildings.
Additional references on pumping test analysis methods other than the one described above (typically referred to as the Hantush-Bierschenk method) can be found in the general references on aquifer tests and hydrogeology.