Penning ionization

Last updated

Penning ionization is a form of chemi-ionization, an ionization process involving reactions between neutral atoms or molecules. [1] [2] The Penning effect is put to practical use in applications such as gas-discharge neon lamps and fluorescent lamps, where the lamp is filled with a Penning mixture to improve the electrical characteristics of the lamps.

Contents

History

The process is named after the Dutch physicist Frans Michel Penning who first reported it in 1927. Penning started to work at the Philips Natuurkundig Laboratorium at Eindhoven to continue the investigation of electric discharge on rare gases. Later, he started measurements on the liberation of electrons from metal surfaces by positive ions and metastable atoms, and especially on the effects related to ionization by metastable atoms. [3]

Reaction

Penning ionization refers to the interaction between an electronically excited gas-phase atom G* and a target molecule M. The collision results in the ionization of the molecule yielding a cation M+., an electron e, and a neutral gas molecule, G, in the ground state. [4] Penning ionization occurs via formation of a high energy collision complex, evolving toward the formation of a cationic species, by ejecting a high energy electron. [5]

The process of ionization interaction between excited molecule and target molecule. Penning ionization.jpg
The process of ionization interaction between excited molecule and target molecule.

Penning ionization occurs when the target molecule has an ionization potential lower than the excited energy of the excited-state atom or molecule.

Variants

When the total electron excitation energy of colliding particles is sufficient, then the bonding energy of two particles that bonded together can also be contributed into the associative penning ionization act. [6] [7] [8] Associative Penning ionization can also occur:

Surface Penning ionization (Auger Deexcitation) refers to the interaction of the excited-state gas with a surface S, resulting in the release of an electron:

The positive charge symbol that would appear to be required for charge conservation is omitted, because S is a macroscopic surface and the loss of one electron has a negligible effect.

Applications

Electron spectroscopy

Penning ionization has been applied to Penning ionization electron spectroscopy (PIES) for gas chromatography detector in glow discharge by using the reaction for He* or Ne*. [2] [9] The kinetic energy of electron ejected is analyzed by the collisions between target (gas or solid) and metastable atoms by scanning the retarding field in a flight tube of the analyzer in the presence of a weak magnetic field. [9] [10] The electron produced by reaction has a kinetic energy E determined by:

The Penning ionization electron energy does not depend on the conditions of the experiments or any other species since both Em and IE are atomic or molecular constants of the energy of He* and the ionization energy for the species. [2] Penning ionization electron spectroscopy applied to organic solids. It enables the study of local electron distribution of individual molecular orbitals, which exposes to the outside of the outermost surface layers. [11]

Mass spectrometry

Multiple mass spectrometric techniques, [12] including glow discharge mass spectrometry and direct analysis in real time mass spectrometry rely on Penning ionization.

Glow discharge mass spectrometry is the direct determination of trace element in solid samples. It occurs with two ionization mechanisms: the direct electron impact ionization and Penning ionization. Processes inherent to the glow discharge, namely cathodic sputtering coupled with Penning ionization, yield an ion population from which semi-quantitative results can be directly obtained. [13]

See also

Related Research Articles

<span class="mw-page-title-main">Ionization</span> Process by which atoms or molecules acquire charge by gaining or losing electrons

Ionization is the process by which an atom or a molecule acquires a negative or positive charge by gaining or losing electrons, often in conjunction with other chemical changes. The resulting electrically charged atom or molecule is called an ion. Ionization can result from the loss of an electron after collisions with subatomic particles, collisions with other atoms, molecules and ions, or through the interaction with electromagnetic radiation. Heterolytic bond cleavage and heterolytic substitution reactions can result in the formation of ion pairs. Ionization can occur through radioactive decay by the internal conversion process, in which an excited nucleus transfers its energy to one of the inner-shell electrons causing it to be ejected.

<span class="mw-page-title-main">Mass spectrometry</span> Analytical technique based on determining mass to charge ratio of ions

Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures.

