Coefficient diagram method

Last updated

In control theory, the coefficient diagram method (CDM) is an algebraic approach applied to a polynomial loop in the parameter space. A special diagram called a "coefficient diagram" is used as the vehicle to carry the necessary information and as the criterion of good design. [1] The performance of the closed-loop system is monitored by the coefficient diagram.

Contents

The most considerable advantages of CDM can be listed as follows: [2]

  1. The design procedure is easily understandable, systematic and useful. Therefore, the coefficients of the CDM controller polynomials can be determined more easily than those of the PID or other types of controller. This creates the possibility of an easy realisation for a new designer to control any kind of system.
  2. There are explicit relations between the performance parameters specified before the design and the coefficients of the controller polynomials as described in. [3] For this reason, the designer can easily realize many control systems having different performance properties for a given control problem in a wide range of freedom.
  3. The development of different tuning methods is required for time delay processes of different properties in PID control. But it is sufficient to use the single design procedure in the CDM technique. This is an outstanding advantage. [4]
  4. It is particularly hard to design robust controllers realizing the desired performance properties for unstable, integrating and oscillatory processes having poles near the imaginary axis. It has been reported that successful designs can be achieved even in these cases by using CDM. [5]
  5. It is theoretically proven that CDM design is equivalent to LQ design with proper state augmentation. Thus, CDM can be considered an ‘‘improved LQG’’, because the order of the controller is smaller and weight selection rules are also given. [6]

It is usually required that the controller for a given plant should be designed under some practical limitations. The controller is desired to be of minimum degree, minimum phase (if possible) and stable. It must have enough bandwidth and power rating limitations. If the controller is designed without considering these limitations, the robustness property will be very poor, even though the stability and time response requirements are met. CDM controllers designed while considering all these problems is of the lowest degree, has a convenient bandwidth and results with a unit step time response without an overshoot. These properties guarantee the robustness, the sufficient damping of the disturbance effects and the low economic property. [7]

Although the main principles of CDM have been known since the 1950s, [8] [9] [10] the first systematic method was proposed by Shunji Manabe. [11] He developed a new method that easily builds a target characteristic polynomial to meet the desired time response. CDM is an algebraic approach combining classical and modern control theories and uses polynomial representation in the mathematical expression. The advantages of the classical and modern control techniques are integrated with the basic principles of this method, which is derived by making use of the previous experience and knowledge of the controller design. Thus, an efficient and fertile control method has appeared as a tool with which control systems can be designed without needing much experience and without confronting many problems.

Many control systems have been designed successfully using CDM. [12] [13] It is very easy to design a controller under the conditions of stability, time domain performance and robustness. The close relations between these conditions and coefficients of the characteristic polynomial can be simply determined. This means that CDM is effective not only for control system design but also for controller parameters tuning.

See also

Related Research Articles

Control theory is a field of control engineering and applied mathematics that deals with the control of dynamical systems in engineered processes and machines. The objective is to develop a model or algorithm governing the application of system inputs to drive the system to a desired state, while minimizing any delay, overshoot, or steady-state error and ensuring a level of control stability; often with the aim to achieve a degree of optimality.

A proportional–integral–derivative controller is a control loop mechanism employing feedback that is widely used in industrial control systems and a variety of other applications requiring continuously modulated control. A PID controller continuously calculates an error value as the difference between a desired setpoint (SP) and a measured process variable (PV) and applies a correction based on proportional, integral, and derivative terms, hence the name.

<span class="mw-page-title-main">Control system</span> System that manages the behavior of other systems

A control system manages, commands, directs, or regulates the behavior of other devices or systems using control loops. It can range from a single home heating controller using a thermostat controlling a domestic boiler to large industrial control systems which are used for controlling processes or machines. The control systems are designed via control engineering process.

<span class="mw-page-title-main">Root locus analysis</span> Stability criterion in control theory

In control theory and stability theory, root locus analysis is a graphical method for examining how the roots of a system change with variation of a certain system parameter, commonly a gain within a feedback system. This is a technique used as a stability criterion in the field of classical control theory developed by Walter R. Evans which can determine stability of the system. The root locus plots the poles of the closed loop transfer function in the complex s-plane as a function of a gain parameter.

