Salt spray test

Last updated

The salt spray test (or salt fog test) is a standardized and popular corrosion test method, used to check corrosion resistance of materials and surface coatings. Usually, the materials to be tested are metallic (although stone, ceramics, and polymers may also be tested) and finished with a surface coating which is intended to provide a degree of corrosion protection to the underlying metal.

Contents

Salt spray testing is an accelerated corrosion test that produces a corrosive attack to coated samples in order to evaluate (mostly comparatively) the suitability of the coating for use as a protective finish. The appearance of corrosion products (rust or other oxides) is evaluated after a pre-determined period of time. Test duration depends on the corrosion resistance of the coating; generally, the more corrosion resistant the coating is, the longer the period of testing before the appearance of corrosion or rust.

The salt spray test is one of the most widespread and long-established corrosion tests. ASTM  B117 was the first internationally recognized salt spray standard, originally published in 1939. Other important relevant standards are ISO  9227, JIS  Z 2371 and ASTM  G85.

Application

Salt spray testing is popular because it is relatively inexpensive, quick, well standardized, and reasonably repeatable. Although there may be a weak correlation between the duration in salt spray test and the expected life of a coating in certain coatings such as hot-dip galvanized steel, this test has gained worldwide popularity due to low cost and quick results. Most Salt Spray Chambers today are being used NOT to predict the corrosion resistance of a coating, but to maintain coating processes such as pre-treatment and painting, electroplating, galvanizing, and the like, on a comparative basis. For example, pre-treated + painted components must pass 96 hours Neutral Salt Spray, to be accepted for production. Failure to meet this requirement implies instability in the chemical process of the pre-treatment, or the paint quality, which must be addressed immediately so that the upcoming batches are of the desired quality. The longer the accelerated corrosion test, the longer the process remains out of control, and larger is the loss in the form of non-conforming batches. The principal application of the salt spray test is, therefore, enabling quick comparisons to be made between actual and expected corrosion resistance. Most commonly, the time taken for oxides to appear on the samples under test is compared to expectations, to determine whether the test is passed or failed. For this reason, the salt spray test is most often deployed in a quality audit role, where, for example, it can be used to check the effectiveness of a production process, such as the surface coating of a metallic part. The salt spray test has little application in predicting how materials or surface coatings will resist corrosion in the real world, because it does not create, replicate or accelerate real-world corrosive conditions. Cyclic corrosion testing is better suited to this.

Testing equipment

A salt spray cabinet SS cabinet.jpg
A salt spray cabinet

The apparatus for testing consists of a closed testing cabinet/chamber, where a salt water (5% NaCl) solution is atomized by means of spray nozzle(s) using pressurized air. This produces a corrosive environment of dense salt water fog (also referred to as a mist or spray) in the chamber, so that test samples exposed to this environment are subjected to severely corrosive conditions. Chamber volumes vary from supplier to supplier. If there is a minimum volume required by a particular salt spray test standard, this will be clearly stated and should be complied with. There is a general historical consensus that larger chambers can provide a more homogeneous testing environment.

Variations to the salt spray test solutions depend upon the materials to be tested. The most common test for steel based materials is the Neutral Salt Spray test (often abbreviated to NSS) which reflects the fact that this type of test solution is prepared to a neutral pH of 6.5 to 7.2. To maintain a neutral pH, hydrochloric acid or sodium hydroxide are added to reduce or increase pH into the required range. Results are represented generally as testing hours in NSS without appearance of corrosion products (e.g. 720 h in NSS according to ISO 9227). Synthetic seawater solutions are also commonly specified by some companies and standards. Other test solutions have other chemicals added including acetic acid (often abbreviated to ASS) and acetic acid with copper chloride (often abbreviated to CASS) each one chosen for the evaluation of decorative coatings, such as electroplated copper-nickel-chromium, electroplated copper-nickel or anodized aluminum. These acidified test solutions generally have a pH of 3.1 to 3.3

Some sources do not recommend using ASS or CASS test cabinets interchangeably for NSS tests, due to the risk of cross-contamination. It is claimed that a thorough cleaning of the cabinet after CASS test is very difficult. ASTM does not address this issue, but ISO 9227 does not recommend it and if it is to be done, advocates a thorough cleaning.

