A ceiling fan is a fan mounted on the ceiling of a room or space, usually electrically powered, that uses hub-mounted rotating blades to circulate air. They cool people effectively by increasing air speed. Fans do not reduce air temperature or relative humidity, unlike air-conditioning equipment but create a cooling effect by helping to evaporate sweat and increase heat exchange via convection. Fans add a small amount of heat to the room mainly due to waste heat from the motor, and partially due to friction. Fans use significantly less power than air conditioning as cooling air is thermodynamically expensive. In the winter, fans move warmer air, which naturally rises, back down to occupants. This can affect both thermostat readings and occupants' comfort, thereby improving the energy efficiency of climate control. Many ceiling fan units also double as light fixtures, eliminating the need for separate overhead lights in a room.

Contents

History

Punkah style ceiling fans are based on the earliest form of the fan, which was first invented in India around 500 BC. These were cut from an Indian palmyra leaf which forms its rather large blade, moving slowly in a pendular manner. Originally operated manually by a cord [1] and nowadays powered electrically using a belt-driven system, these punkahs move air by going to and fro. In comparison to a rotating fan, it creates a gentle breeze rather than an airflow.

Ceiling fan originally installed in the dining room of the house in Perry's Camp, turned by the water wheel Perry's Camp ceiling fan.JPG
Ceiling fan originally installed in the dining room of the house in Perry's Camp, turned by the water wheel

The first rotary ceiling fans appeared in the early 1860s and 1870s in the United States. At that time, they were not powered by any form of electric motor. Instead, a stream of running water was used, in conjunction with a turbine, to drive a system of belts which would turn the blades of two-blade fan units. These systems could accommodate several fan units, and became popular in stores, restaurants, and offices. Some of these systems survive today, and can be seen in parts of the southern United States where they originally proved useful.

The electrically powered ceiling fan was invented in 1882 by Philip Diehl. He had engineered the electric motor used in the first electrically powered Singer sewing machines, and in 1882 he adapted that motor for use in a ceiling-mounted fan. Each fan had its own self-contained motor unit, with no need for belt drive. [2]

Almost immediately he faced fierce competition due to the commercial success of the ceiling fan. He continued to make improvements to his invention and created a light kit fitted to the ceiling fan to combine both functions in one unit. By World War I most ceiling fans were made with four blades instead of the original two, which made fans quieter and allowed them to circulate more air. The early turn-of-the-century companies who successfully commercialized the sale of ceiling fans in the United States were what is today known as the Hunter Fan Company, Robbins & Myers, Century Electric, Westinghouse Corporation and Emerson Electric.

By the 1920s, ceiling fans became commonplace in the United States and had started to take hold internationally. From the Great Depression of the 1930s, until the introduction of electric air conditioning in the 1950s, ceiling fans slowly faded out of vogue in the U.S., [2] almost falling into total disuse in the U.S. by the 1960s; those that remained were considered items of nostalgia.

Late '80s Usha Prima, one of the most common ceiling fans in India Late 80s Usha Prima.jpg
Late '80s Usha Prima, one of the most common ceiling fans in India

Meanwhile, ceiling fans became very popular in other countries, particularly those with hot climates, such as India and the Middle East, where a lack of infrastructure and/or financial resources made energy-hungry and complex freon-based air conditioning equipment impractical. In 1973, Texas entrepreneur H. W. (Hub) Markwardt began importing ceiling fans into the United States that were manufactured in India by Crompton Greaves, Ltd. Crompton Greaves had been manufacturing ceiling fans since 1937 through a joint venture formed by Greaves Cotton of India and Crompton Parkinson of England. These Indian manufactured ceiling fans caught on slowly at first, but Markwardt's Encon Industries branded ceiling fans (which stood for ENergy CONservation) eventually found great success during the energy crisis of the late 1970s and early 1980s since they consumed less energy than the antiquated shaded pole motors used in most other American made fans. The fans became the energy-saving appliances for residential and commercial use by supplementing expensive air conditioning units with a column of gentle airflow.

Casablanca Fan Co. "Delta" ceiling fan from the early 1980s. Casablanca Delta ceiling fan.JPG
Casablanca Fan Co. "Delta" ceiling fan from the early 1980s.

Due to this renewed commercial success using ceiling fans effectively as an energy conservation application, many American manufacturers also started to produce, or significantly increase the production of, ceiling fans. In addition to the imported Encon ceiling fans, the Casablanca Fan Company was founded in 1974. Other American manufacturers of the time included the Hunter Fan Co. (which was then a division of Robbins & Myers, Inc), FASCO (F. A. Smith Co.), and Emerson Electric; which was often branded as Sears-Roebuck. Smaller, short-lived companies include NuTone, Southern Fan Co., A&G Machinery Co., Homestead, Hallmark, Union, Lasko, and Evergo.

