The voltage clamp operates by negative feedback. The membrane potential amplifier measures membrane voltage and sends output to the feedback amplifier; this subtracts the membrane voltage from the command voltage, which it receives from the signal generator. This signal is amplified and output is sent into the axon via the current-passing electrode. Voltage clamp setup.svg
The voltage clamp operates by negative feedback. The membrane potential amplifier measures membrane voltage and sends output to the feedback amplifier; this subtracts the membrane voltage from the command voltage, which it receives from the signal generator. This signal is amplified and output is sent into the axon via the current-passing electrode.

The voltage clamp is an experimental method used by electrophysiologists to measure the ion currents through the membranes of excitable cells, such as neurons, while holding the membrane voltage at a set level. [1] A basic voltage clamp will iteratively measure the membrane potential, and then change the membrane potential (voltage) to a desired value by adding the necessary current. This "clamps" the cell membrane at a desired constant voltage, allowing the voltage clamp to record what currents are delivered. Because the currents applied to the cell must be equal to (and opposite in charge to) the current going across the cell membrane at the set voltage, the recorded currents indicate how the cell reacts to changes in membrane potential. [2] Cell membranes of excitable cells contain many different kinds of ion channels, some of which are voltage-gated. The voltage clamp allows the membrane voltage to be manipulated independently of the ionic currents, allowing the current–voltage relationships of membrane channels to be studied. [3]

Contents

History

The concept of the voltage clamp is attributed to Kenneth Cole [4] and George Marmont [5] in the spring of 1947. [6] They inserted an internal electrode into the giant axon of a squid and began to apply a current. Cole discovered that it was possible to use two electrodes and a feedback circuit to keep the cell's membrane potential at a level set by the experimenter.

Cole developed the voltage clamp technique before the era of microelectrodes, so his two electrodes consisted of fine wires twisted around an insulating rod. Because this type of electrode could be inserted into only the largest cells, early electrophysiological experiments were conducted almost exclusively on squid axons.

A personal photo of Kenneth Cole, given to Dr. J. Walter Woodbury Authorized Kenneth Cole Picture.jpg
A personal photo of Kenneth Cole, given to Dr. J. Walter Woodbury

Squids squirt jets of water when they need to move quickly, as when escaping a predator. To make this escape as fast as possible, they have an axon that can reach 1 mm in diameter (signals propagate more quickly down large axons). The squid giant axon was the first preparation that could be used to voltage clamp a transmembrane current, and it was the basis of Hodgkin and Huxley's pioneering experiments on the properties of the action potential. [6]

Alan Hodgkin realized that, to understand ion flux across the membrane, it was necessary to eliminate differences in membrane potential. [7] Using experiments with the voltage clamp, Hodgkin and Andrew Huxley published 5 papers in the summer of 1952 describing how ionic currents give rise to the action potential. [8] The final paper proposed the Hodgkin–Huxley model which mathematically describes the action potential. The use of voltage clamps in their experiments to study and model the action potential in detail has laid the foundation for electrophysiology; for which they shared the 1963 Nobel Prize in Physiology or Medicine. [7]

Technique

The voltage clamp is a current generator. Transmembrane voltage is recorded through a "voltage electrode", relative to ground, and a "current electrode" passes current into the cell. The experimenter sets a "holding voltage", or "command potential", and the voltage clamp uses negative feedback to maintain the cell at this voltage. The electrodes are connected to an amplifier, which measures membrane potential and feeds the signal into a feedback amplifier. This amplifier also gets an input from the signal generator that determines the command potential, and it subtracts the membrane potential from the command potential (Vcommand – Vm), magnifies any difference, and sends an output to the current electrode. Whenever the cell deviates from the holding voltage, the operational amplifier generates an "error signal", that is the difference between the command potential and the actual voltage of the cell. The feedback circuit passes current into the cell to reduce the error signal to zero. Thus, the clamp circuit produces a current equal and opposite to the ionic current.