Although the majority of salt spray tests are continuous, i.e.; the samples under test are exposed to the continuous generation of salt fog for the entire duration of the test, a few do not require such exposure. Such tests are commonly referred to as modified salt spray tests. ASTM G85 is an example of a test standard which contains several modified salt spray tests which are variations to the basic salt spray test.

Modified salt spray tests

ASTM G85 [1] is the most popular global test standard covering modified salt spray tests. There are five such tests altogether, referred to in ASTM G85 as annexes A1 through to A5.

A modified salt spray chamber in use Salt Spray Chamber.jpg
A modified salt spray chamber in use

Many of these modified tests originally arose within particular industry sector, in order to address the need for a corrosion test capable of replicating the effects of naturally occurring corrosion and accelerate these effects.

This acceleration arises through the use of chemically altered salt spray solutions, often combined with other test climates and in most cases, the relatively rapid cycling of these test climates over time. Although popular in certain industries, modified salt spray testing has in many cases been superseded by cyclic corrosion testing (CCT) The type of environmental test chambers used for modified salt spray testing to ASTM G85 are generally similar to the chambers used for testing to ASTM B117, but will often have some additional features, such as an automatic climate cycling control system.

Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 1 ASTM G85 Annex 1.jpg
Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 1

ASTM G85 Annex A1 – Acetic Acid Salt Spray Test (non-cyclic) This test can be used to determine the relative resistance to corrosion of decorative chromium plating on steel and zinc based die casting when exposed to an acetic acid salt spray climate at an elevated temperature. This test is also referred to as an ASS test. Test specimens are placed in an enclosed chamber and exposed to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified (pH 3.1–3.3) by the addition of acetic acid. This spray is set to fall-out on to the specimens at a rate of 1–2 ml/80 cm2/hour, in a chamber temperature of 35 °C. This climate is maintained under constant steady state conditions. The test duration is variable. [2]

Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 2 ASTM G85 Annex 2.jpg
Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 2

ASTM G85 Annex A2 – Acidified Salt Fog Test (cyclic).

This test can be used to test the relative resistance to corrosion of aluminium alloys when exposed to a changing climate of acetic acid salt spray, followed by air drying, followed by high humidity, all at an elevated temperature. This test is also referred to as a MASTMAASIS test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 3 part repeating cycle. 0.75 hours exposure to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified (pH 2.8–3.0) by the addition of acetic acid. This spray is set to fall-out on to the specimens at a rate of 1–2 ml/80 cm2/hour. This is followed by a 2 hour exposure to an air drying (purge) climate. This is followed by 3.25 hours exposure to a high humidity climate which gradually rises to between 65% RH and 95% RH. The entire test cycle is at a constant chamber temperature of 49 °C. The number of cycle repeats and therefore the test duration is variable. [2]

Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 3 ASTM G85 Annex 3.jpg
Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 3

ASTM G85 Annex A3 – Seawater Acidified Test (cyclic)

This test can be used to test the relative resistance to corrosion of coated or uncoated aluminium alloys and other metals, when exposed to a changing climate of acidified synthetic seawater spray, followed by a high humidity, both at an elevated temperature. This test is also referred to as a SWAAT test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate that comprises the following 2 part repeating cycle. First, a 30 minute exposure to a continuous indirect spray of synthetic seawater solution, prepared in accordance with the requirements of the test standard and acidified (pH 2.8–3.0) by the addition of acetic acid. This spray is set to fall-out on to the specimens at a rate of 1–2 ml/80 cm2/hour. This is followed by a 90 minute exposure to a high humidity climate (above 98% RH). The entire test cycle is at a constant chamber temperature of 49 °C (may be reduced to 24–35 °C for organically coated specimens). The number of cycle repeats and therefore the test duration is variable. [2]

Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 4A ASTM G85 Annex 4A.jpg
Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 4A
An example of modified salt spray test ASTM G85 annex A4 - SO2 Salt Spray Test Illustration of a chamber undergoing Modified Salt Spray Test ASTM G85 Annex A4.jpg
An example of modified salt spray test ASTM G85 annex A4 – SO2 Salt Spray Test

ASTM G85 Annex A4 – SO
2
Salt Spray Test (cyclic)

This test can be used to test the relative resistance to corrosion of product samples that are likely to encounter a combined SO
2
/salt spray/acid rain environment during their usual service life. Test specimens are placed in an enclosed chamber, and exposed to 1 of 2 possible changing climate cycles. In either case, the exposure to salt spray may be salt water spray or synthetic sea water prepared in accordance with the requirements of the test standard. The most appropriate test cycle and spray solutions are to be agreed between parties.

The first climate cycle comprises a continuous indirect spray of neutral (pH 6.5–7.2) salt water/synthetic seawater solution, which falls-out on to the specimens at a rate of 1–2 ml/80 cm2/hour. During this spraying, the chamber is dosed with SO
2
gas at a rate of 35 cm3/minute/m3 of chamber volume, for 1 hour in every 6 hours of spraying. The entire test cycle is at a constant chamber temperature of 35 °C. The number of cycle repeats and therefore the test duration is variable.

The second climate cycle comprises 0.5 hours of continuous indirect spray of neutral (pH 6.5–7.2) salt water/synthetic seawater solution, which falls-out on to the specimens at a rate of 1–2 ml/80 cm2/hour. This is followed by 0.5 hours of dosing with SO
2
gas at a rate of 35 cm3/minute/m3 of chamber volume. This is followed by 2 hours of high humidity soak. The entire test cycle is at a constant chamber temperature of 35 °C. The number of cycle repeats and therefore the test duration is variable. [2]

Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 5 ASTM G85 Annex 5.jpg
Graph showing the temperature & humidity steps required during modified Salt Spray Test ASTM G85 Annex 5

ASTM G85 Annex A5 – Dilute Electrolyte Salt Fog/Dry Test (cyclic)

This test can be used to test the relative resistance to corrosion of paints on steel when exposed to a changing climate of dilute salt spray at ambient temperature, followed by air drying at elevated temperature. It is a popular test in the surface coatings industry, where it is also referred to as the PROHESION test. Test specimens are placed in an enclosed chamber, and exposed to a changing climate with the following 2-part cycle. First, a 1-hour exposure to a continuous indirect spray of salt water solution, prepared in accordance with the requirements of the test standard and acidified (pH 3.1–3.3) by the addition of acetic acid. This spray is set to fall on the specimens at a rate of 1–2 ml/80 cm2/hour, in an ambient chamber temperature (21–27 °C). This is followed by a 1-hour exposure to an air drying (purge) climate at 35 °C. The cycle repeats until the desired duration has been achieved. [2]

Standardization

Electroplated and yellow chromated bolt with white corrosion Whiterust.jpg
Electroplated and yellow chromated bolt with white corrosion
Zinc flake coated bolt with red rust after testing Redrust.jpg
Zinc flake coated bolt with red rust after testing

Chamber construction, testing procedure and testing parameters are standardized under national and international standards, such as ASTM B 117 and ISO 9227. These standards describe the necessary information to carry out this test; testing parameters such as temperature, air pressure of the sprayed solution, preparation of the spraying solution, concentration, pH, etc. Daily checking of testing parameters is necessary to show compliance with the standards, so records shall be maintained accordingly. ASTM B117 and ISO 9227 are widely used as reference standards. Testing cabinets are manufactured according to the specified requirements here.

