Infrared and thermal testing

Last updated
Inset shows false color infrared thermograph of a roof on a sunny day; the white surfaces (colored blue in the thermograph) have been coated with an elastomer to reduce solar loading and have a surface temperature of approximately 60 degF (16 degC); the gray surfaces (colored red/white in the thermogram) are a standard asphalt (bitumen) coating and have a surface temperature of approximately 160 degF (71 degC). Infrared Thermography of Modified Bitumen Roof.jpg
Inset shows false color infrared thermograph of a roof on a sunny day; the white surfaces (colored blue in the thermograph) have been coated with an elastomer to reduce solar loading and have a surface temperature of approximately 60 °F (16 °C); the gray surfaces (colored red/white in the thermogram) are a standard asphalt (bitumen) coating and have a surface temperature of approximately 160 °F (71 °C).

Infrared and thermal testing refer to passive thermographic inspection techniques, a class of nondestructive testing designated by the American Society for Nondestructive Testing (ASNT). [1] Infrared thermography is the science of measuring and mapping surface temperatures.

Contents

"Infrared thermography, a nondestructive, remote sensing technique, has proved to be an effective, convenient, and economical method of testing concrete. It can detect internal voids, delaminations, and cracks in concrete structures such as bridge decks, highway pavements, garage floors, parking lot pavements, and building walls. As a testing technique, some of its most important qualities are that (1) it is accurate; (2) it is repeatable; (3) it need not inconvenience the public; and (4) it is economical." [2]

Principles

There are three ways of transferring thermal energy:

  1. conduction
  2. convection
  3. radiation

All objects emit electromagnetic radiation of a wavelength dependent on the object's temperature. The wavelength of the radiation is inversely proportional to the temperature. According to thermodynamics, emitted energy will flow from warmer to cooler areas, and the rate of energy transfer will vary according to the efficiency of the heat transfer processes and the insulating effects of the material through which energy is flowing. In principle, a targeted object or feature will have different thermal properties than its surroundings; for instance, a buried metallic pipe conducts heat more readily than the surrounding soil, so if the fluid it is carrying is at a different temperature than the ambient conditions, the pipe will be visible to a thermal imaging sensor without having to perform an excavation to locate the pipe. [3]

Various types of construction materials have different insulating abilities. In addition, differing types of pipeline defects have different insulating values and/or vary in the magnitude of energy supplied. Because of the potential heterogeneities in the surrounding pipe (i.e., different types of soils), it can be difficult to distinguish targeted objects from background noise. [3]

Sensitivity

An infrared thermographic scanning system can measure and view temperature patterns based upon temperature differences as small as a few hundredths of a degree Celsius. Infrared thermographic testing may be performed during day or night, depending on environmental conditions and the desired results. [1]

In practice

This CAT S60 smartphone is equipped with a thermographic camera from FLIR Systems. CAT S60 phone with Flir thermal camera (26089237983).jpg
This CAT S60 smartphone is equipped with a thermographic camera from FLIR Systems.

In infrared thermography, thermal radiation is detected and measured with infrared imagers, also known as thermographic cameras or radiometers. The imagers contain an infrared detector that converts the emitted radiation into electrical signals that are displayed on a color or black and white computer display monitor.

After the thermal data is processed, it can be displayed on a monitor in multiple shades of gray scale or color. The colors displayed on the thermogram are arbitrarily set by the Thermographer to best illustrate the infrared data being analyzed. [4]

Sample applications

False-color thermograph of electrical equipment, illustrating "hot spot" Electrical fault.jpg
False-color thermograph of electrical equipment, illustrating "hot spot"

A typical application for regularly available IR Thermographic equipment is looking for "hot spots" in electrical equipment, which illustrates high resistance areas in electrical circuits. These "hot spots" are usually measured in the range of 40 °C to 150 °C (70 to 270 °F) above ambient temperatures.

When engineers use proprietary systems to locate subsurface targets such as underground storage tanks (USTs), pipelines, pipeline leaks and their plumes, and hidden tunnels, their locations are identified by temperature patterns typically in the range of 0.01 °C to 1 °C above or below ambient temperatures.

