Argentometry

Last updated

In analytical chemistry, argentometry is a type of titration involving the silver(I) ion. Typically, it is used to determine the amount of chloride present in a sample. The sample solution is titrated against a solution of silver nitrate of known concentration. Chloride ions react with silver(I) ions to give the insoluble silver chloride:

Contents

Ag+ (aq) + Cl (aq) → AgCl (s) (K = 5.88 × 109)

Volhard method

An example of back titration, the Volhard method, named after Jacob Volhard, involves the addition of excess silver nitrate to the analyte; the silver chloride is filtered, and the remaining silver nitrate is titrated against ammonium thiocyanate, [1] with ferric ammonium sulfate as an indicator which forms blood-red [Fe(OH2)5(SCN)]2+ at the end point:

Ag+ (aq) + SCN (aq) → AgSCN (s) (Ksp = 1.16 × 1012)
Fe(OH)(OH2)2+
5
(aq) + SCN (aq)→ [Fe(OH2)5(SCN)]2+ + OH

Mohr method

Determining chlorides in water by the Mohr method. Potassium chromate is added as indicator in an Erlenmeyer flask and the end of the reaction is determined by the slight red color given by the silver chromate. Opredeluvanje na khloridi vo voda spored Moroviot metod (1).jpg
Determining chlorides in water by the Mohr method. Potassium chromate is added as indicator in an Erlenmeyer flask and the end of the reaction is determined by the slight red color given by the silver chromate.

In the Mohr method, named after Karl Friedrich Mohr, potassium chromate is an indicator, giving red silver chromate after all chloride ions have reacted:

2Ag+ (aq) + CrO2−
4
(aq) → Ag2CrO4 (s) (Ksp = 1.1 × 1012)

The solution needs to be near neutral, because silver hydroxide forms at high pH, while the chromate forms Ag2Cr2O7 at low pH, reducing the concentration of chromate ions, and delaying the formation of the precipitate. Carbonates and phosphates precipitate with silver, and need to be absent to prevent inaccurate results.

The Mohr method may be adapted to determine the total chlorine content of a sample by igniting the sample with calcium, then ferric acetate. Calcium acetate "fixes" free chlorine, precipitates carbonates, and neutralizes the resultant solution. Ferric acetate removes phosphates. All chlorides are dissolved out of the residue, and titrated. [1]

Fajans method

In the Fajans method, named after Kazimierz Fajans, typically dichlorofluorescein is used as an indicator; the end-point is marked by the green suspension turning pink. Prior to the end-point of the titration, chloride ions remain in excess. They adsorb on the AgCl surface, imparting a negative charge to the particles. Past the equivalence point, excess silver(I) ions adsorb on the AgCl surface, imparting a positive charge. Anionic dyes such as dichlorofluorescein are attracted to the particles, and undergo a colour change upon adsorption, representing the end-point. Eosin (tetrabromofluorescein) is suitable for titrating against bromide, iodide, and thiocyanate anions, giving a sharper end-point than dichlorofluorescein. It is not suitable for titrating against chloride anions because it binds to AgCl more strongly than chloride does. [2]

See also

Related Research Articles

In chemistry, a salt is a chemical compound consisting of an ionic assembly of positively charged cations and negatively charged anions, which results in a compound with no net electric charge. A common example is table salt, with positively charged sodium ions and negatively charged chloride ions.

Titration Laboratory method for determining the concentration of an analyte

Titration is a common laboratory method of quantitative chemical analysis to determine the concentration of an identified analyte. A reagent, termed the titrant or titrator, is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.

Solubility equilibrium is a type of dynamic equilibrium that exists when a chemical compound in the solid state is in chemical equilibrium with a solution of that compound. The solid may dissolve unchanged, with dissociation, or with chemical reaction with another constituent of the solution, such as acid or alkali. Each solubility equilibrium is characterized by a temperature-dependent solubility product which functions like an equilibrium constant. Solubility equilibria are important in pharmaceutical, environmental and many other scenarios.

Sodium hypochlorite Chemical compound

Sodium hypochlorite is a chemical compound with the formula NaOCl or NaClO, comprising a sodium cation and a hypochlorite anion. It may also be viewed as the sodium salt of hypochlorous acid. The anhydrous compound is unstable and may decompose explosively. It can be crystallized as a pentahydrate NaOCl·5H
2
O
, a pale greenish-yellow solid which is not explosive and is stable if kept refrigerated.

Silver nitrate Chemical compound

Silver nitrate is an inorganic compound with chemical formula AgNO
3
. This salt is a versatile precursor to many other silver compounds, such as those used in photography. It is far less sensitive to light than the halides. It was once called lunar caustic because silver was called luna by ancient alchemists who associated silver with the moon. In solid silver nitrate, the silver ions are three-coordinated in a trigonal planar arrangement.

A halide is a binary phase, of which one part is a halogen atom and the other part is an element or radical that is less electronegative than the halogen, to make a, e.g., fluoride, chloride, or theoretically tennesside compound. The alkali metals combine directly with halogens under appropriate conditions forming halides of the general formula, MX. Many salts are halides; the hal- syllable in halide and halite reflects this correlation. All Group 1 metals form halides that are white solids at room temperature.

