Plasma afterglow

Last updated

A plasma afterglow (also afterglow) is the radiation emitted from a plasma after the source of ionization is removed. [1] The external electromagnetic fields that sustained the plasma glow are absent or insufficient to maintain the discharge in the afterglow. A plasma afterglow can either be a temporal, due to an interrupted (pulsed) plasma source, or spatial, due to a distant plasma source. In the afterglow, plasma-generated species de-excite and participate in secondary chemical reactions that tend to form stable species. Depending on the gas composition, super-elastic collisions may continue to sustain the plasma in the afterglow for a while by releasing the energy stored in rovibronic degrees of freedom of the atoms and molecules of the plasma. Especially in molecular gases, the plasma chemistry in the afterglow is significantly different from the plasma glow. The afterglow of a plasma is still a plasma and as thus retains most of the properties of a plasma.

Contents

History

The first published pictures of plasma afterglow were taken in 1953. [2]

Helium afterglow, one of the most commonly used forms of afterglow, was first described in 1963 by Arthur L. Schmeltekopf Jr. and H. P. Broida. [3]

The first flowing afterglow ionization studies began in the early 1960s in an effort to understand atmospheric ion chemistry. At the time stationary afterglow studies had already been done however this approach was limited by lack of versatility and lacked consistency as studies done prior to 1964 showed common atmospheric reactions to have drastically differing reaction rates between studies. Flowing-afterglow was then used to more precisely describe the rate constants of common atmospheric reactions

Remote plasma

Basic remote plasma diagram B-pab-remoteplasmasystem.svg
Basic remote plasma diagram

A remote plasma refers to a plasma that is spatially separated from the external electromagnetic fields that initiate the discharge. An afterglow is a remote plasma if the plasma is channeled away from the original plasma source.

An advantage that remote plasma has over temporal plasma is that remote plasma can be used as a continuous plasma source and thus has more applications in supplying reagent ions for most systems.

Remote plasmas are often used in the field of analytical chemistry when a constant stream of ions is required. They are also very commonly used a method of cleaning complex vacuum systems without having to take them apart.

Temporal plasma

A temporal plasma refers to an afterglow from a plasma source that is time delineated. Removing the source of excitation allows for an afterglow to be present in the same space that the initial plasma was excited for a short time.

An advantage that temporal plasma has over remote plasma is that it can be contained in a closed system and thus makes controlling the temperature and pressure is easier.

Temporal plasma is often used to replicate ionic reactions in atmospheric conditions in a controlled environment.

Applications

Flowing afterglow

A flowing afterglow is an ion source that is used to create ions in a flow of inert gas, typically helium or argon. [4] [5] [6] Flowing afterglow ion sources usually consist of a dielectric discharge that gases are channeled through to be excited and thus made into plasma. Flowing afterglow ion sources can be coupled with a selected-ion flow-tube for selection of reactant ions. [7] When this ion source is coupled with mass spectrometry it is referred to as flowing afterglow mass spectrometry.

Flowing-afterglow mass spectrometry uses a flowing afterglow to create protonated water cluster ions in a helium or argon carrier gas in a flow tube that react with sample molecules that are measured by a mass spectrometer downstream. [8] These systems can be used for trace gas analysis. This works by keeping the initial ionization source spatially separated from the target analyte and channeling the afterglow of the initial ionization towards the analyte. Analytes are added downstream to create ion products. Ions Detection of ions is usually accomplished using a mass spectrometer or by optical spectroscopy. [9]

Stationary afterglow

Stationary afterglow (SA) is a technique for studying remote plasma that consist of a gaseous mixture inside a bulb that is subjected to an ionizing pulse. After said ionizing pulse the ion composition of the mixture is measured as a function of time at the wall of the containing bulb. [5] Stationary afterglow methods are often used to study atmospheric reactions as they mimic atmospheric conditions in a controlled environment.

