Kendrick extrication device

Last updated
Diagram of a Kendrick extrication device Kendric Estrcation Device.jpg
Diagram of a Kendrick extrication device

A Kendrick extrication device (KED) is a device used in extrication of victims of traffic collisions from motor vehicles. Commonly carried on ambulances, a KED is typically used by an emergency medical technician, paramedic, or another first responder. It was originally designed for extrication of race car drivers. [1] Typically used in conjunction with a cervical collar, a KED is a semi-rigid brace that secures the head, neck and torso in an anatomically neutral position. Its use is claimed to reduce the possibility of additional injuries to these regions during extrication, although its value has been questioned, as there is a lack of evidence to support its use. The original KED was designed by Richard Kendrick in 1978. [2]

Contents

Description

Typically there are two head straps, three torso straps, and two legs straps which are used to adequately secure the KED to the victim. Unlike a long spine board or litter, the KED uses a series of wooden or polymer bars in a nylon jacket, allowing the responders to immobilize the neck and upper spine and remove the victim from the vehicle or other confined space. Although a KED can also be used to immobilize infants and children, it is preferable to use specifically designed pediatric immobilization devices whenever possible. If a KED is used to immobilize an infant or child, appropriate padding must be used to ensure complete immobilization in a manner that does not obscure the thorax and abdomen, thereby preventing continued assessment of these vital areas.

Application

The device can be quickly and easily inserted into the seat of a vehicle by a single rescuer, allows access to the airway and conforms to any body size. [3] A KED is typically used only on hemodynamically stable victims; unstable victims are extricated using rapid extrication techniques without the prior application of the KED.

Once the KED is slid into position, it is secured to the victim with straps in order to prevent movement. The first strap that is secured is the middle torso strap. According to the KED users' manual securing this strap secures the greatest area of the device and therefore provides the greatest stability while securing the rest of the device. Next the bottom torso strap is secured, however the top torso strap is not secured until just prior to moving the patient to the long spine board. This is to allow the patient to breathe easily while the rest of the device is secured. Following the bottom torso strap the leg straps are secured. These may be applied in a "criss-cross" fashion (according to the KED users' manual this is the most commonly used method), or applied by securing them to their respective sides. If there is any evidence of a groin injury the "criss-cross" method cannot be used. Following application of the leg straps the void between the head and device is padded as needed and the head is secured. Finally, just prior to moving the patient to a long spine board the top strap is secured. [4] Some schools teach this order by remembering phrases such as "My Baby Looks Hot Tonight", where the beginning of each word stands for Middle torso strap, Bottom torso strap, Leg straps, Head strap and Top torso strap.[ citation needed ]

The head pad can bring the head too far forward for the side panels to fully immobilize it. Care must be taken to secure the head properly to maintain neutral immobilization. If the head is too far forward, the head is brought back to meet the KED unless crepitus, pain or resistance is met. If these symptoms are present, the head is immobilized in the position found.

There has been debate surrounding the exact order of applying the torso straps, with some saying that the order does not matter as long as the torso is secured before the head. The KED users' manual is sometimes used in these debates: it states the reason the top strap is last is a function of breathing and not the process of immobilization itself. [4]

Value

There is controversy about whether the use of a KED is actually appropriate in prehospital care. [1] A 2015 article in the Journal of Paramedic Practice said that although the device has been used since the 1970s, its "overall appropriateness in patient care should be viewed with caution" and there is a "lack of evidence to support its use". [1] A 1988 article in the Canadian Medical Association Journal said the device had "yet to be evaluated for its immobilization of the cervical spine" and that "the role and performance of the device in transferring patients by road or air ... must be addressed". [3]

Rapid extrication without a KED

During rapid extrication, the patient is not immobilized by a KED, but rather taken directly out of the car onto a back board. Reasons for using this technique include:

Related Research Articles

<span class="mw-page-title-main">Whiplash (medicine)</span> Injuries to the neck

Whiplash, whose formal term is whiplash associated disorders (WAD), is a range of injuries to the neck caused by or related to a sudden distortion of the neck associated with extension, although the exact injury mechanisms remain unknown. The term "whiplash" is a colloquialism. "Cervical acceleration–deceleration" (CAD) describes the mechanism of the injury, while WAD describes the subsequent injuries and symptoms.

