Neural control of limb stiffness

Last updated

As humans move through their environment, they must change the stiffness of their joints in order to effectively interact with their surroundings. Stiffness is the degree to a which an object resists deformation when subjected to a known force. This idea is also referred to as impedance, however, sometimes the idea of deformation under a given load is discussed under the term "compliance" which is the opposite of stiffness (defined as the amount an object deforms under a certain known load). In order to effectively interact with their environment, humans must adjust the stiffness of their limbs. This is accomplished via the co-contraction of antagonistic muscle groups. [1] [2]

Contents

Humans use neural control along with the mechanical constraints of the body to adjust this stiffness as the body performs various tasks. It has been shown that humans change the stiffness of their limbs as they perform tasks such as hopping, [3] performing accurate reaching tasks, [4] or running on different surfaces. [5]

While the exact method by which this neural-modulation of limb stiffness occurs is unknown, many different hypotheses have been proposed. A thorough understanding of how and why the brain controls limb stiffness could lead to improvements in many robotic technologies that attempt to mimic human movement. [2]

Stiffness

Stiffness is typically viewed as a material property describing the amount a material deforms under a given force as described by Hooke's law. This means that objects with higher stiffness are more difficult to bend or deform than objects with lower stiffnesses. This concept can be extended to the limbs and joints of biological organisms in which stiffness describes the degree to which a limb or joint deflects (or bends) under a given load. Limb stiffness can also be described as the static component of impedance. [1] [6] Humans change the stiffness of their limbs and joints to adapt to their environment. [5] Limb and joint stiffness has been previously studied and can be quantified in various ways. The basic principle for calculating stiffness is dividing the deformation of a limb by the force applied to the limb, however, there are multiple methods of quantifying limb and joint stiffness with various pros and cons. When quantifying limb stiffness, one cannot simply sum the individual joint stiffnesses due to the nonlinearities of the multi-joint system.

A few of the specific methods for calculating limb stiffness can be seen below: [7]

Vertical Stiffness (kvert) is a quantitative measure of leg stiffness that can be defined by the equations below: [7]

Where Fmax is the maximum vertical force and delta y is the maximum vertical displacement of the center of mass

Where m is the body mass and P is the period of vertical vibration

Where m is the mass of the body mass and ω0 is the natural frequency of oscillation

Limb Stiffness (K_limb) is the stiffness of the entire limb and can be defined by the equations below:

Where Fmax is the maximum applied force and ΔL is the change in length of the limb

Torsional Stiffness (K_joint) is the rotational stiffness of the joint and can be defined by the equations below:

Where ΔM is the change in joint moment and Δθ is the change in joint angle

Where W is the negative mechanical work at the joint and Δθ is the change in joint angle

These different mathematical definitions of limb stiffness help to describe limb stiffness and show the methods by which such a limb characteristic can be quantified.

Stiffness modulation

The human body is able to modulate its limb stiffnesses through various mechanisms with the goal of more effectively interacting with its environment. The body varies the stiffness of its limbs by three primary mechanisms: muscle cocontraction, [1] [8] [9] posture selection, [6] and through stretch reflexes. [1] [10] [11] [12]

Muscle cocontraction (similar to muscle tone) is able to vary the stiffness of a joint by the action of antagonistic muscles acting on the joint. The stronger the forces of the antagonistic muscles on the joint are, the stiffer the joint becomes. [2] [8] The selection of body posture also affects the stiffness of the limb. By adjusting the orientation of the limb, the inherent stiffness of the limb can be manipulated. [6] Additionally, the stretch reflexes within a limb can affect the stiffness of the limb, however these commands are not sent from the brain. [10] [11]

Locomotion and hopping

As humans walk or run across different surfaces, they adjust the stiffness of their limbs to maintain similar locomotor mechanics independent of the surface. As the stiffness of a surface changes, humans adapt by changing their limb stiffness. This stiffness modulation allows for running and walking with similar mechanics regardless of the surface, therefore allowing humans to better interact and adapt with their environment. [3] [5] The modulation of stiffness therefore, has applications in the areas of motor control and other areas pertaining to the neural control of movement.

