Loss-of-coolant accident

Last updated
A simulated animation of a core melt in a light water reactor after a loss-of-coolant accident. After reaching an extremely high temperature, the nuclear fuel and accompanying cladding liquefies and relocates itself to the bottom of the reactor pressure vessel. LWR Meltdown.gif
A simulated animation of a core melt in a light water reactor after a loss-of-coolant accident. After reaching an extremely high temperature, the nuclear fuel and accompanying cladding liquefies and relocates itself to the bottom of the reactor pressure vessel.

A loss-of-coolant accident (LOCA) is a mode of failure for a nuclear reactor; if not managed effectively, the results of a LOCA could result in reactor core damage. Each nuclear plant's emergency core cooling system (ECCS) exists specifically to deal with a LOCA.

Contents

Nuclear reactors generate heat internally; to remove this heat and convert it into useful electrical power, a coolant system is used. If this coolant flow is reduced, or lost altogether, the nuclear reactor's emergency shutdown system is designed to stop the fission chain reaction. However, due to radioactive decay, the nuclear fuel will continue to generate a significant amount of heat. The decay heat produced by a reactor shutdown from full power is initially equivalent to about 5 to 6% of the thermal rating of the reactor. [1] If all of the independent cooling trains of the ECCS fail to operate as designed, this heat can increase the fuel temperature to the point of damaging the reactor.

Under operating conditions, a reactor may passively (that is, in the absence of any control systems) increase or decrease its power output in the event of a LOCA or of voids appearing in its coolant system (by water boiling, for example). This is measured by the coolant void coefficient. Most modern nuclear power plants have a negative void coefficient, indicating that as water turns to steam, power instantly decreases. Two exceptions are the Soviet RBMK and the Canadian CANDU. Boiling water reactors, on the other hand, are designed to have steam voids inside the reactor vessel.

Modern reactors are designed to prevent and withstand loss of coolant, regardless of their void coefficient, using various techniques. Some, such as the pebble bed reactor, passively slow down the chain reaction when coolant is lost; others have extensive safety systems to rapidly shut down the chain reaction, and may have extensive passive safety systems (such as a large thermal heat sink around the reactor core, passively-activated backup cooling/condensing systems, or a passively cooled containment structure) that mitigate the risk of further damage.

Progression after loss-of-coolant

A great deal of work goes into the prevention of a serious core event. If such an event were to occur, three different physical processes are expected to increase the time between the start of the accident and the time when a large release of radioactivity could occur. These three factors would provide additional time to the plant operators in order to mitigate the result of the event:

  1. The time required for the water to boil away (coolant, moderator). Assuming that at the moment that the accident occurs the reactor will be SCRAMed (immediate and full insertion of all control rods), so reducing the thermal power input and further delaying the boiling.
  2. The time required for the fuel to melt. After the water has boiled, then the time required for the fuel to reach its melting point will be dictated by the heat input due to decay of fission products, the heat capacity of the fuel and the melting point of the fuel.
  3. The time required for the molten fuel to breach the primary pressure boundary. The time required for the molten metal of the core to breach the primary pressure boundary (in light water reactors this is the pressure vessel; in CANDU and RBMK reactors this is the array of pressurized fuel channels; in PHWR reactors like Atucha I, it will be a double barrier of channels and the pressure vessel) will depend on temperatures and boundary materials. Whether or not the fuel remains critical in the conditions inside the damaged core or beyond will play a significant role.

Fukushima Daiichi nuclear disaster

The Fukushima Daiichi nuclear disaster in 2011 occurred due to a loss-of-coolant accident. The circuits that provided electrical power to the coolant pumps failed causing a loss-of-core-cooling that was critical for the removal of residual decay heat which is produced even after active reactors are shut down and nuclear fission has ceased. The loss of reactor core cooling led to three nuclear meltdowns, three hydrogen explosions and the release of radioactive contamination.

The hydrogen explosions can be directly attributed to the oxidation of zirconium by steam in the fuel claddings as a result of the loss-of-coolant.

Fuel claddings

Most reactors use a zirconium alloy as the material for fuel rod claddings due to its corrosion-resistance and low neutron absorption cross-section. However, one major drawback of zirconium alloys is that, when overheated, they oxidize and produce a runaway exothermic reaction with water (steam) that leads to the production of hydrogen: . Such reactions are what led to the hydrogen explosions in the Fukushima Daiichi nuclear disaster.

