Synchrocyclotron

Last updated
Sketch of a synchrocyclotron from McMillan's patent. Synchrocyclotron patent.png
Sketch of a synchrocyclotron from McMillan's patent.

A synchrocyclotron is a special type of cyclotron, patented by Edwin McMillan in 1952, in which the frequency of the driving RF electric field is varied to compensate for relativistic effects as the particles' velocity begins to approach the speed of light. This is in contrast to the classical cyclotron, where this frequency is constant. [1]

Contents

There are two major differences between the synchrocyclotron and the classical cyclotron. In the synchrocyclotron, only one dee (hollow D-shaped sheet metal electrode) retains its classical shape, while the other pole is open (see patent sketch). Furthermore, the frequency of oscillating electric field in a synchrocyclotron is decreasing continuously instead of kept constant so as to maintain cyclotron resonance for relativistic velocities. One terminal of the oscillating electric potential varying periodically is applied to the dee and the other terminal is on ground potential. The protons or deuterons to be accelerated are made to move in circles of increasing radius. The acceleration of particles takes place as they enter or leave the dee. At the outer edge, the ion beam can be removed with the aid of electrostatic deflector. The first synchrocyclotron produced 195 MeV deuterons and 390 MeV α-particles. [2]

Differences from the classical cyclotron

In a classical cyclotron, the angular frequency of the electric field is given by

,

Where is the angular frequency of the electric field, is the charge on the particle, is the magnetic field, and is the mass of the particle. This makes the assumption that the particle is classical, and does not experience relativistic phenomena such as length contraction. These effects start to become significant when , the velocity of the particle greater than . To correct for this, the relativistic mass is used instead of the rest mass; thus, a factor of multiplies the mass, such that

,

where

.

This is then the angular frequency of the field applied to the particles as they are accelerated around the synchrocyclotron.

Advantages

A part of the former Orsay synchrocyclotron Orsay proton therapy dsc04443.jpg
A part of the former Orsay synchrocyclotron

The chief advantage of the synchrocyclotron is that there is no need to restrict the number of revolutions executed by the ion before its exit. As such, the potential difference supplied between the dees can be much smaller.

The smaller potential difference needed across the gap has the following uses:

  1. There is no need for a narrow gap between the dees as in the case of conventional cyclotron, because strong electric fields for producing large acceleration are not required. Thus only one dee can be used instead of two, the other end of the oscillating voltage supply being connected to earth.
  2. The magnetic pole pieces can be brought closer, thus making it possible to increase greatly the magnetic flux density.
  3. The frequency valve oscillator is able to function with much greater efficiency.

Disadvantages

The main drawback of this device is that, as a result of the variation in the frequency of the oscillating voltage supply, only a very small fraction of the ions leaving the source are captured in phase-stable orbits of maximum radius and energy with the result that the output beam current has a low duty cycle, and the average beam current is only a small fraction of the instantaneous beam current. Thus the machine produces high energy ions, though with comparatively low intensity.

The next development step of the cyclotron concept, the isochronous cyclotron, maintains a constant RF driving frequency and compensates for relativistic effects by increasing the magnetic field with radius. Isochronous cyclotrons are capable of producing much greater beam current than synchrocyclotrons. As a result, isochronous cyclotrons became more popular in the research field.

History

The Synchrocyclotron (SC) at CERN The 600 MeV Synchrocyclotron (SC) at CERN.jpg
The Synchrocyclotron (SC) at CERN

In 1945, Robert Lyster Thornton at Ernest Lawrence's Radiation Laboratory led the construction of the 184-inch (470 cm) 730 MeV cyclotron. In 1946, he oversaw the conversion of the cyclotron to the new design made by McMillan which would become the first synchrocyclotron with could produce 195 MeV deuterons and 390 MeV α-particles.