Studies also show that the variation of limb stiffness is important when hopping, and that different people may control this stiffness variation in different ways. One study showed that adults had more feedforward neural control, muscle reflexes, and higher relative leg stiffness than their juvenile counterparts when performing a hopping task. This indicates that the control of stiffness may vary from person to person. [3]

Movement accuracy

The nervous system also controls limb stiffness to modulate the degree of accuracy that is required for a given task. For example, the accuracy required to grab a cup off of a table is very different from that of a surgeon performing a precise task with a scalpel. To accomplish these tasks with varying degrees of required accuracy, the nervous system adjusts limb stiffness. [4] [6] To accomplish very accurate tasks higher stiffness is required, however, when performing tasks where accuracy is not as imperative, lower limb stiffness is needed. [4] [6] In the case of accurate movements, the central nervous system is able to precisely control limb stiffness to limit movement variability. The cerebellum also plays a large role in controlling for the accuracy of movements. [13]

This is an important concept for everyday tasks such as tool use. [6] [14] For example, when using a screwdriver, if limb stiffness is too low, the user will not have enough control over the screwdriver to drive a screw. Because of this, the central nervous system increases limb stiffness to allow the user to accurately maneuver the tool and perform a task.

Neural control

The exact mechanism for the neural control of stiffness is unknown, but progress has been made in the field with multiple proposed models of how stiffness modulation may be accomplished by the nervous system. Limb stiffness has multiple components that must be controlled to produce the appropriate limb stiffness.

Combination of mechanics and neural control

Both the neural control and the mechanics of the limb contribute to its overall stiffness. The cocontraction of antagonistic muscles, posture of the limb, and stretch reflexes within the limb all contribute to stiffness and are affected by the nervous system. [1] [6]

The stiffness of a limb is dependent on its configuration or joint arrangement. [1] [6] For example, an arm that is slightly bent, it will deform more easily under a force directed from the hand to the shoulder than an arm that is straight. In this way, the stiffness of a limb is partially dictated by the limb's posture. This component of limb stiffness is due to the mechanics of the limb and is controlled voluntarily.

Voluntary vs. involuntary stiffness modulation

Some components of limb stiffness are under voluntary control while others are involuntary. [6] The determining factor as to whether a component of stiffness is controlled voluntarily or involuntarily is the timescale of that particular component's method of action. For example, stiffness corrections that happen very quickly (80-100 milliseconds) are involuntary while slower stiffness corrections and adjustments are under voluntary control. Many of the voluntary stiffness adjustments are controlled by the motor cortex while involuntary adjustments can be controlled by reflex loops in the spinal cord or other parts of the brain. [8] [10] [13]

Stiffness adjustments due to reflexes are involuntary and are controlled by the spinal cord while posture selection is controlled voluntarily. [6] However, not each component of stiffness is strictly voluntary or involuntary. [8] For example, Antagonistic muscle cocontraction can be either voluntary or involuntary. Additionally, because much of the legs' movements are controlled by the spinal cord and because of the larger neural delay associated with sending signals to the leg muscles, leg stiffness is more involuntarily controlled than arm stiffness.

Possible neural control models

Researchers have begun implementing controllers in into robots to control for stiffness. One such model adjusts for stiffness during robotic locomotion by virtually cocontracting antagonistic muscles about the robot's joints to modulate stiffness while a central pattern generator (CPG) controls the robot's locomotion. [15]

Other models of the neural modulation of stiffness include a feedforward model of stiffness adjustment. These models of neural control support the idea that humans use a feedforward mechanism of stiffness selection in anticipation of the required stiffness needed to accomplish a given task. [16]