Through the 1980s and 1990s, ceiling fans remained popular in the United States. Many small American importers, most of them rather short-lived, started importing ceiling fans. Throughout the 1980s, the balance of sales between American-made ceiling fans and those imported from manufacturers in India, Taiwan, Hong Kong and eventually China changed dramatically with imported fans taking the lion's share of the market by the late 1980s. Even the most basic U.S-made fans sold for $200 to $500, while the most expensive imported fans rarely exceeded $150.

Since 1980, ceiling fan technology has not evolved much until recently[ when? ], with the availability of energy-efficient, remote/app controlled brushless DC fans to the masses. However, important inroads have been made in design by companies such as Monte Carlo, Minka Aire, Quorum, Craftmade, Litex and Fanimation - offering higher price ceiling fans with more decorative value. In 2001, Washington Post writer Patricia Dane Rogers [3] wrote, "Like so many other mundane household objects, these old standbys are going high-style and high-tech."

Uses

Ceiling fans have multiple functions. Fans increase mixing in a ventilated space, which leads to more homogenous environmental conditions. Moving air is generally preferred over stagnant air, especially in warm or neutral environments, so fans are useful in increasing occupant satisfaction. [4] Because fans do not change air temperature and humidity, but move it around, fans can aid in both the heating and cooling of a space. Because of this, ceiling fans are often an instrumental element of low energy HVAC, passive cooling or natural ventilation systems in buildings. Depending on the energy use of the fan system, fans can be an efficient way to improve thermal comfort by allowing for a higher ambient air temperature while keeping occupants comfortable. [5] [6] Fans are an especially economic choice in warm, humid environments.

Ceiling fans can be controlled together in a shared space, and can also be individually controlled in a home or office setting.  In an office environment, individually controlled ceiling fans can have a significant positive impact on thermal comfort, which has been shown to increase productivity and satisfaction among occupants. [6] Ceiling fans aid in the distribution of fresh air in both mechanically ventilated and naturally ventilated spaces. In naturally ventilated spaces, ceiling fans are effective at drawing in and circulating fresh outdoor air. [7]  In mechanically ventilated spaces, fans can be focused to channel and circulate conditioned air in a room.

Direction

The direction that a fan spins should change based on whether the room needs to be heated or cooled. Unlike air conditioners, fans only move air—they do not directly change its temperature. Therefore, ceiling fans that have a mechanism for reversing the direction in which the blades push air (most commonly an electrical switch on the unit's switch housing, motor housing, or lower canopy) can help in both heating and cooling.

While ceiling fan manufacturers (mainly Emerson) have had electrically reversible motors in production since the 1930s, most fans made before the mid-1970s are either not reversible at all or mechanically reversible (have adjustable blade pitch) instead of an electrically reversible motor. In this case, the blades should be pitched with the upturned edge leading for downdraft, and with the downturned edge leading for updraft. Hunter's "Adaptair" mechanism is perhaps the most well-known example of mechanical reversibility.

For cooling, the fan's direction of rotation should usually be set so that air is blown downwardusually counter-clockwise from beneath, but dependent upon manufacturer. The blades should lead with the upturned edge as they spin. The breeze created by a ceiling fan creates a wind chill effect, speeding the evaporation of perspiration on human skin, which makes the body's natural cooling mechanism much more efficient. As a result of this phenomenon, the air conditioning thermostat can be set a few degrees higher than normal when a fan is in operation, greatly reducing power consumption. Since the fan works directly on the body, rather than by changing the temperature of the air, it is recommended to switch all ceiling fans off when a room is unoccupied, to further reduce power consumption. In some cases, like when a fan is near walls like in a hallway, updraft may cause better airflow. Another example of how updraft can cause better cooling is when the ceiling fan is in middle of a bedroom with a loft bed near a wall, meaning breeze can be felt better when airflow is coming from the top.

For heating, ceiling fans should be set to blow the air upward. Air naturally stratifies, i.e. warmer air rises to the ceiling while cooler air sinks, meaning that colder air settles near the floor where people spend most of their time. A ceiling fan, with its direction of rotation set so that the warmer air on the ceiling is pushed down along the walls and into the room, heating the cooler air. This avoids blowing a stream of air directly at the occupants of the room, which would tend to cool them. This action works to equalize, or even out the temperature in the room, making it cooler at ceiling level, but warmer near the floor. Thus the heating thermostat in the area can be set a few degrees lower to save energy while maintaining the same level of comfort.

