Encasement is the coating over, covering or "encasing" of all building components, interior and exterior. This includes all roofing and toxic hazards materials, such as asbestos, lead-based paint, mold/mildew and other harmful substances, found in buildings. The technique of encasing all building components, including unsafe ones, with green coatings is by far the most efficient way to reduce the harmful effects on people and the environment while lengthening the life of buildings. It is an economical alternative to other abatement methods such as removal, disposal and replacement.

Contents

Encasement with green coatings is a long-term, sustainable, and renewable solution compared to typical paints or coatings which only last a few years. In place management and restoration with encasement green coatings is the best and most practical way to extend a buildings life along with safely dealing with most of its components.

Encasement is also less disruptive of ongoing services. It does not require shutting down buildings or having to relocate occupants, which is costly and time-consuming. Most work can be completed with minimal amount of time and with no building disruption at all.

Encasement with green coatings can result in savings of 25% to 75% over removal and replacement, and extend the life of most building surfaces.

Green coatings have no environmental downside to using them. They are non-toxic, water based, low VOCs, (volatile organic compounds), no ODS (Ozone Depleting Substances), and Class A fire rated. The products are backed up with toxicological reports proving that they are so clean, that pregnant women and children can be present when applying them.

Green coatings used for encasement should be extremely durable, long lasting and able to take a lot of abuse. They must be especially flexible; being able to elongate with the expanding and contracting of any typical building movements. [1]

Abatement methods

Since the early 1980s, four major methods have been used for the abatement of Asbestos-Containing Materials (ACM) and Lead-Based Paint (LBP).

Enclosures – Dust-tight barriers such as sheetrock or plywood are erected to protect against the release of the hazardous material into the environment. When the enclosure is eventually removed, the hazardous material is once again exposed and it usually has become more friable and prone to being released into the atmosphere. Care must be taken to insure that untrained or uninformed workers do not re-expose the hazardous surfaces unknowingly and endanger themselves and/or the inhabitants by causing a release into the environment. [2]

Encapsulation – A coating material that passes U.S. Environmental Protection Agency-specified (EPA) ASTM (American Society for Testing Materials) tests is applied over a surface to prevent the release of hazardous materials into the atmosphere. A problem experienced with encapsulants in some cases is that the added weight of the encapsulant can cause ACM fireproofing on ceilings or walls to delaminate. A second potential problem with encapsulants is that if the coating is compromised (e.g. by a forklift truck running into a column that has been encapsulated, the potential for release of the hazardous material into the environment is once again present. With LBP, a significant amount of scraping of loose, flaking paint is often required to provide a stable surface before the encapsulant that is applied can be expected to achieve adequate adhesion. [2]

Encasement – A 2-coat system which also passes EPA-specified ASTM testing wherein the first coat (primer) stabilizes the substrate by penetrating into the friable ACM and through the loose flaking paint and cures into a flexible film that mitigates these hazardous properties. The second coat bonds to the topcoat providing a tough, long-lasting, monolithic, composite coating system that prevents the release of any hazardous material into the environment. Because of the penetration of the primer, the adhesion of the overall system is increased. A necessity as the weight of the system increases. Additionally if the outer coat is compromised in any manner, there is little or no risk of the hazardous material being released because the surface-stabilizing primer has mitigated the brittle, chalky and friable properties of the hazardous surface. In a very real sense, encasement can be viewed as "stabilization + encapsulation".

Removal and Replacement- removal of ACM or LBP causes the release of asbestos fibers and lead dust that can become airborne subjecting installers and/or occupants to the risk of inhaling the particulate matter. Based on industry trends, the increased risk associated with this method has led building owners and contractors to select this as the least preferred method and a last resort unless the ACM is in a friable condition. Due to its high cost and risk factors, only certified and insured abatement professionals should perform this method. If a party is exposed to these risks and are affected, symptoms of various diseases such as asbestosis, a scarring of lung tissue that leads to difficulty in breathing and mesothelioma (an always fatal cancer of the lung’s external lining) may not appear for 15 years. In addition, removal and replacement is time-consuming, carries high insurance costs, causes building use downtime and requires relocation of occupants. It also requires the disposal of the hazardous materials, which alone can amount to 30% of total abatement costs. Consequently, an ever-increasing number of building owners choose alternative in place management methods.