<span class="mw-page-title-main">Ion source</span> Device that creates charged atoms and molecules (ions)

An ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines.

<span class="mw-page-title-main">Electron ionization</span> Ionization technique

Electron ionization is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard ionization method, since it uses highly energetic electrons to produce ions. This leads to extensive fragmentation, which can be helpful for structure determination of unknown compounds. EI is the most useful for organic compounds which have a molecular weight below 600. Also, several other thermally stable and volatile compounds in solid, liquid and gas states can be detected with the use of this technique when coupled with various separation methods.

In physics, atomic spectroscopy is the study of the electromagnetic radiation absorbed and emitted by atoms. Since unique elements have unique emission spectra, atomic spectroscopy is applied for determination of elemental compositions. It can be divided by atomization source or by the type of spectroscopy used. In the latter case, the main division is between optical and mass spectrometry. Mass spectrometry generally gives significantly better analytical performance, but is also significantly more complex. This complexity translates into higher purchase costs, higher operational costs, more operator training, and a greater number of components that can potentially fail. Because optical spectroscopy is often less expensive and has performance adequate for many tasks, it is far more common. Atomic absorption spectrometers are one of the most commonly sold and used analytical devices.

<span class="mw-page-title-main">Penning trap</span> Device for storing charged particles

A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study as a tool for precision measurements of properties of ions and stable subatomic particles, like for example mass, fission yields and isomeric yield ratios. One initial object of study were the so-called geonium atoms, which represent a way to measure the electron magnetic moment by storing a single electron. These traps have been used in the physical realization of quantum computation and quantum information processing by trapping qubits. Penning traps are in use in many laboratories worldwide, including CERN, to store and investigate anti-particles such as antiprotons. The main advantages of Penning traps are the potentially long storage times and the existence of a multitude of techniques to manipulate and non-destructively detect the stored particles. This makes Penning traps versatile tools for the investigation of stored particles, but also for their selection, preparation or mere storage.

<span class="mw-page-title-main">Glow discharge</span> Plasma formed by passage of current through gas

A glow discharge is a plasma formed by the passage of electric current through a gas. It is often created by applying a voltage between two electrodes in a glass tube containing a low-pressure gas. When the voltage exceeds a value called the striking voltage, the gas ionization becomes self-sustaining, and the tube glows with a colored light. The color depends on the gas used.

<span class="mw-page-title-main">Chemical ionization</span> Ionization technique used in mass [[spectroscopy]]

Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry. Negative chemical ionization (NCI), charge-exchange chemical ionization, atmospheric-pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) are some of the common variants of the technique. CI mass spectrometry finds general application in the identification, structure elucidation and quantitation of organic compounds as well as some utility in biochemical analysis. Samples to be analyzed must be in vapour form, or else, must be vapourized before introduction into the source.

Gas phase ion chemistry is a field of science encompassed within both chemistry and physics. It is the science that studies ions and molecules in the gas phase, most often enabled by some form of mass spectrometry. By far the most important applications for this science is in studying the thermodynamics and kinetics of reactions. For example, one application is in studying the thermodynamics of the solvation of ions. Ions with small solvation spheres of 1, 2, 3... solvent molecules can be studied in the gas phase and then extrapolated to bulk solution.

<span class="mw-page-title-main">History of mass spectrometry</span>

The history of mass spectrometry has its roots in physical and chemical studies regarding the nature of matter. The study of gas discharges in the mid 19th century led to the discovery of anode and cathode rays, which turned out to be positive ions and electrons. Improved capabilities in the separation of these positive ions enabled the discovery of stable isotopes of the elements. The first such discovery was with the element neon, which was shown by mass spectrometry to have at least two stable isotopes: 20Ne and 22Ne. Mass spectrometers were used in the Manhattan Project for the separation of isotopes of uranium necessary to create the atomic bomb.