Though reversible models of industrial-grade ceiling fans do exist, most are not reversible. High ceiling heights in most industrial applications render reversibility unnecessary. Instead, industrial ceiling fans typically de-stratify heat by blowing hot air at ceiling level directly down toward the floor.

Blade shape

Residential ceiling fans, which are almost always reversible, typically use flat, paddle-like blades, which are equally effective in downdraft and updraft. Industrial ceiling fans typically are not reversible and operate only in downdraft, and therefore are able to make effective use of blades that are contoured to have a downdraft bias.

More recently, however, residential ceiling fan designers have been making increasing use of contoured blades in an effort to boost ceiling fan efficiency. This contour, while serving to effectively boost the fan's performance while operating in downdraft, can hinder performance when operating in updraft.

Air conditioning

The most commonplace use of ceiling fans today is in conjunction with an air conditioning unit. Without an operating ceiling fan, air conditioning units typically have both the tasks of cooling the air inside the room and circulating it. Provided the ceiling fan is properly sized for the room in which it is operating, its efficiency of moving air far exceeds that of an air conditioning unit, therefore, for peak efficiency, the air conditioner should be set to a low fan setting and the ceiling fan should be used to circulate the air.

Flicker and strobing

Ceiling fans are usually installed in a space with other lighting fixtures, but if the fan is positioned too close to a light panel or fixture, a strobe or flicker effect may occur. A strobe or flicker effect is a phenomenon which occurs when light brightens and dims consistently as it penetrates and passes through a moving ceiling fan. [8] This is due to the fan blades intermittently blocking the light, causing shadows to appear across the room's interior surface leading to visual discomfort. The rotating area of a moving fan blade can commonly obstruct the light source when a ceiling fan is positioned underneath an artificial lighting fixture, which can be increasingly distracting to occupants within the space. [9] To ensure that the ceiling fans seamlessly co-exists with the lighting fixtures to avoid strobing, it is recommended that the horizontal separation between the blade and the lighting fixture is maximized. In addition, increasing the vertical distance between the light and the blade will reduce the concentration and frequency of strobing. Never position a light fixture directly above a ceiling fan's blades, and downlight and point source fixtures should be set such that their beam angles don't cross them. Generally, to ensure uniformly adequate light levels, any recessed ceiling lighting and fixtures that emit light above the level of the fan blades should be placed as far away from the ceiling fan as possible. [10] Another recommended strategy is to ensure that the light’s angle of dispersion or the field angle is reduced, which minimizes the strobing effect from the fan blades. It is well known that human eyes can detect flicker at low frequencies (between 60 and 90 hertz), but not at high frequencies (beyond 100 hertz), which is also known as non-visible flicker. The strobe effect can have significant physiological and psychological effect on humans. [11] Two test rooms were utilized in an experiment to compare the effects of visual flicker induced the ceiling fan. The findings revealed statistical proof that one out of three cognitive performances (digit-span task) may have been reduced slightly as a result of an increased effect of visual flicker. [12]

Parts

The key components of a ceiling fan are the following:

     Some ball-and-socket fans can be mounted using a low-ceiling adapter, purchased specially from the fan's manufacturer. This allows the same design to be used in both a high and low ceiling environment, simplifying the buying decision for consumers. In recent years, it has become increasingly common for a ball-and-socket fan to be designed such that the canopy (ceiling cover piece) can optionally be screwed directly into the top of the motor housing, thus eliminating the need for a downrod. The whole fan can be secured directly onto the ceiling mounting bracket; this is often referred to as a dual-mount or tri-mount.

Other components, which vary by model and style, can include:

Operation

A modern pull-chain operated ceiling fan with its light on Modern ceiling fan.jpg
A modern pull-chain operated ceiling fan with its light on

The way in which a fan is operated depends on its manufacturer, style, and the era in which it was made. Operating methods include:

Old-style choke and new-style capacitor based wall control Ceiling fan wall control types.jpg
Old-style choke and new-style capacitor based wall control

Classifications

Ceiling fans can be classified into three main categories based on their use and functionality. Each type offers some unique advantages over the others and hence is suitable for a specific application. These include household, industrial and large-diameter fans.

