Electron avalanche

Last updated

An electron avalanche is a process in which a number of free electrons in a transmission medium are subjected to strong acceleration by an electric field and subsequently collide with other atoms of the medium, thereby ionizing them (impact ionization). This releases additional electrons which accelerate and collide with further atoms, releasing more electronsa chain reaction. In a gas, this causes the affected region to become an electrically conductive plasma.

Contents

The avalanche effect was discovered by John Sealy Townsend in his work between 1897 and 1901, and is also known as the Townsend discharge.

Electron avalanches are essential to the dielectric breakdown process within gases. The process can culminate in corona discharges, streamers, leaders, or in a spark or continuous arc that completely bridges the gap between the electrical conductors that are applying the voltage. The process extends to huge sparks — streamers in lightning discharges propagate by formation of electron avalanches created in the high potential gradient ahead of the streamers' advancing tips. Once begun, avalanches are often intensified by the creation of photoelectrons as a result of ultraviolet radiation emitted by the excited medium's atoms in the aft-tip region.

The process can also be used to detect ionizing radiation by using the gas multiplication effect of the avalanche process. This is the ionisation mechanism of the Geiger–Müller tube and, to a limited extent, of the proportional counter [1] and is also used in spark chambers and other wire chambers.

Analysis

A plasma begins with a rare natural 'background' ionization event of a neutral air molecule, perhaps as the result of photoexcitation or background radiation. If this event occurs within an area that has a high potential gradient, the positively charged ion will be strongly attracted toward, or repelled away from, an electrode depending on its polarity, whereas the electron will be accelerated in the opposite direction. Because of the huge mass difference, electrons are accelerated to a much higher velocity than ions.

High-velocity electrons often collide with neutral atoms inelastically, sometimes ionizing them. In a chain-reaction — or an 'electron avalanche' — additional electrons recently separated from their positive ions by the strong potential gradient, cause a large cloud of electrons and positive ions to be momentarily generated by just a single initial electron. However, free electrons are easily captured by neutral oxygen or water vapor molecules (so-called electronegative gases), forming negative ions. In air at STP, free electrons exist for only about 11 nanoseconds before being captured. Captured electrons are effectively removed from play — they can no longer contribute to the avalanche process. If electrons are being created at a rate greater than they are being lost to capture, their number rapidly multiplies, a process characterized by exponential growth. The degree of multiplication that this process can provide is huge, up to several million-fold depending on the situation. The multiplication factor M is given by

Where X1 and X2 are the positions that the multiplication is being measured between, and α is the ionization constant. In other words, one free electron at position X1 will result in M free electrons at position X2. Substituting the voltage gradients into this equation results in

Where V is the applied voltage, VBR is the breakdown voltage and n is an empirically derived value between 2 and 6. As can be seen from this formula, the multiplication factor is very highly dependent on the applied voltage, and as the voltage nears the breakdown voltage of the material, the multiplication factor approaches infinity and the limiting factor becomes the availability of charge carriers.

Avalanche sustenance requires a reservoir of charge to sustain the applied voltage, as well as a continual source of triggering events. A number of mechanisms can sustain this process, creating avalanche after avalanche, to create a corona current. A secondary source of plasma electrons is required as the electrons are always accelerated by the field in one direction, meaning that avalanches always proceed linearly toward or away from an electrode. The dominant mechanism for the creation of secondary electrons depends on the polarity of a plasma. In each case, the energy emitted as photons by the initial avalanche is used to ionise a nearby gas molecule creating another accelerable electron. What differs is the source of this electron. When one or more electron avalanches occur between two electrodes of sufficient size, complete avalanche breakdown can occur, culminating in an electrical spark that bridges the gap.

See also

Related Research Articles

A chain reaction is a sequence of reactions where a reactive product or by-product causes additional reactions to take place. In a chain reaction, positive feedback leads to a self-amplifying chain of events.

