Capacity credit

Last updated

Capacity credit (CC, also capacity value [1] or de-rating factor [2] ) is the fraction of the installed capacity of a power plant which can be relied upon at a given time (typically during system stress), [3] frequently expressed as a percentage of the nameplate capacity. A conventional (dispatchable) power plant can typically provide the electricity at full power as long as it has a sufficient amount of fuel and is operational, [1] therefore the capacity credit of such a plant is close to 100%; it is exactly 100% for some definitions of the capacity credit (see below). [4] [ better source needed ] The output of a variable renewable energy (VRE) plant depends on the state of an uncontrolled natural resource (usually the sun or wind), therefore a mechanically and electrically sound VRE plant might not be able to generate at the rated capacity (neither at the nameplate, nor at the capacity factor level) when needed, [1] so its CC is much lower than 100%. The capacity credit is useful for a rough estimate of the firm power a system with weather-dependent generation can reliably provide. [5] For example, with a low, but realistic (cf. Ensslin et al. [6] ) wind power capacity credit of 5%, 20 gigawatts (GW) worth of wind power needs to be added to the system in order to permanently retire a 1 GW fossil fuel plant while keeping the electrical grid reliability at the same level.

Contents

Definitions

There are a few similar definitions of the capacity credit: [1] [7]

Values

The capacity credit can be much lower than the capacity factor (CF): in a not very probable scenario, if the riskiest time for the power system is after sunset, the capacity credit for solar power without coupled energy storage is zero regardless of its CF [3] (under this scenario all existing conventional power plants would have to be retained after the solar installation is added). More generally, the CC is low when the times of the day (or seasons) for the peak load do not correlate well with times of high energy production. [14] Ensslin et al. [6] report wind CC values ranging from 40% down to 5%, with values dropping off with increased wind power penetration.

For very low penetrations (few percent), when the chance of the system actually being forced to rely on the VRE at peak times is negligible, the CC of a VRE plant is close to its capacity factor. [6] For high penetrations, due to the fact that the weather tends to affect all plants of similar type at the same time and in the same way - and the chance of a system stress during low wind condition increases, [15] the capacity credit of a VRE plant decreases. Greater geographical diversity of the VRE installations improves the capacity credit value, assuming a grid that can carry all necessary load. [6] Increasing the penetration of one VRE resource also can result in increasing the CC for another one, e.g., in California, increase in solar capacity, with a low incremental CC, expected to be 8% in 2023 and dropping to 6% by 2026, [16] helps shifting the peak demand from other sources later into the evening, [17] when the wind is stronger, therefore the CC of the wind power is expected to increase from 14% to 22% within the same period. [16] A 2020 study of ELCC by California utilities recommends even more pessimistic values for photovoltaics: by 2030 the ELCC of solar will become "nearly zero". [18] The California Public Utilities Commission orders of 2021 and 2023 intend to add by 2035 additional renewable generation capacity with NQC of 15.5 GW and nameplate capacity of 85 GW, [19] implying planned NQC for renewables (a combination of solar and wind), combined with geothermal, batteries, long-term storage, and demand response to be 15.5/85 = 18%.

In some areas peak demand is driven by air conditioning and occurs on summer afternoons and evenings, [14] while the wind is strongest at night, with offshore wind strongest in the winter. [20] This results in a relatively low CC for such potential wind power locations: for example in Texas a predicted average for onshore wind is 13% and for offshore wind is 7%. [21]

In Great Britain, the solar contribution to the system adequacy is small and is primarily due to scenarios when the use of solar allows to keep the battery storage fully charged until later in the evening. [22] The National Grid ESO in 2019 suggested planning for the following EFC-based de-rating: [23]

Indicative de-rating factors in Great Britain
YearOnshore windOffshore wind Solar PV
2020/20219.0%14.7%1.2%
2022/20238.4%12.9%1.2%
2023/20248.2%12.1%1.2%

Related Research Articles

Distributed generation, also distributed energy, on-site generation (OSG), or district/decentralized energy, is electrical generation and storage performed by a variety of small, grid-connected or distribution system-connected devices referred to as distributed energy resources (DER).

