Neutron detection

Last updated

Neutron detection is the effective detection of neutrons entering a well-positioned detector. There are two key aspects to effective neutron detection: hardware and software. Detection hardware refers to the kind of neutron detector used (the most common today is the scintillation detector) and to the electronics used in the detection setup. Further, the hardware setup also defines key experimental parameters, such as source-detector distance, solid angle and detector shielding. Detection software consists of analysis tools that perform tasks such as graphical analysis to measure the number and energies of neutrons striking the detector.

Contents

Basic physics

Signatures by which a neutron may be detected

Atomic and subatomic particles are detected by the signature they produce through interaction with their surroundings. The interactions result from the particles' fundamental characteristics.


n0

p+
+
e
+
ν
e
.
Although the
p+
and
e
produced by neutron decay are detectable, the decay rate is too low to serve as the basis for a practical detector system.

Classic neutron detection options

As a result of these properties, detection of neutrons fall into several major categories: [3]

Types of neutron detectors

Gas proportional detectors

Gas proportional detectors can be adapted to detect neutrons. While neutrons do not typically cause ionization, the addition of a nuclide with high neutron cross-section allows the detector to respond to neutrons. Nuclides commonly used for this purpose are helium-3, lithium-6, boron-10 and uranium-235. Since these materials are most likely to react with thermal neutrons (i.e., neutrons that have slowed to equilibrium with their surroundings), they are typically surrounded by moderating materials to reduce their energy and increase the likelihood of detection.

Further refinements are usually necessary to differentiate the neutron signal from the effects of other types of radiation. Since the energy of a thermal neutron is relatively low, charged particle reactions are discrete (i.e., essentially monoenergetic and lie within a narrow bandwidth of energies) while other reactions such as gamma reactions will span a broad energy range, it is possible to discriminate among the sources.

As a class, gas ionization detectors measure the number (count rate), and not the energy of neutrons.

3He gas-filled proportional detectors

Helium-3 is an effective neutron detector material because it reacts by absorbing thermal neutrons, producing a 1H and 3H ion. Its sensitivity to gamma rays is negligible, providing a very useful neutron detector. Unfortunately the supply of 3He is limited to production as a byproduct from the decay of tritium (which has a 12.3 year half-life); tritium is produced either as part of weapons programs as a booster for nuclear weapons or as a byproduct of reactor operation.

BF3 gas-filled proportional detectors

As elemental boron is not gaseous, neutron detectors containing boron may alternately use boron trifluoride (BF3) enriched to 96% boron-10 (natural boron is 20% 10B, 80% 11B). [5] Boron trifluoride is highly toxic. The sensitivity of this detector is around 35-40 CPS/nv (counts per second per neutron flux) whereas that of Boron lined is about 4 CPS/nv. This is because in Boron lined, n reacts with Boron and hence produce ion pairs inside the layer. Hence charged particles produced (Alpha and Li) they lose some of their energy inside that layer. Low energy charged particles are unable to reach the Ionization chamber's gas environment. Hence, the number of ionizations produced in gas is also lower.

Whereas In BF3 gas filled, N reacts with B in gas and fully energetic Alpha and Li are able to produce more ionizations and give more pulses.

Boron lined proportional detectors

Alternately, boron-lined gas-filled proportional counters react similarly to BF3 gas-filled proportional detectors, with the exception that the walls are coated with 10B. In this design, since the reaction takes place on the surface, only one of the two particles will escape into the proportional counter.

Scintillation neutron detectors

Scintillation neutron detectors include liquid organic scintillators, [6] crystals, [7] [8] plastics, glass [9] and scintillation fibers. [10]

Neutron-sensitive scintillating glass fiber detectors

Scintillating 6Li glass for neutron detection was first reported in the scientific literature in 1957 [11] and key advances were made in the 1960s and 1970s. [12] [13] Scintillating fiber was demonstrated by Atkinson M. et al. in 1987 [14] and major advances were made in the late 1980s and early 1990s at Pacific Northwest National Laboratory where it was developed as a classified technology. [15] [16] [17] [18] [19] It was declassified in 1994 and first licensed by Oxford Instruments in 1997, followed by a transfer to Nucsafe in 1999. [20] [21] [22] The fiber and fiber detectors are now manufactured and sold commercially by Nucsafe, Inc. [23]

The scintillating glass fibers work by incorporating 6Li and Ce3+ into the glass bulk composition. The 6Li has a high cross-section for thermal neutron absorption through the 6Li(n,α) reaction. Neutron absorption produces a tritium ion, an alpha particle, and kinetic energy. The alpha particle and triton interact with the glass matrix to produce ionization, which transfers energy to Ce3+ ions and results in the emission of photons with wavelength 390 nm - 600 nm as the excited state Ce3+ ions return to the ground state. The event results in a flash of light of several thousand photons for each neutron absorbed. A portion of the scintillation light propagates through the glass fiber, which acts as a waveguide. The fibers ends are optically coupled to a pair of photomultiplier tubes (PMTs) to detect photon bursts. The detectors can be used to detect both neutrons and gamma rays, which are typically distinguished using pulse-height discrimination. Substantial effort and progress in reducing fiber detector sensitivity to gamma radiation has been made. Original detectors suffered from false neutrons in a 0.02 mR gamma field. Design, process, and algorithm improvements now enable operation in gamma fields up to 20 mR/h (60Co).

The scintillating fiber detectors have excellent sensitivity, they are rugged, and have fast timing (~60 ns) so that a large dynamic range in counting rates is possible. The detectors have the advantage that they can be formed into any desired shape, and can be made very large or very small for use in a variety of applications. [24] Further, they do not rely on 3He or any raw material that has limited availability, nor do they contain toxic or regulated materials. Their performance matches or exceeds that of 3He tubes for gross neutron counting due to the higher density of neutron absorbing species in the solid glass compared to high-pressure gaseous 3He. [24] Even though the thermal neutron cross section of 6Li is low compared to 3He (940 barns vs. 5330 barns), the atom density of 6Li in the fiber is fifty times greater, resulting in an advantage in effective capture density ratio of approximately 10:1.

LiCaAlF6

LiCaAlF6 is a neutron sensitive inorganic scintillator crystal which like neutron-sensitive scintillating glass fiber detectors makes use of neutron capture by 6Li. Unlike scintillating glass fiber detectors however the 6Li is part of the crystalline structure of the scintillator giving it a naturally high 6Li density. A doping agent is added to provide the crystal with its scintillating properties, two common doping agents are trivalent cerium and divalent europium. Europium doped LiCaAlF6 has the advantage over other materials that the number of optical photons produced per neutron capture is around 30.000 which is 5 times higher than for example in neutron-sensitive scintillating glass fibers. [25] This property makes neutron photon discrimination easier. Due to its high 6Li density this material is suitable for producing light weight compact neutron detectors, as a result LiCaAlF6 has been used for neutron detection at high altitudes on balloon missions. [26] The long decay time of Eu2+ doped LiCaAlF6 makes it less suitable for measurements in high radiation environments, the Ce3+ doped variant has a shorter decay time but suffers from a lower light-yield. [27]