Variations of the voltage clamp technique

Two-electrode voltage clamp using microelectrodes

Two-electrode voltage clamp Tevcimage.jpg
Two-electrode voltage clamp

The two-electrode voltage clamp (TEVC) technique is used to study properties of membrane proteins, especially ion channels. [9] Researchers use this method most commonly to investigate membrane structures expressed in Xenopus oocytes. The large size of these oocytes allows for easy handling and manipulability. [10]

The TEVC method utilizes two low-resistance pipettes, one sensing voltage and the other injecting current. The microelectrodes are filled with conductive solution and inserted into the cell to artificially control membrane potential. The membrane acts as a dielectric as well as a resistor, while the fluids on either side of the membrane function as capacitors. [10] The microelectrodes compare the membrane potential against a command voltage, giving an accurate reproduction of the currents flowing across the membrane. Current readings can be used to analyze the electrical response of the cell to different applications.

This technique is favored over single-microelectrode clamp or other voltage clamp techniques when conditions call for resolving large currents. The high current-passing capacity of the two-electrode clamp makes it possible to clamp large currents that are impossible to control with single-electrode patch techniques. [11] The two-electrode system is also desirable for its fast clamp settling time and low noise. However, TEVC is limited in use with regard to cell size. It is effective in larger-diameter oocytes, but more difficult to use with small cells. Additionally, TEVC method is limited in that the transmitter of current must be contained in the pipette. It is not possible to manipulate the intracellular fluid while clamping, which is possible using patch clamp techniques. [2] Another disadvantage involves "space clamp" issues. Cole's voltage clamp used a long wire that clamped the squid axon uniformly along its entire length. TEVC microelectrodes can provide only a spatial point source of current that may not uniformly affect all parts of an irregularly shaped cell.

Dual-cell voltage clamp

The dual-cell voltage clamp technique is a specialized variation of the two electrode voltage clamp, and is only used in the study of gap junction channels. [12] Gap junctions are pores that directly link two cells through which ions and small molecules flow freely. When two cells in which gap junction proteins, typically connexins or innexins, are expressed, either endogenously or via injection of mRNA, a junction channel will form between the cells. Since two cells are present in the system, two sets of electrodes are used. A recording electrode and a current injecting electrode are inserted into each cell, and each cell is clamped individually (each set of electrodes is attached to a separate apparatus, and integration of data is performed by computer). To record junctional conductance, the current is varied in the first cell while the recording electrode in the second cell records any changes in Vm for the second cell only. (The process can be reversed with the stimulus occurring in the second cell and recording occurring in the first cell.) Since no variation in current is being induced by the electrode in the recorded cell, any change in voltage must be induced by current crossing into the recorded cell, through the gap junction channels, from the cell in which the current was varied. [12]

Single-electrode voltage clamp

This category describes a set of techniques in which one electrode is used for voltage clamp. Continuous single-electrode clamp (SEVC-c) technique is often used with patch-clamp recording. Discontinuous single-electrode voltage-clamp (SEVC-d) technique is used with penetrating intracellular recording. This single electrode carries out the functions of both current injection and voltage recording.

Continuous single-electrode clamp (SEVC-c)

The "patch-clamp" technique allows the study of individual ion channels. It uses an electrode with a relatively large tip (> 1 micrometer) that has a smooth surface (rather than a sharp tip). This is a "patch-clamp electrode" (as distinct from a "sharp electrode" used to impale cells). This electrode is pressed against a cell membrane and suction is applied to pull the cell's membrane inside the electrode tip. The suction causes the cell to form a tight seal with the electrode (a "gigaohm seal", as the resistance is more than a gigaohm).

SEV-c has the advantage that you can record from small cells that would be impossible to impale with two electrodes. However:

  1. Microelectrodes are imperfect conductors; in general, they have a resistance of more than a million ohms. They rectify (i.e., change their resistance with voltage, often in an irregular manner), they sometimes have unstable resistance if clogged by cell contents. Thus, they will not faithfully record the voltage of the cell, especially when it is changing quickly, nor will they faithfully pass current.
  2. Voltage and current errors: SEV-c circuitry does not actually measure the voltage of the cell being clamped (as does a two-electrode clamp). The patch-clamp amplifier is like a two-electrode clamp, except the voltage measuring and current passing circuits are connected (in the two-electrode clamp, they are connected through the cell). The electrode is attached to a wire that contacts the current/voltage loop inside the amplifier. Thus, the electrode has only an indirect influence on the feedback circuit. The amplifier reads only the voltage at the top of the electrode, and feeds back current to compensate. But, if the electrode is an imperfect conductor, the clamp circuitry has only a distorted view of the membrane potential. Likewise, when the circuit passes back current to compensate for that (distorted) voltage, the current will be distorted by the electrode before it reaches the cell. To compensate for this, the electrophysiologist uses the lowest resistance electrode possible, makes sure that the electrode characteristics do not change during an experiment (so the errors will be constant), and avoids recording currents with kinetics likely to be too fast for the clamp to follow accurately. The accuracy of SEV-c goes up the slower and smaller are the voltage changes it is trying to clamp.
  3. Series resistance errors: The currents passed to the cell must go to ground to complete the circuit. The voltages are recorded by the amplifier relative to ground. When a cell is clamped at its natural resting potential, there is no problem; the clamp is not passing current and the voltage is being generated only by the cell. But, when clamping at a different potential, series resistance errors become a concern; the cell will pass current across its membrane in an attempt to return to its natural resting potential. The clamp amplifier opposes this by passing current to maintain the holding potential. A problem arises because the electrode is between the amplifier and the cell; i.e., the electrode is in series with the resistor that is the cell's membrane. Thus, when passing current through the electrode and the cell, Ohm's Law tells us that this will cause a voltage to form across both the cell's and the electrode's resistance. As these resistors are in series, the voltage drops will add. If the electrode and the cell membrane have equal resistances (which they usually do not), and if the experimenter command a 40mV change from the resting potential, the amplifier will pass enough current until it reads that it has achieved that 40mV change. However, in this example, half of that voltage drop is across the electrode. The experimenter thinks he or she has moved the cell voltage by 40 mV, but has moved it only by 20 mV. The difference is the "series resistance error". Modern patch-clamp amplifiers have circuitry to compensate for this error, but these compensate only 70-80% of it. The electrophysiologist can further reduce the error by recording at or near the cell's natural resting potential, and by using as low a resistance electrode as possible.
  4. Capacitance errors. Microelectrodes are capacitors, and are particularly troublesome because they are non-linear. The capacitance arises because the electrolyte inside the electrode is separated by an insulator (glass) from the solution outside. This is, by definition and function, a capacitor. Worse, as the thickness of the glass changes the farther you get from the tip, the time constant of the capacitor will vary. This produces a distorted record of membrane voltage or current whenever they are changing. Amplifiers can compensate for this, but not entirely because the capacitance has many time-constants. The experimenter can reduce the problem by keeping the cell's bathing solution shallow (exposing less glass surface to liquid) and by coating the electrode with silicone, resin, paint, or another substance that will increase the distance between the inside and outside solutions.
  5. Space clamp errors. A single electrode is a point source of current. In distant parts of the cell, the current passed through the electrode will be less influential than at nearby parts of the cell. This is particularly a problem when recording from neurons with elaborate dendritic structures. There is nothing one can do about space clamp errors except to temper the conclusions of the experiment.

Discontinuous single-electrode voltage-clamp (SEVC-d)

A single-electrode voltage clamp discontinuous, or SEVC-d, has some advantages over SEVC-c for whole-cell recording. In this, a different approach is taken for passing current and recording voltage. A SEVC-d amplifier operates on a "time-sharing" basis, so the electrode regularly and frequently switches between passing current and measuring voltage. In effect, there are two electrodes, but each is in operation for only half of the time it is on. The oscillation between the two functions of the single electrode is termed a duty cycle. During each cycle, the amplifier measures the membrane potential and compares it with the holding potential. An operational amplifier measures the difference, and generates an error signal. This current is a mirror image of the current generated by the cell. The amplifier outputs feature sample and hold circuits, so each briefly sampled voltage is then held on the output until the next measurement in the next cycle. To be specific, the amplifier measures voltage in the first few microseconds of the cycle, generates the error signal, and spends the rest of the cycle passing current to reduce that error. At the start of the next cycle, voltage is measured again, a new error signal generated, current passed etc. The experimenter sets the cycle length, and it is possible to sample with periods as low as about 15 microseconds, corresponding to a 67 kHz switching frequency. Switching frequencies lower than about 10 kHz are not sufficient when working with action potentials that are less than 1 millisecond wide. Note that not all discontinuous voltage-clamp amplifier support switching frequencies higher than 10 kHz. [10]

For this to work, the cell capacitance must be higher than the electrode capacitance by at least an order of magnitude. Capacitance slows the kinetics (the rise and fall times) of currents. If the electrode capacitance is much less than that of the cell, then when current is passed through the electrode, the electrode voltage will change faster than the cell voltage. Thus, when current is injected and then turned off (at the end of a duty cycle), the electrode voltage will decay faster than the cell voltage. As soon as the electrode voltage asymptotes to the cell voltage, the voltage can be sampled (again) and the next amount of charge applied. Thus, the frequency of the duty cycle is limited to the speed at which the electrode voltage rises and decays while passing current. The lower the electrode capacitance the faster one can cycle.