After the first synchrocyclotron was operational, the Office of Naval Research (ONR) funded two synchrocyclotron construction initiatives. The first funding was in 1946 for Carnegie Institute of Technology to build a 435-MeV synchrocyclotron led by Edward Creutz and to start its nuclear physics research program. The second initiative was in 1947 for University of Chicago to build a 450-MeV synchrocyclotron under the direction of Enrico Fermi.

In 1948, University of Rochester completed the construction of its 240-MeV synchrocyclotron, followed by a completion of 380-MeV synchrocyclotron at Columbia University in 1950.

In 1950 the 435-MeV synchrocyclotron at Carnegie Institute of Technology was operational, followed by 450-MeV synchrocyclotron of University of Chicago in 1951. [2]

The construction of the 400-Mev synchrocyclotron at the University of Liverpool was completed in 1952 and by April 1954 it was operational. The Liverpool synchrocyclotron first demonstrated the extraction of a particle beam from such a machine, removing the constraint of having to fit experiments inside the synchrocyclotron. [3]

At a UNESCO meeting in Paris in December 1951, there was a discussion on finding a solution to have a medium-energy accelerator for the soon-to-be-formed European Organization for Nuclear Research (CERN). The synchrocyclotron was proposed as a solution to bridge the gap before the 28-GeV Proton Synchrotron was completed. In 1952, Cornelis Bakker led the group to design and construct the synchrocyclotron named Synchro-Cyclotron (SC) at CERN. The design of the Synchro-Cyclotron with 15.7 metres (52 ft) in circumference started in 1953. The construction started in 1954 and it achieved 600 MeV proton acceleration in August 1957, with the experimental program started in April 1958. [4]

Current developments

Synchrocyclotrons are attractive for use in proton therapy because of the ability to make compact systems using high magnetic fields. Medical physics companies Ion Beam Applications and Mevion Medical Systems have developed superconducting synchrocyclotrons that can fit comfortably into hospitals. [5] [6]

Related Research Articles

<span class="mw-page-title-main">Cyclotron</span> Type of particle accelerator

A cyclotron is a type of particle accelerator invented by Ernest Lawrence in 1929–1930 at the University of California, Berkeley, and patented in 1932. A cyclotron accelerates charged particles outwards from the center of a flat cylindrical vacuum chamber along a spiral path. The particles are held to a spiral trajectory by a static magnetic field and accelerated by a rapidly varying electric field. Lawrence was awarded the 1939 Nobel Prize in Physics for this invention.

<span class="mw-page-title-main">Synchrotron radiation</span> Electromagnetic radiation emitted by charged particles accelerated perpendicular to their velocity

Synchrotron radiation is the electromagnetic radiation emitted when relativistically charged particles are subject to an acceleration perpendicular to their velocity. It is produced artificially in some types of particle accelerators or naturally by fast electrons moving through magnetic fields. The radiation produced in this way has a characteristic polarization, and the frequencies generated can range over a large portion of the electromagnetic spectrum.

<span class="mw-page-title-main">Linear particle accelerator</span> Type of particle accelerator

A linear particle accelerator is a type of particle accelerator that accelerates charged subatomic particles or ions to a high speed by subjecting them to a series of oscillating electric potentials along a linear beamline. The principles for such machines were proposed by Gustav Ising in 1924, while the first machine that worked was constructed by Rolf Widerøe in 1928 at the RWTH Aachen University. Linacs have many applications: they generate X-rays and high energy electrons for medicinal purposes in radiation therapy, serve as particle injectors for higher-energy accelerators, and are used directly to achieve the highest kinetic energy for light particles for particle physics.

Electron cyclotron resonance (ECR) is a phenomenon observed in plasma physics, condensed matter physics, and accelerator physics. It happens when the frequency of incident radiation coincides with the natural frequency of rotation of electrons in magnetic fields. A free electron in a static and uniform magnetic field will move in a circle due to the Lorentz force. The circular motion may be superimposed with a uniform axial motion, resulting in a helix, or with a uniform motion perpendicular to the field resulting in a cycloid. The angular frequency of this cyclotron motion for a given magnetic field strength B is given by

<span class="mw-page-title-main">Dipole magnet</span> Simplest type of magnet

A dipole magnet is the simplest type of magnet. It has two poles, one north and one south. Its magnetic field lines form simple closed loops which emerge from the north pole, re-enter at the south pole, then pass through the body of the magnet. The simplest example of a dipole magnet is a bar magnet.