Rupture Behavior

The residual decay heat causes rapid increase in temperature and internal pressure of the fuel cladding which leads to plastic deformation and subsequent bursting. During a loss-of-coolant accident, zirconium-based fuel claddings undergo high temperature oxidation, phase transformation, and creep deformation simultaneously. [3] These mechanisms have been extensively studied by researchers using burst criterion models. In one study, researchers developed a burst criterion for Zircaloy-4 fuel claddings and determined that the effect of the steam environment on failure of the claddings is negligible at low temperatures. However, as the burst temperature increases, rapid oxidation of Zircaloy-4 claddings occurs leading to a sharp decrease in its ductility. In fact, at higher temperatures the burst strain pretty much drops to zero signifying that the oxidized cladding becomes so brittle locally that it is predicted to fail without any further deformation or straining.

The amount of oxygen picked up by the zirconium alloy depends on the exposure time to steam (H2O) before rupture. For rapid ruptures due to high heating rates and internal pressures, there is negligible oxidation. However, oxidation plays an important role in fracture for low heating rates and low initial internal pressures.

Oxidation Resistance Coatings

The zirconium alloy substrates can be coated to improve their oxidation resistance. In one study, researchers coated a Zirlo substrate with Ti2AlC MAX phase using a hybrid arc/magnetron sputtering technique followed by an annealing treatment. They subsequently investigated the mechanical properties and oxidation resistance in pure steam conditions at 1000 °C, 1100 °C, and 1200 °C under different oxidation times. Results showed that coating the Zirlo substrate with Ti2AlC caused in increase in hardness and elastic modulus compared to the bare substrate. Additionally, the high-temperature oxidation resistance was significantly improved. The benefits of Ti2AlC over other coating materials are that it has excellent stability under neutron irradiation, a lower thermal expansion coefficient, better thermal shock resistance, and higher temperature oxidation resistance. [4] Table 1 provides a good indication of the improved mechanical properties as a result of the coating and improved resistance to plastic deformation.

Table 1. Mechanical properties of substrate and coated material
Hardness (GPa)Elastic Modulus (GPa)H/EH3/E2 (GPa)
Substrate5.39 ± 0.1129.92 ± 3.10.040.01
Ti2AlC coated material14.24±0.1230.8±3.10.060.05

Another recent study evaluated Cr and FeCrAl coatings (deposited on Zircaloy-4 using atmospheric plasma spraying technology) under simulated loss-of-coolant conditions. [5] The Cr coating displayed superior oxidation resistance. The formation of a compact Cr2O3 layer on the Cr-coating acted as an oxygen diffusion barrier that protected the Zr substrate from oxidation whereas the FeCrAl coating degraded due to inter-diffusion between the coating and the Zr substrate at high temperature thereby allowing Zr to still oxidize.

See also

Related Research Articles

<span class="mw-page-title-main">Nuclear reactor</span> Device used to initiate and control a nuclear chain reaction

A nuclear reactor is a device used to initiate and control a fission nuclear chain reaction or nuclear fusion reactions. Nuclear reactors are used at nuclear power plants for electricity generation and in nuclear marine propulsion. Heat from nuclear fission is passed to a working fluid, which in turn runs through steam turbines. These either drive a ship's propellers or turn electrical generators' shafts. Nuclear generated steam in principle can be used for industrial process heat or for district heating. Some reactors are used to produce isotopes for medical and industrial use, or for production of weapons-grade plutonium. As of 2022, the International Atomic Energy Agency reports there are 422 nuclear power reactors and 223 nuclear research reactors in operation around the world.

<span class="mw-page-title-main">Pressurized water reactor</span> Type of nuclear reactor

A pressurized water reactor (PWR) is a type of light-water nuclear reactor. PWRs constitute the large majority of the world's nuclear power plants. In a PWR, the primary coolant (water) is pumped under high pressure to the reactor core where it is heated by the energy released by the fission of atoms. The heated, high pressure water then flows to a steam generator, where it transfers its thermal energy to lower pressure water of a secondary system where steam is generated. The steam then drives turbines, which spin an electric generator. In contrast to a boiling water reactor (BWR), pressure in the primary coolant loop prevents the water from boiling within the reactor. All light-water reactors use ordinary water as both coolant and neutron moderator. Most use anywhere from two to four vertically mounted steam generators; VVER reactors use horizontal steam generators.