NaIL Dual Detection Neutron-Gamma Scintillator

Sodium Iodide crystal co-doped with Thallium and Lithium [NaI(Tl+Li)] a.k.a. NaIL has the ability to detect Gamma radiation and Thermal Neutrons in a single crystal with exceptional Pulse-shape Discrimination.The use of low 6Li concentrations in NaIL and large thicknesses can achieve the same neutron detection capabilities as 3He or CLYC or CLLB detectors at a lower cost.6Li (95% enriched) co-doping introduces efficient thermal neutron detection to the most established gamma-ray scintillator while retaining the favorable scintillation properties of standard NaI(Tl). NaIL can provide large volume, single material detectors for both gammas and neutrons at a low price per volume. [28] [29] [30]

Semiconductor neutron detectors

There are two basic types of semiconductor neutron detectors, the first being electron devices coated with a neutron reactive material and the second being a semiconductor being partly composed of neutron reactive material. [31] The most successful of these configurations is the coated device type, and an example would be a common planar Si diode coated with either 10B or 6LiF. [32] [33] This type of detector was first proposed by Babcock et al. [34] The concept is straightforward. A neutron is absorbed in the reactive film and spontaneously emits energetic reaction products. A reaction product may reach the semiconductor surface, and upon entering the semiconductor produces electron-hole pairs. Under a reverse bias voltage, these electrons and holes are drifted through the diode to produce an induced current, usually integrated in pulse mode to form a voltage output. The maximum intrinsic efficiency for single-coated devices is approximately 5% for thermal neutrons (0.0259 eV), and the design and operation are thoroughly described in the literature. [35] The neutron detection efficiency limitation is a consequence of reaction-product self-absorption. For instance, the range in a boron film of 1.47 MeV α particles from the 10B(n,α) 7Li reaction is approximately 4.5 microns, and the range in LiF of 2.7 MeV tritons from the 10B(n,α) 7Li reaction is approximately 28 microns. Reaction products originating at distances further from the film/semiconductor interface can not reach the semiconductor surface, and consequently will not contribute to neutron detection. Devices coated with natural Gd have also been explored, mainly because of its large thermal neutron microscopic cross section of 49,000 barns. [36] [37] However, the Gd(n,γ) reaction products of interest are mainly low energy conversion electrons, mostly grouped around 70 keV. Consequently, discrimination between neutron induced events and gamma-ray events (mainly producing Compton scattered electrons) is difficult for Gd-coated semiconductor diodes. A compensated pixel design sought to remedy the problem. [38] Overall, devices coated with either 10B or 6LiF are preferred mainly because the energetic charged-particle reaction products are much easier to discriminate from background radiations.

The low efficiency of coated planar diodes led to the development of microstructured semiconductor neutron detectors (MSND). These detectors have microscopic structures etched into a semiconductor substrate, subsequently formed into a pin style diode. The microstructures are backfilled with neutron reactive material, usually 6LiF, although 10B has been used. The increased semiconductor surface area adjacent to the reactive material and the increased probability that a reaction product will enter the semiconductor greatly increase the intrinsic neutron detection efficiency. [39]

Basic design of a microstructured semiconductor neutron detector (MSND). Basic design of a microstructured semiconductor neutron detector (MSND).jpg
Basic design of a microstructured semiconductor neutron detector (MSND).

The MSND device configuration was first proposed by Muminov and Tsvang, [41] and later by Schelten et al. [42] It was years later when the first working example of a MSND was fabricated and demonstrated [43] , [44] then having only 3.3% thermal neutron detection efficiency. Since that initial work, MSNDs have achieved greater than 30% thermal neutron detection efficiency. [45] Although MSNDs can operate on the built-in potential (zero applied voltage), they perform best when 2-3 volts are applied. There are several groups now working on MSND variations. [46] [47] The most successful types are the variety backfilled with 6LiF material. MSNDs are now manufactured and sold commercially by Radiation Detection Technologies, Inc. [48] Advanced experimental versions of double-sided MSNDs with opposing microstructures on both sides of a semiconductor wafer have been reported with over 65% thermal neutron detection efficiency, [49] and are theoretically capable of over 70% efficiency.

Semiconductor detectors in which one of more constituent atoms are neutron reactive are called bulk semiconductor neutron detectors. Bulk solid-state neutron detectors can be divided into two basic categories: those that rely on the detection of charged-particle reaction products and those that rely on the detection of prompt capture gamma rays. In general, this type of neutron detector is difficult to make reliably and presently are not commercially available.

The bulk materials that rely upon charged-particle emissions are based on boron and lithium containing semiconductors. In the search for bulk semiconductor neutron detectors, the boron-based materials, such as BP, BAs, BN, and B4C, have been investigated more than other potential materials. [50] [51] [52] [53] [54] [55]

Boron-based semiconductors in cubic form are difficult to grow as bulk crystals, mainly because they require high temperatures and high pressure for synthesis. BP and Bas can decompose into undesirable crystal structures (cubic to icosahedral form) unless synthesized under high pressure. B4C also forms icosahedral units in a rhombohedral crystal structure, an undesirable transformation because the icosahedral structure has relatively poor charge collection properties [56] which make these icosahedral forms unsuitable for neutron detection.

BN can be formed as either simple hexagonal, cubic (zincblende) or wurtzite crystals, depending on the growth temperature, and it is usually grown by thin film methods. It is the simple hexagonal form of BN that has been most studied as a neutron detector. Thin film chemical vapor deposition methods are usually employed to produce BP, BAs, BN, or B4C. These boron-based films are often grown upon n-type Si substrates, which can form a pn junction with the Si and, therefore, produce a coated Si diode as described at the beginning of this section. Consequently, the neutron response from the device can be easily mistaken as a bulk response when it is actually a coated diode response. To date, there is sparse evidence of boron-based semiconductors producing intrinsic neutron signals.

Li-containing semiconductors, categorized as Nowotny-Juza compounds, have also been investigated as bulk neutron detectors. The Nowotny-Juza compound LiZnAs has been demonstrated as a neutron detector; [57] however, the material is difficult and expensive to synthesize, and only small semiconductor crystals have been reported. Finally, traditional semiconductor materials with neutron reactive dopants have been investigated, namely, Si(Li) detectors. Neutrons interact with the lithium dopant in the material and produce energetic reaction products. However, the dopant concentration is relatively low in Li drifted Si detectors (or other doped semiconductors), typically less than 1019 cm−3. For a degenerate concentration of Li on the order of 1019 cm−3, a 5-cm thick block of natural Si(Li) would have less than 1% thermal-neutron detection efficiency, while a 5-cm thick block of a Si(6Li) detector would have only 4.6% thermal-neutron detection efficiency.

Prompt gamma-ray emitting semiconductors, such as CdTe, [58] [59] and HgI2 [60] [61] have been successfully used as neutron detectors. These detectors rely upon the prompt gamma-ray emissions from the 113Cd(n, γ)114Cd reaction (producing 558.6 keV and 651.3 keV gamma rays) and the 199Hg(n, γ) 200Hg reaction (producing 368.1 keV and 661.1 keV gamma rays). However, these semiconductor materials are designed for use as gamma-ray spectrometers and, hence, are intrinsically sensitive to the gamma-ray background. With adequate energy resolution, pulse height discrimination can be used to separate the prompt gamma-ray emissions from neutron interactions. However, the effective neutron detection efficiency is compromised because of the relatively small Compton ratio. In other words, the majority of events add to the Compton continuum rather than to the full energy peak, thus, making discrimination between neutrons and background gamma rays difficult. Also, both natural Cd and Hg have relatively large thermal-neutron (n,γ) cross sections of 2444 b and 369.8 b, respectively. Consequently, most thermal neutrons are absorbed near the detector surface so that nearly half of the prompt gamma rays are emitted in directions away from the detector bulk and, thus, produce poor gamma-ray reabsorption or interaction efficiency.