A 5-blade ceiling fan in a restaurant. Restaurant Ceiling Fan.jpg
A 5-blade ceiling fan in a restaurant.
A High-volume low-speed fan HVLS wood ceiling.jpg
A High-volume low-speed fan

Types

Many styles of ceiling fans have been developed over the years in response to several different factors such as growing energy-consumption consciousness and changes in decorating styles. The advent and evolution of new technologies have also played a major role in ceiling fan development. Following is a list of major ceiling fan styles and their defining characteristics:

A cast-iron ceiling fan made by Hunter, dating from the early 1980s. This model is called the "Original". Hunter Original.jpg
A cast-iron ceiling fan made by Hunter, dating from the early 1980s. This model is called the "Original".
The Emerson "Heat Fan", the first ceiling fan to use a stack motor Emerson Universal.jpg
The Emerson "Heat Fan", the first ceiling fan to use a stack motor
A close-up of the dropped flywheel on a FASCO "Charleston" ceiling fan Fasco charleston flywheel.jpg
A close-up of the dropped flywheel on a FASCO "Charleston" ceiling fan
A spinner fan with light kit Spinner fan.jpg
A spinner fan with light kit
A modern three blade spinner fan from India White Ceiling fan.jpg
A modern three blade spinner fan from India
Three fans driven by a single motor and belts Registrator output.png
Three fans driven by a single motor and belts
Orbit fans inside a train in Sri Lanka. Ventilateurs de train-Sri Lanka (2).jpg
Orbit fans inside a train in Sri Lanka.

Effects on Airborne Transmission & Distribution

Ceiling fans provide a more affordable and energy-efficient alternative to air-conditioning, especially when used in conjunction with warmer room air temperature. Overall, the use of ceiling fans results in a lesser impact on global warming when looking at carbon generation suppression. [20] In addition to improving thermal comfort and reducing energy consumption from air-conditioning, ceiling fans have been studied as a tool that could potentially affect airborne transmission and distribution. This is important, for the risk of aerosol transmission in poorly ventilated places is much higher as proven by cases in hospital wards, restaurants, and offices. According to an experiment using tracer gas it was found that ceiling fans could reduce the exposure risk of the breathing ozone by 20%. [21] Another study found that with better aerosols’ dispersion through mixing air and creating local air movements, the ceiling fan operation reduced the exposed individual’s breathing ozone concentrations by more than 20%. [22] Airflow patterns generated from ceiling fans recirculates air vertically because ceiling fans generate inflow from overhead which creates an air distribution that is different from the typical wind which has horizontal flow directions. Ceiling fan airflow has a greater effect than supply air on aerosol transmission because the downward movement of the ceiling fan’s airflow can protect the underneath subject from exposure than when the subject was further from the fan. In a study comparing the airflow of ceiling fans to the supply air of diffusers, ceiling fans were proven to have a more significant effect on the droplet and airborne transmission, for it achieved a stronger protection for the subject under cough exposure. [23] The research proved that ceiling fans showed strong potential to reduce the exposure risk to coughs that directed horizontally through the transient process.

Safety concerns with installation

A typical ceiling fan weighs between 3.6 and 22.7 kg when fully assembled. While many junction boxes can support that weight while the fan is hanging still, a fan in operation exerts many additional stresses—notably torsion—on the object from which it is hung; this can cause an improper junction box to fail. For this reason, in the United States the National Electric Code (document NFPA 70, Article 314) states that ceiling fans must be supported by an electrical junction box listed for that use. It is a common mistake for homeowners to replace a light fixture with a ceiling fan without upgrading to a proper junction box[ citation needed ]. Ultimately, the weight of the fan must be carried by a strong structural element of the ceiling, such as a ceiling joist. Should an improperly mounted fan fall, especially a 22.7 kg cast iron fan, the result could be catastrophic.

Low-hanging fans/danger to limbs

Another concern with installing a ceiling fan relates to the height of the blades relative to the floor. Building codes throughout the United States prohibit residential ceiling fans from being mounted with the blades closer than seven feet from the floor;[ citation needed ] this sometimes proves, however, to not be high enough. If a ceiling fan is turned on and a person fully extends his or her arms into the air, as sometimes happens during normal tasks such as dressing, stretching or changing bedsheets, it is possible for the blades to strike their hands, potentially causing injury. Also, if one is carrying a long and awkward object, one end may inadvertently enter the path of rotation of a ceiling fan's blades, which can cause damage to the fan. Building codes throughout the United States also prohibit industrial ceiling fans from being mounted with the blades closer than 10 feet from the floor for these reasons.