Most models of the neural control of stiffness promote the idea that humans choose an optimal limb stiffness based on their environment or the task at hand. Studies postulate the humans do this in order to stabilize unstable dynamics of the environment and also to maximize the energy efficiency of a given movement. [6] [14] The exact method by which humans accomplish this is unknown, but impedance control has been used to give insight into how humans may choose an appropriate stiffness in different environments and as they perform different tasks. [1] Impedance control has served as the basis for much of the work done in the area of determining how humans interact with their environment. The work of Neville Hogan has been particularly useful in this area as much of the work being done today in this area is based on his previous work. [1]

Applications in robotics

Neuroprosthetics and exoskeletons

A robotic leg powered by air muscle actuators 2005-11-14 ShadowLeg Finished medium.jpg
A robotic leg powered by air muscle actuators

Knowledge of human stiffness variation and stiffness selection has influenced robotic designs as researchers attempt to design robots that act more like biological systems. In order for robots to act more like biological systems, work is being done to attempt to implement stiffness modulation in robots so that they may interact more effectively with their environment.

State of the art neuroprosthetics have attempted to implements stiffness control in their robotic devices. The goal of these devices is to replace the limbs of amputees and allow the new limbs to adjust their stiffness in order to effectively interact with the environment. [17]

Additionally, robotic exoskeletons have attempted to implement similar adjustable stiffness in their devices. [18] These robots implement stiffness control for multiple reasons. The robots must be able to interact efficiently with the external environment but they must also be able to interact safely with their human user. [19] Stiffness modulation and impedance control can be leveraged to accomplish both of these goals.

These devices achieve variable stiffness in various ways. Some devices use controllers and rigid servomotors to simulate variable stiffness. Other devices utilize specific flexible actuators to achieve a various levels of limb stiffness.

Actuation Techniques

These robotic devices are able to achieve variable stiffness through various mechanisms such as simulating stiffness variation through control of stiff actuators or by utilizing variable stiffness actuators. Variable stiffness actuators mimic biological organisms by changing their inherent stiffness. [2] These variable stiffness actuators are able to control their inherent stiffness in multiple ways. Some vary their stiffness much like humans do, by varying the force contribution of antagonistic mechanical muscles. Other actuators are able to adjust their stiffness by taking advantage of the properties of deformable elements housed within the actuators.

By utilizing these variable stiffness actuation technologies, new robots have been able to more accurately replicate the motions of biological organisms and mimic their energetic efficiencies.

See also

Related Research Articles

<span class="mw-page-title-main">Tremor</span> Involuntary muscle contraction

A tremor is an involuntary, somewhat rhythmic, muscle contraction and relaxation involving oscillations or twitching movements of one or more body parts. It is the most common of all involuntary movements and can affect the hands, arms, eyes, face, head, vocal folds, trunk, and legs. Most tremors occur in the hands. In some people, a tremor is a symptom of another neurological disorder.

<span class="mw-page-title-main">Prosthesis</span> Artificial device that replaces a missing body part

In medicine, a prosthesis, or a prosthetic implant, is an artificial device that replaces a missing body part, which may be lost through trauma, disease, or a condition present at birth. Prostheses are intended to restore the normal functions of the missing body part. Amputee rehabilitation is primarily coordinated by a physiatrist as part of an inter-disciplinary team consisting of physiatrists, prosthetists, nurses, physical therapists, and occupational therapists. Prostheses can be created by hand or with computer-aided design (CAD), a software interface that helps creators design and analyze the creation with computer-generated 2-D and 3-D graphics as well as analysis and optimization tools.

In biology, a reflex, or reflex action, is an involuntary, unplanned sequence or action and nearly instantaneous response to a stimulus.

<span class="mw-page-title-main">Gait (human)</span> A pattern of limb movements made during locomotion

A gait is a manner of limb movements made during locomotion. Human gaits are the various ways in which humans can move, either naturally or as a result of specialized training. Human gait is defined as bipedal forward propulsion of the center of gravity of the human body, in which there are sinuous movements of different segments of the body with little energy spent. Varied gaits are characterized by differences such as limb movement patterns, overall velocity, forces, kinetic and potential energy cycles, and changes in contact with the ground.

