Air ioniser

Last updated

This photo shows the sterilisation effects of negative air ionization on a chamber aerosolised with Salmonella enteritidis. The left sample is untreated; the right, treated. Sterilization effects of negative air ionization.jpg
This photo shows the sterilisation effects of negative air ionization on a chamber aerosolised with Salmonella enteritidis . The left sample is untreated; the right, treated.

An air ioniser (or negative ion generator or Chizhevsky's chandelier) is a device that uses high voltage to ionise (electrically charge) air molecules. Negative ions, or anions, are particles with one or more extra electrons, conferring a net negative charge to the particle. Cations are positive ions missing one or more electrons, resulting in a net positive charge. Some commercial air purifiers are designed to generate negative ions. Another type of air ioniser is the electrostatic discharge (ESD) ioniser (balanced ion generator) used to neutralise static charge.

Contents

History

In 1918 Alexander Chizhevsky created the first air ioniser for ion therapy. [1] It was originally used for animal health in agriculture. [2] This discovery ignited Cecil Alfred "Coppy" Laws' interest in the phenomenon of air ionisation. Laws has been credited with being the inventor of the domestic air ioniser. [1]

Ionic air purifiers

Air ioniser and purifier with its dust collection plates removed Air ionizer and collection plate.jpg
Air ioniser and purifier with its dust collection plates removed

Air ionisers are used in air purifiers to remove particles from air. [3] Airborne particles become charged as they attract charged ions from the ioniser by electrostatic attraction. The particles in turn are then attracted to any nearby earthed (grounded) conductors, either deliberate plates within an air cleaner, or simply the nearest walls and ceilings. The frequency of nosocomial infections in British hospitals prompted the National Health Service (NHS) to research the effectiveness of anions for air purification, finding that repeated airborne acinetobacter infections in a ward were eliminated after the installation of a negative air ioniser — a promising result, although more evidence is necessary to determine if these results can be repeated. [4] Positive and negative ions produced by air conditioning systems have also been found by a manufacturer to inactivate viruses including influenza.

A 2018 review found that negative air ions are highly effective in removing particulate matter from air. [5]

The SARS epidemic fuelled the desire for personal ionisers in East Asia, including Japan (where many products have been specialised to contain negative ion generators, including toothbrushes, refrigerators, air conditioners, air cleaners, and washing machines). There are no specific standards for these devices.

There are two types of ionic air purifiers, the fanless and fan base ionizers. The fan base ionizer uses its fan to circulate air around the room rapidly, but it is noisier and consumes more energy, while the fanless types distribute air slowly, taking a longer time to purify air, but are noiseless and more energy efficient.

California regulation of ozone produced by air cleaners and ionizers

The California Air Resources Board has a page listing air cleaners (many with ionizers) meeting their indoor ozone limit of 0.050 parts per million. [6] From that article:

Since 2010, all portable indoor air cleaning devices sold to people or businesses in California are required to be certified by CARB. As of October 2020, electronic in-duct air cleaning devices are also subject to the regulation. To be certified, all air cleaners must be tested for electrical safety. Electronic air cleaners must also be tested for ozone emissions and meet an ozone emission concentration limit of 0.050 parts per million (50 ppb).

Ions versus ozone

Ionisers are distinct from ozone generators, although both devices operate in a similar way. Ionisers use electrostatically charged plates to produce positively or negatively charged air ions (for instance N2+ or O2 ; these "primary" ions then immediately cluster with other air molecules such as H2O) that particulate matter sticks to. [7] Ionisers tend to produce negative ions since these are supposed to have beneficial health effects. Even the best ionisers will also produce a small amount of ozone—triatomic oxygen, O3—which is unwanted. Ozone generators are optimised to attract an extra oxygen ion to an O2 molecule, using either a corona discharge tube or UV light. [8]

At concentrations that do not exceed public health standards, ozone has been found to have little potential to remove indoor air contaminants. [9] At high concentrations ozone can be toxic to air-borne bacteria, and may destroy or kill these sometimes infectious organisms. However, the required concentrations are sufficiently toxic to humans and animals that the U.S. FDA declares that ozone has no place in medical treatment [10] and has taken action against businesses that offer ozone generators or ozone therapy to consumers. [11] Ozone is a highly toxic and extremely reactive gas. [12] A higher daily average than 0.1 ppm (100 ppb, 0.2 mg/m3) is not recommended and can damage the lungs and olfactory bulb cells directly. [13]