Neutron activation detectors

Activation samples may be placed in a neutron field to characterize the energy spectrum and intensity of the neutrons. Activation reactions that have differing energy thresholds can be used including 56Fe(n,p) 56Mn, 27Al(n,α)24Na, 93Nb(n,2n) 92mNb, & 28Si(n,p)28Al. [62]

Fast neutron detectors

Fast neutrons are often detected by first moderating (slowing) them to thermal energies. However, during that process the information on the original energy of the neutron, its direction of travel, and the time of emission is lost. For many applications, the detection of “fast” neutrons that retain this information is highly desirable. [63]

Typical fast neutron detectors are liquid scintillators, [64] 4-He based noble gas detectors [65] and plastic detectors. Fast neutron detectors differentiate themselves from one another by their 1.) capability of neutron/gamma discrimination (through pulse shape discrimination) and 2.) sensitivity. The capability to distinguish between neutrons and gammas is excellent in noble gas based 4-He detectors due to their low electron density and excellent pulse shape discrimination property. In fact, inorganic scintillators such as zinc sulfide has been shown to exhibit large differences in their decay times for protons and electrons; a feature that has been exploited by combining the inorganic crystal with a neutron converter (such as polymethyl methacrylate) in the Micro-Layered Fast-Neutron Detector. [66] Such detection systems are capable of selectively detecting only fast neutrons in a mixed neutron-gamma radiation field without requiring any additional discrimination techniques such as pulse shape discrimination. [67]

Detection of fast neutrons poses a range of special problems. A directional fast-neutron detector has been developed using multiple proton recoils in separated planes of plastic scintillator material. The paths of the recoil nuclei created by neutron collision are recorded; determination of the energy and momentum of two recoil nuclei allow calculation of the direction of travel and energy of the neutron that underwent elastic scattering with them. [68]

Applications

Neutron detection is used for varying purposes. Each application has different requirements for the detection system.

Experimental neutron detection

Experiments that make use of this science include scattering experiments in which neutrons directed and then scattered from a sample are to be detected. Facilities include the ISIS neutron source at the Rutherford Appleton Laboratory, the Spallation Neutron Source at the Oak Ridge National Laboratory, and the Spallation Neutron Source (SINQ) at the Paul Scherrer Institute, in which the neutrons are produced by spallation reaction, and the traditional research reactor facilities in which neutrons are produced during fission of uranium isotopes. Noteworthy among the various neutron detection experiments is the trademark experiment of the European Muon Collaboration, first performed at CERN and now termed the "EMC experiment." The same experiment is performed today with more sophisticated equipment to obtain more definite results related to the original EMC effect.

Challenges in neutron detection in an experimental environment

Neutron detection in an experimental environment is not an easy science. The major challenges faced by modern-day neutron detection include background noise, high detection rates, neutron neutrality, and low neutron energies.

Background noise

The main components of background noise in neutron detection are high-energy photons, which aren't easily eliminated by physical barriers. The other sources of noise, such as alpha and beta particles, can be eliminated by various shielding materials, such as lead, plastic, thermo-coal, etc. Thus, photons cause major interference in neutron detection, since it is uncertain if neutrons or photons are being detected by the neutron detector. Both register similar energies after scattering into the detector from the target or ambient light, and are thus hard to distinguish. Coincidence detection can also be used to discriminate real neutron events from photons and other radiation.

High detection rates

If the detector lies in a region of high beam activity, it is hit continuously by neutrons and background noise at overwhelmingly high rates. This obfuscates collected data, since there is extreme overlap in measurement, and separate events are not easily distinguished from each other. Thus, part of the challenge lies in keeping detection rates as low as possible and in designing a detector that can keep up with the high rates to yield coherent data.

Neutrality of neutrons

Neutrons are neutral and thus do not respond to electric fields. This makes it hard to direct their course towards a detector to facilitate detection. Neutrons also do not ionize atoms except by direct collision, so gaseous ionization detectors are ineffective.

Varying behavior with energy

Detectors relying on neutron absorption are generally more sensitive to low-energy thermal neutrons, and are orders of magnitude less sensitive to high-energy neutrons. Scintillation detectors, on the other hand, have trouble registering the impacts of low-energy neutrons.

Experimental setup and method

Figure 1: The experimental setup Setup.png
Figure 1: The experimental setup

Figure 1 shows the typical main components of the setup of a neutron detection unit. In principle, the diagram shows the setup as it would be in any modern particle physics lab, but the specifics describe the setup in Jefferson Lab (Newport News, Virginia).

In this setup, the incoming particles, comprising neutrons and photons, strike the neutron detector; this is typically a scintillation detector consisting of scintillating material, a waveguide, and a photomultiplier tube (PMT), and will be connected to a data acquisition (DAQ) system to register detection details.

The detection signal from the neutron detector is connected to the scaler unit, gated delay unit, trigger unit and the oscilloscope. The scaler unit is merely used to count the number of incoming particles or events. It does so by incrementing its tally of particles every time it detects a surge in the detector signal from the zero-point. There is very little dead time in this unit, implying that no matter how fast particles are coming in, it is very unlikely for this unit to fail to count an event (e.g. incoming particle). The low dead time is due to sophisticated electronics in this unit, which take little time to recover from the relatively easy task of registering a logical high every time an event occurs. The trigger unit coordinates all the electronics of the system and gives a logical high to these units when the whole setup is ready to record an event run.

The oscilloscope registers a current pulse with every event. The pulse is merely the ionization current in the detector caused by this event plotted against time. The total energy of the incident particle can be found by integrating this current pulse with respect to time to yield the total charge deposited at the end of the PMT. This integration is carried out in the analog-digital converter (ADC). The total deposited charge is a direct measure of the energy of the ionizing particle (neutron or photon) entering the neutron detector. This signal integration technique is an established method for measuring ionization in the detector in nuclear physics. [72] The ADC has a higher dead time than the oscilloscope, which has limited memory and needs to transfer events quickly to the ADC. Thus, the ADC samples out approximately one in every 30 events from the oscilloscope for analysis. Since the typical event rate is around 106 neutrons every second, [73] this sampling will still accumulate thousands of events every second.

Separating neutrons from photons

The ADC sends its data to a DAQ unit that sorts the data in presentable form for analysis. The key to further analysis lies in the difference between the shape of the photon ionization-current pulse and that of the neutron. The photon pulse is longer at the ends (or "tails") whereas the neutron pulse is well-centered. [73] This fact can be used to identify incoming neutrons and to count the total rate of incoming neutrons. The steps leading to this separation (those that are usually performed at leading national laboratories, Jefferson Lab specifically among them) are gated pulse extraction and plotting-the-difference.

