Townsend discharge

Last updated
Avalanche effect in gas subject to ionising radiation between two plate electrodes. The original ionisation event liberates one electron, and each subsequent collision liberates a further electron, so two electrons emerge from each collision to sustain the avalanche. Electron avalanche.gif
Avalanche effect in gas subject to ionising radiation between two plate electrodes. The original ionisation event liberates one electron, and each subsequent collision liberates a further electron, so two electrons emerge from each collision to sustain the avalanche.

In electromagnetism, the Townsend discharge or Townsend avalanche is an ionisation process for gases where free electrons are accelerated by an electric field, collide with gas molecules, and consequently free additional electrons. Those electrons are in turn accelerated and free additional electrons. The result is an avalanche multiplication that permits significantly increased electrical conduction through the gas. The discharge requires a source of free electrons and a significant electric field; without both, the phenomenon does not occur.

Contents

The Townsend discharge is named after John Sealy Townsend, who discovered the fundamental ionisation mechanism by his work circa 1897 at the Cavendish Laboratory, Cambridge.

General description

The avalanche occurs in a gaseous medium that can be ionised (such as air). The electric field and the mean free path of the electron must allow free electrons to acquire an energy level (velocity) that can cause impact ionisation. If the electric field is too small, then the electrons do not acquire enough energy. If the mean free path is too short, the electron gives up its acquired energy in a series of non-ionising collisions. If the mean free path is too long, then the electron reaches the anode before colliding with another molecule.

The avalanche mechanism is shown in the accompanying diagram. The electric field is applied across a gaseous medium; initial ions are created with ionising radiation (for example, cosmic rays). An original ionisation event produces an ion pair; the positive ion accelerates towards the cathode while the free electron accelerates towards the anode. If the electric field is strong enough, the free electron can gain sufficient velocity (energy) to liberate another electron when it next collides with a molecule. The two free electrons then travel towards the anode and gain sufficient energy from the electric field to cause further impact ionisations, and so on. This process is effectively a chain reaction that generates free electrons. [1] Initially, the number of collisions grows exponentially. The total number of electrons reaching the anode is equal to 2n with n the number of collisions, plus the single initiating free electron. Eventually, this relationship will break down - the limit to the multiplication in an electron avalanche is known as the Raether limit.

The Townsend avalanche can have a large range of current densities. In common gas-filled tubes, such as those used as gaseous ionisation detectors, magnitudes of currents flowing during this process can range from about 1018 amperes to about 105 amperes.[ citation needed ]

Quantitative description

Townsend's early experimental apparatus consisted of planar parallel plates forming two sides of a chamber filled with a gas. A direct current high-voltage source was connected between the plates; the lower plate being the cathode while the other was the anode. He forced the cathode to emit electrons using the photoelectric effect by irradiating it with X-rays, and he found that the current I flowing through the chamber depended on the electric field between the plates. However, this current showed an exponential increase as the plate gaps became small[ disputed ], leading to the conclusion that the gas ions were multiplying as they moved between the plates due to the high electric field.

Townsend observed currents varying exponentially over ten or more orders of magnitude with a constant applied voltage when the distance between the plates was varied. He also discovered that gas pressure influenced conduction: he was able to generate ions in gases at low pressure with a much lower voltage than that required to generate a spark. This observation overturned conventional thinking about the amount of current that an irradiated gas could conduct. [2]

The experimental data obtained from his experiments are described by the following formula

where

The almost constant voltage[ which? ] between the plates is equal to the breakdown voltage needed to create a self-sustaining avalanche: it decreases when the current reaches the glow discharge regime.[ clarification needed ] Subsequent experiments revealed that the current I rises faster than predicted by the above formula as the distance d increases: two different effects were considered in order to better model the discharge: positive ions and cathode emission.

Gas ionisation caused by motion of positive ions

Townsend put forward the hypothesis that positive ions also produce ion pairs, introducing a coefficient expressing the number of ion pairs generated per unit length by a positive ion (cation) moving from anode to cathode. The following formula was found

since , in very good agreement with experiments.