<span class="mw-page-title-main">Nuclear meltdown</span> Reactor accident due to core overheating

A nuclear meltdown is a severe nuclear reactor accident that results in core damage from overheating. The term nuclear meltdown is not officially defined by the International Atomic Energy Agency or by the United States Nuclear Regulatory Commission. It has been defined to mean the accidental melting of the core of a nuclear reactor, however, and is in common usage a reference to the core's either complete or partial collapse.

In nuclear engineering, the void coefficient is a number that can be used to estimate how much the reactivity of a nuclear reactor changes as voids form in the reactor moderator or coolant. Net reactivity in a reactor is the sum total of multiple contributions, of which the void coefficient is but one. Reactors in which either the moderator or the coolant is a liquid typically will have a void coefficient value that is either negative or positive. Reactors in which neither the moderator nor the coolant is a liquid will have a void coefficient value equal to zero. It is unclear how the definition of "void" coefficient applies to reactors in which the moderator/coolant is neither liquid nor gas.

<span class="mw-page-title-main">Light-water reactor</span> Type of nuclear reactor that uses normal water

The light-water reactor (LWR) is a type of thermal-neutron reactor that uses normal water, as opposed to heavy water, as both its coolant and neutron moderator; furthermore a solid form of fissile elements is used as fuel. Thermal-neutron reactors are the most common type of nuclear reactor, and light-water reactors are the most common type of thermal-neutron reactor.

Passive nuclear safety is a design approach for safety features, implemented in a nuclear reactor, that does not require any active intervention on the part of the operator or electrical/electronic feedback in order to bring the reactor to a safe shutdown state, in the event of a particular type of emergency. Such design features tend to rely on the engineering of components such that their predicted behaviour would slow down, rather than accelerate the deterioration of the reactor state; they typically take advantage of natural forces or phenomena such as gravity, buoyancy, pressure differences, conduction or natural heat convection to accomplish safety functions without requiring an active power source. Many older common reactor designs use passive safety systems to a limited extent, rather, relying on active safety systems such as diesel powered motors. Some newer reactor designs feature more passive systems; the motivation being that they are highly reliable and reduce the cost associated with the installation and maintenance of systems that would otherwise require multiple trains of equipment and redundant safety class power supplies in order to achieve the same level of reliability. However, weak driving forces that power many passive safety features can pose significant challenges to effectiveness of a passive system, particularly in the short term following an accident.

<span class="mw-page-title-main">Integral fast reactor</span> Nuclear reactor design

The integral fast reactor is a design for a nuclear reactor using fast neutrons and no neutron moderator. IFR would breed more fuel and is distinguished by a nuclear fuel cycle that uses reprocessing via electrorefining at the reactor site.

<span class="mw-page-title-main">Molten salt reactor</span> Type of nuclear reactor cooled by molten material

A molten salt reactor (MSR) is a class of nuclear fission reactor in which the primary nuclear reactor coolant and/or the fuel is a mixture of molten salt with a fissionable material.

<span class="mw-page-title-main">Nuclear fuel</span> Material fuelling nuclear reactors

Nuclear fuel is material used in nuclear power stations to produce heat to power turbines. Heat is created when nuclear fuel undergoes nuclear fission.

Generation IVreactors are nuclear reactor design technologies that are envisioned as successors of generation III reactors. The Generation IV International Forum (GIF) – an international organization that coordinates the development of generation IV reactors – specifically selected six reactor technologies as candidates for generation IV reactors. The designs target improved safety, sustainability, efficiency, and cost. The first commercial Gen IV plants are not expected before 2040–2050, although the World Nuclear Association in 2015 suggested that some might enter commercial operation before 2030.

Zirconium alloys are solid solutions of zirconium or other metals, a common subgroup having the trade mark Zircaloy. Zirconium has very low absorption cross-section of thermal neutrons, high hardness, ductility and corrosion resistance. One of the main uses of zirconium alloys is in nuclear technology, as cladding of fuel rods in nuclear reactors, especially water reactors. A typical composition of nuclear-grade zirconium alloys is more than 95 weight percent zirconium and less than 2% of tin, niobium, iron, chromium, nickel and other metals, which are added to improve mechanical properties and corrosion resistance.

<span class="mw-page-title-main">Sodium-cooled fast reactor</span> Type of nuclear reactor cooled by molten sodium

A sodium-cooled fast reactor is a fast neutron reactor cooled by liquid sodium.

This page describes how uranium dioxide nuclear fuel behaves during both normal nuclear reactor operation and under reactor accident conditions, such as overheating. Work in this area is often very expensive to conduct, and so has often been performed on a collaborative basis between groups of countries, usually under the aegis of the Organisation for Economic Co-operation and Development's Committee on the Safety of Nuclear Installations (CSNI).

