25-pair color code

Last updated
Single-core 25-pair, 50-conductor cable Cable-singlecore-25-pair-0a.jpg
Single-core 25-pair, 50-conductor cable

The 25-pair color code, originally known as even-count color code, [1] is a color code used to identify individual conductors in twisted-pair wiring for telecommunications.

Contents

Color coding

With the development of new generations of telecommunication cables with polyethylene-insulated conductors (PIC) by Bell Laboratories for the Bell System in the 1950s, new methods were developed to mark each individual conductor in cables. [2] Each wire is identified by the combination of two colors, one of which is the major color, and the second the minor color. Major and minor colors are chosen from two different groups of five, resulting in 25 color combinations. The color combinations are applied to the insulation that covers each conductor. Typically, one color is a prominent background color of the insulation, and the other is a tracer, consisting of stripes, rings, or dots, applied over the background. The background color always matches the tracer color of its paired conductor, and vice versa.

The major, or primary group of colors consists of the sequence of white, red, black, yellow, and violet (mnemonic: Why run backwards? You'll vomit!). [3] The minor, or secondary color is chosen from the sequence blue, orange, green, brown, and slate (mnemonic: Bell operators give better service. [4] ). [5] [6] [7]

25-pair color coding using twisted pairs with solid color coding only, without tracers. This method was rarely used. 25 pair color code chart.svg
25-pair color coding using twisted pairs with solid color coding only, without tracers. This method was rarely used.
25-pair color code
Pair
no.
Major colorMinor color
1WhiteBlue
2Orange
3Green
4Brown
5Slate
6RedBlue
7Orange
8Green
9Brown
10Slate
11BlackBlue
12Orange
13Green
14Brown
15Slate
16YellowBlue
17Orange
18Green
19Brown
20Slate
21VioletBlue
22Orange
23Green
24Brown
25Slate

The wire pairs are referenced directly by their color combination, or by the pair number. For example, pair 9 is also called the red-brown pair. In technical tabulations, the colors are often suitably abbreviated.

Violet is the standard name in the telecommunications and electronics industry, but it is sometimes referred to as purple. Similarly, slate is a particular shade of gray. The names of most of the colors were taken from the conventional colors of the rainbow or optical spectrum, and in the electronic color code, which uses the same ten colors, albeit in a different order.[ citation needed ]

When used for plain old telephone service (POTS), the first wire is known as the tip or A-leg (U.K.) conductor, and is usually connected to the positive side of a direct current (DC) circuit, while the second wire is known as the ring lead or B-leg (U.K.), and is connected to the negative side of the circuit. Neither of these two sides of the line has a connection to the local ground. This creates a balanced audio circuit with common-mode rejection, also known as a differential pair. The tip and ring convention is based on the 14 inch (6.35 mm) TRS phone connectors, which were employed in telephone switchboards in the 19th and 20th centuries, where the tip contact of the connector is separated from the ring contact by a spacer of insulation. The connection furthest from the cable is known as the tip, the middle connection is the ring, and the (largest) connection closest to the wire is the sleeve.

Older Bell System wiring inside customer premises used 4-conductor untwisted wire cable. The 4 conductors were solid red, green, yellow & black wires. They match to the current 25-color code as follows:

Wire green.svg green ("Line 1" tip) Wire white blue stripe.svg white/blue
Wire red.svg red ("Line 1" ring) Wire blue white stripe.svg blue/white
Wire black.svg black ("Line 2" tip) Wire white orange stripe.svg white/orange
Wire yellow.svg yellow ("Line 2" ring) Wire orange white stripe.svg orange/white

25-pair telco cable pinout

A common application of the 25-pair color code is the cabling for the Registered Jack interface RJ21, which uses a female 50-pin miniature ribbon connector, as shown in the following table. The geometry of the pins of the receptacle (right hand image) corresponds to the pin numbers of the table. The left column of pins are the ring (R) conductors, while all tip (T) conductors are on the right.