The common-ion effect refers to the decrease in solubility of an ionic precipitate by the addition to the solution of a soluble compound with an ion in common with the precipitate. This behaviour is a consequence of Le Chatelier's principle for the equilibrium reaction of the ionic association/dissociation. The effect is commonly seen as an effect on the solubility of salts and other weak electrolytes. Adding an additional amount of one of the ions of the salt generally leads to increased precipitation of the salt, which reduces the concentration of both ions of the salt until the solubility equilibrium is reached. The effect is based on the fact that both the original salt and the other added chemical have one ion in common with each other.

Gravimetric analysis Quantitative determination of a chemical species based on its mass

Gravimetric analysis describes a set of methods used in analytical chemistry for the quantitative determination of an analyte based on its mass. The principle of this type of analysis is that once an ion's mass has been determined as a unique compound, that known measurement can then be used to determine the same analyte's mass in a mixture, as long as the relative quantities of the other constituents are known.

A silver halide is one of the chemical compounds that can form between the element silver (Ag) and one of the halogens. In particular, bromine (Br), chlorine (Cl), iodine (I) and fluorine (F) may each combine with silver to produce silver bromide (AgBr), silver chloride (AgCl), silver iodide (AgI), and three forms of silver fluoride, respectively.

Silver chloride Chemical compound with the formula AgCl

Silver chloride is a chemical compound with the chemical formula AgCl. This white crystalline solid is well known for its low solubility in water (this behavior being reminiscent of the chlorides of Tl+ and Pb2+). Upon illumination or heating, silver chloride converts to silver (and chlorine), which is signaled by grey to black or purplish coloration to some samples. AgCl occurs naturally as a mineral chlorargyrite.

Lead(II) chloride Chemical compound

Lead(II) chloride (PbCl2) is an inorganic compound which is a white solid under ambient conditions. It is poorly soluble in water. Lead(II) chloride is one of the most important lead-based reagents. It also occurs naturally in the form of the mineral cotunnite.

Classical qualitative inorganic analysis is a method of analytical chemistry which seeks to find the elemental composition of inorganic compounds. It is mainly focused on detecting ions in an aqueous solution, therefore materials in other forms may need to be brought to this state before using standard methods. The solution is then treated with various reagents to test for reactions characteristic of certain ions, which may cause color change, precipitation and other visible changes.

The equivalence point, or stoichiometric point, of a chemical reaction is the point at which chemically equivalent quantities of reactants have been mixed. For an acid-base reaction the equivalence point is where the moles of acid and the moles of base would neutralize each other according to the chemical reaction. This does not necessarily imply a 1:1 molar ratio of acid:base, merely that the ratio is the same as in the chemical reaction. It can be found by means of an indicator, for example phenolphthalein or methyl orange.

Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary iodine indicates the end point.

A salt metathesis reaction, sometimes called a double displacement reaction, is a chemical process involving the exchange of bonds between two reacting chemical species which results in the creation of products with similar or identical bonding affiliations. This reaction is represented by the general scheme:

Silver chromate Chemical compound

Silver chromate is an inorganic compound with formula Ag2CrO4 which appears as distinctively coloured brown-red crystals. The compound is insoluble and its precipitation is indicative of the reaction between soluble chromate and silver precursor salts (commonly potassium/sodium chromate with silver nitrate). This reaction is important for two uses in the laboratory: in analytical chemistry it constitutes the basis for the Mohr method of argentometry, whereas in neuroscience it is used in the Golgi method of staining neurons for microscopy.

Thermometric titration

A thermometric titration is one of a number of instrumental titration techniques where endpoints can be located accurately and precisely without a subjective interpretation on the part of the analyst as to their location. Enthalpy change is arguably the most fundamental and universal property of chemical reactions, so the observation of temperature change is a natural choice in monitoring their progress. It is not a new technique, with possibly the first recognizable thermometric titration method reported early in the 20th century. In spite of its attractive features, and in spite of the considerable research that has been conducted in the field and a large body of applications that have been developed; it has been until now an under-utilized technique in the critical area of industrial process and quality control. Automated potentiometric titration systems have pre-dominated in this area since the 1970s. With the advent of cheap computers able to handle the powerful thermometric titration software, development has now reached the stage where easy to use automated thermometric titration systems can in many cases offer a superior alternative to potentiometric titrimetry.

Potentiometric titration is a technique similar to direct titration of a redox reaction. It is a useful means of characterizing an acid. No indicator is used; instead the potential is measured across the analyte, typically an electrolyte solution. To do this, two electrodes are used, an indicator electrode and a reference electrode. Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half cell with the interested ions in the test solution. The reference electrode forms the other half cell.

A chloridometer is a measuring instrument used to determine the concentration of chloride ions (Cl) in a solution. It uses a process known as coulometric titration or amperostatic coulometry, the accepted electrochemistry reference method to determine the concentration of chloride in biological fluids, including blood serum, blood plasma, urine, sweat, and cerebrospinal fluid. The coulometry process generates silver ions, which react with the chloride to form silver chloride (AgCl).

References

  1. 1 2 Yoder, Lester (1919). "Adaptation of the Mohr Volumetric Method to General Determinations of Chlorine". Industrial & Engineering Chemistry. 11 (8): 755. doi:10.1021/ie50116a013.
  2. Harris, Daniel Charles (2003). Quantitative chemical analysis (6th ed.). San Francisco: W.H. Freeman. pp. 142–143. ISBN   0-7167-4464-3.