The first Townsend coefficient ( α ), also known as first Townsend avalanche coefficient is a term used where secondary ionisation occurs because the primary ionisation electrons gain sufficient energy from the accelerating electric field, or from the original ionising particle. The coefficient gives the number of secondary electrons produced by primary electron per unit path length.

Cathode emission caused by impact of ions

Townsend, Holst and Oosterhuis also put forward an alternative hypothesis, considering the augmented emission of electrons by the cathode caused by impact of positive ions. This introduced Townsend's second ionisation coefficient; the average number of electrons released from a surface by an incident positive ion, according to the following formula:

These two formulas may be thought as describing limiting cases of the effective behavior of the process: either can be used to describe the same experimental results. Other formulas describing various intermediate behaviors are found in the literature, particularly in reference 1 and citations therein.

Conditions

Voltage-current characteristics of electrical discharge in neon at 1 torr, with two planar electrodes separated by 50 cm.
A: random pulses by cosmic radiation
B: saturation current
C: avalanche Townsend discharge
D: self-sustained Townsend discharge
E: unstable region: corona discharge
F: sub-normal glow discharge
G: normal glow discharge
H: abnormal glow discharge
I: unstable region: glow-arc transition
J: electric arc
K: electric arc
A-D region: dark discharge; ionisation occurs, current below 10 microamps.
F-H region: glow discharge; the plasma emits a faint glow.
I-K region: arc discharge; large amounts of radiation produced. Glow discharge current-voltage curve English.svg
Voltage-current characteristics of electrical discharge in neon at 1 torr, with two planar electrodes separated by 50 cm.
A: random pulses by cosmic radiation
B: saturation current
C: avalanche Townsend discharge
D: self-sustained Townsend discharge
E: unstable region: corona discharge
F: sub-normal glow discharge
G: normal glow discharge
H: abnormal glow discharge
I: unstable region: glow-arc transition
J: electric arc
K: electric arc
A-D region: dark discharge; ionisation occurs, current below 10 microamps.
F-H region: glow discharge; the plasma emits a faint glow.
I-K region: arc discharge; large amounts of radiation produced.

A Townsend discharge can be sustained only over a limited range of gas pressure and electric field intensity. The accompanying plot shows the variation of voltage drop and the different operating regions for a gas-filled tube with a constant pressure, but a varying current between its electrodes. The Townsend avalanche phenomena occurs on the sloping plateau B-D. Beyond D the ionisation is sustained.

At higher pressures, discharges occur more rapidly than the calculated time for ions to traverse the gap between electrodes, and the streamer theory of spark discharge of Raether, Meek, and Loeb is applicable. In highly non-uniform electric fields, the corona discharge process is applicable. See Electron avalanche for further description of these mechanisms.

Discharges in vacuum require vaporization and ionisation of electrode atoms. An arc can be initiated without a preliminary Townsend discharge; for example when electrodes touch and are then separated.

Penning discharge

In the presence of a magnetic field, the likelihood of an avalanche discharge occurring under high vacuum conditions can be increased through a phenomenon known as Penning discharge. This occurs when electrons can become trapped within a potential minimum, thereby extending the mean free path of the electrons [Fränkle 2014].

Applications

Gas-discharge tubes

The starting of Townsend discharge sets the upper limit to the blocking voltage a glow discharge gas-filled tube can withstand. This limit is the Townsend discharge breakdown voltage, also called ignition voltage of the tube.

Neon lamp/cold-cathode gas diode relaxation oscillator Tube relaxation oscillator.jpg
Neon lamp/cold-cathode gas diode relaxation oscillator

The occurrence of Townsend discharge, leading to glow discharge breakdown shapes the current–voltage characteristic of a gas-discharge tube such as a neon lamp in a way such that it has a negative differential resistance region of the S-type. The negative resistance can be used to generate electrical oscillations and waveforms, as in the relaxation oscillator whose schematic is shown in the picture on the right. The sawtooth shaped oscillation generated has frequency

where
Since temperature and time stability of the characteristics of gas diodes and neon lamps is low, and also the statistical dispersion of breakdown voltages is high, the above formula can only give a qualitative indication of what the real frequency of oscillation is.