In other countries, ceiling fans usually come with a warning to install the fan so that the blades are 2.3 meters above the floor or higher, as instructed by the IEC and similar bodies. This rule applies to all "high level fans" [24] including but not limited to ceiling fans.

In Australia, [25] building codes require fans to be mounted at least 2.1 meters high.

MythBusters: "Killer Ceiling Fan"

In 2004, MythBusters tested the idea that a ceiling fan is capable of decapitation if an individual was to stick his or her neck into a running fan. Two versions of the myth were tested, with the first being the "jumping kid", involving a kid jumping up and down on a bed, jumping too high and entering the fan from below and the second being the "lover's leap", involving a husband leaping towards his bed and entering the fan side-on. Kari Byron and Scottie Chapman purchased a regular household fan and also an industrial fan, which has metal blades as opposed to wood and a more powerful motor. They busted the myth in both scenarios with both household and industrial fans, as tests proved that residential ceiling fans are, apparently by design, largely incapable of causing more than a minor injury, having low-torque motors that stop quickly when blocked and blades composed of light materials that tend to break easily if impacted at speed (the household fan test of the "lover's leap" scenario actually broke the fan blades.) They did find that industrial fans, with their steel blades and higher speeds, proved capable of causing injury and laceration - building codes require industrial fans to be mounted with blades 3.048 m above the floor, and the industrial fan test of the "lover's leap" scenario produced a lethal injury where the fan sliced through the jugular and into the vertebrae - but still lost energy rapidly once blocked and were unable to decapitate the test dummy. [26]

Wobble

Wobbling is usually caused by the weight of fan blades being out of balance with each other.[ citation needed ] This can happen due to a variety of factors, including blades being warped, blade irons being bent, blades or blade irons not being screwed on straight, or weight variation between blades. Also, if all the blades do not exert an equal force on the air (because they have different angles, for instance), the vertical reaction forces can cause wobbling. Wobble can also be caused by a motor flaw, but that very rarely occurs. Wobbling is not affected by the way in which the fan is mounted or the mounting surface.

Contrary to popular misconception, wobbling alone will not cause a ceiling fan to fall. [27] Ceiling fans are secured by clevis pins locked with either split pins or R-clips, so wobbling will not have an effect on the fan's security, unless of course, the pins/clips were not secured. To date, there are no reports of a fan wobbling itself off the ceiling and falling. However, a severe wobble can cause light fixture shades or covers to gradually loosen over time and potentially fall, posing a risk of injury to anyone under the fan, and also from any resulting broken glass. When the MythBusters were designing a fan with the goal of chopping off someone's head, Scottie used an edge finder to find the exact center of their blades with the aim of eliminating potentially very dangerous wobbling of their steel blades.

Wobbling may be reduced by measuring the tip of each blade from a fixed point on the ceiling (or floor) and ensuring each is equal. If the fan has a metal plate between the motor and blade, this may be gently adjusted by bending. It can also be reduced by making sure all blades have the same pitch, and all blades have the same distance from adjacent blades. It can also be reduced by having balancing weight on the blades.

Even a very slight wobble can also cause a pull chain to swing, if fan is at right RPM, and as the pull chain swings, it can weaken the part that flexes, which can eventually cause it to break, meaning that a pull chain can fall on someone.

Wobble in some case can cause wires inside the motor to wriggle, and then eventually reach the top of the motor, which can then yank the wires out of the windings. That is fixable, but it may not be very easy to fix.

Humming

Humming is often caused by using a dimmer switch or a solid state speed control (those are usually made for industrial setting where humming noise is acceptable) to control the fan speed, since those controls cause chopping current, which causes windings to vibrate. [28] Humming can also be caused by a bad start/run capacitor, or a capacitor with a wrong capacitance size for the motor. A bad or wrong start/run capacitor causes the winding current phase on main windings and auxiliary windings to not sync properly and can cause a hum. Also, humming may be reduced by having windings varnished.

See also

Related Research Articles

<span class="mw-page-title-main">Uninterruptible power supply</span> Electrical device that uses batteries to prevent any interruption of power flow

An uninterruptible power supply (UPS) or uninterruptible power source is a type of continual power system that provides automated backup electric power to a load when the input power source or mains power fails. A UPS differs from a traditional auxiliary/emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions by switching to energy stored in battery packs, supercapacitors or flywheels. The on-battery run-times of most UPSs are relatively short but sufficient to "buy time" for initiating a standby power source or properly shutting down the protected equipment. Almost all UPSs also contain integrated surge protection to shield the output appliances from voltage spikes.