Health effects

A 2013 comprehensive review of 80 years of research into air ions and respiratory function outcomes found that there was no clear support for any beneficial role in respiratory function, nor evidence for significant detrimental effect. In conclusion, "exposure to negative or positive air ions does not appear to play an appreciable role in respiratory function." [14]

There is weak evidence that negative air ionization is associated with lower depression scores, particularly at the highest exposure level. No consistent influence of positive or negative air ionization on anxiety, mood, relaxation, sleep, and personal comfort measures was observed. [15]

Adverse health effects of ozone byproduct

Studies have been carried out on negative ion generators. One study shows that the ozone generated can exceed guidelines in small, non ventilated areas. [16] Another study showed that ozone can react with other constituents, namely cleaning agents to increase pollutants such as formaldehyde; this study's objective was testing for health risks associated with indoor use of cleaning products and air fresheners as opposed to adverse health effects of air ionisers. [17]

Consumer Reports court case

Consumer Reports , a non-profit U.S.-based product-testing magazine, reported in October 2003 that air ionisers do not perform to high enough standards compared to conventional HEPA filters. The exception was a combination unit that used a fan to move air while ionizing it. In response to this report, The Sharper Image, a manufacturer of air ionisers (among other products), sued Consumer's Union (the publishers of Consumer Reports) for product defamation. Consumer Reports gave the Ionic Breeze and other popular units a "fail" because they have a low clean air delivery rate (CADR). CADR measures the amount of filtered air circulated during a short period of time, and was originally designed to rate media-based air cleaners. The Sharper Image claimed that this test was a poor way to rate the Ionic Breeze, since it does not take into account other features, such as 24-hour-a-day continuous cleaning, ease of maintenance, and silent operation.

The United States District Court for the Northern District of California dismissed the case, reasoning that the Sharper Image had failed to demonstrate that it could prove any of the statements made by Consumer Reports were false. The court's final ruling in May 2005 ordered the Sharper Image to pay US$525,000 for Consumer Union's legal expenses. [18]

Electrostatic neutraliser in electronics

Air ionisers are often used in places where work is done involving static-electricity-sensitive electronic components (like in microelectronics cleanrooms), to eliminate the build-up of static charges on non-conductors. As those elements are very sensitive to electricity, they cannot be grounded because the discharge will destroy them as well. Usually, the work is done over a special dissipative table mat, which allows a very slow discharge, and under the air gush of an ioniser. The ionization falls off very sharply with distance (even in ducting), so air ionization is rarely used for this purpose, and only for items immediately adjacent to the actual ionizer.

See also

Related Research Articles

<span class="mw-page-title-main">Fusor</span> An apparatus to create nuclear fusion

A fusor is a device that uses an electric field to heat ions to a temperature in which they undergo nuclear fusion. The machine induces a potential difference between two metal cages, inside a vacuum. Positive ions fall down this voltage drop, building up speed. If they collide in the center, they can fuse. This is one kind of an inertial electrostatic confinement device – a branch of fusion research.

<span class="mw-page-title-main">Laser printing</span> Electrostatic digital printing process

Laser printing is an electrostatic digital printing process. It produces high-quality text and graphics by repeatedly passing a laser beam back and forth over a negatively charged cylinder called a "drum" to define a differentially charged image. The drum then selectively collects electrically charged powdered ink (toner), and transfers the image to paper, which is then heated to permanently fuse the text, imagery, or both, to the paper. As with digital photocopiers, laser printers employ a xerographic printing process. Laser printing differs from traditional xerography as implemented in analog photocopiers in that in the latter, the image is formed by reflecting light off an existing document onto the exposed drum.