Roofing

In this roofing investigation application, infrared thermographic data was collected during daytime hours, on both sunny and rainy days. This data collection time allowed for solar heating of the roof, and any entrapped water within the roofing system, during the daylight hours. IR data was observed until the roof had sufficiently warmed to allow detection of the entrapped wet areas because of their ability to collect and store more heat than the dry insulated areas. The wet areas would also transfer the heat at a faster rate than the dry insulated roof areas. At this point in time, the wet areas showed up as warmer roof surface temperatures than the surrounding dry background areas of the roof.

During the rainy day, with minimum solar loading, any entrapped leak plumes would become evident because of their cooler temperature as compared to the dry roof areas

Pipeline testing

An infrared thermographic scanning system measures surface temperatures only. But the surface temperatures that are measured on the surface of the ground, above a buried pipeline, are, to a great extent, dependent upon the subsurface conditions.

Good solid backfill should have the least resistance to conduction of energy and the convection gas radiation effects should be negligible. The various types of problems associated with soil erosion and poor backfill surrounding buried pipelines increase the insulating ability of the soil, by reducing the energy conduction properties, without substantially increasing the convection effects. This is because dead air spaces do not allow the formation of convection currents.

In order to have an energy flow, there must be an energy source. Since buried pipeline testing can involve large areas, the heat source has to be low cost and able to give the ground surface above the pipeline an even distribution of heat. The sun fulfills both of these requirements. The ground surface reacts, storing or transmitting the energy received.

For pipelines carrying fluids at temperatures above or below the ambient ground temperatures (i.e., steam, oil, liquefied gases, or chemicals), an alternative is to use the heat sinking ability of the earth to draw heat from the pipeline under test. The crucial point to remember is that the energy must be flowing through the ground and fluids.

Ground cover must be evaluated for temperature differentials (i.e., anomalies such as high grass or surface debris), as to how it may affect the surface condition of the test area. Of the three methods of energy transfer, radiation is the method that has the most profound effect upon the ability of the surface to transfer energy. The ability of a material to radiate energy is measured by the emissivity of the material. This is defined as the ability of the material to release energy as compared to a perfect blackbody radiator. This is strictly a surface property. It normally exhibits itself in higher values for rough surfaces and lower values for smooth surfaces. For example, rough concrete may have an emissivity of 0.95 while a shiny piece of tinfoil may have an emissivity of only 0.05. In practical terms, this means that when looking at large areas of ground cover, the engineer in charge of testing must be aware of differing surface textures caused by such things as broom roughed spots, tire rubber tracks, oil spots, loose sand and dirt on the surface and the height of grassy areas.

Standards

International Organization for Standardization (ISO)

Related Research Articles

<span class="mw-page-title-main">Infrared</span> Form of electromagnetic radiation

Infrared is electromagnetic radiation (EMR) with wavelengths longer than those of visible light and shorter than radio waves. It is therefore invisible to the human eye. IR is generally understood to encompass wavelengths from around 1 millimeter (300 GHz) to the nominal red edge of the visible spectrum, around 700 nanometers (430 THz). IR is commonly divided between longer-wavelength thermal infrared that is emitted from terrestrial sources and shorter-wavelength near-infrared that is part of the solar spectrum. Longer IR wavelengths (30–100 μm) are sometimes included as part of the terahertz radiation range. Almost all black-body radiation from objects near room temperature is at infrared wavelengths. As a form of electromagnetic radiation, IR propagates energy and momentum, exerts radiation pressure, and has properties corresponding to both those of a wave and of a particle, the photon.

<span class="mw-page-title-main">Passive solar building design</span> Architectural engineering that uses the Suns heat without electric or mechanical systems

In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.

<span class="mw-page-title-main">Thermal insulation</span> Minimization of heat transfer

Thermal insulation is the reduction of heat transfer between objects in thermal contact or in range of radiative influence. Thermal insulation can be achieved with specially engineered methods or processes, as well as with suitable object shapes and materials.