In mass spectrometry, direct analysis in real time (DART) is an ion source that produces electronically or vibronically excited-state species from gases such as helium, argon, or nitrogen that ionize atmospheric molecules or dopant molecules. The ions generated from atmospheric or dopant molecules undergo ion-molecule reactions with the sample molecules to produce analyte ions. Analytes with low ionization energy may be ionized directly. The DART ionization process can produce positive or negative ions depending on the potential applied to the exit electrode.

<span class="mw-page-title-main">Frans Michel Penning</span> Dutch physicist (1894–1953)

Frans Michel Penning was a Dutch experimental physicist. He received his PhD from the University of Leiden in 1923, and studied low pressure gas discharges at the Philips Laboratory in Eindhoven, developing new electron tubes during World War II. Many detailed observations of gas ionization were done with colleagues, finding notable results for helium and magnetic fields. He made precise measurements of Townsend discharge coefficients and cathode voltage fall. Penning made important contributions to the advancement of high resolution mass spectrometry.

Chemi-ionization is the formation of an ion through the reaction of a gas phase atom or molecule with another atom or molecule when the collision energy is below the energy required to ionize the reagents. The reaction may involve a reagent in an excited state or may result in the formation of a new chemical bond. Chemi-ionization can proceed through the Penning, associative, dissociative or rearrangement ionization reactions. Includes reactions that produce a free electron or a pair of ions.

Electron capture ionization is the ionization of a gas phase atom or molecule by attachment of an electron to create an ion of the form . The reaction is

Photoelectron photoion coincidence spectroscopy (PEPICO) is a combination of photoionization mass spectrometry and photoelectron spectroscopy. It is largely based on the photoelectric effect. Free molecules from a gas-phase sample are ionized by incident vacuum ultraviolet (VUV) radiation. In the ensuing photoionization, a cation and a photoelectron are formed for each sample molecule. The mass of the photoion is determined by time-of-flight mass spectrometry, whereas, in current setups, photoelectrons are typically detected by velocity map imaging. Electron times-of-flight are three orders of magnitude smaller than those of ions, which allows electron detection to be used as a time stamp for the ionization event, starting the clock for the ion time-of-flight analysis. In contrast with pulsed experiments, such as REMPI, in which the light pulse must act as the time stamp, this allows to use continuous light sources, e.g. a discharge lamp or a synchrotron light source. No more than several ion–electron pairs are present simultaneously in the instrument, and the electron–ion pairs belonging to a single photoionization event can be identified and detected in delayed coincidence.

An excimer lamp is a source of ultraviolet light based on spontaneous emission of excimer (exciplex) molecules.

<span class="mw-page-title-main">Helium dimer</span> Chemical compound

The helium dimer is a van der Waals molecule with formula He2 consisting of two helium atoms. This chemical is the largest diatomic molecule—a molecule consisting of two atoms bonded together. The bond that holds this dimer together is so weak that it will break if the molecule rotates, or vibrates too much. It can only exist at very low cryogenic temperatures.

The magnesium argide ion, MgAr+ is an ion composed of one ionised magnesium atom, Mg+ and an argon atom. It is important in inductively coupled plasma mass spectrometry and in the study of the field around the magnesium ion. The ionization potential of magnesium is lower than the first excitation state of argon, so the positive charge in MgAr+ will reside on the magnesium atom. Neutral MgAr molecules can also exist in an excited state.

<span class="mw-page-title-main">Resonance ionization</span> Process to excite an atom beyond its ionization potential to form an ion

Resonance ionization is a process in optical physics used to excite a specific atom beyond its ionization potential to form an ion using a beam of photons irradiated from a pulsed laser light. In resonance ionization, the absorption or emission properties of the emitted photons are not considered, rather only the resulting excited ions are mass-selected, detected and measured. Depending on the laser light source used, one electron can be removed from each atom so that resonance ionization produces an efficient selectivity in two ways: elemental selectivity in ionization and isotopic selectivity in measurement.