Gated pulse extraction

Ionization current signals are all pulses with a local peak in between. Using a logical AND gate in continuous time (having a stream of "1" and "0" pulses as one input and the current signal as the other), the tail portion of every current pulse signal is extracted. This gated discrimination method is used on a regular basis on liquid scintillators. [74] The gated delay unit is precisely to this end, and makes a delayed copy of the original signal in such a way that its tail section is seen alongside its main section on the oscilloscope screen.

After extracting the tail, the usual current integration is carried out on both the tail section and the complete signal. This yields two ionization values for each event, which are stored in the event table in the DAQ system.

Plotting the difference

Figure 2: Expected plot of tail energy against energy in the complete pulse plotted for all event energies. Dots represent number densities of events. Tail Energy against Total energy for Photons and Nuetrons.png
Figure 2: Expected plot of tail energy against energy in the complete pulse plotted for all event energies. Dots represent number densities of events.

In this step lies the crucial point of the analysis: the extracted ionization values are plotted. Specifically, the graph plots energy deposition in the tail against energy deposition in the entire signal for a range of neutron energies. Typically, for a given energy, there are many events with the same tail-energy value. In this case, plotted points are simply made denser with more overlapping dots on the two-dimensional plot, and can thus be used to eyeball the number of events corresponding to each energy-deposition. A considerable random fraction (1/30) of all events is plotted on the graph.

If the tail size extracted is a fixed proportion of the total pulse, then there will be two lines on the plot, having different slopes. The line with the greater slope will correspond to photon events and the line with the lesser slope to neutron events. This is precisely because the photon energy deposition current, plotted against time, leaves a longer "tail" than does the neutron deposition plot, giving the photon tail more proportion of the total energy than neutron tails.

The effectiveness of any detection analysis can be seen by its ability to accurately count and separate the number of neutrons and photons striking the detector. Also, the effectiveness of the second and third steps reveals whether event rates in the experiment are manageable. If clear plots can be obtained in the above steps, allowing for easy neutron-photon separation, the detection can be termed effective and the rates manageable. On the other hand, smudging and indistinguishability of data points will not allow for easy separation of events.

Rate control

Detection rates can be kept low in many ways. Sampling of events can be used to choose only a few events for analysis. If the rates are so high that one event cannot be distinguished from another, physical experimental parameters (shielding, detector-target distance, solid-angle, etc.) can be manipulated to give the lowest rates possible and thus distinguishable events.

Finer detection points

It is important here to observe precisely those variables that matter, since there may be false indicators along the way. For example, ionization currents might get periodic high surges, which do not imply high rates but just high energy depositions for stray events. These surges will be tabulated and viewed with cynicism if unjustifiable, especially since there is so much background noise in the setup.

One might ask how experimenters can be sure that every current pulse in the oscilloscope corresponds to exactly one event. This is true because the pulse lasts about 50  ns, allowing for a maximum of 2×107 events every second. This number is much higher than the actual typical rate, which is usually an order of magnitude less, as mentioned above. [73] This means that is it highly unlikely for there to be two particles generating one current pulse. The current pulses last 50 ns each, and start to register the next event after a gap from the previous event.

Although sometimes facilitated by higher incoming neutron energies, neutron detection is generally a difficult task, for all the reasons stated earlier. Thus, better scintillator design is also in the foreground and has been the topic of pursuit ever since the invention of scintillation detectors. Scintillation detectors were invented in 1903 by Crookes but were not very efficient until the PMT (photomultiplier tube) was developed by Curran and Baker in 1944. [72] The PMT gives a reliable and efficient method of detection since it can multiply the initial signal of a single scintillation photon hitting the PMT face millions of times into a measurable electrical pulse. Even so, scintillator detector design has room for improvement as do other options for neutron detection besides scintillation.

See also

Related Research Articles

<span class="mw-page-title-main">Geiger counter</span> Instrument used for measuring ionizing radiation

A Geiger counter is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental physics and the nuclear industry.

<span class="mw-page-title-main">Neutron</span> Subatomic particle with no charge

The neutron is a subatomic particle, symbol
n
or
n0
, which has a neutral charge, and a mass slightly greater than that of a proton. Protons and neutrons constitute the nuclei of atoms. Since protons and neutrons behave similarly within the nucleus, they are both referred to as nucleons. Nucleons have a mass of approximately one atomic mass unit, or dalton. Their properties and interactions are described by nuclear physics. Protons and neutrons are not elementary particles; each is composed of three quarks.

<span class="mw-page-title-main">Neutron activation analysis</span> Method used for determining the concentrations of elements in many materials

Neutron activation analysis (NAA) is a nuclear process used for determining the concentrations of elements in many materials. NAA allows discrete sampling of elements as it disregards the chemical form of a sample, and focuses solely on atomic nuclei. The method is based on neutron activation and thus requires a neutron source. The sample is bombarded with neutrons, causing its constituent elements to form radioactive isotopes. The radioactive emissions and radioactive decay paths for each element have long been studied and determined. Using this information, it is possible to study spectra of the emissions of the radioactive sample, and determine the concentrations of the various elements within it. A particular advantage of this technique is that it does not destroy the sample, and thus has been used for the analysis of works of art and historical artifacts. NAA can also be used to determine the activity of a radioactive sample.

<span class="mw-page-title-main">Geiger–Müller tube</span> Part of a Geiger counter

The Geiger–Müller tube or G–M tube is the sensing element of the Geiger counter instrument used for the detection of ionizing radiation. It is named after Hans Geiger, who invented the principle in 1908, and Walther Müller, who collaborated with Geiger in developing the technique further in 1928 to produce a practical tube that could detect a number of different radiation types.

<span class="mw-page-title-main">Scintillation counter</span> Instrument for measuring ionizing radiation

A scintillation counter is an instrument for detecting and measuring ionizing radiation by using the excitation effect of incident radiation on a scintillating material, and detecting the resultant light pulses.

<span class="mw-page-title-main">Scintillator</span> Material which glows when excited by ionizing radiation

A scintillator is a material that exhibits scintillation, the property of luminescence, when excited by ionizing radiation. Luminescent materials, when struck by an incoming particle, absorb its energy and scintillate. Sometimes, the excited state is metastable, so the relaxation back down from the excited state to lower states is delayed. The process then corresponds to one of two phenomena: delayed fluorescence or phosphorescence. The correspondence depends on the type of transition and hence the wavelength of the emitted optical photon.

In experimental and applied particle physics, nuclear physics, and nuclear engineering, a particle detector, also known as a radiation detector, is a device used to detect, track, and/or identify ionizing particles, such as those produced by nuclear decay, cosmic radiation, or reactions in a particle accelerator. Detectors can measure the particle energy and other attributes such as momentum, spin, charge, particle type, in addition to merely registering the presence of the particle.

A semiconductor detector in ionizing radiation detection physics is a device that uses a semiconductor to measure the effect of incident charged particles or photons.

In condensed matter physics, scintillation is the physical process where a material, called a scintillator, emits ultraviolet or visible light under excitation from high energy photons or energetic particles. See scintillator and scintillation counter for practical applications.

