ITU-R 468 (originally defined in CCIR recommendation 468-4, therefore formerly also known as CCIR weighting; sometimes referred to as CCIR-1k) is a standard relating to noise measurement, widely used when measuring noise in audio systems. The standard, [1] now referred to as ITU-R BS.468-4, defines a weighting filter curve, together with a quasi-peak rectifier having special characteristics as defined by specified tone-burst tests. It is currently maintained by the International Telecommunication Union who took it over from the CCIR.

Contents

It is used especially in the UK, Europe, and former countries of the British Empire such as Australia and South Africa.[ citation needed ] It is less well known in the USA where A-weighting has always been used. [2]

M-weighting is a closely related filter, an offset version of the same curve, without the quasi-peak detector.

Explanation

The A-weighting curve was based on the 40 phon equal-loudness contour derived initially by Fletcher and Munson (1933). Originally incorporated into an ANSI standard for sound level meters, A-weighting was intended for measurement of the audibility of sounds by themselves. It was never specifically intended for the measurement of the more random (near-white or pink) noise in electronic equipment, though has been used for this purpose by most microphone manufacturers since the 1970s. The human ear responds quite differently to clicks and bursts of random noise, and it is this difference that gave rise to the CCIR-468 weighting curve (now supported as an ITU standard), which together with quasi-peak measurement (rather than the rms measurement used with A-weighting) became widely used by broadcasters throughout Britain, Europe, and former British Commonwealth countries, where engineers were heavily influenced by BBC test methods. Telephone companies worldwide have also used methods similar to ITU-R 468 weighting with quasi-peak measurement to describe objectionable interference induced in one telephone circuit by switching transients in another.

History

Original research

Developments in the 1960s, in particular the spread of FM broadcasting and the development of the compact audio cassette with Dolby-B Noise Reduction, alerted engineers to the need for a weighting curve that gave subjectively meaningful results on the typical random noise that limited the performance of broadcast circuits, equipment and radio circuits. A-weighting was not giving consistent results, especially on FM radio transmissions and Compact Cassette recording where preemphasis of high frequencies was resulting in increased noise readings that did not correlate with subjective effect. Early efforts to produce a better weighting curve led to a DIN standard that was adopted for European Hi-Fi equipment measurement for a while.

Experiments in the BBC led to BBC Research Department Report EL-17, The Assessment of Noise in Audio Frequency Circuits, [3] in which experiments on numerous test subjects were reported, using a variety of noises ranging from clicks to tone-bursts to pink noise. Subjects were asked to compare these with a 1 kHz tone, and final scores were then compared with measured noise levels using various combinations of weighting filter and quasi-peak detector then in existence (such as those defined in a now discontinued German DIN standard). This led to the CCIR-468 standard which defined a new weighting curve and quasi-peak rectifier.

The origin of the current ITU-R 468 weighting curve can be traced to 1956. The 1968 BBC EL-17 report discusses several weighting curves, including one identified as D.P.B. which was chosen as superior to the alternatives: A.S.A, C.C.I.F and O.I.R.T. The report's graph of the DPB curve is identical to that of the ITU-R 468 curve, except that the latter extends to slightly lower and higher frequencies. The BBC report states that this curve was given in a "contribution by the D.B.P. (The Telephone Administration of the Federal German Republic) in the Red Book Vol. 1 1957 covering the first plenary assembly of the CCITT (Geneva 1956)". D.B.P. is Deutsche Bundespost, the German post office which provides telephone service in Germany as the GPO does in the UK. The BBC report states "this characteristic is based on subjective tests described by Belger." and cites a 1953 paper by E. Belger.

Dolby Laboratories took up the new CCIR-468 weighting for use in measuring noise on their noise reduction systems, both in cinema (Dolby A) and on cassette decks (Dolby B), where other methods of measurement were failing to show up the advantage of such noise reduction. Some Hi-Fi column writers took up 468 weighting enthusiastically, observing that it reflected the roughly 10 dB improvement in noise observed subjectively on cassette recordings when using Dolby B while other methods could indicate an actual worsening in some circumstances, because they did not sufficiently attenuate noise above 10 kHz.