Gas phototubes

Avalanche multiplication during Townsend discharge is naturally used in gas phototubes, to amplify the photoelectric charge generated by incident radiation (visible light or not) on the cathode: achievable current is typically 10~20 times greater respect to that generated by vacuum phototubes.

Ionising radiation detectors

Plot of variation of ionisation current against applied voltage for a co-axial wire cylinder gaseous radiation detector. Detector regions.gif
Plot of variation of ionisation current against applied voltage for a co-axial wire cylinder gaseous radiation detector.

Townsend avalanche discharges are fundamental to the operation of gaseous ionisation detectors such as the Geiger–Müller tube and the proportional counter in either detecting ionising radiation or measuring its energy. The incident radiation will ionise atoms or molecules in the gaseous medium to produce ion pairs, but different use is made by each detector type of the resultant avalanche effects.

In the case of a GM tube the high electric field strength is sufficient to cause complete ionisation of the fill gas surrounding the anode from the initial creation of just one ion pair. The GM tube output carries information that the event has occurred, but no information about the energy of the incident radiation. [1]

In the case of proportional counters, multiple creation of ion pairs occurs in the "ion drift" region near the cathode. The electric field and chamber geometries are selected so that an "avalanche region" is created in the immediate proximity of the anode. A negative ion drifting towards the anode enters this region and creates a localised avalanche that is independent of those from other ion pairs, but which can still provide a multiplication effect. In this way spectroscopic information on the energy of the incident radiation is available by the magnitude of the output pulse from each initiating event. [1]

The accompanying plot shows the variation of ionisation current for a co-axial cylinder system. In the ion chamber region, there are no avalanches and the applied voltage only serves to move the ions towards the electrodes to prevent re-combination. In the proportional region, localised avalanches occur in the gas space immediately round the anode which are numerically proportional to the number of original ionising events. Increasing the voltage further increases the number of avalanches until the Geiger region is reached where the full volume of the fill gas around the anodes ionised, and all proportional energy information is lost. [1] Beyond the Geiger region the gas is in continuous discharge owing to the high electric field strength.

See also

Notes

  1. 1 2 3 4 Glenn F Knoll. Radiation Detection and Measurement, third edition 2000. John Wiley and sons, ISBN   0-471-07338-5
  2. John Sealy Edward Townsend. 1868-1957 by A. von Engel. Biographical Memoirs of Fellows of the Royal Society. 1957 3, 256-272

Related Research Articles

<span class="mw-page-title-main">Cathode ray</span> Beam of electrons observed in vacuum tubes

Cathode rays or electron beams (e-beam) are streams of electrons observed in discharge tubes. If an evacuated glass tube is equipped with two electrodes and a voltage is applied, glass behind the positive electrode is observed to glow, due to electrons emitted from the cathode. They were first observed in 1859 by German physicist Julius Plücker and Johann Wilhelm Hittorf, and were named in 1876 by Eugen Goldstein Kathodenstrahlen, or cathode rays. In 1897, British physicist J. J. Thomson showed that cathode rays were composed of a previously unknown negatively charged particle, which was later named the electron. Cathode-ray tubes (CRTs) use a focused beam of electrons deflected by electric or magnetic fields to render an image on a screen.

<span class="mw-page-title-main">Cathode</span> Electrode where reduction takes place

A cathode is the electrode from which a conventional current leaves a polarized electrical device. This definition can be recalled by using the mnemonic CCD for Cathode Current Departs. A conventional current describes the direction in which positive charges move. Electrons have a negative electrical charge, so the movement of electrons is opposite to that of the conventional current flow. Consequently, the mnemonic cathode current departs also means that electrons flow into the device's cathode from the external circuit. For example, the end of a household battery marked with a + (plus) is the cathode.

