Zaara Street Power Station

Last updated

Zaara Street Power Station
Zaara Street Power Station
Location of Zaara Street Power Station
Country
  • Australia
Location Newcastle East, New South Wales, Australia
Coordinates 32°55′31″S151°47′19″E / 32.925367°S 151.788550°E / -32.925367; 151.788550
StatusDecommissioned and demolished
Commission date 1915
Decommission date1975
Thermal power station
Primary fuel Thermal coal
Power generation
Nameplate capacity 70.75  MW (94,880  hp)

Zaara Street Power Station is a former coal-fired power station that was situated on Zaara Street, in the city of Newcastle, in New South Wales, Australia. The power station was built to supply power for the New South Wales Government Railways (NSWGR) in 1915, when the first turbo-alternator of 2.5 megawatts (3,400  hp ) was commissioned. The installation of additional plant in 1920 led to a generating capacity of 28.5 megawatts (38,200 hp). The station was decommissioned in 1975 and demolished in 1978.

Contents

History

In 1920 [1] the Zaara Street Power Station started with a 7.5-megawatt (10,100 hp) Curtis GE turbo-alt (No.2) from White Bay and a 2.5-megawatt (3,400 hp) GE turbo-alt (No.3A) both delivering 6.6kV at 25 Hz (1500rpm). Additional power was needed in 1921 and another 2.5-megawatt (3,400 hp) Vickers-Willans alternator (No.3B) was added. Steam was supplied by 4 Babcock & Wilcox WIF long drum chain grate boilers. Each boiler produced 40,000 pounds per hour (5,000 kg/ks) at 200 pounds per square inch (1,400 kPa) and 580 °F (304 °C).

1922 saw a 2.5-megawatt (3,400 hp) British Thompson Houston 50 Hz (3000rpm) alternator (No.4A) and a 1.5-megawatt (2,000 hp) Parsons alternator (No.1) added. More power was required in 1924 and a 7.5-megawatt (10,100 hp) BTH alternator (No.5) was installed. This was followed in 1928 by another 7.5-megawatt (10,100 hp) BTH alternator (No.6). Terminal voltage for these 50 Hz machines was 11kV. Four extra boilers were installed from 1930 to supply these machines. The last change to the low pressure plant was that the No.1 Parsons 1.5-megawatt (2,000 hp) alternator was removed and in its place a 7.5-megawatt (10,100 hp) Bellis & Morcom alternator (No.1) in 1936. [2]

Surplus capacity in the Railway Commissioner's power grid was sold to municipal councils and other bodies responsible for the supply of electricity to the general public. Zaara Street Power Station was connected to the grid of the Electricity Supply Department of the Newcastle Borough Council in 1917, and supplied much of Newcastle's electricity needs throughout the 1920s. Later known as the Newcastle Electricity Supply Council Administration (NESCA), the Newcastle Borough Council also operated a small power station with two alternators and a capacity of approximately 2.6 megawatts (3,500 hp). Built in the 1890s, 'NESCA' Power Station was situated approximately one mile from Zaara Street, and closed in 1953.

High pressure plant

In 1939 a different approach was taken to supply more power more reliably. The first addition was a 15-megawatt (20,000 hp) Brush-Ljunstrom 50 Hz turbo-alternator (No.4). The next year a 12-megawatt (16,000 hp) Fraser + Chalmers ex-Pyrmont alternator was placed in the No.3 position. Steam was supplied to all the high pressure plant by four Babcock & Wilcox high head boilers. Each boiler produced 155,000 pounds per hour (19,500 kg/ks) at 420 pounds per square inch (2,900 kPa) and 810 °F (432 °C). A 20-megawatt (27,000 hp) British Thomson Houston alternator (No.4) was delivered in 1942 and a 15-megawatt (20,000 hp) Westinghouse alternator (No.5) installed in 1944. The No.5 7.5-megawatt (10,100 hp) machine became the number 7 alternator at this time to avoid confusion. Also, the No.2 7.5-megawatt (10,100 hp) machine was replaced with a slightly larger 8.75-megawatt (11,730 hp) Dick Kerr alternator (No.2), ex-White Bay. This gave Zaara Street a new total output of 70.75 megawatts (94,880 hp).