<span class="mw-page-title-main">Stretcher</span> Equipment for moving patients in need of medical care

A stretcher, gurney, litter, or pram is an apparatus used for moving patients who require medical care. A basic type must be carried by two or more people. A wheeled stretcher is often equipped with variable height frames, wheels, tracks, or skids.

<span class="mw-page-title-main">Splint (medicine)</span> Medical restraint to keep body part in place

A splint is defined as "a rigid or flexible device that maintains in position a displaced or movable part; also used to keep in place and protect an injured part" or as "a rigid or flexible material used to protect, immobilize, or restrict motion in a part". Splints can be used for injuries that are not severe enough to immobilize the entire injured structure of the body. For instance, a splint can be used for certain fractures, soft tissue sprains, tendon injuries, or injuries awaiting orthopedic treatment. A splint may be static, not allowing motion, or dynamic, allowing controlled motion. Splints can also be used to relieve pain in damaged joints. Splints are quick and easy to apply and do not require a plastering technique. Splints are often made out of some kind of flexible material and a firm pole-like structure for stability. They often buckle or Velcro together.

<span class="mw-page-title-main">Orthopedic cast</span> Medical aid for the treatment of bone fractures

An orthopedic cast, or simply cast, is a shell, frequently made from plaster or fiberglass, that encases a limb to stabilize and hold anatomical structures—most often a broken bone, in place until healing is confirmed. It is similar in function to a splint.

<span class="mw-page-title-main">Spinal board</span> Device used in pre-hospital trauma care

A spinal board, is a patient handling device used primarily in pre-hospital trauma care. It is designed to provide rigid support during movement of a person with suspected spinal or limb injuries. They are most commonly used by ambulance staff, as well as lifeguards and ski patrollers. Historically, backboards were also used in an attempt to "improve the posture" of young people, especially girls.

<span class="mw-page-title-main">Vacuum mattress</span> Device used for patient immobilisation

A vacuum mattress, or vacmat, is a medical device used for the immobilisation of patients, especially in case of a vertebra, pelvis or limb trauma. It is also used for manual transportation of patients for short distances. It was invented by Loed and Haederlé, who called it "shell" mattress.

<span class="mw-page-title-main">Casualty lifting</span> Procedures to lift someone onto a stretcher

Casualty lifting is the first step of casualty movement, an early aspect of emergency medical care. It is the procedure used to put the casualty on a stretcher.

<span class="mw-page-title-main">Vehicle extrication</span> Process of removing a person trapped in a vehicle

Vehicle extrication is the process of removing a patient from a vehicle who has been involved in a motor vehicle collision. Patients who have not already exited a crashed vehicle may be medically or physically trapped and may be pinned by wreckage or simply unable to exit a vehicle.

<span class="mw-page-title-main">Cervical collar</span> Medical device used to support a neck

A cervical collar, also known as a neck brace, is a medical device used to support and immobilize a person's neck. It is also applied by emergency personnel to those who have had traumatic head or neck injuries, although they should not be routinely used in prehospital care. They can also be used to treat chronic medical conditions.

<span class="mw-page-title-main">Scoop stretcher</span> Device used for moving injured people

The scoop stretcher is a device used specifically for moving injured people. It is ideal for carrying casualties with possible spinal injuries.

<span class="mw-page-title-main">Cervical fracture</span> Medical condition

A cervical fracture, commonly called a broken neck, is a fracture of any of the seven cervical vertebrae in the neck. Examples of common causes in humans are traffic collisions and diving into shallow water. Abnormal movement of neck bones or pieces of bone can cause a spinal cord injury, resulting in loss of sensation, paralysis, or usually death soon thereafter, primarily via compromising neurological supply to the respiratory muscles and innervation to the heart.

Outdoor emergency care (OEC) was first developed by the National Ski Patrol in the 1980s for certification in first aid, and other pre-hospital care and treatment for possible injuries in non-urban settings. Outdoor emergency care technicians provide care at ski resorts, wilderness settings, white-water excursions, mountain bike events, and in many other outdoor environments.