Motor control is the regulation of movement in organisms that possess a nervous system. Motor control includes reflexes as well as directed movement.

In physiology, motor coordination is the orchestrated movement of multiple body parts as required to accomplish intended actions, like walking. This coordination is achieved by adjusting kinematic and kinetic parameters associated with each body part involved in the intended movement. The modifications of these parameters typically relies on sensory feedback from one or more sensory modalities, such as proprioception and vision.

<span class="mw-page-title-main">Muscle coactivation</span> Contraction to provide joint stability

Muscle coactivation occurs when agonist and antagonist muscles surrounding a joint contract simultaneously to provide joint stability, and is suggested to depend crucially on supraspinal processes involved in the control of movement. It is also known as muscle cocontraction, since two muscle groups are contracting at the same time. It is able to be measured using electromyography (EMG) from the contractions that occur. The general mechanism of it is still widely unknown. It is believed to be important in joint stabilization, as well as general motor control.

Preflexes are the latent capacities in the musculoskeletal system that auto-stabilize movements through the use of the nonlinear visco-elastic properties of muscles when they contract. The term "preflex" for such a zero-delay, intrinsic feedback loop was coined by Loeb. Unlike stabilization methods using neurons, such as reflexes and higher brain control, a preflex happens with minimal time delay; however, it only stabilizes the main movements of the musculoskeletal system.

<span class="mw-page-title-main">Robotics</span> Design, construction, use, and application of robots

Robotics is an interdisciplinary branch of Electronics & Communication, computer science and engineering. Robotics involves the design, construction, operation, and use of robots. The goal of robotics is to design machines that can help and assist humans. Robotics integrates fields of mechanical engineering, electrical engineering, information engineering, mechatronics engineering, electronics, biomedical engineering, computer engineering, control systems engineering, software engineering, mathematics, etc.

<span class="mw-page-title-main">Proprioception</span> Sense of self-movement, force, and body position

Proprioception, also called kinaesthesia, is the sense of self-movement, force, and body position.

<span class="mw-page-title-main">Spinal locomotion</span>

Spinal locomotion results from intricate dynamic interactions between a central program in lower thoracolumbar spine and proprioceptive feedback from body in the absence of central control by brain as in complete spinal cord injury (SCI). Following SCI, the spinal circuitry below the lesion site does not become silent rather it continues to maintain active and functional neuronal properties although in a modified manner.

Normal aging movement control in humans is about the changes in the muscles, motor neurons, nerves, sensory functions, gait, fatigue, visual and manual responses, in men and women as they get older but who do not have neurological, muscular or neuromuscular disorder. With aging, neuromuscular movements are impaired, though with training or practice, some aspects may be prevented.

In neuroscience and motor control, the degrees of freedom problem or motor equivalence problem states that there are multiple ways for humans or animals to perform a movement in order to achieve the same goal. In other words, under normal circumstances, no simple one-to-one correspondence exists between a motor problem and a motor solution to the problem. The motor equivalence problem was first formulated by the Russian neurophysiologist Nikolai Bernstein: "It is clear that the basic difficulties for co-ordination consist precisely in the extreme abundance of degrees of freedom, with which the [nervous] centre is not at first in a position to deal."

AnimatLab is an open-source neuromechanical simulation tool that allows authors to easily build and test biomechanical models and the neural networks that control them to produce behaviors. Users can construct neural models of varied level of detail, 3D mechanical models of triangle meshes, and use muscles, motors, receptive fields, stretch sensors, and other transducers to interface the two systems. Experiments can be run in which various stimuli are applied and data is recorded, making it a useful tool for computational neuroscience. The software can also be used to model biomimetic robotic systems.

Impedance control is an approach to dynamic control relating force and position. It is often used in applications where a manipulator interacts with its environment and the force position relation is of concern. Examples of such applications include humans interacting with robots, where the force produced by the human relates to how fast the robot should move/stop. Simpler control methods, such as position control or torque control, perform poorly when the manipulator experiences contacts. Thus impedance control is commonly used in these settings.