<span class="mw-page-title-main">Geiger–Müller tube</span> Part of a Geiger counter

The Geiger–Müller tube or G–M tube is the sensing element of the Geiger counter instrument used for the detection of ionizing radiation. It is named after Hans Geiger, who invented the principle in 1908, and Walther Müller, who collaborated with Geiger in developing the technique further in 1928 to produce a practical tube that could detect a number of different radiation types.

<span class="mw-page-title-main">Cold cathode</span> Type of electrode and part of cold cathode fluorescent lamp.

A cold cathode is a cathode that is not electrically heated by a filament. A cathode may be considered "cold" if it emits more electrons than can be supplied by thermionic emission alone. It is used in gas-discharge lamps, such as neon lamps, discharge tubes, and some types of vacuum tube. The other type of cathode is a hot cathode, which is heated by electric current passing through a filament. A cold cathode does not necessarily operate at a low temperature: it is often heated to its operating temperature by other methods, such as the current passing from the cathode into the gas.

<span class="mw-page-title-main">Corona discharge</span> Ionization of air around a high-voltage conductor

A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air. A corona discharge occurs at locations where the strength of the electric field around a conductor exceeds the dielectric strength of the air. It is often seen as a bluish glow in the air adjacent to pointed metal conductors carrying high voltages, and emits light by the same mechanism as a gas discharge lamp. Corona discharges can also happen in weather, such as thunderstorms, where objects like ship masts or airplane wings have a charge significantly different from the air around them.

<span class="mw-page-title-main">Gas-filled tube</span> Assembly of electrodes at either end of an insulated tube filled with gas

A gas-filled tube, also commonly known as a discharge tube or formerly as a Plücker tube, is an arrangement of electrodes in a gas within an insulating, temperature-resistant envelope. Gas-filled tubes exploit phenomena related to electric discharge in gases, and operate by ionizing the gas with an applied voltage sufficient to cause electrical conduction by the underlying phenomena of the Townsend discharge. A gas-discharge lamp is an electric light using a gas-filled tube; these include fluorescent lamps, metal-halide lamps, sodium-vapor lamps, and neon lights. Specialized gas-filled tubes such as krytrons, thyratrons, and ignitrons are used as switching devices in electric devices.

<span class="mw-page-title-main">Paschen's law</span> Physical law about electrical discharge in gases

Paschen's law is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. It is named after Friedrich Paschen who discovered it empirically in 1889.

<span class="mw-page-title-main">Glow discharge</span> Plasma formed by passage of current through gas

A glow discharge is a plasma formed by the passage of electric current through a gas. It is often created by applying a voltage between two electrodes in a glass tube containing a low-pressure gas. When the voltage exceeds a value called the striking voltage, the gas ionization becomes self-sustaining, and the tube glows with a colored light. The color depends on the gas used.

<span class="mw-page-title-main">X-ray tube</span> Vacuum tube that converts electrical input power into X-rays

An X-ray tube is a vacuum tube that converts electrical input power into X-rays. The availability of this controllable source of X-rays created the field of radiography, the imaging of partly opaque objects with penetrating radiation. In contrast to other sources of ionizing radiation, X-rays are only produced as long as the X-ray tube is energized. X-ray tubes are also used in CT scanners, airport luggage scanners, X-ray crystallography, material and structure analysis, and for industrial inspection.

<span class="mw-page-title-main">Proportional counter</span> Gaseous ionization detector

The proportional counter is a type of gaseous ionization detector device used to measure particles of ionizing radiation. The key feature is its ability to measure the energy of incident radiation, by producing a detector output pulse that is proportional to the radiation energy absorbed by the detector due to an ionizing event; hence the detector's name. It is widely used where energy levels of incident radiation must be known, such as in the discrimination between alpha and beta particles, or accurate measurement of X-ray radiation dose.