References

  1. Arango, C. A.; Shapiro, M.; Brumer, P. (2006). "Cold atomic collisions: coherent control of penning and associative ionization". Phys. Rev. Lett. 97 (19): 193202. arXiv: physics/0610131 . Bibcode:2006PhRvL..97s3202A. doi:10.1103/PhysRevLett.97.193202. PMID   17155624.
  2. 1 2 3 Hiraoka, K.; Furuya, H.; Kambara, S.; Suzuki, S.; Hashimoto, Y.; Takamizawa, A. (2006). "Atmospheric-pressure Penning ionization of aliphatic hydrocarbons". Rapid Commun. Mass Spectrom. 20 (21): 3213–22. Bibcode:2006RCMS...20.3213H. doi:10.1002/rcm.2706. PMID   17016831.
  3. Penning, F. M. (1927). "Über Ionisation durch metastabile Atome" [On the ionization of metastable atoms]. Die Naturwissenschaften (in German). 15 (40): 818. Bibcode:1927NW.....15..818P. doi:10.1007/bf01505431.
  4. IUPAC , Compendium of Chemical Terminology , 2nd ed. (the "Gold Book") (1997). Online corrected version: (2006) " Penning gas mixture ". doi : 10.1351/goldbook.P04476
  5. Falcinelli, Stefano; Candori, Pietro; Bettoni, Marta; Pirani, Fernando; Vecchiocattivi, Franco (2014). "Penning Ionization Electron Spectroscopy of Hydrogen Sulfide by Metastable Helium and Neon Atoms". The Journal of Physical Chemistry A. 118 (33): 6501–6506. Bibcode:2014JPCA..118.6501F. doi:10.1021/jp5030312. PMID   24796487.
  6. IUPAC , Compendium of Chemical Terminology , 2nd ed. (the "Gold Book") (1997). Online corrected version: (2006) " associative ionization ". doi : 10.1351/goldbook.A00475
  7. Cohen, James S. (1976). "Multistate curve-crossing model for scattering: Associative ionization and excitation transfer in helium". Physical Review A. 13 (1): 99–114. Bibcode:1976PhRvA..13...99C. doi:10.1103/PhysRevA.13.99.
  8. 1 2 Harada, Yoshiya (1990). "Penning ionization electron spectroscopy of organic molecules: stereochemistry of molecular orbitals". Pure Appl. Chem. 62 (3): 457–462. doi: 10.1351/pac199062030457 .
  9. Yoshihiro, Y.; Hideyasu, T.; Ryo, M.; Hideo, Y.; Fuminori, M.; Koichi, O. (200). "A highly sensitive electron spectrometer for crossed-beam collisional ionization: A retarding-type magnetic bottle analyzer and its application to collision-energy resolved Penning ionization electron spectroscopy". Review of Scientific Instruments. 71 (3): 3042–49. Bibcode:2000RScI...71.3042Y. doi:10.1063/1.1305819.
  10. Harada, Yoshiya; Ozaki, Hiroyuki (1987). "Penning Ionization Electron Spectroscopy: Its Application to Surface Characterization of Organic Solids". Jpn. J. Appl. Phys. 26 (8): 1201–1214. Bibcode:1987JaJAP..26.1201H. doi: 10.1143/JJAP.26.1201 .
  11. Gross, J. H. (2014). "Direct analysis in real time --- a critical review on DART-MS". Anal Bioanal Chem. 406: 63–80. doi:10.1007/s00216-013-7316-0. PMID   24036523.
  12. King, F. L.; Teng, J.; Steiner, R. E. (1995). "Special feature: Tutorial. Glow discharge mass spectrometry: Trace element determinations in solid samples". Journal of Mass Spectrometry. 30 (8): 1060–1075. Bibcode:1995JMSp...30.1061K. CiteSeerX   10.1.1.549.6325 . doi:10.1002/jms.1190300802.