<span class="mw-page-title-main">Heat transfer</span> Transport of thermal energy in physical systems

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy (heat) between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes. Engineers also consider the transfer of mass of differing chemical species, either cold or hot, to achieve heat transfer. While these mechanisms have distinct characteristics, they often occur simultaneously in the same system.

<span class="mw-page-title-main">Thermal radiation</span> Electromagnetic radiation generated by the thermal motion of particles

Thermal radiation is electromagnetic radiation generated by the thermal motion of particles in matter. Thermal radiation is generated when heat from the movement of charges in the material is converted to electromagnetic radiation. All matter with a temperature greater than absolute zero emits thermal radiation. At room temperature, most of the emission is in the infrared (IR) spectrum. Particle motion results in charge-acceleration or dipole oscillation which produces electromagnetic radiation.

<span class="mw-page-title-main">Thermographic camera</span> Imaging device using infrared radiation

A thermographic camera is a device that creates an image using infrared (IR) radiation, similar to a normal camera that forms an image using visible light. Instead of the 400–700 nanometre (nm) range of the visible light camera, infrared cameras are sensitive to wavelengths from about 1,000 nm to about 14,000 nm (14 μm). The practice of capturing and analyzing the data they provide is called thermography.

<i>R</i>-value (insulation) Measure of how well an object, per unit of area, resists conductive flow of heat

In the context of construction, the R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive flow of heat. R-value is the temperature difference per unit of heat flux needed to sustain one unit of heat flux between the warmer surface and colder surface of a barrier under steady-state conditions. The measure is therefore equally relevant for lowering energy bills for heating in the winter, for cooling in the summer, and for general comfort.

<span class="mw-page-title-main">Thermography</span> Use of thermograms to study heat distribution in structures or regions

Infrared thermography (IRT), thermal video and/or thermal imaging, is a process where a thermal camera captures and creates an image of an object by using infrared radiation emitted from the object in a process, which are examples of infrared imaging science. Thermographic cameras usually detect radiation in the long-infrared range of the electromagnetic spectrum and produce images of that radiation, called thermograms. Since infrared radiation is emitted by all objects with a temperature above absolute zero according to the black body radiation law, thermography makes it possible to see one's environment with or without visible illumination. The amount of radiation emitted by an object increases with temperature; therefore, thermography allows one to see variations in temperature. When viewed through a thermal imaging camera, warm objects stand out well against cooler backgrounds; humans and other warm-blooded animals become easily visible against the environment, day or night. As a result, thermography is particularly useful to the military and other users of surveillance cameras.

<span class="mw-page-title-main">Radiant barrier</span>

A radiant barrier is a type of building material that reflects thermal radiation and reduces heat transfer. Because thermal energy is also transferred by conduction and convection, in addition to radiation, radiant barriers are often supplemented with thermal insulation that slows down heat transfer by conduction or convection.

<span class="mw-page-title-main">Solar thermal collector</span> Device that collects heat

A solar thermal collector collects heat by absorbing sunlight. The term "solar collector" commonly refers to a device for solar hot water heating, but may refer to large power generating installations such as solar parabolic troughs and solar towers or non water heating devices such as solar cooker, solar air heaters.

<span class="mw-page-title-main">Infrared thermometer</span> Thermometer which infers temperature by measuring infrared energy emission

An infrared thermometer is a thermometer which infers temperature from a portion of the thermal radiation sometimes called black-body radiation emitted by the object being measured. They are sometimes called laser thermometers as a laser is used to help aim the thermometer, or non-contact thermometers or temperature guns, to describe the device's ability to measure temperature from a distance. By knowing the amount of infrared energy emitted by the object and its emissivity, the object's temperature can often be determined within a certain range of its actual temperature. Infrared thermometers are a subset of devices known as "thermal radiation thermometers".

<span class="mw-page-title-main">Electric heating</span> Process in which electrical energy is converted to heat

Electric heating is a process in which electrical energy is converted directly to heat energy. Common applications include space heating, cooking, water heating and industrial processes. An electric heater is an electrical device that converts an electric current into heat. The heating element inside every electric heater is an electrical resistor, and works on the principle of Joule heating: an electric current passing through a resistor will convert that electrical energy into heat energy. Most modern electric heating devices use nichrome wire as the active element; the heating element, depicted on the right, uses nichrome wire supported by ceramic insulators.