Standards

CCIR Recommendation 468-1 was published soon after this report, and appears to have been based on the BBC work. Later versions up to CCIR 468-4 differed only in minor changes to permitted tolerances. This standard was then incorporated into many other national and international standards (IEC, BSI, JIS, ITU) and adopted widely as the standard method for measuring noise, in broadcasting, professional audio, and 'Hi-Fi' specifications throughout the 1970s. When the CCIR ceased to exist, the standard was officially taken over by the ITU-R (International Telecommunication Union). Current work on this standard occurs primarily in the maintenance of IEC 60268, the international standard for sound systems.

The CCIR curve differs greatly from A-weighting in the 5 to 8 kHz region where it peaks to +12.2 dB at 6.3 kHz, the region in which we appear to be extremely sensitive to noise. While it has been said (incorrectly) that the difference is due to a requirement for assessing noise intrusiveness in the presence of programme material, rather than just loudness, the BBC report makes clear the fact that this was not the basis of the experiments. The real reason for the difference probably relates to the way in which our ears analyse sounds in terms of spectral content along the cochlea. This behaves like a set of closely spaced filters with a roughly constant Q factor, that is, bandwidths proportional to their centre frequencies. High frequency hair cells would therefore be sensitive to a greater proportion of the total energy in noise than low frequency hair cells. Though hair-cell responses are not exactly constant Q, and matters are further complicated by the way in which the brain integrates adjacent hair-cell outputs, the resultant effect appears roughly as a tilt centred on 1 kHz imposed on the A-weighting.

Dependent on spectral content, 468-weighted measurements of noise are generally about 11 dB higher than A-weighted, and this is probably a factor in the recent trend away from 468-weighting in equipment specifications as cassette tape use declines.

It is important to realise that the 468 specification covers both weighted and 'unweighted' (using a 22 Hz to 22 kHz 18 dB/octave bandpass filter) measurement and that both use a very special quasi-peak rectifier with carefully devised dynamics (A-weighting uses RMS detection for no particular reason[ citation needed ]). Rather than having a simple 'integration time' this detector requires implementation with two cascaded 'peak followers' each with different attack time-constants carefully chosen to control the response to both single and repeating tone-bursts of various durations. This ensures that measurements on impulsive noise take proper account of our reduced hearing sensitivity to short bursts. This quasi-peak measurement is also called psophometric weighting.

This was once more important because outside broadcasts were carried over 'music circuits' that used telephone lines, with clicks from Strowger and other electromechanical telephone exchanges. It now finds fresh relevance in the measurement of noise on computer 'Audio Cards' which commonly suffer clicks as drives start and stop.

Present usage of 468-weighting

468-weighting is also used in weighted distortion measurement at 1 kHz. Weighting the distortion residue after removal of the fundamental emphasises high-order harmonics, but only up to 10 kHz or so where the ears response falls off. This results in a single measurement (sometimes called distortion residue measurement) which has been claimed to correspond well with subjective effect even for power amplifiers where crossover distortion is known to be far more audible than normal THD (total harmonic distortion) measurements would suggest.

468-weighting is still demanded by the BBC and many other broadcasters, [4] with increasing awareness of its existence and the fact that it is more valid on random noise where pure tones do not exist.[ citation needed ]

Often both A-weighted and 468-weighted figures are quoted for noise, especially in microphone specifications.

While not intended for this application, the 468 curve has also been used (offset to place the 0 dB point at 2 kHz rather than 1 kHz) as "M weighting" in standards such as ISO 21727 [5] intended to gauge loudness or annoyance of cinema soundtracks. This application of the weighting curve does not include the quasi-peak detector specified in the ITU standard.

Summary of specification

Note: this is not the full definitive standard.

Weighting curve specification (weighted measurement)

The weighting curve is specified by both a circuit diagram of a weighting network and a table of amplitude responses.

Itu-r 468-circuit.png

Above is the ITU-R 468 Weighting Filter Circuit Diagram. The source and sink impedances are both 600 ohms (resistive), as shown in the diagram. The values are taken directly from the ITU-R 468 specification. Note that since this circuit is purely passive, it cannot create the additional 12 dB gain required; any results must be corrected by a factor of 8.1333, or +18.2 dB.