SEVC-d has a major advantage over SEVC-c in allowing the experimenter to measure membrane potential, and, as it obviates passing current and measuring voltage at the same time, there is never a series resistance error. The main disadvantages are that the time resolution is limited and the amplifier is unstable. If it passes too much current, so that the goal voltage is over-shot, it reverses the polarity of the current in the next duty cycle. This causes it to undershoot the target voltage, so the next cycle reverses the polarity of the injected current again. This error can grow with each cycle until the amplifier oscillates out of control (“ringing”); this usually results in the destruction of the cell being recorded. The investigator wants a short duty cycle to improve temporal resolution; the amplifier has adjustable compensators that will make the electrode voltage decay faster, but, if these are set too high the amplifier will ring, so the investigator is always trying to “tune” the amplifier as close to the edge of uncontrolled oscillation as possible, in which case small changes in recording conditions can cause ringing. There are two solutions: to “back off” the amplifier settings into a safe range, or to be alert for signs that the amplifier is about to ring.

Mathematical modeling

From the point of view of control theory, the voltage clamp experiment can be described in terms of the application of a high-gain output feedback control law [13] to the neuronal membrane. [14] Mathematically, the membrane voltage can be modeled by a conductance-based model with an input given by the applied current and an output given by the membrane voltage . Hodgkin and Huxley's original conductance-based model, which represents a neuronal membrane containing sodium and potassium ion currents, as well as a leak current, is given by the system of ordinary differential equations

where is the membrane capacitance, , and are maximal conductances, , and are reversal potentials, and are ion channel voltage-dependent rate constants, and the state variables , , and are ion channel gating variables.

It is possible to rigorously show that the feedback law

drives the membrane voltage arbitrarily close to the reference voltage as the gain is increased to an arbitrarily large value. [14] This fact, which is by no means a general property of dynamical systems (a high-gain can, in general, lead to instability [15] ), is a consequence of the structure and the properties of the conductance-based model above. In particular, the dynamics of each gating variable , which are driven by , verify the strong stability property of exponential contraction. [14] [16]

Related Research Articles

Electrophysiology Study of the electrical properties of biological cells and tissues.

Electrophysiology is the branch of physiology that studies the electrical properties of biological cells and tissues. It involves measurements of voltage changes or electric current or manipulations on a wide variety of scales from single ion channel proteins to whole organs like the heart. In neuroscience, it includes measurements of the electrical activity of neurons, and, in particular, action potential activity. Recordings of large-scale electric signals from the nervous system, such as electroencephalography, may also be referred to as electrophysiological recordings. They are useful for electrodiagnosis and monitoring.

Action potential Process by which neurons communicate with each other by changes in their membrane potentials

In physiology, an action potential (AP) occurs when the membrane potential of a specific cell location rapidly rises and falls: this depolarization then causes adjacent locations to similarly depolarize. Action potentials occur in several types of animal cells, called excitable cells, which include neurons, muscle cells, endocrine cells and in some plant cells.

Hyperpolarization is a change in a cell's membrane potential that makes it more negative. It is the opposite of a depolarization. It inhibits action potentials by increasing the stimulus required to move the membrane potential to the action potential threshold.

Membrane potential Type of physical quantity

Membrane potential is the difference in electric potential between the interior and the exterior of a biological cell. That is, there is a difference in the energy required for electric charges to move from the internal to exterior cellular environments and vice versa, as long as there is no acquisition of kinetic energy or the production of radiation. The concentration gradients of the charges directly determine this energy requirement. For the exterior of the cell, typical values of membrane potential, normally given in units of millivolts and denoted as mV, range from –80 mV to –40 mV.