<span class="mw-page-title-main">Spinal interneuron</span> Interneuron relaying signals between sensory and motor neurons in the spinal cord

A spinal interneuron, found in the spinal cord, relays signals between (afferent) sensory neurons, and (efferent) motor neurons. Different classes of spinal interneurons are involved in the process of sensory-motor integration. Most interneurons are found in the grey column, a region of grey matter in the spinal cord.

<span class="mw-page-title-main">Proportional myoelectric control</span>

Proportional myoelectric control can be used to activate robotic lower limb exoskeletons. A proportional myoelectric control system utilizes a microcontroller or computer that inputs electromyography (EMG) signals from sensors on the leg muscle(s) and then activates the corresponding joint actuator(s) proportionally to the EMG signal.

Robotic prosthesis control is a method for controlling a prosthesis in such a way that the controlled robotic prosthesis restores a biologically accurate gait to a person with a loss of limb. This is a special branch of control that has an emphasis on the interaction between humans and robotics.

Postural control refers to the maintenance of body posture in space. The central nervous system interprets sensory input to produce motor output that maintains upright posture. Sensory information used for postural control largely comes from visual, proprioceptive, and vestibular systems. While the ability to regulate posture in vertebrates was previously thought to be a mostly automatic task, controlled by circuits in the spinal cord and brainstem, it is now clear that cortical areas are also involved, updating motor commands based on the state of the body and environment.

The term “soft robots” designs a broad class of robotic systems whose architecture includes soft elements, with much higher elasticity than traditional rigid robots. Articulated Soft Robots are robots with both soft and rigid parts, inspired to the muscloloskeletal system of vertebrate animals – from reptiles to birds to mammalians to humans. Compliance is typically concentrated in actuators, transmission and joints while structural stability is provided by rigid or semi-rigid links.