However, these testing standards neither provide information of testing periods for the coatings to be evaluated, nor the appearance of corrosion products in form of salts. Requirements are agreed between customer and manufacturer. In the automotive industry requirements are specified under material specifications. Different coatings have different behavior in salt spray test and consequently, test duration will differ from one type of coating to another. For example, a typical electroplated zinc and yellow passivated steel part lasts 96 hours in salt spray test without white rust. Electroplated zinc-nickel steel parts can last more than 720 hours in NSS test without red rust (or 48 hours in CASS test without red rust) Requirements are established in test duration (hours) and coatings shall comply with minimum testing periods.

Artificial seawater which is sometimes used for Salt Spray Testing can be found at ASTM International. The standard for Artificial Seawater is ASTM D1141-98 which is the standard practice for the preparation of substitute ocean water.

Uses

Typical coatings that can be evaluated with this method are:

Hot-dip galvanized surfaces are not generally tested in a salt spray test (see ISO 1461 or ISO 10684). Hot-dip galvanizing produces zinc carbonates when exposed to a natural environment, thus protecting the coating metal and reducing the corrosion rate. The zinc carbonates are not produced when a hot-dip galvanized specimen is exposed to a salt spray fog, therefore this testing method does not give an accurate measurement of corrosion protection. ISO 9223 gives the guidelines for proper measurement of corrosion resistance for hot-dip galvanized specimens.

Painted surfaces with an underlying hot-dip galvanized coating can be tested according to this method. See ISO 12944-6.

Testing periods range from a few hours (e.g. 8 or 24 hours of phosphated steel) to more than a month (e.g. 720 hours of zinc-nickel coatings, 1000 hours of certain zinc flake coatings).

Bibliography

See also

Further reading

Related Research Articles

<span class="mw-page-title-main">Rust</span> Type of iron oxide

Rust is an iron oxide, a usually reddish-brown oxide formed by the reaction of iron and oxygen in the catalytic presence of water or air moisture. Rust consists of hydrous iron(III) oxides (Fe2O3·nH2O) and iron(III) oxide-hydroxide (FeO(OH), Fe(OH)3), and is typically associated with the corrosion of refined iron.

<span class="mw-page-title-main">Electroplating</span> Creation of protective or decorative metallic coating on other metal with electric current

Electroplating, also known as electrochemical deposition or electrodeposition, is a process for producing a metal coating on a solid substrate through the reduction of cations of that metal by means of a direct electric current. The part to be coated acts as the cathode of an electrolytic cell; the electrolyte is a solution of a salt of the metal to be coated; and the anode is usually either a block of that metal, or of some inert conductive material. The current is provided by an external power supply.

<span class="mw-page-title-main">Corrosion</span> Gradual destruction of materials by chemical reaction with its environment

Corrosion is a natural process that converts a refined metal into a more chemically stable oxide. It is the gradual deterioration of materials by chemical or electrochemical reaction with their environment. Corrosion engineering is the field dedicated to controlling and preventing corrosion.

<span class="mw-page-title-main">Hot-dip galvanization</span> Process of coating iron or steel with molten zinc

Hot-dip galvanization is a form of galvanization. It is the process of coating iron and steel with zinc, which alloys with the surface of the base metal when immersing the metal in a bath of molten zinc at a temperature of around 450 °C (842 °F). When exposed to the atmosphere, the pure zinc (Zn) reacts with oxygen (O2) to form zinc oxide (ZnO), which further reacts with carbon dioxide (CO2) to form zinc carbonate (ZnCO3), a usually dull grey, fairly strong material that protects the steel underneath from further corrosion in many circumstances. Galvanized steel is widely used in applications where corrosion resistance is needed without the cost of stainless steel, and is considered superior in terms of cost and life-cycle. It can be identified by the crystallization patterning on the surface (often called a "spangle").