Threshold potential

In electrophysiology, the threshold potential is the critical level to which a membrane potential must be depolarized to initiate an action potential. In neuroscience, threshold potentials are necessary to regulate and propagate signaling in both the central nervous system (CNS) and the peripheral nervous system (PNS).

Patch clamp

The patch clamp technique is a laboratory technique in electrophysiology used to study ionic currents in individual isolated living cells, tissue sections, or patches of cell membrane. The technique is especially useful in the study of excitable cells such as neurons, cardiomyocytes, muscle fibers, and pancreatic beta cells, and can also be applied to the study of bacterial ion channels in specially prepared giant spheroplasts.

A glass electrode is a type of ion-selective electrode made of a doped glass membrane that is sensitive to a specific ion. The most common application of ion-selective glass electrodes is for the measurement of pH. The pH electrode is an example of a glass electrode that is sensitive to hydrogen ions. Glass electrodes play an important part in the instrumentation for chemical analysis and physico-chemical studies. The voltage of the glass electrode, relative to some reference value, is sensitive to changes in the activity of certain type of ions.

The sucrose gap technique is used to create a conduction block in nerve or muscle fibers. A high concentration of sucrose is applied to the extracellular space, which prevents the correct opening and closing of sodium and potassium channels, increasing resistance between two groups of cells. It was originally developed by Robert Stämpfli for recording action potentials in nerve fibers, and is particularly useful for measuring irreversible or highly variable pharmacological modifications of channel properties since untreated regions of membrane can be pulled into the node between the sucrose regions.

Potentiostat Electronic system controlling a three electrode cell

A potentiostat is the electronic hardware required to control a three electrode cell and run most electroanalytical experiments. A Bipotentiostat and polypotentiostat are potentiostats capable of controlling two working electrodes and more than two working electrodes, respectively.

Voltammetry Set of electroanalytical methods

Voltammetry is a category of electroanalytical methods used in analytical chemistry and various industrial processes. In voltammetry, information about an analyte is obtained by measuring the current as the potential is varied. The analytical data for a voltammetric experiment comes in the form of a voltammogram which plots the current produced by the analyte versus the potential of the working electrode.

Hodgkin–Huxley model Describes how neurons transmit electric signals

The Hodgkin–Huxley model, or conductance-based model, is a mathematical model that describes how action potentials in neurons are initiated and propagated. It is a set of nonlinear differential equations that approximates the electrical characteristics of excitable cells such as neurons and cardiac myocytes. It is a continuous-time dynamical system.

In neuroscience, single-unit recordings provide a method of measuring the electro-physiological responses of a single neuron using a microelectrode system. When a neuron generates an action potential, the signal propagates down the neuron as a current which flows in and out of the cell through excitable membrane regions in the soma and axon. A microelectrode is inserted into the brain, where it can record the rate of change in voltage with respect to time. These microelectrodes must be fine-tipped, high-impedance conductors; they are primarily glass micro-pipettes, metal microelectrodes made of platinum, tungsten, iridium or even iridium oxide. Microelectrodes can be carefully placed close to the cell membrane, allowing the ability to record extracellularly.

Cable theory

Classical cable theory uses mathematical models to calculate the electric current along passive neurites, particularly the dendrites that receive synaptic inputs at different sites and times. Estimates are made by modeling dendrites and axons as cylinders composed of segments with capacitances and resistances combined in parallel. The capacitance of a neuronal fiber comes about because electrostatic forces are acting through the very thin lipid bilayer. The resistance in series along the fiber is due to the axoplasm's significant resistance to movement of electric charge.

Soliton model in neuroscience

The soliton hypothesis in neuroscience is a model that claims to explain how action potentials are initiated and conducted along axons based on a thermodynamic theory of nerve pulse propagation. It proposes that the signals travel along the cell's membrane in the form of certain kinds of solitary sound pulses that can be modeled as solitons. The model is proposed as an alternative to the Hodgkin–Huxley model in which action potentials: voltage-gated ion channels in the membrane open and allow sodium ions to enter the cell. The resulting decrease in membrane potential opens nearby voltage-gated sodium channels, thus propagating the action potential. The transmembrane potential is restored by delayed opening of potassium channels. Soliton hypothesis proponents assert that energy is mainly conserved during propagation except dissipation losses; Measured temperature changes are completely inconsistent with the Hodgkin-Huxley model.