Color
(minor/major)
(R)(T)Color
(major/minor)
The corresponding
pin order in the
female RJ21 connector
Pin no.
Wire blue white stripe.svg blue/white126 Wire white blue stripe.svg white/blue RJ21-female-connector.jpg
Wire orange white stripe.svg orange/white227 Wire white orange stripe.svg white/orange
Wire green white stripe.svg green/white328 Wire white green stripe.svg white/green
Wire brown white stripe.svg brown/white429 Wire white brown stripe.svg white/brown
Wire gray white stripe.svg slate/white530 Wire white gray stripe.svg white/slate
Wire blue red stripe.svg blue/red631 Wire red blue stripe.svg red/blue
Wire orange red stripe.svg orange/red732 Wire red orange stripe.svg red/orange
Wire green red stripe.svg green/red833 Wire red green stripe.svg red/green
Wire brown red stripe.svg brown/red934 Wire red brown stripe.svg red/brown
Wire gray red stripe.svg slate/red1035 Wire red gray stripe.svg red/slate
Wire blue black stripe.svg blue/black1136 Wire black blue stripe.svg black/blue
Wire orange black stripe.svg orange/black1237 Wire black orange stripe.svg black/orange
Wire green black stripe.svg green/black1338 Wire black green stripe.svg black/green
Wire brown black stripe.svg brown/black1439 Wire black brown stripe.svg black/brown
Wire gray black stripe.svg slate/black1540 Wire black gray stripe.svg black/slate
Wire blue yellow stripe.svg blue/yellow1641 Wire yellow blue stripe.svg yellow/blue
Wire orange yellow stripe.svg orange/yellow1742 Wire yellow orange stripe.svg yellow/orange
Wire green yellow stripe.svg green/yellow1843 Wire yellow green stripe.svg yellow/green
Wire brown yellow stripe.svg brown/yellow1944 Wire yellow brown stripe.svg yellow/brown
Wire gray yellow stripe.svg slate/yellow2045 Wire yellow gray stripe.svg yellow/slate
Wire blue violet stripe.svg blue/violet2146 Wire violet blue stripe.svg violet/blue
Wire orange violet stripe.svg orange/violet2247 Wire violet orange stripe.svg violet/orange
Wire green violet stripe.svg green/violet2348 Wire violet green stripe.svg violet/green
Wire brown violet stripe.svg brown/violet2449 Wire violet brown stripe.svg violet/brown
Wire gray violet stripe.svg slate/violet2550 Wire violet gray stripe.svg violet/slate

Larger cables

For cables with more than 25 pairs, each group of 25 is called a binder group. The binder groups are marked with mylar ribbons using the same color coding system, starting with a white/blue ribbon, then a white/orange ribbon, and so on. The 24th binder group has a violet/brown ribbon, completing a super binder of 600 pairs. [5] [6]

In cables of more than 600 pairs, each of the 600-pair super binder group bundles is wrapped with a mylar binder ribbon, or string, matching the "tip" colors of the color code, starting with white. The pattern then starts over with the first 25-pair group as white/blue, and continues indefinitely, in multiples of 600 pairs or parts thereof. For example, a 900-pair cable has the first 600 pairs in 24 groups of 25 pairs in a white binder, and the remaining 300 pairs in 12 groups of 25 pairs wrapped in a red binder. [5] [6]

Some cables are "mirrored" or "clocked" with a pattern that is known throughout the telephone industry. Starting with the first binder group in the center, the technician counts the cable's groups in a spiral direction depending on the location of the central office or switch. If looking at the cable's core and the switch is in that direction, the groups are counted counter-clockwise. If the cable is the field side, the count is clockwise. There are indicators on the mylar ribbons to know where to begin for each layer and a diagram for the different cable sizes should be readily available for reference. [5] [6]

Other color schemes are sometimes used for outdoor cables, particularly outside the U.S., but this color code is common for aerial and underground cables up to several thousand pairs in North America. In the UK, the British Post Office (later BT) used this color code for what is now known loosely as CW1308 specification cables, referring to the Post Office's "Cable and Wire" specification No. 1308.

Extra pairs and colors

Colors of additional pairs in multi-pair cable as per Bell Standards Addl-Pairs.jpg
Colors of additional pairs in multi-pair cable as per Bell Standards

When working on aerial cable splicing and installation, it is common to use a telephone lineman's set or "butt set" to communicate over long distances. To facilitate this, extra pairs of wires are embedded in cables using "major" colors for both wires (instead of the major/minor color combinations used for the rest). One extra pair (red–white) may be embedded into cables that are 6 to 75 pairs; two pairs (red–white and black–white) may be encapsulated in cables of 100 to 300 pairs; and three pairs (red–white, black–white, and yellow–white) may be included in cables of 400 to 900 pairs. [6] These extra pairs are often referred to as "talk pairs", and are never used for subscriber service.