<span class="mw-page-title-main">Cathodic protection</span> Corrosion prevention technique

Cathodic protection is a technique used to control the corrosion of a metal surface by making it the cathode of an electrochemical cell. A simple method of protection connects the metal to be protected to a more easily corroded "sacrificial metal" to act as the anode. The sacrificial metal then corrodes instead of the protected metal. For structures such as long pipelines, where passive galvanic cathodic protection is not adequate, an external DC electrical power source is used to provide sufficient current.

<span class="mw-page-title-main">Chrome plating</span> Technique of electroplating

Chrome plating is a technique of electroplating a thin layer of chromium onto a metal object. A chrome plated part is called chrome, or is said to have been chromed. The chromium layer can be decorative, provide corrosion resistance, facilitate cleaning, or increase surface hardness. Sometimes, a less expensive substitute for chrome such as nickel may be used for aesthetic purposes.

Electropolishing, also known as electrochemical polishing, anodic polishing, or electrolytic polishing, is an electrochemical process that removes material from a metallic workpiece, reducing the surface roughness by levelling micro-peaks and valleys, improving the surface finish. Electropolishing is often compared to, but distinctly different from, electrochemical machining. It is used to polish, passivate, and deburr metal parts. It is often described as the reverse of electroplating. It may be used in lieu of abrasive fine polishing in microstructural preparation.

<span class="mw-page-title-main">Anodizing</span> Metal treatment process

Anodizing is an electrolytic passivation process used to increase the thickness of the natural oxide layer on the surface of metal parts.

<span class="mw-page-title-main">Hydrogen embrittlement</span> Reduction in ductility of a metal exposed to hydrogen

Hydrogen embrittlement (HE), also known as hydrogen-assisted cracking or hydrogen-induced cracking (HIC), is a reduction in the ductility of a metal due to absorbed hydrogen. Hydrogen atoms are small and can permeate solid metals. Once absorbed, hydrogen lowers the stress required for cracks in the metal to initiate and propagate, resulting in embrittlement. Hydrogen embrittlement occurs most notably in steels, as well as in iron, nickel, titanium, cobalt, and their alloys. Copper, aluminium, and stainless steels are less susceptible to hydrogen embrittlement.

Plating is a surface covering in which a metal is deposited on a conductive surface. Plating has been done for hundreds of years; it is also critical for modern technology. Plating is used to decorate objects, for corrosion inhibition, to improve solderability, to harden, to improve wearability, to reduce friction, to improve paint adhesion, to alter conductivity, to improve IR reflectivity, for radiation shielding, and for other purposes. Jewelry typically uses plating to give a silver or gold finish.

<span class="mw-page-title-main">Metallizing</span>

Metallizing is the general name for the technique of coating metal on the surface of objects. Metallic coatings may be decorative, protective or functional.

<span class="mw-page-title-main">Chromate conversion coating</span> Chemical treatment of metals

Chromate conversion coating or alodine coating is a type of conversion coating used to passivate steel, aluminium, zinc, cadmium, copper, silver, titanium, magnesium, and tin alloys. The coating serves as a corrosion inhibitor, as a primer to improve the adherence of paints and adhesives, as a decorative finish, or to preserve electrical conductivity. It also provides some resistance to abrasion and light chemical attack on soft metals.

<span class="mw-page-title-main">Electroless nickel-phosphorus plating</span>

Electroless nickel-phosphorus plating, also referred to as E-nickel, is a chemical process that deposits an even layer of nickel-phosphorus alloy on the surface of a solid substrate, like metal or plastic. The process involves dipping the substrate in a water solution containing nickel salt and a phosphorus-containing reducing agent, usually a hypophosphite salt. It is the most common version of electroless nickel plating and is often referred by that name. A similar process uses a borohydride reducing agent, yielding a nickel-boron coating instead.

