Electric shock drowning

Last updated

Electric shock drowning is a term used in the US to describe a cause of death that occurs when swimmers are exposed to electric currents in the water. In some cases the shock itself is fatal, since the person will suffocate when their diaphragm is paralyzed, while in others it incapacitates the swimmer causing them to drown. The main cause of electric shock drownings is faulty electrical wiring on boats or piers that causes electric current to leak into the water. Electric shock drownings occur most often in fresh water, which is conductive due to dissolved minerals and impurities. The increased conductivity of saltwater reduces the fraction of the electric current that flows through a submerged person, whose body has a much smaller conductivity than the saltwater. In this case, the current to cause electric shock drowning would be so great that current-limiting circuit breakers would trip and shut off the current, thereby protecting against electric shock drowning in saltwater. [1] [2]

Contents

Sometimes Electric Shock Drowning is referred to as ESD but this should not be used, as it can be confused with the IEC defined term for Electrostatic discharge (ESD). [3] For some reason, the accident type is prevalent only in the USA. [4]

Causes

Electric shock drownings are most commonly caused by improper electrical connections on boats and piers. By law, all connections near water are required to have working ground fault circuit interruption technology, GFCI. These devices break the electrical circuit if any stray current fails to return to the source connection. If GFCI devices are missing or faulty, it is possible for current to leak into the water. If a system is leaking current into the water, appliances will likely function as normal without any indication of a problem. Correctly functioning GFCI and ELCI devices will instantaneously detect the problem and disconnect the power source.

Special attention is required toward electrical safety devices on boats. These safety devices can fail for various reasons. Since deterioration of insulation on wires is common in boating conditions it is critical for these devices to work properly. [5]

Besides boats and dockside power hookups, several other potential causes exist. Lightning strikes over or near water have caused electric shock drownings. Faulty hydroelectric generators or damaged underwater power lines can cause leakage currents, potentially creating a hazard. In general, anything electrically active that comes in contact with water has the potential to create leakage currents and contribute to this type of safety hazard.

Prevention

Beyond ensuring that all electrical hookups on piers and boats in the vicinity are code compliant and safe, various precautions can be taken by the swimmer. The primary method is to swim at a safe distance from all electrically active devices. One source recommends keeping a distance of at least 100 yards from freshwater marinas while swimming. [6]

Although sensors exist that can detect leakage current in the water, these are unsuitable to use as an alarm device. These instruments provide no advanced warning before a problem starts. If a hazard condition is created, swimmers will be affected at the same time the instrument detects the current. It is common for faults to be tied to appliances or circuits that come on intermittently, meaning that the condition of the water can change instantly and unpredictably. [7]

The best strategy for avoiding electrical hazards is to swim in designated areas well away from any devices that present a risk.

Signs

There is no visible warning to electrified water. [8] Swimmers will be able to feel the electricity if the current is substantial. If the swimmers notice any unusual tingling feeling or symptoms of electrical shock, it is highly likely that stray currents exist and everyone needs to get out. Swimmers should always swim away from the suspected current source. In most cases this means swimming away from piers and boats and toward another safer portion of the shoreline.

Rescue

The primary method of rescue is to get the swimmer away from the current source by any means possible, EXCEPT by sending out rescue swimmers. This means Row and Throw, but do not Go. If stray currents are suspected, a rescue by another swimmer should never be attempted. For cases where swimmers can feel mild tingling, getting flotation devices out to them can aid them to swim away from the current source under their own power. In cases where the current source is obvious, it may be possible for bystanders on foot to disconnect it. Dockside power hookups often have integrated or nearby breakers by which the source can be de-energized.

Treatment

Once the victim is safely on shore, first aid may be needed. Treatment depends on the specifics of each case, but is likely some combination of the treatments for electrocution and drowning individually. Even if the victim seems well, examination by healthcare professional is recommended as latent effects from the electricity may be undetected.