<span class="mw-page-title-main">Geiger–Müller tube</span> Part of a Geiger counter

The Geiger–Müller tube or G–M tube is the sensing element of the Geiger counter instrument used for the detection of ionizing radiation. It is named after Hans Geiger, who invented the principle in 1908, and Walther Müller, who collaborated with Geiger in developing the technique further in 1928 to produce a practical tube that could detect a number of different radiation types.

<span class="mw-page-title-main">Spark gap</span> Two conducting electrodes separated in order to allow an electric spark to pass between

A spark gap consists of an arrangement of two conducting electrodes separated by a gap usually filled with a gas such as air, designed to allow an electric spark to pass between the conductors. When the potential difference between the conductors exceeds the breakdown voltage of the gas within the gap, a spark forms, ionizing the gas and drastically reducing its electrical resistance. An electric current then flows until the path of ionized gas is broken or the current reduces below a minimum value called the "holding current". This usually happens when the voltage drops, but in some cases occurs when the heated gas rises, stretching out and then breaking the filament of ionized gas. Usually, the action of ionizing the gas is violent and disruptive, often leading to sound, light, and heat.

<span class="mw-page-title-main">Corona discharge</span> Ionization of air around a high-voltage conductor

A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air. A corona discharge occurs at locations where the strength of the electric field around a conductor exceeds the dielectric strength of the air. It is often seen as a bluish glow in the air adjacent to pointed metal conductors carrying high voltages, and emits light by the same mechanism as a gas discharge lamp. Corona discharges can also happen in weather, such as thunderstorms, where objects like ship masts or airplane wings have a charge significantly different from the air around them.

<span class="mw-page-title-main">Flashtube</span> Incoherent light source

A flashtube (flashlamp) is an electric arc lamp designed to produce extremely intense, incoherent, full-spectrum white light for a very short time. A flashtube is a glass tube with an electrode at each end and is filled with a gas that, when triggered, ionizes and conducts a high-voltage pulse to make light. Flashtubes are used most in photography; they also are used in science, medicine, industry, and entertainment.

<span class="mw-page-title-main">Gas-filled tube</span> Assembly of electrodes at either end of an insulated tube filled with gas

A gas-filled tube, also commonly known as a discharge tube or formerly as a Plücker tube, is an arrangement of electrodes in a gas within an insulating, temperature-resistant envelope. Gas-filled tubes exploit phenomena related to electric discharge in gases, and operate by ionizing the gas with an applied voltage sufficient to cause electrical conduction by the underlying phenomena of the Townsend discharge. A gas-discharge lamp is an electric light using a gas-filled tube; these include fluorescent lamps, metal-halide lamps, sodium-vapor lamps, and neon lights. Specialized gas-filled tubes such as krytrons, thyratrons, and ignitrons are used as switching devices in electric devices.

<span class="mw-page-title-main">Paschen's law</span> Physical law about electrical discharge in gases

Paschen's law is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. It is named after Friedrich Paschen who discovered it empirically in 1889.

<span class="mw-page-title-main">Electrical breakdown</span> Conduction of electricity through an insulator under sufficiently high voltage

In electronics, electrical breakdown or dielectric breakdown is a process that occurs when an electrically insulating material, subjected to a high enough voltage, suddenly becomes a conductor and current flows through it. All insulating materials undergo breakdown when the electric field caused by an applied voltage exceeds the material's dielectric strength. The voltage at which a given insulating object becomes conductive is called its breakdown voltage and, in addition to its dielectric strength, depends on its size and shape, and the location on the object at which the voltage is applied. Under sufficient voltage, electrical breakdown can occur within solids, liquids, or gases. However, the specific breakdown mechanisms are different for each kind of dielectric medium.

<span class="mw-page-title-main">Glow discharge</span> Plasma formed by passage of current through gas

A glow discharge is a plasma formed by the passage of electric current through a gas. It is often created by applying a voltage between two electrodes in a glass tube containing a low-pressure gas. When the voltage exceeds a value called the striking voltage, the gas ionization becomes self-sustaining, and the tube glows with a colored light. The color depends on the gas used.