Table of amplitude responses:

Frequency (Hz)Response (dB)
31.5-29.9
63-23.9
100-19.8
200-13.8
400-7.8
800-1.9
1,0000.0
2,000+5.6
3,150+9.0
4,000+10.5
5,000+11.7
6,300+12.2
7,100+12.0
8,000+11.4
9,000+10.1
10,000+8.1
12,5000.0
14,000-5.3
16,000-11.7
20,000-22.2
31,500-42.7

The values of the amplitude response table slightly differ from those resulting from the circuit diagram, e.g. because of the finite resolution of the numerical values. In the standard it is said that the 33.06 nF capacitor may be adjusted or an active filter may be used.

Modeling at hand the circuit above and some calculus give this formula to get the amplitude response in dB for any given frequency value :

where

Tone-burst response requirements

5 kHz single bursts:

Burst Duration (ms)Steady Signal Reading (dB)
200-1.9
100-3.3
50-4.6
20-5.7
10-6.4
5-8.0
2-11.5
1-15.4

Repetitive tone-burst response

5 ms, 5 kHz bursts at repetition rate:

Number Of Bursts per Second (s−1)Steady Signal Reading (dB)
2-6.40
10-2.30
100-0.25

Unweighted measurement

Uses 22 Hz HPF and 22 kHz LPF 18 dB/decade or greater.

(Tables to be added)

See also

Related Research Articles

The decibel is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a power ratio of 101/10 or root-power ratio of 10120.

<span class="mw-page-title-main">Weighting filter</span>

A weighting filter is used to emphasize or suppress some aspects of a phenomenon compared to others, for measurement or other purposes.

A noise weighting is a specific amplitude-vs.-frequency characteristic that is designed to allow subjectively valid measurement of noise. It emphasises the parts of the spectrum that are most important.

The total harmonic distortion is a measurement of the harmonic distortion present in a signal and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. Distortion factor, a closely related term, is sometimes used as a synonym.

<span class="mw-page-title-main">Audio system measurements</span> Means of quantifying system performance

Audio system measurements are a means of quantifying system performance. These measurements are made for several purposes. Designers take measurements so that they can specify the performance of a piece of equipment. Maintenance engineers make them to ensure equipment is still working to specification, or to ensure that the cumulative defects of an audio path are within limits considered acceptable. Audio system measurements often accommodate psychoacoustic principles to measure the system in a way that relates to human hearing.

<span class="mw-page-title-main">Loudness</span> Subjective perception of sound pressure

In acoustics, loudness is the subjective perception of sound pressure. More formally, it is defined as the "attribute of auditory sensation in terms of which sounds can be ordered on a scale extending from quiet to loud". The relation of physical attributes of sound to perceived loudness consists of physical, physiological and psychological components. The study of apparent loudness is included in the topic of psychoacoustics and employs methods of psychophysics.

<span class="mw-page-title-main">Equal-loudness contour</span> Frequency characteristics of hearing and perceived volume

An equal-loudness contour is a measure of sound pressure level, over the frequency spectrum, for which a listener perceives a constant loudness when presented with pure steady tones. The unit of measurement for loudness levels is the phon and is arrived at by reference to equal-loudness contours. By definition, two sine waves of differing frequencies are said to have equal-loudness level measured in phons if they are perceived as equally loud by the average young person without significant hearing impairment.

Noise shaping is a technique typically used in digital audio, image, and video processing, usually in combination with dithering, as part of the process of quantization or bit-depth reduction of a signal. Its purpose is to increase the apparent signal-to-noise ratio of the resultant signal. It does this by altering the spectral shape of the error that is introduced by dithering and quantization; such that the noise power is at a lower level in frequency bands at which noise is considered to be less desirable and at a correspondingly higher level in bands where it is considered to be more desirable. A popular noise shaping algorithm used in image processing is known as ‘Floyd Steinberg dithering’; and many noise shaping algorithms used in audio processing are based on an ‘Absolute threshold of hearing’ model.

A weighting curve is a graph of a set of factors, that are used to 'weight' measured values of a variable according to their importance in relation to some outcome. An important example is frequency weighting in sound level measurement where a specific set of weighting curves known as A-, B-, C-, and D-weighting as defined in IEC 61672 are used. Unweighted measurements of sound pressure do not correspond to perceived loudness because the human ear is less sensitive at low and high frequencies, with the effect more pronounced at lower sound levels. The four curves are applied to the measured sound level, for example by the use of a weighting filter in a sound level meter, to arrive at readings of loudness in phons or in decibels (dB) above the threshold of hearing.