A traction splint most commonly refers to a splinting device that uses straps attaching over the pelvis or hip as an anchor, a metal rod(s) to mimic normal bone stability and limb length, and a mechanical device to apply traction to the limb.

<span class="mw-page-title-main">Litter (rescue basket)</span> Basket-like stretcher device used to carry injured people

A litter is a stretcher designed to be used where there are physical obstacles that impair movement, including other hazards such as, in confined spaces, on slopes or uneven terrain, or in densely forested areas. Typically it is shaped to accommodate an adult in a face up position and it is used in search and rescue operations. The person is strapped into the basket, making safe evacuation possible. The person generally is further protected by a cervical collar and sometimes a long spine board, so as to immobilize the person and prevent further injury.

<span class="mw-page-title-main">Milwaukee brace</span>

The Milwaukee brace, also known as a cervico-thoraco-lumbo-sacral orthosis or CTLSO, is a back brace most often used in the treatment of spinal curvatures in children but also, more rarely, in adults to prevent collapse of the spine and associated pain and deformity. It is a full-torso brace that extends from the pelvis to the base of the skull. It was originally designed by Blount and Schmidt in 1946 for postoperative care when surgery required long periods of immobilization.

Grady straps are a specific strapping configuration used in full body spinal immobilization.

<span class="mw-page-title-main">Helmet removal (sports)</span> Emergency medical procedure

In sports medicine, helmet removal is the practice of removing the helmet of someone who has just experienced a sports injury in order to better facilitate first aid. Obvious causes include head and neck injury, or both, with no immediate means of excluding neck injury in the athlete who may be unable to give a history.

<span class="mw-page-title-main">Airtraq</span> Device used for tracheal intubation

Airtraq is a fibreoptic intubation device used for indirect tracheal intubation in difficult airway situations. It is designed to enable a view of the glottic opening without aligning the oral with the pharyngeal, and laryngeal axes as an advantage over direct endotracheal intubation and allows for intubation with minimal head manipulation and positioning.

<span class="mw-page-title-main">Spinal precautions</span> Efforts to prevent movement of the spine in those with a risk of a spine injury

Spinal precautions, also known as spinal immobilization and spinal motion restriction, are efforts to prevent movement of the spine in those with a risk of a spine injury. This is done as an effort to prevent injury to the spinal cord. It is estimated that 2% of people with blunt trauma will have a spine injury.

<span class="mw-page-title-main">Basic airway management</span>

Basic airway management is a concept and set of medical procedures performed to prevent and treat airway obstruction and allow for adequate ventilation to a patient's lungs. This is accomplished by clearing or preventing obstructions of airways. Airway obstructions can occur in both conscious and unconscious individuals. They can also be partial or complete. Airway obstruction is commonly caused by the tongue, the airways itself, foreign bodies or materials from the body itself, such as blood or vomit. Contrary to advanced airway management, basic airway management technique do not rely on the use of invasive medical equipment and can be performed with less training. Medical equipment commonly used includes oropharyngeal airway, nasopharyngeal airway, bag valve mask, and pocket mask. Airway management is a primary consideration in cardiopulmonary resuscitation, anaesthesia, emergency medicine, intensive care medicine and first aid.

References

  1. 1 2 3 Brown, Nick (2015). "Should the Kendrick Extrication Device have a place in pre-hospital care?". Journal of Paramedic Practice. 7 (6): 300–304. doi:10.12968/jpar.2015.7.6.300. ISSN   1759-1376.
  2. Kendrick, Richard L. (July 8, 1980). "U.S. Patent number 4,211,218: Spinal restraint device" via Google patents.
  3. 1 2 Karbi, OA; Caspari, DA; Tator, CH (1988). "Extrication, immobilization and radiologic investigation of patients with cervical spine injuries". Canadian Medical Association Journal . 139 (7): 617–21. PMC   1268249 . PMID   3046734.
  4. 1 2 KED User's Manual, 2001, p. 11
  5. "Rapid Extrication" (PDF). New York State Department of Health. Retrieved 2020-12-18.