<span class="mw-page-title-main">Photodetector</span> Sensors of light or other electromagnetic energy

Photodetectors, also called photosensors, are sensors of light or other electromagnetic radiation. There are a wide variety of photodetectors which may be classified by mechanism of detection, such as photoelectric or photochemical effects, or by various performance metrics, such as spectral response. Semiconductor-based photodetectors typically use a p–n junction that converts photons into charge. The absorbed photons make electron–hole pairs in the depletion region. Photodiodes and photo transistors are a few examples of photo detectors. Solar cells convert some of the light energy absorbed into electrical energy.

<span class="mw-page-title-main">Gamma spectroscopy</span> Quantitative study of the energy spectra of gamma-ray sources

Gamma-ray spectroscopy is the qualitative study of the energy spectra of gamma-ray sources, such as in the nuclear industry, geochemical investigation, and astrophysics. Gamma-ray spectrometry, on the other hand, is the method used to acquire a quantitative spectrum measurement.

Cadmium tungstate (CdWO4 or CWO), the cadmium salt of tungstic acid, is a dense, chemically inert solid which is used as a scintillation crystal to detect gamma rays. It has density of 7.9 g/cm3 and melting point of 1325 °C. It is toxic if inhaled or swallowed. Its crystals are transparent, colorless, with slight yellow tint. It is odorless. Its CAS number is 7790-85-4. It is not hygroscopic.

<span class="mw-page-title-main">DEAP</span> Dark matter search experiment

DEAP is a direct dark matter search experiment which uses liquid argon as a target material. DEAP utilizes background discrimination based on the characteristic scintillation pulse-shape of argon. A first-generation detector (DEAP-1) with a 7 kg target mass was operated at Queen's University to test the performance of pulse-shape discrimination at low recoil energies in liquid argon. DEAP-1 was then moved to SNOLAB, 2 km below Earth's surface, in October 2007 and collected data into 2011.

<span class="mw-page-title-main">Cargo scanning</span>

Cargo scanning or non-intrusive inspection (NII) refers to non-destructive methods of inspecting and identifying goods in transportation systems. It is often used for scanning of intermodal freight shipping containers. In the US it is spearheaded by the Department of Homeland Security and its Container Security Initiative (CSI) trying to achieve one hundred percent cargo scanning by 2012 as required by the US Congress and recommended by the 9/11 Commission. In the US the main purpose of scanning is to detect special nuclear materials (SNMs), with the added bonus of detecting other types of suspicious cargo. In other countries the emphasis is on manifest verification, tariff collection and the identification of contraband. In February 2009, approximately 80% of US incoming containers were scanned. To bring that number to 100% researchers are evaluating numerous technologies, described in the following sections.

A Visible Light Photon Counter (VLPC) is a photon counting photodetector based on impurity-band conduction in arsenic-doped silicon. They have high quantum efficiency and are able to detect single photons in the visible range of the electromagnetic spectrum. The ability to count the exact number of photons detected is extremely important for quantum key distribution.

Nuclear MASINT is one of the six major subdisciplines generally accepted to make up Measurement and Signature Intelligence (MASINT), which covers measurement and characterization of information derived from nuclear radiation and other physical phenomena associated with nuclear weapons, reactors, processes, materials, devices, and facilities. Nuclear monitoring can be done remotely or during onsite inspections of nuclear facilities. Data exploitation results in characterization of nuclear weapons, reactors, and materials. A number of systems detect and monitor the world for nuclear explosions, as well as nuclear materials production.

<span class="mw-page-title-main">Neutron imaging</span>

Neutron imaging is the process of making an image with neutrons. The resulting image is based on the neutron attenuation properties of the imaged object. The resulting images have much in common with industrial X-ray images, but since the image is based on neutron attenuating properties instead of X-ray attenuation properties, some things easily visible with neutron imaging may be very challenging or impossible to see with X-ray imaging techniques.

Nuclear forensics is the investigation of nuclear materials to find evidence for the source, the trafficking, and the enrichment of the material. The material can be recovered from various sources including dust from the vicinity of a nuclear facility, or from the radioactive debris following a nuclear explosion.

<span class="mw-page-title-main">LZ experiment</span> Experiment in South Dakota, United States

The LUX-ZEPLIN (LZ) Experiment is a next-generation dark matter direct detection experiment hoping to observe weakly interacting massive particles (WIMP) scatters on nuclei. It was formed in 2012 by combining the LUX and ZEPLIN groups. It is currently a collaboration of 30 institutes in the US, UK, Portugal and South Korea. The experiment is located at the Sanford Underground Research Facility (SURF) in South Dakota, and is managed by the United States Department of Energy's (DOE) Lawrence Berkeley National Lab.

<span class="mw-page-title-main">Radionuclide identification device</span>

A radionuclide identification device is a small, lightweight, portable gamma-ray spectrometer used for the detection and identification of radioactive substances. As RIIDs are portable, they are suitable for medical and industrial applications, fieldwork, geological surveys, first-line responders in Homeland Security, and Environmental Monitoring and Radiological Mapping along with other industries that necessitate the identification of radioactive substances..

