Local maximum intensity projection

Last updated

In scientific visualization, a local maximum intensity projection (LMIP, Local MIP) or Closest Vessel Projection (CVP) [1] is a volume rendering method for 3D data, that is proposed as an improvement to the maximum intensity projection (MIP). Where the MIP projects the maximum intensity that falls in the way of parallel rays traced from the viewpoint, LMIP takes the first local maximum value, that is above a certain threshold. [2]

Local maximum intensity projection has been proposed as in visualization of data from computerized tomography and magnetic resonance imaging. [2] It also can be used to extract a 3-dimensional vascular network from the data from a knife-edge scanning microscope at a significantly reduced computational demand (65% reduced). [3]

Footnotes

  1. Preim, Bernhard. Visualization in Medicine: Theory, Algorithms, and Applications. The Morgan Kaufmann Series in Computer Graphics.
  2. 1 2 Sato Y.; Shiraga N.; Nakajima S.; Tamura S. & Kikinis R. (1998). "Local Maximum Intensity Projection (LMIP): A New Rendering Method for Vascular Visualization" (PDF). Journal of Computer Assisted Tomography. 22 (6): 912–917. doi:10.1097/00004728-199811000-00014. PMID   9843232.
  3. Han, Donghyeop; Keyser, John & Choe, Yoonsuck. "A LOCAL MAXIMUM INTENSITY PROJECTION TRACING OF VASCULATURE IN KNIFE-EDGE SCANNING MICROSCOPE VOLUME DATA" (PDF). Texas A&M University. Retrieved September 1, 2012.


Related Research Articles

CT scan Medical imaging procedure using X-rays to produce cross-sectional images

A CT scan or computed tomography scan is a medical imaging technique that uses computer-processed combinations of multiple X-ray measurements taken from different angles to produce tomographic (cross-sectional) images of a body, allowing the user to see inside the body without cutting. The personnel that perform CT scans are called radiographers or radiologic technologists.

Tomography Imaging by sections or sectioning using a penetrative wave

Tomography is imaging by sections or sectioning through the use of any kind of penetrating wave. The method is used in radiology, archaeology, biology, atmospheric science, geophysics, oceanography, plasma physics, materials science, astrophysics, quantum information, and other areas of science. The word tomography is derived from Ancient Greek τόμος tomos, "slice, section" and γράφω graphō, "to write" or, in this context as well, " to describe." A device used in tomography is called a tomograph, while the image produced is a tomogram.

Scientific visualization Field of computer graphics concerned with presenting scientific data visually

Scientific visualization is an interdisciplinary branch of science concerned with the visualization of scientific phenomena. It is also considered a subset of computer graphics, a branch of computer science. The purpose of scientific visualization is to graphically illustrate scientific data to enable scientists to understand, illustrate, and glean insight from their data.

Anisotropic filtering Method of enhancing the image quality of textures on surfaces of computer graphics

In 3D computer graphics, anisotropic filtering is a method of enhancing the image quality of textures on surfaces of computer graphics that are at oblique viewing angles with respect to the camera where the projection of the texture appears to be non-orthogonal.

Volume rendering 3D rendering techniques

In scientific visualization and computer graphics, volume rendering is a set of techniques used to display a 2D projection of a 3D discretely sampled data set, typically a 3D scalar field.

Iterative reconstruction

Iterative reconstruction refers to iterative algorithms used to reconstruct 2D and 3D images in certain imaging techniques. For example, in computed tomography an image must be reconstructed from projections of an object. Here, iterative reconstruction techniques are usually a better, but computationally more expensive alternative to the common filtered back projection (FBP) method, which directly calculates the image in a single reconstruction step. In recent research works, scientists have shown that extremely fast computations and massive parallelism is possible for iterative reconstruction, which makes iterative reconstruction practical for commercialization.

Confocal microscopy

Confocal microscopy, most frequently confocal laser scanning microscopy (CLSM) or laser confocal scanning microscopy (LCSM), is an optical imaging technique for increasing optical resolution and contrast of a micrograph by means of using a spatial pinhole to block out-of-focus light in image formation. Capturing multiple two-dimensional images at different depths in a sample enables the reconstruction of three-dimensional structures within an object. This technique is used extensively in the scientific and industrial communities and typical applications are in life sciences, semiconductor inspection and materials science.