The three primary objectives of nuclear reactor safety systems as defined by the U.S. Nuclear Regulatory Commission are to shut down the reactor, maintain it in a shutdown condition and prevent the release of radioactive material.

A nuclear reactor coolant is a coolant in a nuclear reactor used to remove heat from the nuclear reactor core and transfer it to electrical generators and the environment. Frequently, a chain of two coolant loops are used because the primary coolant loop takes on short-term radioactivity from the reactor.

<span class="mw-page-title-main">Corium (nuclear reactor)</span> Material in core during nuclear meltdown

Corium, also called fuel-containing material (FCM) or lava-like fuel-containing material (LFCM), is a material that is created in a nuclear reactor core during a nuclear meltdown accident. Resembling lava in consistency, it consists of a mixture of nuclear fuel, fission products, control rods, structural materials from the affected parts of the reactor, products of their chemical reaction with air, water, steam, and, in the event that the reactor vessel is breached, molten concrete from the floor of the reactor room.

Boiling water reactor safety systems are nuclear safety systems constructed within boiling water reactors in order to prevent or mitigate environmental and health hazards in the event of accident or natural disaster.

<span class="mw-page-title-main">Integral Molten Salt Reactor</span>

The Integral Molten Salt Reactor (IMSR) is a nuclear power plant design targeted at developing a commercial product for the small modular reactor (SMR) market. It employs molten salt reactor technology which is being developed by the Canadian company Terrestrial Energy. It is based closely on the denatured molten salt reactor (DMSR), a reactor design from Oak Ridge National Laboratory. It also incorporates elements found in the SmAHTR, a later design from the same laboratory. The IMSR belongs to the DMSR class of molten salt reactors (MSR) and hence is a "burner" reactor that employs a liquid fuel rather than a conventional solid fuel; this liquid contains the nuclear fuel and also serves as primary coolant.

<span class="mw-page-title-main">Stable salt reactor</span>

The Stable Salt Reactor (SSR) is a nuclear reactor design under development by Moltex Energy Canada Inc. and its subsidiary Moltex Energy USA LLC, based in Canada, the United States, and the United Kingdom, as well as MoltexFLEX Ltd., based in the United Kingdom.

<span class="mw-page-title-main">Organic nuclear reactor</span> Nuclear reactor that uses organic liquids for cooling and neutron moderation

An organic nuclear reactor, or organic cooled reactor (OCR), is a type of nuclear reactor that uses some form of organic fluid, typically a hydrocarbon substance like polychlorinated biphenyl (PCB), for cooling and sometimes as a neutron moderator as well.

References

  1. "DOE fundamentals handbook - Decay heat, Nuclear physics and reactor theory, vol. 2, module 4, p. 61" . Retrieved 20 April 2016.
  2. Peterson, Otis G. (2008-03-20). "Patent Application 11/804450: Self-regulating nuclear power module". United States Patent Application Publication. United States Patent and Trademark Office, Federal Government of the United States, Washington, DC, USA. Retrieved 2009-09-05.
  3. Suman, Siddharth; Khan, Mohd. Kaleem; Pathak, Manabendra; Singh, R. N.; Chakravartty, J. K. (2016-10-01). "Rupture behaviour of nuclear fuel cladding during loss-of-coolant accident". Nuclear Engineering and Design. 307: 319–327. doi:10.1016/j.nucengdes.2016.07.022. ISSN   0029-5493.
  4. Li, Wentao; Wang, Zhenyu; Shuai, Jintao; Xu, Beibei; Wang, Aiying; Ke, Peiling (2019-08-01). "A high oxidation resistance Ti2AlC coating on Zirlo substrates for loss-of-coolant accident conditions". Ceramics International. 45 (11): 13912–13922. doi:10.1016/j.ceramint.2019.04.089. ISSN   0272-8842. S2CID   149686337.
  5. Wang, Yiding; Zhou, Wancheng; Wen, Qinlong; Ruan, Xingcui; Luo, Fa; Bai, Guanghai; Qing, Yuchang; Zhu, Dongmei; Huang, Zhibin; Zhang, Yanwei; Liu, Tong (2018-06-25). "Behavior of plasma sprayed Cr coatings and FeCrAl coatings on Zr fuel cladding under loss-of-coolant accident conditions". Surface and Coatings Technology. 344: 141–148. doi:10.1016/j.surfcoat.2018.03.016. ISSN   0257-8972. S2CID   139798895.