An industrial process control or simply process control in continuous production processes is a discipline that uses industrial control systems and control theory to achieve a production level of consistency, economy and safety which could not be achieved purely by human manual control. It is implemented widely in industries such as automotive, mining, dredging, oil refining, pulp and paper manufacturing, chemical processing and power generating plants.

Model predictive control (MPC) is an advanced method of process control that is used to control a process while satisfying a set of constraints. It has been in use in the process industries in chemical plants and oil refineries since the 1980s. In recent years it has also been used in power system balancing models and in power electronics. Model predictive controllers rely on dynamic models of the process, most often linear empirical models obtained by system identification. The main advantage of MPC is the fact that it allows the current timeslot to be optimized, while keeping future timeslots in account. This is achieved by optimizing a finite time-horizon, but only implementing the current timeslot and then optimizing again, repeatedly, thus differing from a linear–quadratic regulator (LQR). Also MPC has the ability to anticipate future events and can take control actions accordingly. PID controllers do not have this predictive ability. MPC is nearly universally implemented as a digital control, although there is research into achieving faster response times with specially designed analog circuitry.

Adaptive control is the control method used by a controller which must adapt to a controlled system with parameters which vary, or are initially uncertain. For example, as an aircraft flies, its mass will slowly decrease as a result of fuel consumption; a control law is needed that adapts itself to such changing conditions. Adaptive control is different from robust control in that it does not need a priori information about the bounds on these uncertain or time-varying parameters; robust control guarantees that if the changes are within given bounds the control law need not be changed, while adaptive control is concerned with control law changing itself.

In control theory, quantitative feedback theory (QFT), developed by Isaac Horowitz, is a frequency domain technique utilising the Nichols chart (NC) in order to achieve a desired robust design over a specified region of plant uncertainty. Desired time-domain responses are translated into frequency domain tolerances, which lead to bounds on the loop transmission function. The design process is highly transparent, allowing a designer to see what trade-offs are necessary to achieve a desired performance level.

In control theory, robust control is an approach to controller design that explicitly deals with uncertainty. Robust control methods are designed to function properly provided that uncertain parameters or disturbances are found within some set. Robust methods aim to achieve robust performance and/or stability in the presence of bounded modelling errors.

Nonlinear control theory is the area of control theory which deals with systems that are nonlinear, time-variant, or both. Control theory is an interdisciplinary branch of engineering and mathematics that is concerned with the behavior of dynamical systems with inputs, and how to modify the output by changes in the input using feedback, feedforward, or signal filtering. The system to be controlled is called the "plant". One way to make the output of a system follow a desired reference signal is to compare the output of the plant to the desired output, and provide feedback to the plant to modify the output to bring it closer to the desired output.

The theory of optimal control is concerned with operating a dynamic system at minimum cost. The case where the system dynamics are described by a set of linear differential equations and the cost is described by a quadratic function is called the LQ problem. One of the main results in the theory is that the solution is provided by the linear–quadratic regulator (LQR), a feedback controller whose equations are given below.

Integral windup, also known as integrator windup or reset windup, refers to the situation in a PID controller where a large change in setpoint occurs and the integral term accumulates a significant error during the rise (windup), thus overshooting and continuing to increase as this accumulated error is unwound.

Kharitonov's theorem is a result used in control theory to assess the stability of a dynamical system when the physical parameters of the system are not known precisely. When the coefficients of the characteristic polynomial are known, the Routh–Hurwitz stability criterion can be used to check if the system is stable. Kharitonov's theorem can be used in the case where the coefficients are only known to be within specified ranges. It provides a test of stability for a so-called interval polynomial, while Routh–Hurwitz is concerned with an ordinary polynomial.

Control reconfiguration is an active approach in control theory to achieve fault-tolerant control for dynamic systems. It is used when severe faults, such as actuator or sensor outages, cause a break-up of the control loop, which must be restructured to prevent failure at the system level. In addition to loop restructuring, the controller parameters must be adjusted to accommodate changed plant dynamics. Control reconfiguration is a building block toward increasing the dependability of systems under feedback control.