Cleaning and sterilization

Plasma afterglow has shown to be an effective means of cleaning and sterilizing difficult to take apart machinery and glassware. [10] [11] Plasma cleaning uses remote plasma sources to generate an afterglow that is ventilated into the system to be cleaned and then the afterglow ions react with the contaminants. When oxygen is used as the carrier gas, ionized oxygen species react with heavier organic compounds to form H2O, CO2, and CO. These products are then easily vented from the system effectively removing organic contaminants from the system. [12] This provides the advantage of not having to take systems apart and thus saves time on disassembly and on vacuum systems it saves time changing the pressure of the system.

This plasma cleaning method is especially effective for chemical vapor deposition methods where cleanliness is a key part of productivity. [13]

See also

Related Research Articles

<span class="mw-page-title-main">Inductively coupled plasma mass spectrometry</span> Type of mass spectrometry that uses an inductively coupled plasma to ionize the sample

Inductively coupled plasma mass spectrometry (ICP-MS) is a type of mass spectrometry that uses an inductively coupled plasma to ionize the sample. It atomizes the sample and creates atomic and small polyatomic ions, which are then detected. It is known and used for its ability to detect metals and several non-metals in liquid samples at very low concentrations. It can detect different isotopes of the same element, which makes it a versatile tool in isotopic labeling.

<span class="mw-page-title-main">Mass spectrometry</span> Analytical technique based on determining mass to charge ratio of ions

Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures.

<span class="mw-page-title-main">Ion source</span> Device that creates charged atoms and molecules (ions)

An ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines.

<span class="mw-page-title-main">Electrospray ionization</span> Technique used in mass spectroscopy

Electrospray ionization (ESI) is a technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol. It is especially useful in producing ions from macromolecules because it overcomes the propensity of these molecules to fragment when ionized. ESI is different from other ionization processes since it may produce multiple-charged ions, effectively extending the mass range of the analyser to accommodate the kDa-MDa orders of magnitude observed in proteins and their associated polypeptide fragments.

<span class="mw-page-title-main">Selected-ion flow-tube mass spectrometry</span>

Selected-ion flow-tube mass spectrometry (SIFT-MS) is a quantitative mass spectrometry technique for trace gas analysis which involves the chemical ionization of trace volatile compounds by selected positive precursor ions during a well-defined time period along a flow tube. Absolute concentrations of trace compounds present in air, breath or the headspace of bottled liquid samples can be calculated in real time from the ratio of the precursor and product ion signal ratios, without the need for sample preparation or calibration with standard mixtures. The detection limit of commercially available SIFT-MS instruments extends to the single digit pptv range.

<span class="mw-page-title-main">Chemical ionization</span> Ionization technique used in mass [[spectroscopy]]

Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry. Negative chemical ionization (NCI), charge-exchange chemical ionization, atmospheric-pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) are some of the common variants of the technique. CI mass spectrometry finds general application in the identification, structure elucidation and quantitation of organic compounds as well as some utility in biochemical analysis. Samples to be analyzed must be in vapour form, or else, must be vapourized before introduction into the source.

<span class="mw-page-title-main">Matrix-assisted laser desorption/ionization</span> Ionization technique

In mass spectrometry, matrix-assisted laser desorption/ionization (MALDI) is an ionization technique that uses a laser energy-absorbing matrix to create ions from large molecules with minimal fragmentation. It has been applied to the analysis of biomolecules and various organic molecules, which tend to be fragile and fragment when ionized by more conventional ionization methods. It is similar in character to electrospray ionization (ESI) in that both techniques are relatively soft ways of obtaining ions of large molecules in the gas phase, though MALDI typically produces far fewer multi-charged ions.

