Canadian Electrical Code

Last updated

The Canadian Electrical Code, CE Code, or CSA C22.1 is a standard published by the Canadian Standards Association pertaining to the installation and maintenance of electrical equipment in Canada.

Contents

The first edition of the Canadian Electrical Code was published in 1927. [1] The current (25th) edition was published in April of 2021. Code revisions are now scheduled on a three-year cycle. The Code is produced by a large body of volunteers from industry and various levels of government. The Code uses a prescriptive model, outlining in detail the wiring methods that are acceptable. In the current edition, the Code recognizes that other methods can be used to assure safe installations, but these methods must be acceptable to the authority enforcing the Code in a particular jurisdiction.

The Canadian Electrical Code serves as the basis for wiring regulations across Canada. Generally, legislation adopts the Code by reference, usually with a schedule of changes that amend the Code for local conditions. These amendments may be administrative in nature or may consist of technical content particular to the region. Since the Code is a copyrighted document produced by a private body, it may not be distributed without copyright permission from the Canadian Standards Association.

The Code is divided into sections, each section is labeled with an even number and a title. Sections 0, 2, 4, 6, 8, 10, 12, 14, 16, and 26 include rules that apply to installations in general; the remaining sections are supplementary and deal with installation methods in specific locations or situations. Some examples of general sections include: grounding and bonding, protection and control, conductors, and definitions. Some examples of supplementary sections include: wet locations, hazardous locations, patient care areas, emergency systems, and temporary installations. When interpreting the requirements for a particular installation, rules found in supplementary sections of the Code amend or supersede the rules in general sections of the Code.

The Canadian Electrical Code does not apply to vehicles, systems operated by an electrical or communications utility, railway systems, aircraft or ships; since these installations are already regulated by separate documents.

The Canadian Electrical Code is published in several parts: Part I is the safety standard for electrical installations. Part II is a collection of individual standards for the evaluation of electrical equipment or installations. (Part I requires that electrical products be approved to a Part II standard) Part III is the safety standard for power distribution and transmission circuits. Part IV is set of objective-based standards that may be used in certain industrial or institutional installations. Part VI establishes standards for the inspection of electrical installation in residential buildings.

Technical requirements of the Canadian Electrical Code are very similar to those of the U.S. National Electrical Code. Specific differences still exist and installations acceptable under one Code may not entirely comply with the other. Correlation of technical requirements between the two Codes is ongoing.

Several CE Code Part II electrical equipment standards have been harmonized with standards in the USA and Mexico through CANENA, The Council for the Harmonization of Electromechanical Standards of the Nations of the Americas (CANENA) is working to harmonize electrical codes in the western hemisphere.

Objective based code

In response to industry demand, CSA has developed Part IV of the Canadian Electrical Code, consisting of two standards CSA C22.4 No. 1 "Objective-based industrial electrical code" and CSA C22.4 No. 2 "Objective-based industrial electrical code - Safety management system requirements". These standards are intended for use only by authorized industrial users and would not apply, for example, to residential construction. These standards do not prescribe specific solutions for every case but instead give guidance to the user on achievement of the safety objectives of IEC 60364. Since it is less prescriptive, the OBIEC allows industrial users to use new technology not yet represented in the CE Code Part II. Use of this OBIEC is restricted to industrial and institutional users who have a safety management program in place and the engineering resources to implement the regulations. It is intended that users of the OBIEC will maintain safety while using methods that will reduce the installation cost of large industrial plants, for example, in the petrochemical business. [2] [3]

Related Research Articles

<span class="mw-page-title-main">Electrician</span> Tradesperson specializing in electrical wiring

An electrician is a tradesperson specializing in electrical wiring of buildings, transmission lines, stationary machines, and related equipment. Electricians may be employed in the installation of new electrical components or the maintenance and repair of existing electrical infrastructure. Electricians may also specialize in wiring ships, airplanes, and other mobile platforms, as well as data and cable lines.

Electrical wiring in North America follows the regulations and standards applicable at the installation location. It is also designed to provide proper function, and is also influenced by history and traditions of the location installation.

<span class="mw-page-title-main">National Electrical Code</span> Electrical wiring standard

The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association. Despite the use of the term "national", it is not a federal law. It is typically adopted by states and municipalities in an effort to standardize their enforcement of safe electrical practices. In some cases, the NEC is amended, altered and may even be rejected in lieu of regional regulations as voted on by local governing bodies.

<span class="mw-page-title-main">Mains electricity by country</span> Wikimedia list article

Mains electricity by country includes a list of countries and territories, with the plugs, voltages and frequencies they commonly use for providing electrical power to low voltage appliances, equipment, and lighting typically found in homes and offices. Some countries have more than one voltage available. For example, in North America most sockets are attached to a 120 V supply, but there is a 240 V supply available for large appliances. Often different sockets are mandated for different voltage or current levels.

<span class="mw-page-title-main">Electrical wiring</span> Electrical installation of cabling

Electrical wiring is an electrical installation of cabling and associated devices such as switches, distribution boards, sockets, and light fittings in a structure.