References

  1. 1 2 Particle Data Group's Review of Particle Physics 2006
  2. Particle Data Group Summary Data Table on Baryons
  3. 1 2 3 4 Tsoulfanidis, Nicholas (1995). Measurement and Detection of Radiation (2nd ed.). Washington, D.C.: Taylor & Francis. pp.  467–501. ISBN   978-1-56032-317-4.
  4. Materials with a high hydrogen content such as water or plastic
  5. Boron Trifluoride (BF3) Neutron Detectors
  6. Yousuke, I.; Daiki, S.; Hirohiko, K.; Nobuhiro, S.; Kenji, I. (2000). "Deterioration of pulse-shape discrimination in liquid organic scintillator at high energies". 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149). Vol. 1. IEEE. pp. 6/219–6/221. doi:10.1109/NSSMIC.2000.949173. ISBN   978-0-7803-6503-2. S2CID   119538680.
  7. Kawaguchi, N.; Yanagida, T.; Yokota, Y.; Watanabe, K.; Kamada, K.; Fukuda, K.; Suyama, T.; Yoshikawa, A. (2009). "Study of crystal growth and scintillation properties as a neutron detector of 2-inch diameter eu doped LiCaAlF6 single crystal". 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC). IEEE. pp. 1493–1495. doi:10.1109/NSSMIC.2009.5402299. ISBN   978-1-4244-3961-4. S2CID   5807137.
  8. Example crystal scintillator based neutron monitor.
  9. Bollinger, L. M.; Thomas, G. E.; Ginther, R. J. (1962). "Neutron Detection With Glass Scintillators". Nuclear Instruments and Methods. 17 (1): 97–116. Bibcode:1962NucIM..17...97B. doi:10.1016/0029-554X(62)90178-7.
  10. Miyanaga, N.; Ohba, N.; Fujimoto, K. (1997). "Fiber scintillator/streak camera detector for burn history measurement in inertial confinement fusion experiment". Review of Scientific Instruments. 68 (1): 621–623. Bibcode:1997RScI...68..621M. doi:10.1063/1.1147667.
  11. Egelstaff, P. A.; et al. (1957). "Glass Scintillators For Prompt Detection Of Intermediate Energy Neutrons". Nuclear Instruments and Methods. 1 (4): 197–199. Bibcode:1957NucIn...1..197E. doi:10.1016/0369-643x(57)90042-7.
  12. Bollinger, L. M.; Thomas, G. E.; Ginther, R. J. (1962). "Neutron Detection With Glass Scintillators". Nuclear Instruments and Methods. 17 (1): 97–116. Bibcode:1962NucIM..17...97B. doi:10.1016/0029-554X(62)90178-7.
  13. Spowart, A. R. (1976). "Neutron Scintillating Glasses .1. Activation By External Charged-Particles And Thermal-Neutrons". Nuclear Instruments and Methods. 135 (3): 441–453. Bibcode:1976NucIM.135..441S. doi:10.1016/0029-554X(76)90057-4.
  14. Atkinson, M.; Fent J.; Fisher C.; et al. (1987). "Initial Tests Of A High-Resolution Scintillating Fiber (Scifi) Tracker". Nuclear Instruments and Methods in Physics Research A. 254 (3): 500–514. Bibcode:1987NIMPA.254..500A. doi:10.1016/0168-9002(87)90022-2.
  15. Bliss, M.; Brodzinski R. L.; Craig R. A.; Geelhood B. D.; Knopf M. A.; Miley H. S.; Perkins R. W.; Reeder P. L.; Sunberg D. S.; Warner R. A.; Wogman N. A. (1995). Johnson, C. Bruce; Fenyves, Ervin J (eds.). "Glass-fiber-based neutron detectors for high- and low-flux environments". Proc. SPIE. Photoelectronic Detectors, Cameras, and Systems. 2551: 108. Bibcode:1995SPIE.2551..108B. doi:10.1117/12.218622. S2CID   137395702.[ permanent dead link ]
  16. Abel, K. H.; Arthur R. J.; Bliss M.; Brite D. W.; et al. (1993). "Performance and Applications of Scintillating-Glass-Fiber Neutron Sensors". Proceedings of the SCIFI 93 Workshop on Scintillating Fiber Detectors: 463–472.
  17. Abel, K. H.; Arthur R. J.; Bliss M.; Brite D. W.; et al. (1994). "Scintillating Glass Fiber-Optic Neutron Sensors". MRS Proceedings. 348: 203–208. Bibcode:1994mrs..meetR...4A. doi:10.1557/PROC-348-203.
  18. Bliss, M.; Craig R. A.; Reeder P. L. (1994). "The Physics and Structure-property Relationships of Scintillator Materials: Effect of Thermal History and Chemistry on the Light Output of Scintillating Glasses". Nuclear Instruments and Methods in Physics Research A. 342 (2–3): 357–393. Bibcode:1994NIMPA.342..357B. doi:10.1016/0168-9002(94)90263-1.
  19. Bliss, M.; Craig R. A.; Reeder P. L.; Sunberg D. S.; Weber M. J. (1994). "Relationship Between Microstructure and Efficiency of Scintillating Glasses". MRS Proceedings. 348: 195–202. doi:10.1557/PROC-348-195.
  20. Seymour, R.; Crawford, T.; et al. (2001). "Portal, freight and vehicle monitor performance using scintillating glass fiber detectors for the detection of plutonium in the Illicit Trafficking Radiation Assessment Program". Journal of Radioanalytical and Nuclear Chemistry. 248 (3): 699–705. doi:10.1023/A:1010692712292. S2CID   94473173.
  21. Seymour, R. S.; Craig R. A.; Bliss M.; Richardson B.; Hull C. D.; Barnett D. S. (1998). Robertson, David E. (ed.). "Performance of a neutron-sensitive scintillating glass-fiber panel for portal, freight and vehicle monitoring". Proc. SPIE. Nuclear Waste Instrumentation Engineering. 3536: 148–155. doi:10.1117/12.339067. S2CID   137600990.[ permanent dead link ]
  22. Seymour, R. S.; Richardson B.; Morichi M.; Bliss M.; Craig R. A.; Sunberg D. S. (2000). "Scintillating-glass-fiber neutron sensors, their application and performance for plutonium detection and monitoring". Journal of Radioanalytical and Nuclear Chemistry. 243 (2): 387–388. doi:10.1023/A:1016009726996. S2CID   94700090.
  23. Nucsafe Inc. website
  24. 1 2 Van Ginhoven, R. M.; Kouzes R. T.; Stephens D. L. (2009). "Alternative Neutron Detector Technologies for Homeland Security PIET-43741-TM-840 PNNL-18471".{{cite journal}}: Cite journal requires |journal= (help)
  25. Yanagida, T.; et al. (2011). "Europium and Sodium Codoped LiCaAlF6 Scintillator for Neutron Detection". Applied Physics Express. 4 (10): 106401. Bibcode:2011APExp...4j6401Y. doi:10.1143/apex.4.106401. S2CID   94408433.
  26. Kole, M.; et al. (2013). "A Balloon-borne Measurement of High Latitude Atmospheric Neutrons Using a LiCAF Neutron Detector". Nuclear Science Symposium Conference Record. arXiv: 1311.5531 . Bibcode:2013arXiv1311.5531K.
  27. Iwanowska, J.; et al. (2011). "Thermal neutron detection with Ce3+ doped LiCaAlF6 single crystals". Nuclear Instruments and Methods in Physics Research A. 652 (1): 319–322. Bibcode:2011NIMPA.652..319I. doi:10.1016/j.nima.2010.09.182.