Control of Zaara Street was transferred from the NSWGR to the Electricity Commission of New South Wales on 1 January 1953. By the 1960s only the new boilers and sets 4, 5 & 7 were still in operation. The ECNSW continued to operate the power station until it was officially closed in 1975.

Zaara Street Power Station was demolished in 1978, and all railway facilities in the vicinity were redeveloped into what is now known as The Foreshore. No traces of the power station have survived on the site.

Related Research Articles

<span class="mw-page-title-main">Richmond Power Station</span>

Richmond Power Station was a coal fired power station which operated on the banks of the Yarra River in Richmond, Victoria, Australia from its construction in 1891 until its closure in 1976. It was one of the first alternating current (AC) electricity generation plants in the state. It has since been converted into office space and is the headquarters of international fashion brand Country Road and advertising agency CHE Proximity. The area in which it is located is now called Cremorne.

<span class="mw-page-title-main">Newport Power Station</span>

The Newport Power Station was a complex of power stations located on the west bank of the Yarra River, approximately 6 km south-west of Melbourne, Victoria, Australia, in the suburb of Newport. Newport A, B, and C were coal-fired plants which operated at the site between 1919 and the 1980s, and were claimed to be the largest power station in the southern hemisphere in 1953 with 42 boilers and 14 turbo-alternators producing 327 megawatts (439,000 hp).

Cockle Creek Power Station was located in Teralba, New South Wales, Australia, on the banks of Cockle Creek. The power stationed operated from 11 March 1927 until March 1976.

<span class="mw-page-title-main">Kearsley Power Station</span> Former coal-fired power station

Kearsley Power Station was a coal-fired power station in Stoneclough, near Kearsley, Bolton, England. It was designed in 1927 by Dr H.F. Parshall for the Lancashire Electric Power Company. The original installation was known as Kearsley 'A', comprising two British Thomson-Houston (B.T.H.) turbo-alternators rated at 32.25 megawatts each. Further extensions became Kearsley 'B' (1936/38), with two more B.T.H. turbo-alternators each capable of producing 51.6 megawatts. Finally Kearsley 'C' (1949) was completed with two more B.T.H. machines rated at 52 megawatts each. The station closed in 1980 when only 'B' station remained operational. The 5 cooling towers were demolished during the week of 14 May 1985.

<span class="mw-page-title-main">Dunston Power Station</span> Coal-fired power station in England

Dunston Power Station refers to a pair of adjacent coal-fired power stations in the North East of England, now demolished. They were built on the south bank of the River Tyne, in the western outskirts of Dunston in Gateshead. The two stations were built on a site which is now occupied by the MetroCentre. The first power station built on the site was known as Dunston A Power Station, and the second, which gradually replaced it between 1933 and 1950, was known as Dunston B Power Station. The A Station was, in its time, one of the largest in the country, and as well as burning coal had early open cycle gas turbine units. The B Station was the first of a new power station design, and stood as a landmark on the Tyne for over 50 years. From the A Station's opening in 1910 until the B Station's demolition in 1986, they collectively operated from the early days of electricity generation in the United Kingdom, through the industry's nationalisation, and until a decade before its privatisation.

Neptune Bank Power Station was a coal-fired power station situated on the River Tyne at Wallsend near Newcastle upon Tyne. Commissioned in 1901 by the Newcastle upon Tyne Electric Supply Company, the station was the first in the world to provide electricity for purposes other than domestic and street lighting. It was also the first in the world to generate electricity using three-phase electrical power distribution at a voltage of 5,500 volts.

Stuart Street Power Station was a coal-fired power station in Bradford, Manchester, England.

<span class="mw-page-title-main">Darlington Power Station</span> British coal-fired power station

Darlington power station refers to a series of two coal-fired power stations situated in Darlington in County Durham, North East England.

<span class="mw-page-title-main">Cliff Quay Power Station</span>

Cliff Quay Power Station was a coal-fired power station situated to the south of Ipswich, Suffolk in the East of England. The station was designed by Sir Alexander Gibb & Partners and built by the Cleveland Bridge Company.