<span class="mw-page-title-main">Van de Graaff generator</span> Electrostatic particle accelerator operating on the triboelectric effect

A Van de Graaff generator is an electrostatic generator which uses a moving belt to accumulate electric charge on a hollow metal globe on the top of an insulated column, creating very high electric potentials. It produces very high voltage direct current (DC) electricity at low current levels. It was invented by American physicist Robert J. Van de Graaff in 1929. The potential difference achieved by modern Van de Graaff generators can be as much as 5 megavolts. A tabletop version can produce on the order of 100 kV and can store enough energy to produce visible electric sparks. Small Van de Graaff machines are produced for entertainment, and for physics education to teach electrostatics; larger ones are displayed in some science museums.

<span class="mw-page-title-main">Electrostatic discharge</span> Sudden flow of electric current between two electrically charged objects by contact

Electrostatic discharge (ESD) is a sudden and momentary flow of electric current between two differently-charged objects when brought close together or when the dielectric between them breaks down, often creating a visible spark associated with the static electricity between the objects.

<span class="mw-page-title-main">Static electricity</span> Imbalance of electric charges within or on the surface of a material

Static electricity is an imbalance of electric charges within or on the surface of a material. The charge remains until it can move away by an electric current or electrical discharge. The word "static" is used to differentiate it from current electricity, where an electric charge flows through an electrical conductor.

<span class="mw-page-title-main">Corona discharge</span> Ionization of air around a high-voltage conductor

A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air. A corona discharge occurs at locations where the strength of the electric field around a conductor exceeds the dielectric strength of the air. It is often seen as a bluish glow in the air adjacent to pointed metal conductors carrying high voltages, and emits light by the same mechanism as a gas discharge lamp. Corona discharges can also happen in weather, such as thunderstorms, where objects like ship masts or airplane wings have a charge significantly different from the air around them.

<span class="mw-page-title-main">Inertial electrostatic confinement</span> Fusion power research concept

Inertial electrostatic confinement, or IEC, is a class of fusion power devices that use electric fields to confine the plasma rather than the more common approach using magnetic fields found in magnetic confinement fusion (MCF) designs. Most IEC devices directly accelerate their fuel to fusion conditions, thereby avoiding energy losses seen during the longer heating stages of MCF devices. In theory, this makes them more suitable for using alternative aneutronic fusion fuels, which offer a number of major practical benefits and makes IEC devices one of the more widely studied approaches to fusion.

<span class="mw-page-title-main">HEPA</span> Efficiency standard of air filters

HEPA filter, also known as high-efficiency particulate absorbing filter and high-efficiency particulate arrestance filter, is an efficiency standard of air filters.

<span class="mw-page-title-main">Electrical breakdown</span> Conduction of electricity through an insulator under sufficiently high voltage

In electronics, electrical breakdown or dielectric breakdown is a process that occurs when an electrically insulating material, subjected to a high enough voltage, suddenly becomes a conductor and current flows through it. All insulating materials undergo breakdown when the electric field caused by an applied voltage exceeds the material's dielectric strength. The voltage at which a given insulating object becomes conductive is called its breakdown voltage and, in addition to its dielectric strength, depends on its size and shape, and the location on the object at which the voltage is applied. Under sufficient voltage, electrical breakdown can occur within solids, liquids, or gases. However, the specific breakdown mechanisms are different for each kind of dielectric medium.

<span class="mw-page-title-main">Air purifier</span> Device that removes contaminants from the air in a room

An air purifier or air cleaner is a device which removes contaminants from the air in a room to improve indoor air quality. These devices are commonly marketed as being beneficial to allergy sufferers and asthmatics, and at reducing or eliminating second-hand tobacco smoke.

An ion-propelled aircraft or ionocraft is an aircraft that uses electrohydrodynamics (EHD) to provide lift or thrust in the air without requiring combustion or moving parts. Current designs do not produce sufficient thrust for manned flight or useful loads.

<span class="mw-page-title-main">Electrohydrodynamics</span> Study of electrically conducting fluids in the presence of electric fields

Electrohydrodynamics (EHD), also known as electro-fluid-dynamics (EFD) or electrokinetics, is the study of the dynamics of electrically charged fluids. It is the study of the motions of ionized particles or molecules and their interactions with electric fields and the surrounding fluid. The term may be considered to be synonymous with the rather elaborate electrostrictive hydrodynamics. ESHD covers the following types of particle and fluid transport mechanisms: electrophoresis, electrokinesis, dielectrophoresis, electro-osmosis, and electrorotation. In general, the phenomena relate to the direct conversion of electrical energy into kinetic energy, and vice versa.