<span class="mw-page-title-main">Penning trap</span> Device for storing charged particles

A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study as a tool for precision measurements of properties of ions and stable subatomic particles, like for example mass, fission yields and isomeric yield ratios. One initial object of study were the so-called geonium atoms, which represent a way to measure the electron magnetic moment by storing a single electron. These traps have been used in the physical realization of quantum computation and quantum information processing by trapping qubits. Penning traps are in use in many laboratories worldwide, including CERN, to store and investigate anti-particles such as antiprotons. The main advantages of Penning traps are the potentially long storage times and the existence of a multitude of techniques to manipulate and non-destructively detect the stored particles. This makes Penning traps versatile tools for the investigation of stored particles, but also for their selection, preparation or mere storage.

<span class="mw-page-title-main">Synchrotron</span> Type of cyclic particle accelerator

A synchrotron is a particular type of cyclic particle accelerator, descended from the cyclotron, in which the accelerating particle beam travels around a fixed closed-loop path. The magnetic field which bends the particle beam into its closed path increases with time during the accelerating process, being synchronized to the increasing kinetic energy of the particles. The synchrotron is one of the first accelerator concepts to enable the construction of large-scale facilities, since bending, beam focusing and acceleration can be separated into different components. The most powerful modern particle accelerators use versions of the synchrotron design. The largest synchrotron-type accelerator, also the largest particle accelerator in the world, is the 27-kilometre-circumference (17 mi) Large Hadron Collider (LHC) near Geneva, Switzerland, built in 2008 by the European Organization for Nuclear Research (CERN). It can accelerate beams of protons to an energy of 13 tera electronvolts (TeV or 1012 eV).

<span class="mw-page-title-main">Ion trap</span> Device for trapping charged particles

An ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision mass spectrometry, improved atomic frequency standards, and quantum computing. In comparison to neutral atom traps, ion traps have deeper trapping potentials that do not depend on the internal electronic structure of a trapped ion. This makes ion traps more suitable for the study of light interactions with single atomic systems. The two most popular types of ion traps are the Penning trap, which forms a potential via a combination of static electric and magnetic fields, and the Paul trap which forms a potential via a combination of static and oscillating electric fields.

In physics, Larmor precession is the precession of the magnetic moment of an object about an external magnetic field. The phenomenon is conceptually similar to the precession of a tilted classical gyroscope in an external torque-exerting gravitational field. Objects with a magnetic moment also have angular momentum and effective internal electric current proportional to their angular momentum; these include electrons, protons, other fermions, many atomic and nuclear systems, as well as classical macroscopic systems. The external magnetic field exerts a torque on the magnetic moment,

<span class="mw-page-title-main">Proton Synchrotron</span> CERNs first synchrotron accelerator

The Proton Synchrotron is a particle accelerator at CERN. It is CERN's first synchrotron, beginning its operation in 1959. For a brief period the PS was the world's highest energy particle accelerator. It has since served as a pre-accelerator for the Intersecting Storage Rings (ISR) and the Super Proton Synchrotron (SPS), and is currently part of the Large Hadron Collider (LHC) accelerator complex. In addition to protons, PS has accelerated alpha particles, oxygen and sulfur nuclei, electrons, positrons, and antiprotons.

<span class="mw-page-title-main">Electron scattering</span> Deviation of electrons from their original trajectories

Electron scattering occurs when electrons are displaced from their original trajectory. This is due to the electrostatic forces within matter interaction or, if an external magnetic field is present, the electron may be deflected by the Lorentz force. This scattering typically happens with solids such as metals, semiconductors and insulators; and is a limiting factor in integrated circuits and transistors.