Pros and cons of encasement

PROSCONS
Installation does not disturb asbestos fibers or lead dustThe hazardous materials remain in place, if catastrophic damage occurs they may be released into the surrounding environment
Conforms to safety measures for installers and occupants of dwellings during implementation of corrective actions
Lasts for the life of the building
Minimal to no relocation of building occupants
Can be installed after work hours thereby limiting downtime in an organization
Does not affect the fireproof rating of the structure
Retains the superior fireproofing qualities of asbestos
Prevents lead leachate
No need to scarify surfaces, remove walls or trim
Non-destructive—permits preservation of architectural features (wood, plaster, metals, etc.)
Excellent protection and preservation
Water-based (safe), non-toxic, low VOCs
Can be custom tinted
Protects surfaces from damage
Hazardous waste in place management eliminates hazardous material waste transport and disposal

Additional facts

encasement system.

Application of encasement

Encasement is defined by the U.S. Environmental Protection Agency as a, "Spray applied enclosure" abatement method that safely and economically seals and encloses exposed hazardous material surfaces. Encasement differs from encapsulation in that it is a long-term solution; the materials are thicker, applied from 7 to 40 mils depending upon surface conditions, building use and desired warranty, are impact resistant and can allow for mechanical fasteners to be adhered to the surface. Materials used for this method should be water-based and must possess elastomeric properties. The outer shell of the encasement is highly resistant to damage from ultra-violet light, heat, water, acids, accidental or direct impact, seismic and mechanical occurrences. This method is installed without disturbing the asbestos fibers and lead dust, requires minimal to no relocation and can be installed after work hours thereby limiting downtime in an organization.

The coating materials that make up the basic encasement system are water-based acrylic elastomers that contain no volatile organic compounds (VOCs). As such they are very safe to work with. A corrosion-inhibiting version of the primer is used when dealing with metal surfaces. Spraying, brushing or rolling may be used to apply all of the products and cleanup is with water. Use of a coating technology-based solution such as encasement usually results in savings of 50-80 percent when compared with the cost of removal and replacement, not including comparable savings in relocation costs in many cases. According to the U.S. EPA, to qualify as an approved 20-year encapsulant/encasement system for use over LBP the coatings must pass a series of ASTM performance tests that are encompassed by ASTM E1795-97. Little or no hazardous waste is generated. Because this is elastomeric technology, cracking, chipping or peeling will never occur.

See also

Related Research Articles

Paint Pigment applied over a surface that dries as a solid film

Paint is any pigmented liquid, liquefiable, or solid mastic composition that, after application to a substrate in a thin layer, converts to a solid film. It is most commonly used to protect, color, or provide texture. Paint can be made or purchased in many colors—and in many different types. Paint is typically stored, sold, and applied as a liquid, but most types dry into a solid. Most paints are either oil-based or water-based and each has distinct characteristics. For one, it is illegal in most municipalities to discard oil-based paint down household drains or sewers. Clean-up solvents are also different for water-based paint than they are for oil-based paint. Water-based paints and oil-based paints will cure differently based on the outside ambient temperature of the object being painted Usually, the object being painted must be over 10 °C (50 °F), although some manufacturers of external paints/primers claim they can be applied when temperatures are as low as 2 °C (35 °F).

Indoor air quality Air quality within and around buildings and structures

Indoor air quality (IAQ) is the air quality within and around buildings and structures. IAQ is known to affect the health, comfort, and well-being of building occupants. Poor indoor air quality has been linked to sick building syndrome, reduced productivity, and impaired learning in schools.

Vermiculite Hydrous phyllosilicate mineral which expands significantly when heated

Vermiculite is a hydrous phyllosilicate mineral which undergoes significant expansion when heated. Exfoliation occurs when the mineral is heated sufficiently, and commercial furnaces can routinely produce this effect. Vermiculite forms by the weathering or hydrothermal alteration of biotite or phlogopite. Large commercial vermiculite mines currently exist in the United States, Russia, South Africa, China, and Brazil.

Dye penetrant inspection (DP), also called liquid penetrate inspection (LPI) or penetrant testing (PT), is a widely applied and low-cost inspection method used to check surface-breaking defects in all non-porous materials. The penetrant may be applied to all non-ferrous materials and ferrous materials, although for ferrous components magnetic-particle inspection is often used instead for its subsurface detection capability. LPI is used to detect casting, forging and welding surface defects such as hairline cracks, surface porosity, leaks in new products, and fatigue cracks on in-service components.

Vinyl composition tile Flooring material

Vinyl composition tile (VCT) is a finished flooring material used primarily in commercial and institutional applications. Modern vinyl floor tiles and sheet flooring and versions of those products sold since the early 1980s are composed of colored polyvinyl chloride (PVC) chips formed into solid sheets of varying thicknesses by heat and pressure. Floor tiles are cut into modular shapes such 12-by-12-inch squares or 12-by-24-inch rectangles. In installation the floor tiles or sheet flooring are applied to a smooth, leveled sub-floor using a specially formulated vinyl adhesive or tile mastic that remains pliable. In commercial applications some tiles are typically waxed and buffed using special materials and equipment.