<span class="mw-page-title-main">Electrostatic precipitator</span> Filtration device

An electrostatic precipitator (ESP) is a filterless device that removes fine particles, such as dust and smoke, from a flowing gas using the force of an induced electrostatic charge minimally impeding the flow of gases through the unit.

<span class="mw-page-title-main">Ion wind</span> Charged-particle flow due to high electrostatic potential

Ion wind, ionic wind, corona wind or electric wind is the airflow of charged particles induced by electrostatic forces linked to corona discharge arising at the tips of some sharp conductors subjected to high voltage relative to ground. Ion wind is an electrohydrodynamic phenomenon. Ion wind generators can also be considered electrohydrodynamic thrusters.

<span class="mw-page-title-main">Cockcroft–Walton generator</span> Electric circuit that generates high DC voltage from low-voltage AC or pulsing DC input

The Cockcroft–Walton (CW) generator, or multiplier, is an electric circuit that generates a high DC voltage from a low-voltage AC or pulsing DC input. It was named after the British and Irish physicists John Douglas Cockcroft and Ernest Thomas Sinton Walton, who in 1932 used this circuit design to power their particle accelerator, performing the first artificial nuclear disintegration in history. They used this voltage multiplier cascade for most of their research, which in 1951 won them the Nobel Prize in Physics for "Transmutation of atomic nuclei by artificially accelerated atomic particles".

<span class="mw-page-title-main">Dust collector</span>

A dust collector is a system used to enhance the quality of air released from industrial and commercial processes by collecting dust and other impurities from air or gas. Designed to handle high-volume dust loads, a dust collector system consists of a blower, dust filter, a filter-cleaning system, and a dust receptacle or dust removal system. It is distinguished from air purifiers, which use disposable filters to remove dust.

Neutral-beam injection (NBI) is one method used to heat plasma inside a fusion device consisting in a beam of high-energy neutral particles that can enter the magnetic confinement field. When these neutral particles are ionized by collision with the plasma particles, they are kept in the plasma by the confining magnetic field and can transfer most of their energy by further collisions with the plasma. By tangential injection in the torus, neutral beams also provide momentum to the plasma and current drive, one essential feature for long pulses of burning plasmas. Neutral-beam injection is a flexible and reliable technique, which has been the main heating system on a large variety of fusion devices. To date, all NBI systems were based on positive precursor ion beams. In the 1990s there has been impressive progress in negative ion sources and accelerators with the construction of multi-megawatt negative-ion-based NBI systems at LHD (H0, 180 keV) and JT-60U (D0, 500 keV). The NBI designed for ITER is a substantial challenge (D0, 1 MeV, 40 A) and a prototype is being constructed to optimize its performance in view of the ITER future operations. Other ways to heat plasma for nuclear fusion include RF heating, electron cyclotron resonance heating (ECRH), ion cyclotron resonance heating (ICRH), and lower hybrid resonance heating (LH).

<span class="mw-page-title-main">Ion</span> Particle, atom or molecule with a net electrical charge

An ion is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convention. The net charge of an ion is not zero because its total number of electrons is unequal to its total number of protons.

<span class="mw-page-title-main">Clean air delivery rate</span> Filtration efficacy measurement

The clean air delivery rate (CADR) is a figure of merit that is the cubic feet per minute (CFM) of air that has had all the particles of a given size distribution removed. For air filters that have air flowing through them, it is the fraction of particles that have been removed from the air, multiplied by the air flow rate through the device. More precisely, it is the CFM of air in a 1,008-cubic-foot (28.5 m3) room that has had all the particles of a given size distribution removed from the air, over and above the rate at which the particles are naturally falling out of the air. Different filters have different abilities to remove different particle distributions, so three CADR's for a given device are typically measured: smoke, pollen, and dust. By combining the amount of airflow and particle removal efficiency, consumers are less likely to be misled by a high efficiency filter that is filtering a small amount of air, or by a high volume of air that is not being filtered very well.