Related Research Articles

<span class="mw-page-title-main">Insulator (electricity)</span> Material that does not conduct an electric current

An electrical insulator is a material in which electric current does not flow freely. The atoms of the insulator have tightly bound electrons which cannot readily move. Other materials—semiconductors and conductors—conduct electric current more easily. The property that distinguishes an insulator is its resistivity; insulators have higher resistivity than semiconductors or conductors. The most common examples are non-metals.

<span class="mw-page-title-main">Ground (electricity)</span> Reference point in an electrical circuit from which voltages are measured

In electrical engineering, ground or earth is a reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.

<span class="mw-page-title-main">Electrostatic discharge</span> Sudden flow of electric current between 2 electrically charged objects by contact

Electrostatic discharge (ESD) is a sudden and momentary flow of electric current between two electrically charged objects caused by contact, an electrical short or dielectric breakdown. A buildup of static electricity can be caused by tribocharging or by electrostatic induction. The ESD occurs when differently-charged objects are brought close together or when the dielectric between them breaks down, often creating a visible spark.

<span class="mw-page-title-main">Static electricity</span> Imbalance of electric charges within or on the surface of a material

Static electricity is an imbalance of electric charges within or on the surface of a material or between materials. The charge remains until it is able to move away by means of an electric current or electrical discharge. Static electricity is named in contrast with current electricity, where the electric charge flows through an electrical conductor or space, and transmits energy.

<span class="mw-page-title-main">Short circuit</span> Electrical circuit with negligible impedance

A short circuit is an electrical circuit that allows a current to travel along an unintended path with no or very low electrical impedance. This results in an excessive current flowing through the circuit. The opposite of a short circuit is an open circuit, which is an infinite resistance between two nodes.

Electrical wiring in North America follows the regulations and standards applicable at the installation location. It is also designed to provide proper function, and is also influenced by history and traditions of the location installation.

<span class="mw-page-title-main">Residual-current device</span> Electrical safety device used in household wiring

A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device that quickly breaks an electrical circuit with leakage current to ground. It is to protect equipment and to reduce the risk of serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a human receives a brief shock before the electrical circuit is isolated, falls after receiving a shock, or if the person touches both conductors at the same time.

<span class="mw-page-title-main">Earth-leakage circuit breaker</span> Electrical safety device

An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use residual-current devices which instead detect leakage current directly.

Appliance classes specify measures to prevent dangerous contact voltages on unenergized parts, such as the metallic casing, of an electronic device. In the electrical appliance manufacturing industry, the following appliance classes are defined in IEC 61140 and used to differentiate between the protective-earth connection requirements of devices.

In an electrical system, a ground loop or earth loop occurs when two points of a circuit are intended to have the same ground reference potential but instead have a different potential between them. This is typically caused when enough current is flowing in the connection between the two ground points to produce a voltage drop and cause two points to be at different potentials. Current may be produced in a circular ground connection by electromagnetic induction.

In electrical engineering, ground and neutral are circuit conductors used in alternating current (AC) electrical systems. The ground circuit is connected to earth, and neutral circuit is usually connected to ground. As the neutral point of an electrical supply system is often connected to earth ground, ground and neutral are closely related. Under certain conditions, a conductor used to connect to a system neutral is also used for grounding (earthing) of equipment and structures. Current carried on a grounding conductor can result in objectionable or dangerous voltages appearing on equipment enclosures, so the installation of grounding conductors and neutral conductors is carefully defined in electrical regulations. Where a neutral conductor is used also to connect equipment enclosures to earth, care must be taken that the neutral conductor never rises to a high voltage with respect to local ground.

An earthing system or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect the safety and electromagnetic compatibility of the installation. Regulations for earthing systems vary among countries, though most follow the recommendations of the International Electrotechnical Commission (IEC). Regulations may identify special cases for earthing in mines, in patient care areas, or in hazardous areas of industrial plants.

<span class="mw-page-title-main">Test light</span>

A test light, test lamp, voltage tester, or mains tester is a piece of electronic test equipment used to determine the presence of electricity in a piece of equipment under test. A test light is simpler and less costly than a measuring instrument such as a multimeter, and often suffices for checking for the presence of voltage on a conductor. Properly designed test lights include features to protect the user from accidental electric shock. Non-contact test lights can detect voltage on insulated conductors.