<span class="mw-page-title-main">Liquid chromatography–mass spectrometry</span> Analytical chemistry technique

Liquid chromatography–mass spectrometry (LC–MS) is an analytical chemistry technique that combines the physical separation capabilities of liquid chromatography with the mass analysis capabilities of mass spectrometry (MS). Coupled chromatography – MS systems are popular in chemical analysis because the individual capabilities of each technique are enhanced synergistically. While liquid chromatography separates mixtures with multiple components, mass spectrometry provides spectral information that may help to identify each separated component. MS is not only sensitive, but provides selective detection, relieving the need for complete chromatographic separation. LC–MS is also appropriate for metabolomics because of its good coverage of a wide range of chemicals. This tandem technique can be used to analyze biochemical, organic, and inorganic compounds commonly found in complex samples of environmental and biological origin. Therefore, LC–MS may be applied in a wide range of sectors including biotechnology, environment monitoring, food processing, and pharmaceutical, agrochemical, and cosmetic industries. Since the early 2000s, LC–MS has also begun to be used in clinical applications.

<span class="mw-page-title-main">Flowing-afterglow mass spectrometry</span>

Flowing-afterglow mass spectrometry (FA-MS), is an analytical chemistry technique for the sensitive detection of trace gases. Trace gas molecules are ionized by the production and flow of thermalized hydrated hydronium cluster ions in a plasma afterglow of helium or argon carrier gas along a flow tube following the introduction of a humid air sample. These ions react in multiple collisions with water molecules, their isotopic compositions reach equilibrium and the relative magnitudes of their isotopomers are measured by mass spectrometry.

<span class="mw-page-title-main">Ion mobility spectrometry</span> Analytical technique used to separate and identify ionized molecules in the gas phase

Ion mobility spectrometry (IMS) It is a method of conducting analytical research that separates and identifies ionized molecules present in the gas phase based on the mobility of the molecules in a carrier buffer gas. Even though it is used extensively for military or security objectives, such as detecting drugs and explosives, the technology also has many applications in laboratory analysis, including studying small and big biomolecules. IMS instruments are extremely sensitive stand-alone devices, but are often coupled with mass spectrometry, gas chromatography or high-performance liquid chromatography in order to achieve a multi-dimensional separation. They come in various sizes, ranging from a few millimeters to several meters depending on the specific application, and are capable of operating under a broad range of conditions. IMS instruments such as microscale high-field asymmetric-waveform ion mobility spectrometry can be palm-portable for use in a range of applications including volatile organic compound (VOC) monitoring, biological sample analysis, medical diagnosis and food quality monitoring. Systems operated at higher pressure are often accompanied by elevated temperature, while lower pressure systems (1–20 hPa) do not require heating.

<span class="mw-page-title-main">Atmospheric-pressure chemical ionization</span> Ionization method

Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (105 Pa), commonly coupled with high-performance liquid chromatography (HPLC). APCI is a soft ionization method similar to chemical ionization where primary ions are produced on a solvent spray. The main usage of APCI is for polar and relatively less polar thermally stable compounds with molecular weight less than 1500 Da. The application of APCI with HPLC has gained a large popularity in trace analysis detection such as steroids, pesticides and also in pharmacology for drug metabolites.

Gas phase ion chemistry is a field of science encompassed within both chemistry and physics. It is the science that studies ions and molecules in the gas phase, most often enabled by some form of mass spectrometry. By far the most important applications for this science is in studying the thermodynamics and kinetics of reactions. For example, one application is in studying the thermodynamics of the solvation of ions. Ions with small solvation spheres of 1, 2, 3... solvent molecules can be studied in the gas phase and then extrapolated to bulk solution.

In mass spectrometry, direct analysis in real time (DART) is an ion source that produces electronically or vibronically excited-state species from gases such as helium, argon, or nitrogen that ionize atmospheric molecules or dopant molecules. The ions generated from atmospheric or dopant molecules undergo ion-molecule reactions with the sample molecules to produce analyte ions. Analytes with low ionization energy may be ionized directly. The DART ionization process can produce positive or negative ions depending on the potential applied to the exit electrode.