A rumble is a continuous deep, resonant sound, such as the sound made by heavy vehicles or thunder. In the context of audio reproduction rumble refers to a low frequency sound from the bearings inside a turntable. This is most noticeable in low quality turntables with ball bearings. Higher quality turntables use slide bearings, minimizing rumble.

<span class="mw-page-title-main">Weighting</span>

The process of weighting involves emphasizing the contribution of particular aspects of a phenomenon over others to an outcome or result; thereby highlighting those aspects in comparison to others in the analysis. That is, rather than each variable in the data set contributing equally to the final result, some of the data is adjusted to make a greater contribution than others. This is analogous to the practice of adding (extra) weight to one side of a pair of scales in order to favour either the buyer or seller.

In acoustics, noise measurement can be for the purpose of measuring environmental noise or measuring noise in the workplace. Applications include monitoring of construction sites, aircraft noise, road traffic noise, entertainment venues and neighborhood noise. One of the definitions of noise covers all "unwanted sounds". When sound levels reach a high enough intensity, the sound, whether it is wanted or unwanted, may be damaging to hearing. Environmental noise monitoring is the measurement of noise in an outdoor environment caused by transport, industry and recreational activities. The laws and limits governing environmental noise monitoring differ from country to country.

Programme level refers to the signal level that an audio source is transmitted or recorded at, and is important in audio if listeners of Compact Discs (CDs), radio and television are to get the best experience, without excessive noise in quiet periods or distortion of loud sounds. Programme level is often measured using a peak programme meter or a VU meter.

Measurement of wow and flutter is carried out on audio tape machines, cassette recorders and players, and other analog recording and reproduction devices with rotary components This measurement quantifies the amount of 'frequency wobble' present in subjectively valid terms. Turntables tend to suffer mainly slow wow. In digital systems, which are locked to crystal oscillators, variations in clock timing are referred to as wander or jitter, depending on speed.

<span class="mw-page-title-main">Psophometric weighting</span>

Psophometric weighting refers to any weighting curve used in the measurement of noise. In the field of audio engineering it has a more specific meaning, referring to noise weightings used especially in measuring noise on telecommunications circuits. Key standards are ITU-T O.41 and C-message weighting as shown here.

Audio noise measurement is a process carried out to assess the quality of audio equipment, such as the kind used in recording studios, broadcast engineering, and in-home high fidelity.

A quasi-peak detector is a type of electronic detector or rectifier. Quasi-peak detectors for specific purposes have usually been standardized with mathematically precisely defined dynamic characteristics of attack time, integration time, and decay time or fall-back time.

Dialnorm is the metadata parameter that controls playback gain within the Dolby Laboratories Dolby Digital (AC-3) audio compression system. Dialnorm stands for dialog normalization. Dialnorm is an integer value with range 1 to 31 corresponding to a playback gain of -30 to 0 dB (unity) respectively. Higher values afford more headroom and are appropriate for dynamic material such as an action film.

<span class="mw-page-title-main">A-weighting</span> Frequency response curves used in sound pressure level measurement

A-weighting is the most commonly used of a family of curves defined in the International standard IEC 61672:2003 and various national standards relating to the measurement of sound pressure level. A-weighting is applied to instrument-measured sound levels in an effort to account for the relative loudness perceived by the human ear, as the ear is less sensitive to low audio frequencies. It is employed by arithmetically adding a table of values, listed by octave or third-octave bands, to the measured sound pressure levels in dB. The resulting octave band measurements are usually added to provide a single A-weighted value describing the sound; the units are written as dB(A). Other weighting sets of values – B, C, D and now Z – are discussed below.

References

  1. "RECOMMENDATION ITU-R BS.468-4 - Measurement of audio-frequency noise voltage" (PDF). www.itu.int. International Telecommunication Union . Retrieved 18 October 2016.
  2. "1910.95 - Occupational noise exposure. | Occupational Safety and Health Administration". www.osha.gov. Retrieved 2018-10-28.
  3. BBC Research Department Report - The assessment of noise in audio-frequency circuits. http://downloads.bbc.co.uk/rd/pubs/reports/1968-08.pdf
  4. "468 - Weighting in Detail". Lindos. Retrieved 2011-07-12.
  5. "ISO 21727:2016(en) Cinematography — Method of measurement of perceived loudness of short duration motion-picture audio material". ISO. 2016. Retrieved 2018-07-28.

Further reading