Electrogalvanizing is a process in which a layer of zinc is bonded to steel in order to protect against corrosion. The process involves electroplating, running a current of electricity through a saline/zinc solution with a zinc anode and steel conductor. Such Zinc electroplating or Zinc alloy electroplating maintains a dominant position among other electroplating process options, based upon electroplated tonnage per annum. According to the International Zinc Association, more than 5 million tons are used yearly for both hot dip galvanizing and electroplating. The plating of zinc was developed at the beginning of the 20th century. At that time, the electrolyte was cyanide based. A significant innovation occurred in the 1960s, with the introduction of the first acid chloride based electrolyte. The 1980s saw a return to alkaline electrolytes, only this time, without the use of cyanide. The most commonly used electrogalvanized cold rolled steel is SECC, acronym of "Steel, Electrogalvanized, Cold-rolled, Commercial quality". Compared to hot dip galvanizing, electroplated zinc offers these significant advantages:

<span class="mw-page-title-main">Bresle method</span>

The Bresle method is used to determine concentration of soluble salts on metal surfaces prior to coating application, such as painting. These salts can cause serious adhesion problems after time.

<span class="mw-page-title-main">Environmental chamber</span>

An environmental chamber, also called a climatic chamber or climate chamber, is an enclosure used to test the effects of specified environmental conditions on biological items, industrial products, materials, and electronic devices and components.

Zinc flake coatings are non-electrolytically applied coatings, which provide good protection against corrosion. These coatings consist of a mixture of zinc and aluminium flakes, which are bonded together by an inorganic matrix.

<span class="mw-page-title-main">Cyclic corrosion testing</span>

Cyclic Corrosion Testing (CCT) has evolved in recent years, largely within the automotive industry, as a way of accelerating real-world corrosion failures, under laboratory controlled conditions. As the name implies, the test comprises different climates which are cycled automatically so the samples under test undergo the same sort of changing environment that would be encountered in the natural world. The intention being to bring about the type of failure that might occur naturally, but more quickly i.e. accelerated. By doing this manufacturers and suppliers can predict, more accurately, the service life expectancy of their products.

<span class="mw-page-title-main">Flowers of sulfur tests</span>

Flowers of sulfur (FOS) testing was developed to determine the porosity of metallic coatings susceptible to sulfur induced corrosion [see below ASTM B809-95(2018)]. Applicable substrates are silver, copper, copper alloys and any other metal or metal alloy with which sulfur will react. For porosity testing, coatings can be single or multiple layers of any metal that is not corroded and sealed by a self-limiting reaction in the reducing sulfur environment of the FOS test. The simplest recommended technique is to identify any porosity of the coating as revealed by the presence of surface spots. These surface spots form where the environmental sulfur has penetrated and reacted with the base metal, producing a metal sulfide. Chalcocite, copper (I) sulfide is dark-grey to black. Silver (I) sulfide is also grey-black.

<span class="mw-page-title-main">Kesternich test</span>

The Kesternich test is a common name for the corrosion test with sulfur dioxide (SO2) under general moisture condensation. This test was developed in 1951 by Wilhelm Kesternich to simulate the damaging effects of acid rain. Acid rain and acidic industrial pollutants are corrosive and can degrade coatings and plated surfaces. Kesternich testing, or sulfur dioxide testing, simulates acid rain or industrial chemical exposure to evaluate the relative corrosion resistance of the coating, substrate, or part itself. The test can be used for coatings or for base materials. The test method is defined by various standards, DIN EN ISO 6988, DIN 50018, ASTM G87, ISO 3231, ISO 22479 are the most common. The parts to be tested are placed in a test chamber with a capacity of 300L and exposed to warm, moist air in combination with a certain amount of sulfur dioxide

References

  1. Information on ASTM G85 methods
  2. 1 2 3 4 5 al., Robert Baboian, editor ; section editors, Robert Baboian ... et (2004). Corrosion tests and standards : application and interpretation (2nd ed.). West Conshohocken, PA: ASTM International. pp. 132–134. ISBN   0803120982.{{cite book}}: |first1= has generic name (help)
  3. ASTM G85 Standard
  4. ASTM B117 Test Conditions