Thermal transmittance is the rate of transfer of heat through matter. The thermal transmittance of a material or an assembly is expressed as a U-value. The thermal insulance of a structure is the reciprocal of its thermal transmittance.

<span class="mw-page-title-main">Building insulation</span> Material to reduce heat transfer in structures

Building insulation is material used in a building to reduce the flow of thermal energy. While the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an insulation material will be chosen for its ability to perform several of these functions at once.

<span class="mw-page-title-main">Thermal bridge</span>

A thermal bridge, also called a cold bridge, heat bridge, or thermal bypass, is an area or component of an object which has higher thermal conductivity than the surrounding materials, creating a path of least resistance for heat transfer. Thermal bridges result in an overall reduction in thermal resistance of the object. The term is frequently discussed in the context of a building's thermal envelope where thermal bridges result in heat transfer into or out of conditioned space.

<span class="mw-page-title-main">Thermal effusivity</span> Ability of a material to exchange thermal energy with surroundings

In thermodynamics, a material's thermal effusivity, also known as thermal responsivity, is a measure of its ability to exchange thermal energy with its surroundings. It is defined as the square root of the product of the material's thermal conductivity and its volumetric heat capacity or as the ratio of thermal conductivity to the square root of thermal diffusivity.

Thermographic inspection refers to the nondestructive testing (NDT) of parts, materials or systems through the imaging of the temperature fields, gradients and/or patterns ("thermograms") at the object's surface. It is distinguished from medical thermography by the subjects being examined: thermographic inspection generally examines inanimate objects, while medical thermography generally examines living organisms. Generally, thermographic inspection is performed using an infrared sensor.

Infrared vision is the capability of biological or artificial systems to detect infrared radiation. The terms thermal vision and thermal imaging, are also commonly used in this context since infrared emissions from a body are directly related to their temperature: hotter objects emit more energy in the infrared spectrum than colder ones.

<span class="mw-page-title-main">Radiant heating and cooling</span> Category of HVAC technologies

Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", "embedded surface systems", "thermally active building systems", and infrared heaters. According to some definitions, a technology is only included in this category if radiation comprises more than 50% of its heat exchange with the environment; therefore technologies such as radiators and chilled beams are usually not considered radiant heating or cooling. Within this category, it is practical to distinguish between high temperature radiant heating, and radiant heating or cooling with more moderate source temperatures. This article mainly addresses radiant heating and cooling with moderate source temperatures, used to heat or cool indoor environments. Moderate temperature radiant heating and cooling is usually composed of relatively large surfaces that are internally heated or cooled using hydronic or electrical sources. For high temperature indoor or outdoor radiant heating, see: Infrared heater. For snow melt applications see: Snowmelt system.

Active thermography is an advanced nondestructive testing procedure, which uses a thermography measurement of a tested material thermal response after its external excitation. This principle can be used also for non-contact infrared non-destructive testing (IRNDT) of materials.

References

  1. 1 2 Jackson, Charles N.; Sherlock, Charles N.; Moore, Patrick O., eds. (1998). Nondestructive Testing Handbook. Vol. 1: Leak Testing (Third ed.). The American Society for Nondestructive Testing. p. 519. ISBN   978-1-57117-071-2.
  2. Weil, Gary J. (2004). "15: Infrared Thermographic Techniques". In Malhotra, V. Mohan; Carino, Nicholas J. (eds.). Handbook on Nondestructive Testing of Concrete (Second ed.). West Conshohocken, Pennsylvania: CRC Press / ASTM International. p. 15-1. ISBN   0-8031-2099-0 . Retrieved 16 March 2021.
  3. 1 2 Santulli, Carlo. IR Thermography for the Detection of Buried Objects: A Short Review (PDF) (Report). Retrieved 16 March 2021.
  4. "Thermal Scanner". Turing Video was founded in the heart of Silicon Valley in 2017.