Optical cable

A color coding method used for fiber-optic cables, TIA-598-C, starts with the same first ten colors, adding the color rose for 11, and aqua for 12. [8]

See also

Related Research Articles

<span class="mw-page-title-main">Insulator (electricity)</span> Material that does not conduct an electric current

An electrical insulator is a material in which electric current does not flow freely. The atoms of the insulator have tightly bound electrons which cannot readily move. Other materials—semiconductors and conductors—conduct electric current more easily. The property that distinguishes an insulator is its resistivity; insulators have higher resistivity than semiconductors or conductors. The most common examples are non-metals.

<span class="mw-page-title-main">600 series connector</span>

A 600 series connector is an obsolete three-pin connector with up to six conductors.

<span class="mw-page-title-main">Electronic color code</span> Color code to indicate values of electronic components

An electronic color code or electronic colour code is used to indicate the values or ratings of electronic components, usually for resistors, but also for capacitors, inductors, diodes and others. A separate code, the 25-pair color code, is used to identify wires in some telecommunications cables. Different codes are used for wire leads on devices such as transformers or in building wiring.

<span class="mw-page-title-main">Twisted pair</span> Type of wiring used for communications

Twisted pair cabling is a type of communications cable in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted balanced pair, a twisted pair reduces electromagnetic radiation from the pair and crosstalk between neighbouring pairs and improves rejection of external electromagnetic interference. It was invented by Alexander Graham Bell.

<span class="mw-page-title-main">Electrical connector</span> Device used to join electrical conductors

Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor. An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit, or between different electrical circuits, thereby joining them into a larger circuit.

<span class="mw-page-title-main">Ribbon cable</span> Wide and flat cable with multiple conductors

A ribbon cable is a cable with many conducting wires running parallel to each other on the same flat plane. As a result, the cable is wide and flat. Its name comes from its resemblance to a piece of ribbon.

<span class="mw-page-title-main">Registered jack</span> Telecommunication network interface

A registered jack (RJ) is a standardized telecommunication network interface for connecting voice and data equipment to a computer service provided by a local exchange carrier or long distance carrier. Registered interfaces were first defined in the Universal Service Ordering Code (USOC) system of the Bell System in the United States for complying with the registration program for customer-supplied telephone equipment mandated by the Federal Communications Commission (FCC) in the 1970s. They were subsequently codified in title 47 of the Code of Federal Regulations Part 68. Registered jack connections began to see use after their invention in 1973 by Bell Labs. The specification includes physical construction, wiring, and signal semantics. Accordingly, registered jacks are primarily named by the letters RJ, followed by two digits that express the type. Additional letter suffixes indicate minor variations. For example, RJ11, RJ14, and RJ25 are the most commonly used interfaces for telephone connections for one-, two-, and three-line service, respectively. Although these standards are legal definitions in the United States, some interfaces are used worldwide.

Electrical wiring in North America follows the regulations and standards applicable at the installation location. It is also designed to provide proper function, and is also influenced by history and traditions of the location installation.

<span class="mw-page-title-main">Telephone jack and plug</span> Connectors for wiring of telephone equipment

A telephone jack and a telephone plug are electrical connectors for connecting a telephone set or other telecommunications apparatus to the telephone wiring inside a building, establishing a connection to a telephone network. The plug is inserted into its counterpart, the jack, which is commonly affixed to a wall or baseboard. The standards for telephone jacks and plugs vary from country to country, though the 6P2C style modular plug has become by far the most common type.

<span class="mw-page-title-main">Banana connector</span> Single-wire electrical connector used for joining wires to equipment

A banana connector is a single-wire electrical connector used for joining wires to equipment. The term 4 mm connector is also used, especially in Europe, although not all banana connectors will mate with 4 mm parts, and 2 mm banana connectors exist. Various styles of banana plug contacts exist, all based on the concept of spring metal applying outward force into the unsprung cylindrical jack to produce a snug fit with good electrical conductivity. Common types include: a solid pin split lengthwise and splayed slightly, a tip of four leaf springs, a cylinder with a single leaf spring on one side, a bundle of stiff wire, a central pin surrounded by a multiple-slit cylinder with a central bulge, or simple sheet spring metal rolled into a nearly complete cylinder. The plugs are frequently used to terminate patch cords for electronic test equipment such as laboratory power supply units, while sheathed banana plugs are common on multimeter probe leads.