<span class="mw-page-title-main">Electricity sector in India</span> Power generation and distribution

India is the third largest producer of electricity in the world. During the fiscal year (FY) 2021–22, the total electricity generation in the country was 1,719 TWh, of which 1,484 TWh was generated by utilities.

<span class="mw-page-title-main">Capacity factor</span> Electrical production measure

The net capacity factor is the unitless ratio of actual electrical energy output over a given period of time to the theoretical maximum electrical energy output over that period. The theoretical maximum energy output of a given installation is defined as that due to its continuous operation at full nameplate capacity over the relevant period. The capacity factor can be calculated for any electricity producing installation, such as a fuel consuming power plant or one using renewable energy, such as wind or the sun. The average capacity factor can also be defined for any class of such installations, and can be used to compare different types of electricity production.

<span class="mw-page-title-main">Texas Interconnection</span> Power grid providing power to most of Texas

The Texas Interconnection is an alternating current (AC) power grid – a wide area synchronous grid – that covers most of the state of Texas. The grid is managed by the Electric Reliability Council of Texas (ERCOT).

A virtual power plant (VPP) is a cloud-based distributed power plant that aggregates the capacities of heterogeneous distributed energy resources (DER) for the purposes of enhancing power generation, trading or selling power on the electricity market, and demand side options for load reduction.

<span class="mw-page-title-main">Hybrid power</span> Combinations between different technologies to generate electric power

Hybrid power are combinations between different technologies to produce power.

A load-following power plant, regarded as producing mid-merit or mid-priced electricity, is a power plant that adjusts its power output as demand for electricity fluctuates throughout the day. Load-following plants are typically in between base load and peaking power plants in efficiency, speed of start-up and shut-down, construction cost, cost of electricity and capacity factor.

<span class="mw-page-title-main">Solar power in Spain</span>

Spain is one of the first countries to deploy large-scale solar photovoltaics, and is the world leader in concentrated solar power (CSP) production.

<span class="mw-page-title-main">Solar power in Germany</span>

Solar power accounted for an estimated 8.2 per cent of electricity in Germany in 2019, which was almost exclusively from photovoltaics (PV). About 1.5 million photovoltaic systems were installed around the country in 2014, ranging from small rooftop systems, to medium commercial and large utility-scale solar parks. Germany's largest solar farms are located in Meuro, Neuhardenberg, and Templin with capacities over 100 MW.

<span class="mw-page-title-main">Solar power</span> Conversion of energy from sunlight into electricity

Solar power is the conversion of energy from sunlight into electricity, either directly using photovoltaics (PV) or indirectly using concentrated solar power. Photovoltaic cells convert light into an electric current using the photovoltaic effect. Concentrated solar power systems use lenses or mirrors and solar tracking systems to focus a large area of sunlight to a hot spot, often to drive a steam turbine.

<span class="mw-page-title-main">Electricity sector in China</span>

China's electric power industry is the world's largest electricity producer, passing the United States in 2011 after rapid growth since the early 1990s. In 2021, China produced 8.5 petawatt-hour (Pwh) of electricity, approximately 30% of the world's electricity. In 2019, China had produced 7.3 petawatt-hour (PWh) of electricity, more than the next three countries combined.

<span class="mw-page-title-main">Solar power in California</span>

Solar power has been growing rapidly in the U.S. state of California because of high insolation, community support, declining solar costs, and a renewable portfolio standard which requires that 60% of California's electricity come from renewable resources by 2030, with 100% by 2045. Much of this is expected to come from solar power via photovoltaic facilities or concentrated solar power facilities.

<span class="mw-page-title-main">Renewable energy in India</span>

India is world's 3rd largest consumer of electricity and world's 3rd largest renewable energy producer with 40% of energy capacity installed in the year 2022 coming from renewable sources. Ernst & Young's (EY) 2021 Renewable Energy Country Attractiveness Index (RECAI) ranked India 3rd behind USA and China. In FY2023-24, India is planning to issue 50 GW tenders for wind, solar and hybrid projects. India has committed for a goal of 500 GW renewable energy capacity by 2030.In line with this commitment, India's installed renewable energy capacity has been experiencing a steady upward trend. From 94.4 GW in 2021, the capacity has gone up to 119.1 GW in 2023 as of Q4.