Biological neuron model Mathematical descriptions of the properties of certain cells in the nervous system

Biological neuron models, also known as a spiking neuron models, are mathematical descriptions of the properties of certain cells in the nervous system that generate sharp electrical potentials across their cell membrane, roughly one millisecond in duration, called action potentials or spikes. Since spikes are transmitted along the axon and synapses from the sending neuron to many other neurons, spiking neurons are considered to be a major information processing unit of the nervous system. Spiking neuron models can be divided into different categories: the most detailed mathematical models are biophysical neuron models that describe the membrane voltage as a function of the input current and the activation of ion channels. Mathematically simpler are integrate-and-fire models that describe the membrane voltage as a function of the input current and predict the spike times without a description of the biophysical processes that shape the time course of an action potential. Even more abstract models only predict output spikes as a function of the stimulation where the stimulation can occur through sensory input or pharmacologically. This article provides a short overview of different spiking neuron models and links, whenever possible to experimental phenomena. It includes deterministic and probabilistic models.

In neurophysiology, several mathematical models of the action potential have been developed, which fall into two basic types. The first type seeks to model the experimental data quantitatively, i.e., to reproduce the measurements of current and voltage exactly. The renowned Hodgkin–Huxley model of the axon from the Loligo squid exemplifies such models. Although qualitatively correct, the H-H model does not describe every type of excitable membrane accurately, since it considers only two ions, each with only one type of voltage-sensitive channel. However, other ions such as calcium may be important and there is a great diversity of channels for all ions. As an example, the cardiac action potential illustrates how differently shaped action potentials can be generated on membranes with voltage-sensitive calcium channels and different types of sodium/potassium channels. The second type of mathematical model is a simplification of the first type; the goal is not to reproduce the experimental data, but to understand qualitatively the role of action potentials in neural circuits. For such a purpose, detailed physiological models may be unnecessarily complicated and may obscure the "forest for the trees". The FitzHugh–Nagumo model is typical of this class, which is often studied for its entrainment behavior. Entrainment is commonly observed in nature, for example in the synchronized lighting of fireflies, which is coordinated by a burst of action potentials; entrainment can also be observed in individual neurons. Both types of models may be used to understand the behavior of small biological neural networks, such as the central pattern generators responsible for some automatic reflex actions. Such networks can generate a complex temporal pattern of action potentials that is used to coordinate muscular contractions, such as those involved in breathing or fast swimming to escape a predator.

Microelectrode arrays (MEAs) are devices that contain multiple microelectrodes through which neural signals are obtained or delivered, essentially serving as neural interfaces that connect neurons to electronic circuitry. There are two general classes of MEAs: implantable MEAs, used in vivo, and non-implantable MEAs, used in vitro.

Cellular neuroscience is a branch of neuroscience concerned with the study of neurons at a cellular level. This includes morphology and physiological properties of single neurons. Several techniques such as intracellular recording, patch-clamp, and voltage-clamp technique, pharmacology, confocal imaging, molecular biology, two photon laser scanning microscopy and Ca2+ imaging have been used to study activity at the cellular level. Cellular neuroscience examines the various types of neurons, the functions of different neurons, the influence of neurons upon each other, and how neurons work together.

Transimpedance amplifier Amplifier that converts current to voltage

In electronics, a transimpedance amplifier (TIA) is a current to voltage converter, almost exclusively implemented with one or more operational amplifiers. The TIA can be used to amplify the current output of Geiger–Müller tubes, photo multiplier tubes, accelerometers, photo detectors and other types of sensors to a usable voltage. Current to voltage converters are used with sensors that have a current response that is more linear than the voltage response. This is the case with photodiodes where it is not uncommon for the current response to have better than 1% nonlinearity over a wide range of light input. The transimpedance amplifier presents a low impedance to the photodiode and isolates it from the output voltage of the operational amplifier. In its simplest form a transimpedance amplifier has just a large valued feedback resistor, Rf. The gain of the amplifer is set by this resistor and because the amplifier is in an inverting configuration, has a value of -Rf. There are several different configurations of transimpedance amplifiers, each suited to a particular application. The one factor they all have in common is the requirement to convert the low-level current of a sensor to a voltage. The gain, bandwidth, as well as current and voltage offsets change with different types of sensors, requiring different configurations of transimpedance amplifiers.

