Loop heat pipe

Last updated

A loop heat pipe (LHP) is a two-phase heat transfer device that uses capillary action to remove heat from a source and passively move it to a condenser or radiator. LHPs are similar to heat pipes but have the advantage of being able to provide reliable operation over long distance and the ability to operate against gravity. They can transport a large heat load over a long distance with a small temperature difference. [1] [2] Different designs of LHPs ranging from powerful, large size LHPs to miniature LHPs (micro-loop heat pipe) have been developed and successfully employed in a wide sphere of applications both ground and space-based applications.

Contents

Construction

The most common coolants used in LHPs are anhydrous ammonia and propylene. [3] LHPs are made by controlling the volumes of the reservoir carefully, condenser and vapor and liquid lines so that liquid is always available to the wick. The reservoir volume and fluid charge are set so that there is always fluid in the reservoir even if the condenser and vapor and liquid lines are completely filled.

Generally small pore size and large capillary pumping capability are necessary in a wick. There must be a balance in the wick pumping capability and the wick permeability when designing a heat pipe or loop heat pipe.[ citation needed ]

Mechanism

In a loop heat pipe, first the heat enters the evaporator and vaporizes the working fluid at the wick outer surface. The vapor then flows down the system of grooves and then goes to the evaporator and the vapor line towards the condenser, where it condenses as heat is removed by the radiator. The two-phase reservoir (or compensation chamber) at the end of the evaporator is specifically designed to operate at a slightly lower temperature than the evaporator (and the condenser). The lower saturation pressure in the reservoir draws the condensate through the condenser and liquid return line. The fluid then flows into a central pipe where it feeds the wick. A secondary wick hydraulically links the reservoir and the primary wick.[ citation needed ]

Motivation: limitations of heat pipes

Loop heat pipes overcome some of the shortcomings of conventional heat pipes, which while being excellent heat transfer devices are mainly confined to transferring relatively small heat loads over relatively short distances when the evaporator and condenser are at same horizontal level. This limitation on the part of heat pipes is mainly related to the major pressure losses associated with the liquid flow through the porous structure, present along the entire length of the heat pipe, and viscous interaction between the vapor and liquid phases, also called entrainment losses. For the applications involving transfer of large heat loads over long distances, the thermal performance of the heat pipes is badly affected by increase in these losses. For the same reason conventional heat pipes are very sensitive to the change in orientation in gravitational field. For the unfavorable slopes in an evaporator-above-condenser configuration, the pressure losses due to the mass forces in gravity field adds to the total pressure losses and further affect the efficiency of the heat transfer process.

As a result of these limitations, different solutions involving structural modifications to the conventional heat pipe have been proposed. Some of these modifications incorporate arterial tubes with considerably low hydraulic resistance for liquid return to the heat source (arterial heat pipes), while others provide spatial separation of the vapor and liquid phases of the working fluid at the transportation section (separated line heat pipes).

Though these new forms of heat pipes are able to transfer significant heat flows and can increase heat transport length, they remain very sensitive to spatial orientation relative to gravity. To extend the functional possibilities of two-phase systems to applications involving otherwise inoperable slopes in gravity, the advantages provided by the spatial separation of the transportation line and the usage of non-capillary arteries are combined in a loop scheme. This scheme allows heat pipes to be created with higher heat transfer characteristics while maintaining normal operation in any directional orientation. The loop scheme forms the basis of the physical concept of Two-Phase Loops (TPLs).

Origins

Loop heat pipes were patented in USSR in 1974 by Yury F. Gerasimov and Yury F. Maydanik (Inventor's certificate No. 449213), all of the former Soviet Union. The patent for LHPs was filed in the USA in 1982 (Patent № 4515209).

Applications

The first space application occurred aboard a Russian spacecraft in 1989. LHPs are now commonly used in space aboard satellites including; Russian Granat, Obzor spacecraft, Boeing's (Hughes) HS 702 communication satellites, Chinese FY-1C meteorological satellite, NASA's ICESat. [4]

LHPs were demonstrated on the NASA space shuttle in 1997 with STS-83 and STS-94.[ citation needed ]

Loop heat pipes are important parts of systems for cooling electronic components.

See also

Related Research Articles

<span class="mw-page-title-main">Heat exchanger</span> Equipment used to transfer heat between fluids

A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact. They are widely used in space heating, refrigeration, air conditioning, power stations, chemical plants, petrochemical plants, petroleum refineries, natural-gas processing, and sewage treatment. The classic example of a heat exchanger is found in an internal combustion engine in which a circulating fluid known as engine coolant flows through radiator coils and air flows past the coils, which cools the coolant and heats the incoming air. Another example is the heat sink, which is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant.