<span class="mw-page-title-main">Mass-to-charge ratio</span> Physical quantity of interest in chemistry and electrodynamics

The mass-to-charge ratio (m/Q) is a physical quantity relating the mass (quantity of matter) and the electric charge of a given particle, expressed in units of kilograms per coulomb (kg/C). It is most widely used in the electrodynamics of charged particles, e.g. in electron optics and ion optics.

The gyroradius is the radius of the circular motion of a charged particle in the presence of a uniform magnetic field. In SI units, the non-relativistic gyroradius is given by

Cyclotron resonance describes the interaction of external forces with charged particles experiencing a magnetic field, thus already moving on a circular path. It is named after the cyclotron, a cyclic particle accelerator that utilizes an oscillating electric field tuned to this resonance to add kinetic energy to charged particles.

<span class="mw-page-title-main">Particle accelerator</span> Research apparatus for particle physics

A particle accelerator is a machine that uses electromagnetic fields to propel charged particles to very high speeds and energies, and to contain them in well-defined beams.

<span class="mw-page-title-main">Microwave cavity</span> Metal structure which confines microwaves or radio waves for resonance

A microwave cavity or radio frequency cavity is a special type of resonator, consisting of a closed metal structure that confines electromagnetic fields in the microwave or RF region of the spectrum. The structure is either hollow or filled with dielectric material. The microwaves bounce back and forth between the walls of the cavity. At the cavity's resonant frequencies they reinforce to form standing waves in the cavity. Therefore, the cavity functions similarly to an organ pipe or sound box in a musical instrument, oscillating preferentially at a series of frequencies, its resonant frequencies. Thus it can act as a bandpass filter, allowing microwaves of a particular frequency to pass while blocking microwaves at nearby frequencies.

A Fixed-Field alternating gradient Accelerator is a circular particle accelerator concept that can be characterized by its time-independent magnetic fields and the use of alternating gradient strong focusing.

<span class="mw-page-title-main">The Svedberg Laboratory</span>

The The Svedberg Laboratory (TSL) is a university facility, based in Uppsala, Sweden. The activities at TSL are based around the particle accelerator Gustaf Werner cyclotron.

<span class="mw-page-title-main">Synchro-Cyclotron (CERN)</span>

The Synchro-Cyclotron, or Synchrocyclotron (SC), built in 1957, was CERN’s first accelerator. It was 15.7 metres (52 ft) in circumference and provided beams for CERN's first experiments in particle and nuclear physics. It accelerated particles to energies up to 600 MeV. The foundation stone of CERN was laid at the site of the Synchrocyclotron by the first Director-General of CERN, Felix Bloch. After its remarkably long 33 years of service time, the SC was decommissioned in 1990. Nowadays it accepts visitors as an exhibition area in CERN.

<span class="mw-page-title-main">Nuclear Physics Institute of the Czech Academy of Sciences</span>

The Nuclear Physics Institute of the Czech Academy of Sciences is a public research institution located in Řež, Central Bohemian Region, Czech Republic. It was established in 1972 from the Physics Section of the former institute of Nuclear Research of the Czechoslovak Academy of Sciences.

References

  1. 1 2 USpatent 2615129, Edwin McMillan,"Synchro-Cyclotron",issued 1952-10-21
  2. 1 2 "Accelerators, 1945-1960". Array of Contemporary American Physicists. Retrieved 8 August 2017.
  3. Lea, Rob (11 May 2022). "The legacy of Liverpool's forgotten synchrocyclotron". Physics World . Retrieved 31 July 2022.
  4. Reyes, Sandrine (April 2002). "Description of Archives of Synchro-Cyclotron Division, SC". CERN-ARCH-SC-001 to CERN-ARCH-SC-268. Retrieved 8 August 2017.
  5. "Proteus©ONE Think big, scale smart".