<span class="mw-page-title-main">Electric motor</span> Machine that converts electrical energy into mechanical energy

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force in the form of torque applied on the motor's shaft. An electric generator is mechanically identical to an electric motor, but operates in reverse, converting mechanical energy into electrical energy.

<span class="mw-page-title-main">Starter (engine)</span> Device used to start an internal combustion engine

A starter is a device used to rotate (crank) an internal-combustion engine so as to initiate the engine's operation under its own power. Starters can be electric, pneumatic, or hydraulic. The starter can also be another internal-combustion engine in the case, for instance, of very large engines, or diesel engines in agricultural or excavation applications.

<span class="mw-page-title-main">Quiet PC</span> Type of personal computer

A quiet, silent or fanless PC is a personal computer that makes very little or no noise. Common uses for quiet PCs include video editing, sound mixing and home theater PCs, but noise reduction techniques can also be used to greatly reduce the noise from servers. There is currently no standard definition for a "quiet PC", and the term is generally not used in a business context, but by individuals and the businesses catering to them.

<span class="mw-page-title-main">Lawn mower</span> Grass cutting device

A lawn mower is a device utilizing one or more revolving blades to cut a grass surface to an even height. The height of the cut grass may be fixed by the design of the mower but generally is adjustable by the operator, typically by a single master lever or by a mechanism on each of the machine's wheels. The blades may be powered by manual force, with wheels mechanically connected to the cutting blades so that the blades spin when the mower is pushed forward, or the machine may have a battery-powered or plug-in electric motor. The most common self-contained power source for lawn mowers is a small internal combustion engine. Smaller mowers often lack any form of self-propulsion, requiring human power to move over a surface; "walk-behind" mowers are self-propelled, requiring a human only to walk behind and guide them. Larger lawn mowers are usually either self-propelled "walk-behind" types or, more often, are "ride-on" mowers that the operator can sit on and control. A robotic lawn mower is designed to operate either entirely on its own or less commonly by an operator on a remote control.

<span class="mw-page-title-main">Compressor</span> Machine to increase pressure of gas by reducing its volume

A compressor is a mechanical device that increases the pressure of a gas by reducing its volume. An air compressor is a specific type of gas compressor.

A motor controller is a device or group of devices that can coordinate in a predetermined manner the performance of an electric motor. A motor controller might include a manual or automatic means for starting and stopping the motor, selecting forward or reverse rotation, selecting and regulating the speed, regulating or limiting the torque, and protecting against overloads and electrical faults. Motor controllers may use electromechanical switching, or may use power electronics devices to regulate the speed and direction of a motor.

<span class="mw-page-title-main">Brushless DC electric motor</span> Synchronous electric motor powered by an inverter

A brushless DC electric motor (BLDC), also known as an electronically commutated motor, is a synchronous motor using a direct current (DC) electric power supply. It uses an electronic controller to switch DC currents to the motor windings producing magnetic fields that effectively rotate in space and which the permanent magnet rotor follows. The controller adjusts the phase and amplitude of the current pulses that control the speed and torque of the motor. It is an improvement on the mechanical commutator (brushes) used in many conventional electric motors.

<span class="mw-page-title-main">DC motor</span> Motor which works on direct current

A DC motor is an electrical motor that uses direct current (DC) to produce mechanical force. The most common types rely on magnetic forces produced by currents in the coils. Nearly all types of DC motors have some internal mechanism, either electromechanical or electronic, to periodically change the direction of current in part of the motor.

<span class="mw-page-title-main">Motor–generator</span> Device for converting electrical power to another form

A motor–generator is a device for converting electrical power to another form. Motor–generator sets are used to convert frequency, voltage, or phase of power. They may also be used to isolate electrical loads from the electrical power supply line. Large motor–generators were widely used to convert industrial amounts of power while smaller motor–generators were used to convert battery power to higher DC voltages.

<span class="mw-page-title-main">Air handler</span> Device used to regulate and circulate air as part of an HVAC system

An air handler, or air handling unit, is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, furnace or A/C elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU, sometimes exhausting air to the atmosphere and bringing in fresh air. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork

<span class="mw-page-title-main">Motor drive</span> Piece of machine equipment

Motor drive means a system that includes a motor. An adjustable speed motor drive means a system that includes a motor that has multiple operating speeds. A variable speed motor drive is a system that includes a motor and is continuously variable in speed. If the motor is generating electrical energy rather than using it – this could be called a generator drive but is often still referred to as a motor drive.