References

  1. 1 2 3 4 5 6 7 8 Hogan, Neville (1985). "The Mechanics of Multi-joint Posture and Movement Control". Biological Cybernetics. 52 (5): 315–331. doi:10.1007/bf00355754. PMID   4052499. S2CID   25966675.
  2. 1 2 3 4 Van Ham, R.; Sugar, T.G.; Vanderborght, B.; Hollander, K.W.; Lefeber, D. (2009). "Compliant Actuator Designs". IEEE Robotics & Automation Magazine. 16 (3): 81–94. doi:10.1109/mra.2009.933629. S2CID   50682770.
  3. 1 2 3 Oliver, J.L.; Smith, P.M. (2010). "Neural Control of Leg Stiffness During Hopping in Boys and Men". Journal of Electromyography and Kinesiology. 20 (5): 973–979. doi:10.1016/j.jelekin.2010.03.011. PMID   20409733.
  4. 1 2 3 Lametti, Daniel R.; Houle, Guillaume; Ostry, David J. (2007). "Control of Movement Variability and the Regulation of Limb Impedance". Journal of Neurophysiology. 98 (6): 3516–3524. doi:10.1152/jn.00970.2007. PMID   17913978.
  5. 1 2 3 Ferris, Daniel P.; Louie, Micky; Farley, Claire T. (1998). "Running in the Real World: Adjusting Leg Stiffness for Different Surfaces". Proceedings of the Royal Society B: Biological Sciences. 265 (1400): 989–994. doi:10.1098/rspb.1998.0388. PMC   1689165 . PMID   9675909.
  6. 1 2 3 4 5 6 7 8 9 10 11 Trumbower, Randy D; Krutky, M.A.; Yang, B.; Perreault, E.J. (2009). "Use of Self-Selected Postures to Regulate Multi-Joint Stiffness During Unconstrained Tasks". PLOS ONE. 4 (5): e5411. Bibcode:2009PLoSO...4.5411T. doi: 10.1371/journal.pone.0005411 . PMC   2671603 . PMID   19412540.
  7. 1 2 Butler, R.J.; Crowell, H.P.; Davis, I.M. (2003). "Lower Extremity Stiffness: Implications for Performance and Injury". Clinical Biomechanics. 18 (6): 511–517. doi:10.1016/s0268-0033(03)00071-8. PMID   12828900.
  8. 1 2 3 4 Ludvig, Daniel P; Kearney, R.E. (2007). "Real-time estimation of intrinsic and reflex stiffness". IEEE Transactions on Biomedical Engineering. 54 (10): 1875–1884. doi:10.1109/tbme.2007.894737. PMID   17926686. S2CID   17908248.
  9. Heitmann S, Ferns N, Breakspear M (2012). "Muscle co-contraction modulates damping and joint stability in a three-link biomechanical limb". Frontiers in Neurorobotics. 5 (5): 1. doi: 10.3389/fnbot.2011.00005 . PMC   3257849 . PMID   22275897.
  10. 1 2 3 Nichols, T.R; Houk, J.C. (1976). "Improvement in linearity and regulation of stiffness that results from actions of stretch reflex". J. Neurophysiol. 39 (1): 119–142. doi:10.1152/jn.1976.39.1.119. PMID   1249597.
  11. 1 2 Shemmell, Jonathan; Krutky, M.A.; Perreault, E.J. (2010). "Stretch sensitive reflexes as an adaptive mechanism for maintaining limb stability". Clinical Neurophysiology. 121 (10): 1680–1689. doi:10.1016/j.clinph.2010.02.166. PMC   2932821 . PMID   20434396.
  12. Trumbower, RD; Finley, J.M.; Shemmell, J.B.; Honeycutt, C.F.; Perreault, E.J. (2013). "Bilateral impairments in task-dependent modulation of the long-latency stretch reflex following stroke". Clinical Neurophysiology. 124 (7): 1373–1380. doi:10.1016/j.clinph.2013.01.013. PMC   3674210 . PMID   23453250.
  13. 1 2 Dale Purves; et al., eds. (2007). Neuroscience (4th ed.). New York: W. H. Freeman. ISBN   978-0878936977.
  14. 1 2 Burdet, E.; Osu, R.; Franklin, D.W.; Milner, T.E.; Kawato, M. (2001). "The central nervous system stabilizes unstable dynamics by learning optimal impedance". Nature. 414 (6862): 446–449. Bibcode:2001Natur.414..446B. doi:10.1038/35106566. PMID   11719805. S2CID   559162.
  15. Xiong, Xiaofeng; Worgotter, F.; Manoonpong, P. "An adaptive neuromechanical model for muscle impedance modulations of legged robots".{{cite journal}}: Cite journal requires |journal= (help)
  16. Hu, Xiao; Murray, W.M.; Perreault, E.J. (2012). "Biomechanical constraints on the feedforward regulation of endpoint stiffness". Journal of Neurophysiology. 108 (8): 2083–2091. doi:10.1152/jn.00330.2012. PMC   3545028 . PMID   22832565.
  17. Fite, Kevin; Mitchell, J.; Sup, F.; Goldfarb, M. (2007). "Design and control of an electrically powered knee prosthesis". Rehabilitation Robotics Conference.
  18. Van Der Kooij, H.; Veneman, J.; Ekkelenkamp, R. (2006). "Design of a compliantly actuated exo-skeleton for an impedance controlled gait trainer robot". 2006 International Conference of the IEEE Engineering in Medicine and Biology Society. Vol. 1. pp. 189–93. doi:10.1109/IEMBS.2006.259397. ISBN   978-1-4244-0032-4. PMID   17946801. S2CID   6555957.
  19. Kazerooni, Homayoon (1996). "The human power amplifier technology at University of California, Berkeley". Journal of Robotics and Autonomous Systems. 19 (2): 179–187. doi:10.1016/S0921-8890(96)00045-0. PMID   11540395.