OsiriX

OsiriX is an image processing application for Mac dedicated to DICOM images produced by equipment. OsiriX is complementary to existing viewers, in particular to nuclear medicine viewers. It can also read many other file formats: TIFF, JPEG, PDF, AVI, MPEG and QuickTime. It is fully compliant with the DICOM standard for image communication and image file formats. OsiriX is able to receive images transferred by DICOM communication protocol from any PACS or medical imaging modality.


Computed tomography laser mammography (CTLM) is the trademark of Imaging Diagnostic Systems, Inc. for its optical tomographic technique for female breast imaging.

Image stitching or photo stitching is the process of combining multiple photographic images with overlapping fields of view to produce a segmented panorama or high-resolution image. Commonly performed through the use of computer software, most approaches to image stitching require nearly exact overlaps between images and identical exposures to produce seamless results, although some stitching algorithms actually benefit from differently exposed images by doing high-dynamic-range imaging in regions of overlap. Some digital cameras can stitch their photos internally.

Magnetic resonance angiography Group of techniques based on magnetic resonance imaging (MRI) to image blood vessels.

Magnetic resonance angiography (MRA) is a group of techniques based on magnetic resonance imaging (MRI) to image blood vessels. Magnetic resonance angiography is used to generate images of arteries in order to evaluate them for stenosis, occlusions, aneurysms or other abnormalities. MRA is often used to evaluate the arteries of the neck and brain, the thoracic and abdominal aorta, the renal arteries, and the legs.

Maximum intensity projection

In scientific visualization, a maximum intensity projection (MIP) is a method for 3D data that projects in the visualization plane the voxels with maximum intensity that fall in the way of parallel rays traced from the viewpoint to the plane of projection. This implies that two MIP renderings from opposite viewpoints are symmetrical images if they are rendered using orthographic projection.

Electron tomography a tomography technique for obtaining detailed 3D structures of sub-cellular macro-molecular objects

Electron tomography (ET) is a tomography technique for obtaining detailed 3D structures of sub-cellular macro-molecular objects. Electron tomography is an extension of traditional transmission electron microscopy and uses a transmission electron microscope to collect the data. In the process, a beam of electrons is passed through the sample at incremental degrees of rotation around the center of the target sample. This information is collected and used to assemble a three-dimensional image of the target. For biological applications, the typical resolution of ET systems are in the 5–20 nm range, suitable for examining supra-molecular multi-protein structures, although not the secondary and tertiary structure of an individual protein or polypeptide.

The Knife-Edge Scanning Microscope (KESM) was invented and patented in the late 1990s by Bruce McCormick at Texas A&M University. The microscope is intended to produce high-resolution data sets in order to reconstruct 3D cellular structures.

Voreen

Voreen is an open-source volume visualization library and development platform. Through the use of GPU-based volume rendering techniques it allows high frame rates on standard graphics hardware to support interactive volume exploration.

Industrial computed tomography Computer-aided tomographic process

Industrial computed tomography (CT) scanning is any computer-aided tomographic process, usually X-ray computed tomography, that uses irradiation to produce three-dimensional internal and external representations of a scanned object. Industrial CT scanning has been used in many areas of industry for internal inspection of components. Some of the key uses for industrial CT scanning have been flaw detection, failure analysis, metrology, assembly analysis and reverse engineering applications. Just as in medical imaging, industrial imaging includes both nontomographic radiography and computed tomographic radiography.

Ambivu 3D Workstation

AmbiVU 3D is a commercial medical imaging workstation that is compliant with the DICOM imaging and communications format. It is designed for high speed volume rendering of MRI, CT, PET, PET-CT and dual PET-CT datasets.

Cone beam computed tomography

Cone beam computed tomography is a medical imaging technique consisting of X-ray computed tomography where the X-rays are divergent, forming a cone.

Amira (software)

Amira is a software platform for 3D and 4D data visualization, processing, and analysis. It is being actively developed by Thermo Fisher Scientific in collaboration with the Zuse Institute Berlin (ZIB), and commercially distributed by Thermo Fisher Scientific.

Minimum intensity projection

In scientific visualization, minimum intensity projection (MinIP) is a method for visualization of structures with low intensity in a specific volume. A two-dimensional image of a selected volume is generated where each pixel is represented by displaying the lowest attenuation value in each voxel.