Supercapacitor Electrochemical capacitor that bridges the gap between electrolytic capacitors and rechargeable batteries

A supercapacitor (SC), also called an ultracapacitor, is a high-capacity capacitor with a capacitance value much higher than other capacitors, but with lower voltage limits, that bridges the gap between electrolytic capacitors and rechargeable batteries. It typically stores 10 to 100 times more energy per unit volume or mass than electrolytic capacitors, can accept and deliver charge much faster than batteries, and tolerates many more charge and discharge cycles than rechargeable batteries.

References

  1. Nowotny T, Levi R (2014). Jaeger D, Jung R (eds.). Encyclopedia of Computational Neuroscience. Springer New York. pp. 1–5. doi:10.1007/978-1-4614-7320-6_137-2. ISBN   9781461473206.
  2. 1 2 Hernández-Ochoa EO, Schneider MF (April 2012). "Voltage clamp methods for the study of membrane currents and SR Ca(2+) release in adult skeletal muscle fibres". Progress in Biophysics and Molecular Biology. 108 (3): 98–118. doi:10.1016/j.pbiomolbio.2012.01.001. PMC   3321118 . PMID   22306655.
  3. Kandel ER, Schwartz JH, Jessell TM, eds. (2000). Principles of Neural Science (4th ed.). New York: McGraw-Hill. pp.  152–3. ISBN   978-0-8385-7701-1.
  4. Bear MF, Connors BW, Paradiso MA, eds. (2006) [1996]. Neuroscience: Exploring the Brain (3rd ed.). Philadelphia, Baltimore: Lippincott Williams & Wilkins. p. 84. ISBN   978-0-7817-6003-4. LCC   QP355.2.B42.
  5. Moore JW, Hines ML (1994). "A Brief history of Computational Neuroscience". Simulations with NEURON. Duke University.
  6. 1 2 Andrew Huxley, 1996, "Kenneth Sterward Cole 1900 – 1984, A biographical Memoir" National Academy of Sciences. (Washington D.C.)
  7. 1 2 Huxley A (November 2002). "From overshoot to voltage clamp". Trends in Neurosciences. 25 (11): 553–8. doi:10.1016/S0166-2236(02)02280-4. PMID   12392929. S2CID   7453707.
  8. Vandenberg, J. I. and S. G. Waxman (2012). "Hodgkin and Huxley and the basis for electrical signalling: a remarkable legacy still going strong." J. Physiol. (Oxford, U. K.) 590(11): 2569–2570.
  9. Guan B, Chen X, Zhang H (2013). "Two-electrode voltage clamp". Methods in Molecular Biology. 998: 79–89. doi:10.1007/978-1-62703-351-0_6. ISBN   978-1-62703-350-3. PMID   23529422.
  10. 1 2 3 Polder HR, Swandulla D (August 2001). "The use of control theory for the design of voltage clamp systems: a simple and standardized procedure for evaluating system parameters". Journal of Neuroscience Methods. 109 (2): 97–109. doi:10.1016/S0165-0270(01)00385-5. PMID   11513944. S2CID   44840152.
  11. DiFranco M, Herrera A, Vergara JL (January 2011). "Chloride currents from the transverse tubular system in adult mammalian skeletal muscle fibers". The Journal of General Physiology. 137 (1): 21–41. doi:10.1085/jgp.201010496. PMC   3010054 . PMID   21149546.
  12. 1 2 Van Rijen HV, Wilders R, Van Ginneken AC, Jongsma HJ (June 1998). "Quantitative analysis of dual whole-cell voltage-clamp determination of gap junctional conductance". Pflügers Archiv. 436 (1): 141–51. doi:10.1007/s004240050615. PMID   9560458. S2CID   23697774.
  13. Marino R (December 1985). "High-gain feedback in non-linear control systems". International Journal of Control. 42 (6): 1369–1385. doi:10.1080/00207178508933431.
  14. 1 2 3 Burghi TB, Schoukens M, Sepulchre R (2021). "Feedback identification of conductance-based models". Automatica. 123: 109297.
  15. "Control Systems/Gain - Wikibooks, open books for an open world". en.wikibooks.org. Retrieved 2021-04-06.
  16. Lohmiller W, Slotine JJ (1998). "On Contraction Analysis for Non-linear Systems". Automatica. 34 (6): 683–696.

Further reading