Electrical wiring in the United Kingdom is commonly understood to be an electrical installation for operation by end users within domestic, commercial, industrial, and other buildings, and also in special installations and locations, such as marinas or caravan parks. It does not normally cover the transmission or distribution of electricity to them.

The National Building Code of Canada is the model building code of Canada. It is issued by the National Research Council of Canada. As a model code, it has no legal status until it is adopted by a jurisdiction that regulates construction.

<span class="mw-page-title-main">Emergency light</span> Backup light source used in power outages

An emergency light is a battery-backed lighting device that switches on automatically when a building experiences a power outage.

British Standard BS 7671 "Requirements for Electrical Installations. IET Wiring Regulations", informally called in the UK electrical community "The Regs", is the national standard in the United Kingdom for electrical installation and the safety of electrical wiring in domestic, commercial, industrial, and other buildings, also in special installations and locations, such as marinas or caravan parks and medical locations

An earthing system or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect the safety and electromagnetic compatibility of the installation. Regulations for earthing systems vary considerably among countries, though most follow the recommendations of the International Electrotechnical Commission (IEC). Regulations may identify special cases for earthing in mines, in patient care areas, or in hazardous areas of industrial plants.

IEC 60364Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings. This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364". The latest versions of many European wiring regulations follow the section structure of IEC 60364 very closely, but contain additional language to cater for historic national practice and to simplify field use and determination of compliance by electricians and inspectors. National codes and site guides are meant to attain the common objectives of IEC 60364, and provide rules in a form that allows for guidance of persons installing and inspecting electrical systems.

<span class="mw-page-title-main">Extra-low voltage</span>

Extra-low voltage (ELV) is an electricity supply voltage and is a part of the Low voltage band in a range which carries a low risk of dangerous electrical shock. There are various standards that define extra-low voltage. The International Electrotechnical Commission (IEC) and the UK IET define an ELV device or circuit as one in which the electrical potential between conductor or electrical conductor and earth (ground) does not exceed 50 V AC or 120 V DC.

<span class="mw-page-title-main">Electrical equipment in hazardous areas</span> Electrical equipment in places where fire or explosion hazards may exist

In electrical and safety engineering, hazardous locations are places where fire or explosion hazards may exist. Sources of such hazards include gases, vapors, dust, fibers, and flyings, which are combustible or flammable. Electrical equipment installed in such locations could provide an ignition source, due to electrical arcing, or high temperature. Standards and regulations exist to identify such locations, classify the hazards, and design equipment for safe use in such locations.

<span class="mw-page-title-main">Product certification</span>

Product certification or product qualification is the process of certifying that a certain product has passed performance tests and quality assurance tests, and meets qualification criteria stipulated in contracts, regulations, or specifications.

Intrinsic safety (IS) is a protection technique for safe operation of electrical equipment in hazardous areas by limiting the energy, electrical and thermal, available for ignition. In signal and control circuits that can operate with low currents and voltages, the intrinsic safety approach simplifies circuits and reduces installation cost over other protection methods. Areas with dangerous concentrations of flammable gases or dust are found in applications such as petrochemical refineries and mines. As a discipline, it is an application of inherent safety in instrumentation. High-power circuits such as electric motors or lighting cannot use intrinsic safety methods for protection.

An electrical code is a set of regulations for the design and installation of electrical wiring in a building. The intention of a code is to provide standards to ensure electrical wiring systems that are safe for people and property.

In electrical engineering, low voltage is a relative term, the definition varying by context. Different definitions are used in electric power transmission and distribution, compared with electronics design. electrical safety codes define "low voltage" circuits that are exempt from the protection required at higher voltages. These definitions vary by country and specific codes or regulations.

Electrical safety testing is essential to make sure electrical products and electrical installations are safe. To meet this goal, governments and various technical bodies have developed electrical safety standards. All countries have their own electrical safety standards that must be complied with. To meet to these standards, electrical products and electrical installations must pass electrical safety tests.

<span class="mw-page-title-main">AC power plugs and sockets: British and related types</span> AC power plug type

Plugs and sockets for electrical appliances not hardwired to mains electricity originated in the United Kingdom in the 1870s and were initially two-pin designs. These were usually sold as a mating pair, but gradually de facto and then official standards arose to enable the interchange of compatible devices. British standards have proliferated throughout large parts of the former British Empire.

References

  1. Rick Gilmour (ed), Canadian Electrical Code Part 1, Safety Standard for Electrical Installations CSA Standard C22.1-06, Canadian Standards Association, Mississauga, Ontario 2006, ISBN   1-55436-023-4
  2. "Electrical Business". Industry News. 19 July 2008. Archived from the original on 10 July 2011. Retrieved 29 September 2022.
  3. "Objective Based Industrial Electrical Code Overview" (PDF). Canadian Standards Organization. 19 July 2008. Archived from the original (PDF) on 27 July 2011. Retrieved 29 September 2022.

See also