<span class="mw-page-title-main">Proportional counter</span> Gaseous ionization detector

The proportional counter is a type of gaseous ionization detector device used to measure particles of ionizing radiation. The key feature is its ability to measure the energy of incident radiation, by producing a detector output pulse that is proportional to the radiation energy absorbed by the detector due to an ionizing event; hence the detector's name. It is widely used where energy levels of incident radiation must be known, such as in the discrimination between alpha and beta particles, or accurate measurement of X-ray radiation dose.

<span class="mw-page-title-main">Gaseous ionization detector</span> Radiation detector

Gaseous ionization detectors are radiation detection instruments used in particle physics to detect the presence of ionizing particles, and in radiation protection applications to measure ionizing radiation.

<span class="mw-page-title-main">Nitrogen laser</span>

A nitrogen laser is a gas laser operating in the ultraviolet range using molecular nitrogen as its gain medium, pumped by an electrical discharge.

A capacitively coupled plasma (CCP) is one of the most common types of industrial plasma sources. It essentially consists of two metal electrodes separated by a small distance, placed in a reactor. The gas pressure in the reactor can be lower than atmosphere or it can be atmospheric.

In electromagnetism, a leader is a hot, highly conductive channel of plasma that plays a critical part during dielectric breakdown within a long electric spark.

<span class="mw-page-title-main">Townsend discharge</span> Gas ionization process

In electromagnetism, the Townsend discharge or Townsend avalanche is an ionisation process for gases where free electrons are accelerated by an electric field, collide with gas molecules, and consequently free additional electrons. Those electrons are in turn accelerated and free additional electrons. The result is an avalanche multiplication that permits significantly increased electrical conduction through the gas. The discharge requires a source of free electrons and a significant electric field; without both, the phenomenon does not occur.

<span class="mw-page-title-main">Brush discharge</span>

A brush discharge is an electrical disruptive discharge similar to a corona discharge that takes place at an electrode with a high voltage applied to it, embedded in a nonconducting fluid, usually air. It is characterized by numerous luminous writhing sparks, plasma streamers composed of ionized air molecules, which repeatedly strike out from the electrode into the air, often with a crackling sound. The streamers spread out in a fan shape, giving it the appearance of a "brush".

Plasma activation is a method of surface modification employing plasma processing, which improves surface adhesion properties of many materials including metals, glass, ceramics, a broad range of polymers and textiles and even natural materials such as wood and seeds. Plasma functionalization also refers to the introduction of functional groups on the surface of exposed materials. It is widely used in industrial processes to prepare surfaces for bonding, gluing, coating and painting. Plasma processing achieves this effect through a combination of reduction of metal oxides, ultra-fine surface cleaning from organic contaminants, modification of the surface topography and deposition of functional chemical groups. Importantly, the plasma activation can be performed at atmospheric pressure using air or typical industrial gases including hydrogen, nitrogen and oxygen. Thus, the surface functionalization is achieved without expensive vacuum equipment or wet chemistry, which positively affects its costs, safety and environmental impact. Fast processing speeds further facilitate numerous industrial applications.

The Raether limit is the physical limiting value of the multiplication factor (M) or gas gain in an ionization avalanche process.

<span class="mw-page-title-main">Ion</span> Particle, atom or molecule with a net electrical charge

An ion is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convention. The net charge of an ion is not zero because its total number of electrons is unequal to its total number of protons.

<span class="mw-page-title-main">Streamer discharge</span> Type of transient electric discharge

In electromagnetism, a streamer discharge, also known as filamentary discharge, is a type of transient electric discharge which forms at the surface of a conductive electrode carrying a high voltage in an insulating medium such as air. Streamers are luminous writhing branching sparks, plasma channels composed of ionized air molecules, which repeatedly strike out from the electrode into the air.

References

  1. Glenn F Knoll, 'Radiation Detection and Measurement' 3rd edition, 2000, John Wiley and sons Inc.