Waterproofing Process of making an object or structure waterproof or water-resistant

Waterproofing is the process of making an object or structure waterproof or water-resistant so that it remains relatively unaffected by water or resisting the ingress of water under specified conditions. Such items may be used in wet environments or underwater to specified depths.

Delamination Mode of failure for which a material fractures into layers

Delamination is a mode of failure where a material fractures into layers. A variety of materials including laminate composites and concrete can fail by delamination. Processing can create layers in materials such as steel formed by rolling and plastics and metals from 3D printing which can fail from layer separation. Also, surface coatings such as paints and films can delaminate from the coated substrate.

Artex

Artex is a surface coating used for interior decorating, most often found on ceilings, which allows the decorator to add a texture to it. The name Artex is a trademark of Artex Ltd., a company based in the United Kingdom. The name is a genericised trademark often used to refer to similar products from other manufacturers. Since 2005, the company has belonged to France's Saint-Gobain group.

Friability, the condition of being friable, describes the tendency of a solid substance to break into smaller pieces under duress or contact, especially by rubbing. The opposite of friable is indurate.

Asphalt shingle Type of shingle

An asphalt shingle is a type of wall or roof shingle that uses asphalt for waterproofing. It is one of the most widely used roofing covers in North America because it has a relatively inexpensive up-front cost and is fairly simple to install.

The salt spray test is a standardized and popular corrosion test method, used to check corrosion resistance of materials and surface coatings. Usually, the materials to be tested are metallic and finished with a surface coating which is intended to provide a degree of corrosion protection to the underlying metal.

Phase I environmental site assessment Identifies environment contamination risk

In the United States, an environmental site assessment is a report prepared for a real estate holding that identifies potential or existing environmental contamination liabilities. The analysis, often called an ESA, typically addresses both the underlying land as well as physical improvements to the property. A proportion of contaminated sites are "brownfield sites." In severe cases, brownfield sites may be added to the National Priorities List where they will be subject to the U.S. Environmental Protection Agency's Superfund program.

Asbestos abatement

In construction, asbestos abatement is a set of procedures designed to control the release of asbestos fibers from asbestos-containing materials. Asbestos abatement is utilized during general construction in areas containing asbestos materials, particularly when those materials are being removed, encapsulated, or repaired. Abatement is needed in order to protect construction workers and members of the general public from the many negative health impacts of asbestos.

Paint adhesion testing

In the paint and coating industries, paint adhesion testing is often used to determine if the paint or coating will adhere properly to the substrates to which they are applied. There are several different tests to measure the resistance of paints and coatings from substrates: cross-cut test, scrape adhesion, pull-off test, and others.

Asbestos Group of highly stable, non-flammable silicate minerals with a fibrous structure

Asbestos is a naturally occurring fibrous silicate mineral. There are six types, all of which are composed of long and thin fibrous crystals, each fibre being composed of many microscopic "fibrils" that can be released into the atmosphere by abrasion and other processes. Inhalation of asbestos fibres can lead to various dangerous lung conditions, including mesothelioma, asbestosis, and lung cancer, so it is now notorious as a serious health and safety hazard.

Lead-based paint in the United States Manufacture of banned in 1978 though widely used because of its durability.

Lead-based paint was widely used in the United States, because of its durability. The United States banned the manufacture of lead-based house paint in 1978 due to health concerns.

Liquid roofing

Liquid Roofing is the process of waterproofing a roof by the application of a specialist liquid roof coating. It is suited to all types of roof, including flat, pitched, and domed.

Ice blasting is a form of non-abrasive blasting where frozen water particles are combined with compressed air and propelled towards a surface for cleaning purposes. Ice is one of several different medias commonly used for blast cleaning. Another common method of non-abrasive blasting is dry ice blasting, which uses the solid form of CO2 as a blast media. Forms of abrasive blasting use mediums such as sand, plastic beads, and baking soda.

Lead abatement The reduction of lead, particularly in homes

Lead abatement includes lead-based paint abatement activities, such as inspections, risk assessments, and removal, that must be performed by educated, certified professionals and are aimed to permanently eliminate lead-based paint hazards, such as serious permanent and irreversible health damage due to lead poisoning in children, from the home environment and any facility with frequent visitation by children, particularly those built before 1978.

Lead abatement in the United States

Lead abatement is an activity to reduce levels of lead, particularly in the home environment, generally to permanently eliminate lead-based paint hazards, in order to reduce or eliminate incidents of lead poisoning.

References

  1. "About Encasement: In Place Management vs. Removal and Replacement".
  2. 1 2 "EPA/OPPT/Asbestos - Asbestos in Your Home". www.epa.gov. Archived from the original on 11 April 2006.