<span class="mw-page-title-main">Anode ray</span> Beam of positively charged ions

An anode ray is a beam of positive ions that is created by certain types of gas-discharge tubes. They were first observed in Crookes tubes during experiments by the German scientist Eugen Goldstein, in 1886. Later work on anode rays by Wilhelm Wien and J. J. Thomson led to the development of mass spectrometry.

A vacuum arc can arise when the surfaces of metal electrodes in contact with a good vacuum begin to emit electrons either through heating or in an electric field that is sufficient to cause field electron emission. Once initiated, a vacuum arc can persist, since the freed particles gain kinetic energy from the electric field, heating the metal surfaces through high-speed particle collisions. This process can create an incandescent cathode spot, which frees more particles, thereby sustaining the arc. At sufficiently high currents an incandescent anode spot may also be formed.

The ionization chamber is the simplest type of gaseous ionisation detector, and is widely used for the detection and measurement of many types of ionizing radiation, including X-rays, gamma rays, alpha particles and beta particles. Conventionally, the term "ionization chamber" refers exclusively to those detectors which collect all the charges created by direct ionization within the gas through the application of an electric field. It uses the discrete charges created by each interaction between the incident radiation and the gas to produce an output in the form of a small direct current. This means individual ionising events cannot be measured, so the energy of different types of radiation cannot be differentiated, but it gives a very good measurement of overall ionising effect.

<span class="mw-page-title-main">Crookes tube</span> Early type of cathode ray tube

A Crookes tube is an early experimental electrical discharge tube, with partial vacuum, invented by English physicist William Crookes and others around 1869-1875, in which cathode rays, streams of electrons, were discovered.

<span class="mw-page-title-main">Gaseous ionization detector</span> Radiation detector

Gaseous ionization detectors are radiation detection instruments used in particle physics to detect the presence of ionizing particles, and in radiation protection applications to measure ionizing radiation.

An electron avalanche is a process in which a number of free electrons in a transmission medium are subjected to strong acceleration by an electric field and subsequently collide with other atoms of the medium, thereby ionizing them. This releases additional electrons which accelerate and collide with further atoms, releasing more electrons—a chain reaction. In a gas, this causes the affected region to become an electrically conductive plasma.

Plasma activation is a method of surface modification employing plasma processing, which improves surface adhesion properties of many materials including metals, glass, ceramics, a broad range of polymers and textiles and even natural materials such as wood and seeds. Plasma functionalization also refers to the introduction of functional groups on the surface of exposed materials. It is widely used in industrial processes to prepare surfaces for bonding, gluing, coating and painting. Plasma processing achieves this effect through a combination of reduction of metal oxides, ultra-fine surface cleaning from organic contaminants, modification of the surface topography and deposition of functional chemical groups. Importantly, the plasma activation can be performed at atmospheric pressure using air or typical industrial gases including hydrogen, nitrogen and oxygen. Thus, the surface functionalization is achieved without expensive vacuum equipment or wet chemistry, which positively affects its costs, safety and environmental impact. Fast processing speeds further facilitate numerous industrial applications.

<span class="mw-page-title-main">Frans Michel Penning</span> Dutch physicist (1894–1953)

Frans Michel Penning was a Dutch experimental physicist. He received his PhD from the University of Leiden in 1923, and studied low pressure gas discharges at the Philips Laboratory in Eindhoven, developing new electron tubes during World War II. Many detailed observations of gas ionization were done with colleagues, finding notable results for helium and magnetic fields. He made precise measurements of Townsend discharge coefficients and cathode voltage fall. Penning made important contributions to the advancement of high resolution mass spectrometry.

The gaseous detection device (GDD) is a method and apparatus for the detection of signals in the gaseous environment of an environmental scanning electron microscope (ESEM) and all scanned beam type of instruments that allow a minimum gas pressure for the detector to operate.

<span class="mw-page-title-main">Noise generator</span> Circuit that produces electrical noise

A noise generator is a circuit that produces electrical noise. Noise generators are used to test signals for measuring noise figure, frequency response, and other parameters. Noise generators are also used for generating random numbers.

References