<span class="mw-page-title-main">Light fixture</span> Electrical device with an electric lamp

A light fixture, light fitting, or luminaire is an electrical lighting device containing one or more light sources, such as lamps, and all the accessory components required for its operation to provide illumination to the environment. All light fixtures have a fixture body and one or more lamps. The lamps may be in sockets for easy replacement—or, in the case of some LED fixtures, hard-wired in place.

<span class="mw-page-title-main">Fluid coupling</span> Device used to transmit rotating mechanical power

A fluid coupling or hydraulic coupling is a hydrodynamic or 'hydrokinetic' device used to transmit rotating mechanical power. It has been used in automobile transmissions as an alternative to a mechanical clutch. It also has widespread application in marine and industrial machine drives, where variable speed operation and controlled start-up without shock loading of the power transmission system is essential.

<span class="mw-page-title-main">Centrifugal fan</span> Mechanical fan that forces fluid to move radially outward

A centrifugal fan is a mechanical device for moving air or other gases in a direction at an angle to the incoming fluid. Centrifugal fans often contain a ducted housing to direct outgoing air in a specific direction or across a heat sink; such a fan is also called a blower, blower fan, or squirrel-cage fan. Tiny ones used in computers are sometimes called biscuit blowers. These fans move air from the rotating inlet of the fan to an outlet. They are typically used in ducted applications to either draw air through ductwork/heat exchanger, or push air through similar impellers. Compared to standard axial fans, they can provide similar air movement from a smaller fan package, and overcome higher resistance in air streams.

<span class="mw-page-title-main">Fan (machine)</span> Machine used to produce air flow

A fan is a powered machine used to create a flow of air. A fan consists of a rotating arrangement of vanes or blades, generally made of wood, plastic, or metal, which act on the air. The rotating assembly of blades and hub is known as an impeller, rotor, or runner. Usually, it is contained within some form of housing, or case. This may direct the airflow, or increase safety by preventing objects from contacting the fan blades. Most fans are powered by electric motors, but other sources of power may be used, including hydraulic motors, handcranks, and internal combustion engines.

Industrial fans and blowers are machines whose primary function is to provide and accommodate a large flow of air or gas to various parts of a building or other structures. This is achieved by rotating a number of blades, connected to a hub and shaft, and driven by a motor or turbine. The flow rates of these mechanical fans range from approximately 200 cubic feet (5.7 m3) to 2,000,000 cubic feet (57,000 m3) per minute. A blower is another name for a fan that operates where the resistance to the flow is primarily on the downstream side of the fan.

<span class="mw-page-title-main">Fan coil unit</span> HVAC device

A fan coil unit (FCU), also known as a Vertical Fan Coil-Unit (VFC), is a device consisting of a heat exchanger (coil) and a fan. FCUs are commonly used in HVAC systems of residential, commercial, and industrial buildings that use ducted split air conditioning or with central plant cooling. FCUs are typically connected to ductwork and a thermostat to regulate the temperature of one or more spaces and to assist the main air handling unit for each space if used with chillers. The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve.

Casablanca Fan Company is a ceiling fan company currently based in Memphis, Tennessee. In the late 1970s, the company became known for their premium fans, which were marketed as furniture.