  28. Large Format Li Co-doped NaI:Tl Scintilation Detector for Gamma-ray and Neutron Dual Detection, 2017 Technical Paper.
  29. Li co-doped NaI:Tl (NaIL) − A Large Volume Neutron-Gamma Scintillator with Exceptional Pulse Shape Discrimination 2017 IEEE Presentation.
  30. Example Gamma-Neutron Dual detector.
  31. Caruso, A.N. (2010). "The Physics of Solid-State Neutron Detector Materials and Geometries". J. Phys.: Condens. Matter. 22 (44): 443201 (32 pp). doi:10.1088/0953-8984/22/44/443201. PMID   21403341. S2CID   1841640.
  32. Rose, A. (1967). "Sputtered Boron Films on Silicon Surface Barrier Detectors". Nuclear Instruments and Methods. 52 (1): 166–170. Bibcode:1967NucIM..52..166R. doi:10.1016/0029-554X(67)90576-9.
  33. Popisil, S.; Sopko, B.; Havrankova, E.; Janout, Z.; Konicek, J.; Macha, I.; Pavlu, J. (1993). "Si Diode as a Small Detector of Slow Neutrons". Radiation Protection Dosimetry. 46: 115–118.
  34. Babcock, R.V.; Davis, R.E.; Ruby, S.L.; Sun, K.H.; Wolley, E.D. (1959). "Coated Semiconductor is Tiny Neutron Detector". Nucleonics. 17: 116–122.
  35. McGregor, D.S.; Hammig, M.D.; Yang Y-H.; Gersch, H.K.; Klann, R.T. (2003). "Design Considerations for Thin Film Coated Semiconductor Thermal Neutron Detectors – I: Basics Regarding Alpha Particle Emitting Neutron Reactive Films". Nuclear Instruments and Methods A. 500 (1–3): 272–308. Bibcode:2003NIMPA.500..272M. doi:10.1016/S0168-9002(02)02078-8.
  36. Rauch, H.; Grass, F.; Feigl, B. (1967). "Ein Neuartiger Detektor fur Langsame Neutronen". Nuclear Instruments and Methods. 46 (1): 153–156. Bibcode:1967NucIM..46..153R. doi:10.1016/0029-554X(67)90408-9.
  37. Feigl, B.; Rauch, H. (1968). "Der Gd-neutronenzahler". Nuclear Instruments and Methods. 61 (3): 349–356. Bibcode:1968NucIM..61..349F. doi:10.1016/0029-554X(68)90250-4.
  38. McGregor, D.S.; Klann, R.T.; Sanders, J.D.; Lindsay, J.T.; Linden, K.J.; Gersch, H.K.; De Lurgio, P.M.; Fink, C.L.; Ariesanti, E. (2002). James, Ralph B; Franks, Larry A; Burger, Arnold; Westbrook, Edwin M; Durst, Roger D (eds.). "Recent Results From Thin-Film-Coated Semiconductor Neutron Detectors". Proc. SPIE. X-Ray and Gamma-Ray Detectors and Applications IV. 4784: 164–182. CiteSeerX   10.1.1.510.5968 . doi:10.1117/12.455697. S2CID   14303554.
  39. McGregor, D.S.; Bellinger, S.L.; Shultis, J.K. (2013). "Present Status of Microstructured Semiconductor Neutron Detectors" (PDF). J. Cryst. Growth. 379: 99–110. Bibcode:2013JCrGr.379...99M. doi:10.1016/j.jcrysgro.2012.10.061. hdl: 2097/16983 .
  40. McGregor, D.S.; Bellinger, S.L.; Fronk, R.G.; Henson, L.C.; Huddleston, D.E.; Ochs, T.R.; Shultis, J.K.; Sobering, T.J.; Taylor, R.D. (2015). "Development of Compact High Efficiency Microstructured Semiconductor Neutron Detectors". Rad. Phys. Chem. 116: 32–37. Bibcode:2015RaPC..116...32M. doi: 10.1016/j.radphyschem.2015.05.025 .
  41. Muminov, R.A.; Tsvang, L.D. (1987). "High-Efficiency Semiconductor Thermal-Neutron Detectors". Soviet Atomic Energy. 62 (4): 316–319. doi:10.1007/BF01123372. S2CID   119511403.
  42. Schelten, J.; Balzhauser, M.; Hongesberg, F.; Engels, R.; Reinartz, R. (1997). "A New Neutron Detector Development Based on Silicon Semiconductor and 6LiF Converter". Physica B: Condensed Matter. 234–236: 1084–1086. Bibcode:1997PhyB..234.1084S. doi:10.1016/S0921-4526(97)00024-0.
  43. McGregor, D.S.; Klann, R.T.; Gersch, H.K.; Ariesanti, E.; Sanders, J.D.; Van Der Elzen, B. (2001). "New Surface Morphology for Low Stress Thin-Film-Coated Thermal Neutron Detectors". IEEE Nucl Sci. Symp. Conf. Rec., San Diego, California, Nov. 4-9. 49 (4): 1999. Bibcode:2002ITNS...49.1999M. doi:10.1109/TNS.2002.801697.
  44. McGregor, D.S.; Klann, R.T.; Gersch, H.K.; Ariesanti, E.; Sanders, J.D.; Van Der Elzen, B. (2002). "New Surface Morphology for Low Stress Thin-Film-Coated Thermal Neutron Detectors". IEEE Transactions on Nuclear Science. 49 (4): 1999–2004. Bibcode:2002ITNS...49.1999M. doi:10.1109/TNS.2002.801697.
  45. Fronk, R.G.; Bellinger, S.L.; Henson, L.C.; Huddleston, D.E.; Ochs, T.R.; Sobering, T.J.; McGregor, D.S. (2015). "High-Efficiency Microstructured Semiconductor Neutron Detectors for Direct Helium-3 Replacement". Nucl. Instrum. Methods A. 779: 25–32. doi:10.1016/j.nima.2015.01.041.
  46. Uher, J.; Jakubek, J.; Kenney, C.; Kohout, Z.; Linhart, V.; Parker, S.; Petersson, S.; Pospisil, S.; Thungstrom, G. (2007). "Characterization of 3D Thermal Neutron Semiconductor Detectors". Nucl. Instrum. Methods A. 576 (1): 32–37. Bibcode:2007NIMPA.576...32U. doi:10.1016/j.nima.2007.01.115.
  47. Nikolic, R.J.; Conway, A.M.; Reinhart, C.E.; Graff, R.T.; Wang, T.F. (2008). "6:1 Aspect Ratio Silicon Pillar Based Thermal Neutron Detector Filled with 10B". Appl. Phys. Lett. 93 (13): 133502 (3 pages). Bibcode:2008ApPhL..93m3502N. doi:10.1063/1.2985817.
  48. RDT, Inc. website
  49. Ochs, T.R.; Bellinger, S.L.; Fronk, R.G.; Henson, L.C.; Huddleston, D.E.; Lyric, Z.I.; Shultis, J.K.; Smith C.T.; Sobering, T.J.; McGregor, D.S. (2017). "Present Status of the Microstructured Semiconductor Neutron Detector-Based Direct Helium-3 Replacement". IEEE Trans. Nucl. Sci. 64 (7): 1846–1850. Bibcode:2017ITNS...64.1846O. doi:10.1109/TNS.2017.2653719. S2CID   38524621.
  50. Ananthanarayanan, K.P.; Gielisse, P.J.; Choudry, A. (1974). "Boron Compounds for Thermal Neutron Detection". Nucl. Instrum. Methods. 118 (1): 45–48. Bibcode:1974NucIM.118...45A. doi:10.1016/0029-554X(74)90683-1.
  51. Kumashiro, Y.; Okada, Y.; Misawa, S.; Koshiro, T. (1987). "The Preparation of 10BP Single Crystals". Proc. Tenth International Conference Chemical Vapor Deposition. 87–88: 813–818.
  52. Emin, D.; Aselage, T.L. (2005). "A Proposed Boron-Carbide-Based Solid-State Neutron Detector". J. Appl. Phys. 97 (1): 013529–013529–3. Bibcode:2005JAP....97a3529E. doi:10.1063/1.1823579.