GPS Air, formerly Global Plasma Solutions, is an indoor air quality company based in the United States that provides air conditioning and other air quality technologies for commercial and industrial buildings with a focus on using "needlepoint bi-polar cold plasma". The company produced room air quality products designed for schools, among other indoor locations, and after the outbreak of the COVID-19 pandemic thousands of schools purchased their products for preventing viral outbreaks.

References

  1. 1 2 Pat Williams. "Obituary of Coppy Laws", Thr Independent, London, England, 4 June 2002
  2. Churilov, Leonid (2017). "Master and Woland: In 120th Birthday Anniversary of Aleksandr Leonidovich Chizhevsky". Russian Biomedical Research. 2 (3): 23.
  3. Shiue, Angus (2011). "Particles Removal by Negative ionic Air Purifier in Cleanroom" (PDF). Aerosol and Air Quality Research. 11 (2): 179–186. doi: 10.4209/aaqr.2010.06.0048 .
  4. McDowell, Natasha (3 January 2003). "Air ionisers wipe out hospital infections". The New Scientist . No. Daily news. Retrieved 24 August 2016.
  5. Jiang SY, Ma A, Ramachandran S (2018). "Negative Air Ions and Their Effects on Human Health and Air Quality Improvement". International Journal of Molecular Sciences . 19 (10): E2966. doi: 10.3390/ijms19102966 . PMC   6213340 . PMID   30274196.
  6. "List of CARB-Certified Air Cleaning Devices" . Retrieved 2022-02-11.
  7. Aplin, K. L. (2008-06-01). "Composition and Measurement of Charged Atmospheric Clusters". Space Science Reviews. 137 (1): 213–224. Bibcode:2008SSRv..137..213A. doi:10.1007/s11214-008-9397-1. ISSN   1572-9672. S2CID   53334911.
  8. Thiemens, Mark H.; Jackson, Teresa (1987-06-01). "Production of isotopically heavy ozone by ultraviolet light photolysis of O2". Geophysical Research Letters. 14 (6): 624–627. Bibcode:1987GeoRL..14..624T. doi: 10.1029/GL014i006p00624 . ISSN   1944-8007.
  9. Woolston, Chris (21 April 2008). "Ionic purifiers' dirty secret". Los Angeles Times . No. The Healthy Skeptic. Retrieved 24 August 2016.
  10. "CFR – Code of Federal Regulations Title 21". www.accessdata.fda.gov. Retrieved 2017-04-26.
  11. Kurtzweil P (1999). "Ozone generators generate prison terms for couple". FDA Consum . 33 (6): 36–7. PMID   10628316.
  12. "Ozone: Good Up High, Bad Nearby". Environmental Protection Agency (EPA) Website. Retrieved 2006-08-30.
  13. "Occupational Health Guideline for Ozone" (PDF). Centers for Disease Control and Prevention .
  14. Alexander, D. D.; Bailey, W. H.; Perez, V.; Mitchell, M. E.; Su, S. (2013). "Air ions and respiratory function outcomes: a comprehensive review". Journal of Negative Results in Biomedicine. 12: 14. doi: 10.1186/1477-5751-12-14 . PMC   3848581 . PMID   24016271.
  15. Perez, V; Alexander, DD; Bailey, WH (15 January 2013). "Air ions and mood outcomes: a review and meta-analysis". BMC Psychiatry. 13: 29. doi: 10.1186/1471-244X-13-29 . PMC   3598548 . PMID   23320516.
  16. "Quantification of Ozone Levels in Indoor Environments Generated by Ionization and Ozonolysis Air Purifiers" (PDF). Air & Waste Manage. Assoc. 56:601–610. May 2006.
  17. "Indoor Air Chemistry: Cleaning Agents, Ozone and Toxic Air Contaminants" (PDF). April 2006.
  18. "Sharper Image pays $525,000 to end lawsuit against CU". Consumer Reports. 2006-08-06. Archived from the original on 2007-10-17.

Further reading