<span class="mw-page-title-main">Telephone line</span> Single-user circuit on a telephone communication system

A telephone line or telephone circuit is a single-user circuit on a telephone communication system. It is designed to reproduce speech of a quality that is understandable. It is the physical wire or other signaling medium connecting the user's telephone apparatus to the telecommunications network, and usually also implies a single telephone number for billing purposes reserved for that user. Telephone lines are used to deliver landline telephone service and digital subscriber line (DSL) phone cable service to the premises. Telephone overhead lines are connected to the public switched telephone network. The voltage at a subscriber's network interface is typically 48 V between the ring and tip wires, with tip near ground and ring at –48 V.

<span class="mw-page-title-main">66 block</span> Table used to physically connect phone lines

A 66 block is a type of punch-down block used to connect sets of wires in a telephone system. They have been manufactured in four common configurations, A, B, E and M. A and B styles have the clip rows on 0.25" centers while E and M have the clip rows on 0.20" centers. The A blocks have 25 slotted holes on the left side for position the incoming building cable with a 50 slot fanning strip on the right side for distribution cables. They have been obsolete for many years. The B & M styles have 50 slot fanning strip on both sides. The B style is used mainly in distribution panels where several destinations need to connect to the same source. The M blocks are often used to connect a single instrument to such a distribution block. The E style has 5 columns of 10 2 clips rows and are used for transitioning from the 25 pair distribution cable to a 25 pair RJ21 style female ribbon connector.

<span class="mw-page-title-main">Micro ribbon connector</span> Type of electrical connector

The micro ribbon or miniature ribbonconnector is a common type of electrical connector for a variety of applications, such as in computer and telecommunications equipment having many contacts.

<span class="mw-page-title-main">IDC (electrical connector)</span> Type of electrical connector

An insulation-displacement contact (IDC), also known as insulation-piercing contact (IPC), is an electrical connector designed to be connected to the conductor(s) of an insulated cable by a connection process which forces a selectively sharpened blade or blades through the insulation, bypassing the need to strip the conductors of insulation before connecting. When properly made, the connector blade cold-welds to the conductor, making a theoretically reliable gas-tight connection.

<span class="mw-page-title-main">Computer port (hardware)</span> Computer hardware

A computer port is a hardware piece on a computer where an electrical connector can be plugged to link the device to external devices, such as another computer, a peripheral device or network equipment.

<span class="mw-page-title-main">Modular connector</span> Electrical connector commonly used in telephone and computer networks

A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.

<span class="mw-page-title-main">Tip and ring</span> Conductors of a telephone line

Tip and ring are the two conductors or sides of a telephone line. Their names are derived from the telephone plugs used for connecting telephone calls in manual switchboards. One side of the line is connected to the metal tip of the plug, and the second is connected to a metal ring behind the tip, separated and insulated from the tip by a non-conducting material. When inserted into a jack, the plug's tip conductor connects first, followed by the ring conductor. In many European countries, tip and ring are referred to as the A and B wires.

<span class="mw-page-title-main">British telephone socket</span> Type of telephone socket design

British telephone sockets were introduced in their current plug and socket form on 19 November 1981 by British Telecom to allow subscribers to connect their own telephones. The connectors are specified in British Standard BS 6312. Electrical characteristics of the telephone interface are specified by individual network operators, e.g. in British Telecom's SIN 351. Electrical characteristics required of British telephones used to be specified in BS 6305.

The 20-pair colour code is a colour code used in Australia to identify individual conductors in a kind of electrical telecommunication wiring for indoor use, known as twisted pair cables. The colours are applied to the insulation that covers each conductor. The first colour is chosen from one group of five colours.

ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).

References

  1. AT&T, Bell System Practices, Section 461-200-101 Issue 7, Connector Cables—Identification (May 1979)
  2. F.W. Horn, Even-Count Cable, Bell Laboratories Record 37(6), 208 (June 1959)
  3. Abruzzino, James: Communications Cabling (2E), page 187. CNC Press, 2000
  4. "Modern Telephone Cable Color Code". www.kadiak.org.
  5. 1 2 3 4 Highhouse, John (1997). A Guide for Telecommunications Cable Splicing. Cengage Learning. ISBN   9780827380660.
  6. 1 2 3 4 5 American Telephone And Telegraph Company (February 1959). "Even PIC Cables" (PDF). Bell System Practices – Outside Plant Construction and Maintenance, Section G50.607.3 Issue 2.
  7. A compilation of mnemonics for Electronics Engineering (ECE) by Jemery Gentiles lists both the standard mnemonic pair and a not-safe-for-work alternate.
  8. Leroy Davis (2007-02-21). "Fiber wire color coding". Archived from the original on 2007-12-12. Retrieved 2007-12-01.