Hayle Power Station was a coal-fired power station situated at the mouth of the River Hayle, at Hayle in Cornwall, South West England.

<span class="mw-page-title-main">Pyrmont Power Station</span>

Pyrmont Power Station was an electricity generating plant located in the Sydney suburb of Pyrmont, New South Wales.

The Ultimo Power Station, or Ultimo Powerhouse, was an electricity generating plant located in the inner-city Sydney suburb of Ultimo, New South Wales. Commissioned in 1899, it was the first major power station in Sydney and was originally built to supply power for the electric tram network. Prior to this, a small installation had existed at Regent Street, which was brought into use on 15 June 1882. Additionally, experimental electric tram operations powered by small generators had been in intermittent use in Sydney since 1890.

Lithgow power station was an Australian power station built in 1928 to supply power to the New South Wales Government Railways, the small arms factory, Hoskins mine and Lithgow council. The initial plant was two 2.5MW BTH/English Electric turbo alternators that were no longer needed at Ultimo power station. A third 2.5MW turbo alternator from Zaara Street, Newcastle was added in 1931. A fourth 2.5MWBTH machine was installed in 1936. In 1943 a 2.5MW Willans & Robinson generator from Zaara St became No5 at Lithgow. Steam was supplied from four 160,000 lb/Hr boilers at 200PSI and a temp of 450degF. Coal came from the nearby State Mine. Due to a severe lack of water, these turbines only exhausted into individual jet condensers.

Southampton Power Station was a coal fired power station built by Southampton Corporation that operated between 1904 and 1977.

Lincoln power stations were a sequence of electricity generating stations that provided electric power to the City of Lincoln and the wider area between 1898 and 1977. The first station was built by Lincoln Corporation in 1898 on Brayford Wharf. During the First World War the engineering company Clayton and Shuttleworth built a power station in Spa Road to meet its own electricity needs. This private station was bought by Lincoln Corporation in 1918 and was expanded to meet rising demand and supplied electricity until it was demolished in 1953. A final power station was built on the Spa Road site over the period 1947–57 and operated until it was decommissioned in 1977.

Burton upon Trent power station supplied electricity to the town of Burton upon Trent and the wider area from 1894 to 1976. It was owned and operated by Burton upon Trent Corporation until the nationalisation of the British electricity supply industry in 1948. The power station was redeveloped several times: including the incorporation of new plant in the 1910s, in 1924–28 and 1941–43. The station was decommissioned in October 1976.

Greenhill power station supplied electricity to the town of Oldham, England and the surrounding area from 1921 to 1960. It replaced the older Rhodes Bank generating station and was superseded by Chadderton B power station. Greenhill power station was owned and operated by Oldham Corporation until the nationalisation of the British electricity supply industry in 1948. The power station was built over the period 1921–24 and was decommissioned in 1960.

The Newport power stations supplied electricity to the town of Newport and the surrounding area from 1895 to the late 1970s. The original power station was in Llanarth Street which supplied electric lighting; a larger station, known as the East power station, was built in Corporation Road from 1903. They were owned and operated by Newport Corporation prior to the nationalisation of the British electricity supply industry in 1948. The East power station was redeveloped in the 1920s and 1940s to meet the increased demand for electricity.

Trafford power station supplied electricity to the Trafford and Stretford areas of Greater Manchester, and to the national grid, from 1929 to 1976. The generating station was built by the Stretford and District Electricity Board which it operated until the nationalisation of the British electricity supply industry in 1948. The 60 megawatt coal-fired station was supplemented in 1952 with an experimental 15 megawatt gas turbine generating set.

Stockport power station supplied electricity to the town of Stockport, Cheshire and the surrounding area from 1899 to 1976. The power station was owned and operated by Stockport Corporation prior to the nationalisation of the British electricity supply industry in 1948. It was redeveloped several times to meet the increased demand for electricity.

References

  1. Myer, Harold (1925). Power Supply and Distribution.
  2. Fetscher, Mark. The Power Station of the NSWGR.