  53. Caruso, A.N.; Dowben, P.A.; Balkir, N.; Schemm, N.; Osberg, K.; Fairchild, R.W.; Flores, O.B.; Balaz, S.; Harken, A.D.; Robertson, B.W.; Brand, J.I. (2006). "The All Boron Carbide Diode Neutron Detector: Comparison and Theory". Mater. Sci. Eng. B. 135 (2): 129–133. doi:10.1016/j.mseb.2006.08.049.
  54. McGregor, D.S.; Unruh, T.; McNeil, W.J. (2008). "Thermal Neutron Detection with Pyrolytic Boron Nitride". Nucl. Instrum. Methods A. 591 (3): 530–533. Bibcode:2008NIMPA.591..530M. doi:10.1016/j.nima.2008.03.002.
  55. Doan, T.C.; Majety, S.; Grenadier, S.; Li, J.; Lin, J.Y.; Jiang, H.X. (2015). "Hexagonal Boron Nitride Thin Film Thermal Neutron Detectors with High Energy Resolution of the Reaction Products". Nucl. Instrum. Methods A. 783: 121–127. Bibcode:2015NIMPA.783..121D. doi:10.1016/j.nima.2015.02.045.
  56. Domnich, V.; Reynaud, S.; Haber, R.A.; Chowalla, M. (2011). "Boron Carbide: Structure, Properties, and Stability Under Stress". J. Am. Ceram. Soc. 94 (11): 3605–3628. doi:10.1111/j.1551-2916.2011.04865.x.
  57. Montag, B.W.; Reichenberger, M.A.; Edwards, N.; Ugorwoski, P.B.; Sunder, M.; Weeks, J.; McGregor, D.S. (2016). "Device Fabrication, Characterization, and Thermal Neutron Detection Response of LiZnP and LiZnAs Semiconducting Devices". Nucl. Instrum. Methods A. 836: 30–36. Bibcode:2016NIMPA.836...30M. doi: 10.1016/j.nima.2016.08.037 .
  58. Vradii, A.G.; Krapivin, M.I.; Maslova, L.V.; Matveev, O.A.; Khusainov, A.Kh.; Shashurin, V.K. (1977). "Possibilities of Recording Thermal Neutrons with Cadmium Telluride Detectors". Sov. Atomic Energy. 42: 64–66. doi:10.1007/BF01119710. S2CID   95935837.
  59. McGregor, D.S.; Lindsay, J.T.; Olsen, R.W. (1996). "Thermal Neutron Detection with Cadmium1−xZincxTelluride Semiconductor Detectors". Nucl. Instrum. Methods A. 381 (2–3): 498–501. Bibcode:1996NIMPA.381..498M. doi:10.1016/S0168-9002(96)00580-3.
  60. Beyerle, A.G.; Hull, K.L. (1987). "Neutron Detection with Mercuric Iodide Detectors". Nucl. Instrum. Methods A. 256 (2): 377–380. Bibcode:1987NIMPA.256..377B. doi:10.1016/0168-9002(87)90236-1.
  61. Bell, Z.W.; Pohl, K.R.; Van Den Berg, L. (2004). "Neutron Detection with Mercuric Iodide". IEEE Trans. Nucl. Sci. 51 (3): 1163–1165. Bibcode:2004ITNS...51.1163B. doi:10.1109/TNS.2004.829651. OSTI   812511. S2CID   62773581.
  62. van Eijk, C. W. E.; de Haas, J. T. M.; Dorenbos, P.; Kramer, K. W.; Gudel, H. U. (2005). "Development of Elpasolite and Monoclinic Thermal Neutron Scintillators". IEEE Nuclear Science Symposium Conference Record, 2005. Vol. 1. IEEE. pp. 239–243. doi:10.1109/NSSMIC.2005.1596245. ISBN   978-0-7803-9221-2. S2CID   44200145.
  63. Stromswold, D.C.; AJ Peurrung; RR Hansen; PL Reeder (1999). "Direct Fast-Neutron Detection. PNNL-13068, Pacific Northwest National Laboratory, Richland, WA".{{cite journal}}: Cite journal requires |journal= (help)
  64. Pozzi, S. A.; J. L. Dolan; E. C. Miller; M. Flaska; S. D. Clarke; A. Enqvist; P. Peerani; M. A. Smith-Nelson; E. Padovani; J. B. Czirr; L. B. Rees (2011). "Evaluation of New and Existing Organic Scintillators for Fast Neutron Detection". Proceedings of the Institute of Nuclear Materials Management 52nd Annual Meeting on CD-ROM, Palm Desert, California, USA. July 17 – 22.
  65. Lewis, J.M.; R. P. Kelley; D. Murer; K. A. Jordan (2014). "Fission signal detection using helium-4 gas fast neutron scintillation detectors". Appl. Phys. Lett. 105 (1): 014102. Bibcode:2014ApPhL.105a4102L. doi:10.1063/1.4887366.
  66. Ghosh, P.; W. Fu; M. J. Harrison; P. K. Doyle; N. S. Edwards; J. A. Roberts; D. S. McGregor (2018). "A high-efficiency, low-Ĉerenkov Micro-Layered Fast-Neutron Detector for the TREAT hodoscope". Nuclear Instruments and Methods in Physics Research Section A. 904: 100–106. Bibcode:2018NIMPA.904..100G. doi: 10.1016/j.nima.2018.07.035 . S2CID   126130994.
  67. Ghosh, P.; D. M. Nichols; W. Fu; J. A. Roberts; D. S. McGregor (2019). "Gamma-Ray Rejection of the SiPM-coupled Micro-Layered Fast-Neutron Detector". 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC). pp. 1–3. doi:10.1109/NSS/MIC42101.2019.9059869. ISBN   978-1-7281-4164-0. S2CID   204877955.
  68. Vanier, P. E.; Forman, L.; Dioszegi, I.; Salwen, C.; Ghosh, V. J. (2007). "Calibration and testing of a large-area fast-neutron directional detector". 2007 IEEE Nuclear Science Symposium Conference Record. IEEE. pp. 179–184. doi:10.1109/NSSMIC.2007.4436312. ISBN   978-1-4244-0922-8. S2CID   26211444.
  69. Frenje, J. (1996), "The MPR Neutron Diagnostic at Jet — an ITER Prototype Study", Diagnostics for Experimental Thermonuclear Fusion Reactors, Springer US, pp. 417–420, doi:10.1007/978-1-4613-0369-5_49, ISBN   9781461380207
  70. Hutchinson, I. H. (2002). Principles of plasma diagnostics (2nd ed.). Cambridge: Cambridge University Press. ISBN   0521803896. OCLC   50124576.
  71. John F. Beacom & Mark R. Vagins (2004). "Antineutrino Spectroscopy with Large Water Čerenkov Detectors". Physical Review Letters . 93 (17): 171101. arXiv: hep-ph/0309300 . Bibcode:2004PhRvL..93q1101B. doi:10.1103/PhysRevLett.93.171101. PMID   15525063. S2CID   10472028.
  72. 1 2 Leo, W. R. (1994). Techniques for Nuclear and Particle Physics Experiments. Springer.
  73. 1 2 3 Cerny, J. C., Dolemal, Z., Ivanov, M. P., Kuzmin, E. P., Svejda, J., Wilhelm, I. (2003). "Study of neutron response and n–γ discrimination by charge comparison method for small liquid scintillation detector". Nuclear Instruments and Methods in Physics Research A . 527 (3): 512–518. arXiv: nucl-ex/0311022 . Bibcode:2004NIMPA.527..512C. doi:10.1016/j.nima.2004.03.179.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  74. Jastaniah, S. D., Sellin, P. J. (2003). "Digital techniques for n–γ pulse shape discrimination capture-gated neutron spectroscopy using liquid". Nuclear Instruments and Methods in Physics Research A . 517 (1–3): 202–210. Bibcode:2004NIMPA.517..202J. doi:10.1016/j.nima.2003.08.178.{{cite journal}}: CS1 maint: multiple names: authors list (link)

Further reading