<span class="mw-page-title-main">Heat transfer</span> Transport of thermal energy in physical systems

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy (heat) between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes. Engineers also consider the transfer of mass of differing chemical species, either cold or hot, to achieve heat transfer. While these mechanisms have distinct characteristics, they often occur simultaneously in the same system.

<span class="mw-page-title-main">Heat pipe</span> Heat-transfer device that employs phase transition

A heat pipe is a heat-transfer device that employs phase transition to transfer heat between two solid interfaces.

<span class="mw-page-title-main">STS-87</span> 1997 American crewed spaceflight

STS-87 was a Space Shuttle mission launched from Launch Complex 39B of the Kennedy Space Center on 19 November 1997. It was the 88th flight of the Space Shuttle and the 24th flight of Columbia. The mission goals were to conduct experiments using the United States Microgravity Payload (USMP-4), conduct two EVAs, and deploy the SPARTAN-201 experiment. This mission marked the first time an EVA was performed from Columbia. EVAs from Columbia were originally planned for STS-5 in 1982 and STS-80 in 1996, but were canceled due to spacesuit and airlock problems, respectively. It also marked the first EVA conducted by a Japanese astronaut, Takao Doi.

<span class="mw-page-title-main">Chiller</span> Machine that removes heat from a liquid coolant via vapor compression

A chiller is a machine that removes heat from a liquid coolant via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream. As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower. Absorption and adsorption chillers require a heat source to function.

<span class="mw-page-title-main">Computer cooling</span> The process of removing waste heat from a computer

Computer cooling is required to remove the waste heat produced by computer components, to keep components within permissible operating temperature limits. Components that are susceptible to temporary malfunction or permanent failure if overheated include integrated circuits such as central processing units (CPUs), chipsets, graphics cards, hard disk drives, and solid state drives.

<span class="mw-page-title-main">Marangoni effect</span> Physical phenomenon between two fluids

The Marangoni effect is the mass transfer along an interface between two phases due to a gradient of the surface tension. In the case of temperature dependence, this phenomenon may be called thermo-capillary convection.

<span class="mw-page-title-main">Shell-and-tube heat exchanger</span> Class of heat exchanger designs

A shell-and-tube heat exchanger is a class of heat exchanger designs. It is the most common type of heat exchanger in oil refineries and other large chemical processes, and is suited for higher-pressure applications. As its name implies, this type of heat exchanger consists of a shell with a bundle of tubes inside it. One fluid runs through the tubes, and another fluid flows over the tubes to transfer heat between the two fluids. The set of tubes is called a tube bundle, and may be composed of several types of tubes: plain, longitudinally finned, etc.

<span class="mw-page-title-main">Thermosiphon</span> Method of heat exchange in which convection drives pumpless circulation

Thermosiphon is a method of passive heat exchange, based on natural convection, which circulates a fluid without the necessity of a mechanical pump. Thermosiphoning is used for circulation of liquids and volatile gases in heating and cooling applications such as heat pumps, water heaters, boilers and furnaces. Thermosiphoning also occurs across air temperature gradients such as those utilized in a wood fire chimney or solar chimney.

<span class="mw-page-title-main">Absorption refrigerator</span> Refrigerator that uses a heat source

An absorption refrigerator is a refrigerator that uses a heat source to provide the energy needed to drive the cooling process. Solar energy, burning a fossil fuel, waste heat from factories, and district heating systems are examples of convenient heat sources that can be used. An absorption refrigerator uses two coolants: the first coolant performs evaporative cooling and then is absorbed into the second coolant; heat is needed to reset the two coolants to their initial states. Absorption refrigerators are commonly used in recreational vehicles (RVs), campers, and caravans because the heat required to power them can be provided by a propane fuel burner, by a low-voltage DC electric heater or by a mains-powered electric heater. Absorption refrigerators can also be used to air-condition buildings using the waste heat from a gas turbine or water heater in the building. Using waste heat from a gas turbine makes the turbine very efficient because it first produces electricity, then hot water, and finally, air-conditioning—trigeneration.