References

  1. "Punkah. hand-operated hanging fan the colonial legacy".
  2. 1 2 3 Scharff, Robert; Casablanca Fan Co. (1983). The Fan Book . Reston, VA: Reston Publishing. p.  128. ISBN   0-8359-1855-6.
  3. Dane Roger, Patricia (June 14, 2001). "Eye on Design". The Washington Post. p. H5.
  4. Arens, Edward; Turner, Stephen; Zhang, Hui (2009). "Moving Air for Comfort" (PDF). ASHRAE. Journal 51: 18–28.
  5. Schiavon, Stefano; Melikov, Arsen K. (January 2008). "Energy saving and improved comfort by increased air movement". Energy and Buildings. 40 (10): 1954–1960. doi:10.1016/j.enbuild.2008.05.001. S2CID   55323785.
  6. 1 2 Lipczynska, Aleksandra; Schiavon, Stefano; Graham, Lindsay T. (May 2018). "Thermal comfort and self-reported productivity in an office with ceiling fans in the tropics". Building and Environment. 135: 202–212. Bibcode:2018BuEnv.135..202L. doi:10.1016/j.buildenv.2018.03.013. S2CID   55365037.
  7. Song, Jiafang; Meng, Xiangquan (2015). "The Improvement of Ventilation Design in School Buildings Using CFD Simulation". Procedia Engineering. 121: 1475–1481. doi: 10.1016/j.proeng.2015.09.073 .
  8. MK Think (2017). "Ceiling Fan Study: Literature and Market Report" (PDF). Hawaii Natural Energy Institute: 50–51.
  9. US4382400A,Stutzman, Clarence,"Combined ceiling mounted fan and lighting fixture",issued 1983-05-10
  10. Raftery, Paul; Douglass-Jaimes, David (March 1, 2020). "Ceiling Fan Design Guide". Center for the Built Environment .
  11. Yang, Jin; Zhang, Tianchi; Lin, Yandan; Xu, Wei (November 2019). "Effect of Illuminance and Light Strobe on Attention and Visual Fatigue in Indoor Lighting". 2019 16th China International Forum on Solid State Lighting & 2019 International Forum on Wide Bandgap Semiconductors China (SSLChina: IFWS). pp. 149–152. doi:10.1109/SSLChinaIFWS49075.2019.9019810. ISBN   978-1-7281-5756-6. S2CID   212637051.
  12. Kent, Michael G.; Cheung, Toby; Li, Jiayu; Schiavon, Stefano (September 1, 2020). "Experimental evaluation of visual flicker caused by ceiling fans". Building and Environment. 182: 107060. doi:10.1016/j.buildenv.2020.107060. ISSN   0360-1323. S2CID   225305290.
  13. ETechnoG, Team (April 15, 2021). "Electrical(Old) VS Electronic(New) Fan Regulator". ETechnoG - Electrical, Electronics and Technology. Retrieved December 10, 2022.
  14. "How Many Ceiling Fans On a 20 Amp Circuit?". April 13, 2022.
  15. "Ceiling fan direction". LampsUSA. Retrieved April 4, 2018.
  16. "Indoor vs. Outdoor Ceiling Fans: A Where to Use Guide". DelMarFans.
  17. "How does the Exhale Fan work?". Exhale Fans Europe.
  18. "DC vs AC Ceiling Fans". www.hunterfan.co.uk. Archived from the original on February 21, 2015. Retrieved May 25, 2015.
  19. "Best 7 Smart Ceiling Fans 2020: Google, Alexa and Wifi". Smart Living Advice. September 29, 2019.
  20. Nair, Ajith N.; Anand, Prashant; George, Abraham; Mondal, Nilabhra (October 1, 2022). "A review of strategies and their effectiveness in reducing indoor airborne transmission and improving indoor air quality". Environmental Research. 213: 113579. Bibcode:2022ER....213k3579N. doi:10.1016/j.envres.2022.113579. ISSN   0013-9351. PMC   9192357 . PMID   35714688.
  21. Li, Wenxin; Chong, Adrian; Hasama, Takamasa; Xu, Lei; Lasternas, Bertrand; Tham, Kwok Wai; Lam, Khee Poh (July 2021). "Effects of ceiling fans on airborne transmission in an air-conditioned space". Building and Environment. 198: 107887. doi:10.1016/j.buildenv.2021.107887. ISSN   0360-1323. S2CID   235512203.
  22. Hasama, Takamasa; Mihara, Kuniaki; Sekhar, Chandra; Cheong, Kok Wai David; Tham, Kwok Wai (April 15, 2022). "Assessment of airflow and heat transfer around a thermal manikin in a premise served by DOAS and ceiling fans". Building and Environment. 214: 108902. doi:10.1016/j.buildenv.2022.108902. ISSN   0360-1323. S2CID   246978246.
  23. Li, Wenxin; Hasama, Takamasa; Chong, Adrian; Hang, Joo Guan; Lasternas, Bertrand; Lam, Khee Poh; Tham, Kwok Wai (November 14, 2022). "Transient Transmissions of Droplets and Aerosols in Ventilation Systems with Ceiling Fans". Social Science Research Network . Rochester, NY. SSRN   4269544.
  24. "CB TEST CERTIFICATE".
  25. "Information & Tips - Fans FAQ Section". Universal Fans. Retrieved March 20, 2023.
  26. Savage, Adam; Hyneman, Jamie; Chapman, Scottie; Belleci, Tory; Byron, Kari (December 5, 2004). "Ming Dynasty Astronaut". MythBusters. Season 2. Episode 24. Begins at 25:45. Discovery.
  27. Gromicko, Nick. "Ceiling Fan Inspection". International Association of Certified Home Inspectors. Retrieved May 31, 2013.
  28. superacademy (November 17, 2022). "Super Inspector Finds Noisy Ceiling Fan -" . Retrieved October 13, 2023.