Electrical bonding is the practice of intentionally electrically connecting all exposed metal items not designed to carry electricity in a room or building as protection from electric shock. If a failure of electrical insulation occurs, all bonded metal objects in the room will have substantially the same electrical potential, so that an occupant of the room cannot touch two objects with significantly different potentials. Even if the connection to a distant earth is lost, the occupant will be protected from dangerous potential differences.

<span class="mw-page-title-main">Stray voltage</span> Electrical potential between unexpected places

Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.

<span class="mw-page-title-main">Electrofishing</span>

Electrofishing is a fishing technique that uses direct current electricity flowing between a submerged cathode and anode. This affects the movements of nearby fish so that they swim toward the anode, where they can be caught or stunned.

In electronics, leakage is the gradual transfer of electrical energy across a boundary normally viewed as insulating, such as the spontaneous discharge of a charged capacitor, magnetic coupling of a transformer with other components, or flow of current across a transistor in the "off" state or a reverse-polarized diode.

<span class="mw-page-title-main">Cheater plug</span>

A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug to connect to a NEMA 1-15R non-grounding receptacle. They are needed to allow appliances with 3-wire power cords to plug into legacy ungrounded receptacles found in older buildings. The use of such an adapter avoids the need to replace receptacles, but is potentially hazardous if the grounding tab is not connected to electrical ground. These adapters are illegal in some jurisdictions, in particular throughout Canada. A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet.

<span class="mw-page-title-main">Failure of electronic components</span> Ways electronic components fail and prevention measures

Electronic components have a wide range of failure modes. These can be classified in various ways, such as by time or cause. Failures can be caused by excess temperature, excess current or voltage, ionizing radiation, mechanical shock, stress or impact, and many other causes. In semiconductor devices, problems in the device package may cause failures due to contamination, mechanical stress of the device, or open or short circuits.

<span class="mw-page-title-main">Electrical burn</span>

An electrical burn is a burn that results from electricity passing through the body causing rapid injury. Approximately 1000 deaths per year due to electrical injuries are reported in the United States, with a mortality rate of 3-5%. Electrical burns differ from thermal or chemical burns in that they cause much more subdermal damage. They can exclusively cause surface damage, but more often tissues deeper underneath the skin have been severely damaged. As a result, electrical burns are difficult to accurately diagnose, and many people underestimate the severity of their burn. In extreme cases, electricity can cause shock to the brain, strain to the heart, and injury to other organs.

References

  1. Cargill III, G. S. (2017). Electric Shock Drowning: Causes and Prevention. CreateSpace Independent Publishing. pp. 33, 38. ISBN   978-1545330074.
  2. Morse, M.; Kotsch, J.; Prussak, B.; Kohl, J. G. (July 2020). "Examining the Risk of Electric Shock Drowning (ESD) As a Function of Water Conductivity". IEEE Transactions on Industry Applications. 56 (4): 4324–4328. doi:10.1109/TIA.2020.2982854. ISSN   1939-9367. S2CID   220668782.
  3. "IEC 60050 - International Electrotechnical Vocabulary - Details for IEV number 161-01-22: "electrostatic discharge"". www.electropedia.org. Retrieved 2019-03-11.
  4. Linja-aho, V. (2020). "Discussion of "Examining the Risk of Electric Shock Drowning (ESD) As a Function of Water Conductivity"". IEEE Transactions on Industry Applications. 57: 1138–1139. doi: 10.1109/TIA.2020.3032949 . ISSN   1939-9367.
  5. "Key Ways to Prevent Electric Shock Drowning" . Retrieved 2017-04-22.
  6. "ESD Explained" . Retrieved 2017-04-22.
  7. "Electric Shock Drowning FAQ" . Retrieved 2017-04-22.
  8. Electrical Safety Foundation International "Electric Shock Drowning - Unknown Danger Lurking in the Water"