<span class="mw-page-title-main">Thermospray</span>

Thermospray is a soft ionization source by which a solvent flow of liquid sample passes through a very thin heated column to become a spray of fine liquid droplets. As a form of atmospheric pressure ionization in mass spectrometry these droplets are then ionized via a low-current discharge electrode to create a solvent ion plasma. A repeller then directs these charged particles through the skimmer and acceleration region to introduce the aerosolized sample to a mass spectrometer. It is particularly useful in liquid chromatography-mass spectrometry (LC-MS).

<span class="mw-page-title-main">Desorption electrospray ionization</span>

Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples at atmospheric conditions. Coupled ionization sources-MS systems are popular in chemical analysis because the individual capabilities of various sources combined with different MS systems allow for chemical determinations of samples. DESI employs a fast-moving charged solvent stream, at an angle relative to the sample surface, to extract analytes from the surfaces and propel the secondary ions toward the mass analyzer. This tandem technique can be used to analyze forensics analyses, pharmaceuticals, plant tissues, fruits, intact biological tissues, enzyme-substrate complexes, metabolites and polymers. Therefore, DESI-MS may be applied in a wide variety of sectors including food and drug administration, pharmaceuticals, environmental monitoring, and biotechnology.

<span class="mw-page-title-main">Desorption atmospheric pressure photoionization</span>

Desorption atmospheric pressure photoionization (DAPPI) is an ambient ionization technique for mass spectrometry that uses hot solvent vapor for desorption in conjunction with photoionization. Ambient Ionization techniques allow for direct analysis of samples without pretreatment. The direct analysis technique, such as DAPPI, eliminates the extraction steps seen in most nontraditional samples. DAPPI can be used to analyze bulkier samples, such as, tablets, powders, resins, plants, and tissues. The first step of this technique utilizes a jet of hot solvent vapor. The hot jet thermally desorbs the sample from a surface. The vaporized sample is then ionized by the vacuum ultraviolet light and consequently sampled into a mass spectrometer. DAPPI can detect a range of both polar and non-polar compounds, but is most sensitive when analyzing neutral or non-polar compounds. This technique also offers a selective and soft ionization for highly conjugated compounds.

<span class="mw-page-title-main">Ambient ionization</span>

Ambient ionization is a form of ionization in which ions are formed in an ion source outside the mass spectrometer without sample preparation or separation. Ions can be formed by extraction into charged electrospray droplets, thermally desorbed and ionized by chemical ionization, or laser desorbed or ablated and post-ionized before they enter the mass spectrometer.

<span class="mw-page-title-main">Atmospheric pressure photoionization</span> Soft ionization method

Atmospheric pressure photoionization (APPI) is a soft ionization method used in mass spectrometry (MS) usually coupled to liquid chromatography (LC). Molecules are ionized using a vacuum ultraviolet (VUV) light source operating at atmospheric pressure, either by direct absorption followed by electron ejection or through ionization of a dopant molecule that leads to chemical ionization of target molecules. The sample is usually a solvent spray that is vaporized by nebulization and heat. The benefit of APPI is that it ionizes molecules across a broad range of polarity and is particularly useful for ionization of low polarity molecules for which other popular ionization methods such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are less suitable. It is also less prone to ion suppression and matrix effects compared to ESI and APCI and typically has a wide linear dynamic range. The application of APPI with LC/MS is commonly used for analysis of petroleum compounds, pesticides, steroids, and drug metabolites lacking polar functional groups and is being extensively deployed for ambient ionization particularly for explosives detection in security applications.

<span class="mw-page-title-main">Desorption/ionization on silicon</span> Soft laser desorption method

Desorption/ionization on silicon (DIOS) is a soft laser desorption method used to generate gas-phase ions for mass spectrometry analysis. DIOS is considered the first surface-based surface-assisted laser desorption/ionization (SALDI-MS) approach. Prior approaches were accomplished using nanoparticles in a matrix of glycerol, while DIOS is a matrix-free technique in which a sample is deposited on a nanostructured surface and the sample desorbed directly from the nanostructured surface through the adsorption of laser light energy. DIOS has been used to analyze organic molecules, metabolites, biomolecules and peptides, and, ultimately, to image tissues and cells.