<span class="mw-page-title-main">Vapor-compression refrigeration</span> Refrigeration process

Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles. It is also used in domestic and commercial refrigerators, large-scale warehouses for chilled or frozen storage of foods and meats, refrigerated trucks and railroad cars, and a host of other commercial and industrial services. Oil refineries, petrochemical and chemical processing plants, and natural gas processing plants are among the many types of industrial plants that often utilize large vapor-compression refrigeration systems. Cascade refrigeration systems may also be implemented using two compressors.

<span class="mw-page-title-main">Multiphase flow</span> Simultaneous flow of materials with two or more thermodynamic phases

In fluid mechanics, multiphase flow is the simultaneous flow of materials with two or more thermodynamic phases. Virtually all processing technologies from cavitating pumps and turbines to paper-making and the construction of plastics involve some form of multiphase flow. It is also prevalent in many natural phenomena.

<span class="mw-page-title-main">Thermal expansion valve</span> Component of air conditioning and refrigeration systems

A thermal expansion valve or thermostatic expansion valve is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator to a steady value. Although often described as a "thermostatic" valve, an expansion valve is not able to regulate the evaporator's temperature to a precise value. The evaporator's temperature will vary only with the evaporating pressure, which will have to be regulated through other means.

<span class="mw-page-title-main">Evaporator</span> Machine transforming a liquid into a gas

An evaporator is a type of heat exchanger device that facilitates evaporation by utilizing conductive and convective heat transfer, which provides the necessary thermal energy for phase transition from liquid to vapor. Within evaporators, a circulating liquid is exposed to an atmospheric or reduced pressure environment, causing it to boil at a lower temperature compared to normal atmospheric boiling.

<span class="mw-page-title-main">Pumpable ice technology</span> Type of technology to produce and use fluids or secondary refrigerants

Pumpable icetechnology (PIT) uses thin liquids, with the cooling capacity of ice. Pumpable ice is typically a slurry of ice crystals or particles ranging from 5 micrometers to 1 cm in diameter and transported in brine, seawater, food liquid, or gas bubbles of air, ozone, or carbon dioxide.

<span class="mw-page-title-main">Spacecraft thermal control</span> Process of keeping all parts of a spacecraft within acceptable temperature ranges

In spacecraft design, the function of the thermal control system (TCS) is to keep all the spacecraft's component systems within acceptable temperature ranges during all mission phases. It must cope with the external environment, which can vary in a wide range as the spacecraft is exposed to the extreme coldness found in the shadows of deep space or to the intense heat found in the unfiltered direct sunlight of outer space. A TCS must also moderate the internal heat generated by the operation of the spacecraft it serves.

In refrigeration, flash-gas is refrigerant in gas form produced spontaneously when the condensed liquid is subjected to boiling. The presence of flash-gas in the liquid lines reduces the efficiency of the refrigeration cycle. It can also lead several expansion systems to work improperly, and increase superheating at the evaporator. This is normally perceived as an unwanted condition caused by dissociation between the volume of the system, and the pressures and temperatures that allow the refrigerant to be liquid. Flash-gas must not be confused with lack of condensation, but special gear such as receivers, internal heat exchangers, insulation, and refrigeration cycle optimizers may improve condensation and avoid gas in the liquid lines.

The Glossary of Geothermal Heating and Cooling provides definitions of many terms used within the Geothermal heat pump industry. The terms in this glossary may be used by industry professionals, for education materials, and by the general public.

The liquid droplet radiator (LDR) or previously termed liquid droplet stream radiator is a proposed lightweight radiator for the dissipation of waste heat generated by power plants, propulsion or spacecraft systems in space.

The low-temperature distillation (LTD) technology is the first implementation of the direct spray distillation (DSD) process. The first large-scale units are now in operation for desalination. The process was first developed by scientists at the University of Applied Sciences in Switzerland, focusing on low-temperature distillation in vacuum conditions, from 2000 to 2005.

References

  1. Ku, Jentung; Ottenstein, Laura; Douglas, Donya; Hoang, Triem (4 January 2010). Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control – Part 2: Validation Results. American Institute of Aeronautics and Astronomics. hdl:2060/20110015223 via NASA Technical Reports Server.
  2. Ku, Jentung; Paiva, Kleber; Mantelli, Marcia (31 July 2011). Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir. 9th Annual International Energy Conversion Engineering Conference. hdl:2060/20110015224 via NASA Technical Reports Server.
  3. Loop Heat Pipe – LHP Archived 2007-09-28 at the Wayback Machine
  4. Archived December 25, 2004, at the Wayback Machine