Inertial response is a property of large synchronous generators, which contain large synchronous rotating masses, and which acts to overcome any immediate imbalance between power supply and demand for electric power systems, typically the electrical grid. Due to the ever existing power imbalance between mechanical power supply and electric power demand the rotational frequency of the rotating masses in all synchronous generators in the grid either speed up and thus absorb the extra power in case of an excess power supply, or slow down and provide additional power in case of an excess power demand. This response in case of a synchronous generator is built-in into the design and happens without any external intervention or coordination, providing the automatic generation control and the grid operator with valuable time to rebalance the system The grid frequency is the combined result of the detailed motions of all individual synchronous rotors in the grid, which are modeled by a general equation of motion called the swing equation.

<span class="mw-page-title-main">Variable renewable energy</span> Class of renewable energy sources

Variable renewable energy (VRE) or intermittent renewable energy sources (IRES) are renewable energy sources that are not dispatchable due to their fluctuating nature, such as wind power and solar power, as opposed to controllable renewable energy sources, such as dammed hydroelectricity or biomass, or relatively constant sources, such as geothermal power.

<span class="mw-page-title-main">Photovoltaic power station</span> Large-scale photovoltaic system

A photovoltaic power station, also known as a solar park, solar farm, or solar power plant, is a large-scale grid-connected photovoltaic power system designed for the supply of merchant power. They are different from most building-mounted and other decentralized solar power because they supply power at the utility level, rather than to a local user or users. Utility-scale solar is sometimes used to describe this type of project.

<span class="mw-page-title-main">Energy in California</span> Overview of the use of energy in California, U.S.

Energy in California is a major area of the economy of California. California is the state with the largest population and the largest economy in the United States. It is second in energy consumption after Texas. As of 2018, per capita consumption was the fourth-lowest in the United States partially because of the mild climate and energy efficiency programs.

Energy forecasting includes forecasting demand (load) and price of electricity, fossil fuels and renewable energy sources. Forecasting can be both expected price value and probabilistic forecasting.

<span class="mw-page-title-main">Duck curve</span> Graph showing the timing imbalance between peak demand and renewable electricity production

The duck curve is a graph of power production over the course of a day that shows the timing imbalance between peak demand and solar power generation. Used in utility-scale electricity generation, the term was coined in 2012 by the California Independent System Operator.

Resource adequacy in the field of electric power is the ability of the electric grid to satisfy the end-user power demand at any time. RA is a component of the electric system reliability. For example, sufficient unused generation capacity shall be available to the electrical grid at any time to accommodate equipment failures and drops in variable renewable energy sources. The adequacy standard should satisfy the chosen reliability index, typically the loss of load expectation (LOLE) of 1 day in 10 years.

References

  1. 1 2 3 4 Dent, Keane & Bialek 2010.
  2. "Resource adequacy in the 2030s".
  3. 1 2 Jorgenson et al. 2021, p. 1.
  4. Brand, Stambouli & Zejli 2012.
  5. Jorgenson et al. 2021, pp. 1–2.
  6. 1 2 3 4 Ensslin et al. 2008, p. 3.
  7. 1 2 3 4 Söder 2015, p. 2209.
  8. CPUC 2020, p. 12.
  9. CPUC 2020, pp. 13–14.
  10. CPUC 2020, pp. 15–16.
  11. CPUC 2020, p. 7.
  12. Garver 1966.
  13. National Grid 2019, p. 4.
  14. 1 2 Jorgenson et al. 2021, p. 6.
  15. National Grid 2019, p. 16.
  16. 1 2 CPUC 2021, p. 9.
  17. CPUC 2021, p. 10.
  18. Carden, Kevin; Krasny Dombrowsky, Alex; Winkler, Chase (2020). "2020 Joint IOU ELCC Study, Report 1" . Retrieved 10 September 2022.
  19. CPUC (February 23, 2023). "CPUC Augments Historic Clean Energy Procurement Goals To Ensure Electric Reliability". cpuc.ca.gov. California Public Utilities Commission . Retrieved 12 April 2023.
  20. Jorgenson et al. 2021, p. 7.
  21. Jorgenson et al. 2021, p. 21.
  22. National Grid 2019, p. 6.
  23. National Grid 2019, p. 3.

Sources