References

  1. "Plasma Dictionary". Lawrence Livermore National Laboratory. Archived from the original on 2014-08-17. Retrieved 2014-08-12.
  2. Grün, A. E; Schopper, E; Schumacher, B (1953-12-01). "Electron Shadowgraphs and Afterglow Pictures of Gas Jets at Low Densities". Journal of Applied Physics. 24 (12): 1527–1528. Bibcode:1953JAP....24.1527G. doi: 10.1063/1.1721218 . ISSN   0021-8979.
  3. Schmeltekopf, Arthur L; Broida, H. P (1963-09-01). "Short‐Duration Visible Afterglow in Helium". The Journal of Chemical Physics. 39 (5): 1261–1268. Bibcode:1963JChPh..39.1261S. doi:10.1063/1.1734425. ISSN   0021-9606.
  4. Ferguson, E. E.; Fehsenfeld, F. C.; Schmeltekopf, A. L. (1969). Ion-Molecule Reaction Rates Measured in a Discharge Afterglow. Advances in Chemistry. Vol. 80. pp. 83–91. doi:10.1021/ba-1969-0080.ch006. ISBN   978-0-8412-0081-4. ISSN   0065-2393.
  5. 1 2 Ferguson, Eldon E. (1992). "A Personal history of the early development of the flowing afterglow technique for ion-molecule reaction studies". Journal of the American Society for Mass Spectrometry (Submitted manuscript). 3 (5): 479–486. doi: 10.1016/1044-0305(92)85024-E . ISSN   1044-0305. PMID   24234490.
  6. Bierbaum, Veronica M. (2014). "Go with the flow: Fifty years of innovation and ion chemistry using the flowing afterglow". International Journal of Mass Spectrometry. 377: 456–466. Bibcode:2015IJMSp.377..456B. doi:10.1016/j.ijms.2014.07.021. ISSN   1387-3806.
  7. Squires, Robert R. (1992). "Advances in flowing afterglow and selected-ion flow tube techniques". International Journal of Mass Spectrometry and Ion Processes. 118–119: 503–518. Bibcode:1992IJMSI.118..503S. doi:10.1016/0168-1176(92)85074-A. ISSN   0168-1176.
  8. Smith, David; Španěl, Patrik (2005). "Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis". Mass Spectrometry Reviews. 24 (5): 661–700. Bibcode:2005MSRv...24..661S. doi:10.1002/mas.20033. ISSN   0277-7037. PMID   15495143.
  9. Johnsen, R.; Skrzypkowski, M.; Gougousi, T.; Rosati, R.; Golde, M. F. (2003). "Optical Spectroscopy of Recombining Ions in Flowing Afterglow Plasmas". Dissociative Recombination of Molecular Ions with Electrons. pp. 25–35. doi:10.1007/978-1-4615-0083-4_3. ISBN   978-1-4613-4915-0.
  10. Shun'Ko, E. V; Belkin, V. S (2012-06-01). "Treatment surfaces with atomic oxygen excited in dielectric barrier discharge plasma of O2 admixed to N2". AIP Advances. 2 (2): 022157. Bibcode:2012AIPA....2b2157S. doi: 10.1063/1.4732120 .
  11. Moisan, M; Barbeau, J; Moreau, S; Pelletier, J; Tabrizian, M; Yahia, L'H (2001-09-11). "Low-temperature sterilization using gas plasmas: a review of the experiments and an analysis of the inactivation mechanisms". International Journal of Pharmaceutics. 226 (1–2): 1–21. doi:10.1016/S0378-5173(01)00752-9. PMID   11532565.
  12. A. Pizzi; K. L. Mittal (2003). Handbook of Adhesive Technology, Revised and Expanded (2, illustrated, revised ed.). CRC Press. p. 1036. ISBN   978-0824709860.
  13. "Advances in Remote Plasma Sources For Cleaning 300 mm and Flat Panel CVD Systems". ResearchGate. Retrieved 2017-04-21.