H-infinity loop-shaping is a design methodology in modern control theory. It combines the traditional intuition of classical control methods, such as Bode's sensitivity integral, with H-infinity optimization techniques to achieve controllers whose stability and performance properties hold despite bounded differences between the nominal plant assumed in design and the true plant encountered in practice. Essentially, the control system designer describes the desired responsiveness and noise-suppression properties by weighting the plant transfer function in the frequency domain; the resulting 'loop-shape' is then 'robustified' through optimization. Robustification usually has little effect at high and low frequencies, but the response around unity-gain crossover is adjusted to maximise the system's stability margins. H-infinity loop-shaping can be applied to multiple-input multiple-output (MIMO) systems.

Iso-damping is a desirable system property referring to a state where the open-loop phase Bode plot is flat—i.e., the phase derivative with respect to the frequency is zero, at a given frequency called the "tangent frequency", . At the "tangent frequency" the Nyquist curve of the open-loop system tangentially touches the sensitivity circle and the phase Bode is locally flat which implies that the system will be more robust to gain variations. For systems that exhibit iso-damping property, the overshoots of the closed-loop step responses will remain almost constant for different values of the controller gain. This will ensure that the closed-loop system is robust to gain variations.

In control theory the Youla–Kučera parametrization is a formula that describes all possible stabilizing feedback controllers for a given plant P, as function of a single parameter Q.

The following outline is provided as an overview of and topical guide to control engineering:

Linear parameter-varying control deals with the control of linear parameter-varying systems, a class of nonlinear systems which can be modelled as parametrized linear systems whose parameters change with their state.

Classical control theory is a branch of control theory that deals with the behavior of dynamical systems with inputs, and how their behavior is modified by feedback, using the Laplace transform as a basic tool to model such systems.

References

  1. S. Manabe (1998), "Coefficient Diagram Method", 14th IFAC Symp. on Automatic Control in Aerospace, Seoul.
  2. S.E. Hamamci, "A robust polynomial-based control for stable processes with time delay", Electrical Engineering, vol: 87, pp.163–172, 2005.
  3. S. Manabe (1998), "Coefficient Diagram Method", 14th IFAC Symp. on Automatic Control in Aerospace, Seoul.
  4. S.E. Hamamci, I. Kaya and D.P. Atherton, "Smith predictor design by CDM", Proceedings of the ECC’01 European Control Conference, Semina´rio de Vilar, Porto, Portugal, 2001.
  5. S. Manabe, "A low cost inverted pendulum system for control system education", The 3rd IFAC Symposium on advances in Control Education, Tokyo, 1994.
  6. S. Manabe, "Analytical weight selection for LQ design", Proceedings of the 8th Workshop on Astrodynamics and Flight Mechanics, Sagamihara, ISAS, 1998.
  7. S. Manabe and Y.C. Kim, "Recent development of coefficient diagram method", Proceedings of the ASSC’2000 3rd Asian Control Conference, Shanghai, 2000.
  8. D. Graham and R.C. Lathrop, "The synthesis of optimum transient response: criteria and standard forms", AIEE Trans., vol:72, pp.273–288, 1953.
  9. P. Naslin, Essentials of optimal control, Boston Technical Publishers, Cambridge, MA, 1969.
  10. A.V. Lipatov and N. Sokolov, "Some sufficient conditions for stability and instability of continuous linear stationary systems", Automat. Remote Control, vol:39, pp.1285–1291, 1979.
  11. Y.C. Kim and S. Manabe, "Introduction to coefficient diagram method" Proceedings of the SSSC’01, Prague, 2001.
  12. S. Manabe, "A low cost inverted pendulum system for control system education", The 3rd IFAC Symposium on advances in Control Education, Tokyo, 1994.
  13. S.E. Hamamci, M. Koksal and S. Manabe, "On the control of some nonlinear systems with the coefficient diagram method", Proceedings of the 4th Asian Control Conference, Singapore, 2002.

.