Second-harmonic imaging microscopy

Last updated

Second-harmonic imaging microscopy (SHIM) is based on a nonlinear [ disambiguation needed ] optical effect known as second-harmonic generation (SHG). SHIM has been established as a viable microscope imaging contrast mechanism for visualization of cell and tissue structure and function. [1] A second-harmonic microscope obtains contrasts from variations in a specimen's ability to generate second-harmonic light from the incident light while a conventional optical microscope obtains its contrast by detecting variations in optical density, path length, or refractive index of the specimen. SHG requires intense laser light passing through a material with a noncentrosymmetric molecular structure, either inherent or induced externally, for example by an electric field. [2]

Contents

Second-harmonic light emerging from an SHG material is exactly half the wavelength (frequency doubled) of the light entering the material. While two-photon-excited fluorescence (TPEF) is also a two photon process, TPEF loses some energy during the relaxation of the excited state, while SHG is energy conserving. Typically, an inorganic crystal is used to produce SHG light such as lithium niobate (LiNbO3), potassium titanyl phosphate (KTP = KTiOPO4), and lithium triborate (LBO = LiB3O5). Though SHG requires a material to have specific molecular orientation in order for the incident light to be frequency doubled, some biological materials can be highly polarizable, and assemble into fairly ordered, large noncentrosymmetric structures. While some biological materials such as collagen, microtubules, and muscle myosin [3] can produce SHG signals, even water can become ordered and produce second-harmonic signal under certain conditions, which allows SH microscopy to image surface potentials without any labeling molecules. [2] The SHG pattern is mainly determined by the phase matching condition. A common setup for an SHG imaging system will have a laser scanning microscope with a titanium sapphire mode-locked laser as the excitation source. The SHG signal is propagated in the forward direction. However, some experiments have shown that objects on the order of about a tenth of the wavelength of the SHG produced signal will produce nearly equal forward and backward signals.

Second-harmonic image of collagen (shown in white) in liver SHG collagen in liver.jpg
Second-harmonic image of collagen (shown in white) in liver

Advantages

SHIM offers several advantages for live cell and tissue imaging. SHG does not involve the excitation of molecules like other techniques such as fluorescence microscopy therefore, the molecules shouldn't suffer the effects of phototoxicity or photobleaching. Also, since many biological structures produce strong SHG signals, the labeling of molecules with exogenous probes is not required which can also alter the way a biological system functions. By using near infrared wavelengths for the incident light, SHIM has the ability to construct three-dimensional images of specimens by imaging deeper into thick tissues.

Difference and complementarity with two-photon fluorescence (2PEF)

Two-photons fluorescence (2PEF) is a very different process from SHG: it involves excitation of electrons to higher energy levels, and subsequent de-excitation by photon emission (unlike SHG, although it is also a 2-photon process). Thus, 2PEF is a non coherent process, spatially (emitted isotropically) and temporally (broad, sample-dependent spectrum). It is also not specific to certain structure, unlike SHG. [4]

It can therefore be coupled to SHG in multiphoton imaging to reveal some molecules that do produce autofluorescence, like elastin in tissues (while SHG reveals collagen or myosin for instance). [4]

History

Before SHG was used for imaging, the first demonstration of SHG was performed in 1961 by P. A. Franken, G. Weinreich, C. W. Peters, and A. E. Hill at the University of Michigan, Ann Arbor using a quartz sample. [5] In 1968, SHG from interfaces was discovered by Bloembergen [6] and has since been used as a tool for characterizing surfaces and probing interface dynamics. In 1971, Fine and Hansen reported the first observation of SHG from biological tissue samples. [7] In 1974, Hellwarth and Christensen first reported the integration of SHG and microscopy by imaging SHG signals from polycrystalline ZnSe. [8] In 1977, Colin Sheppard imaged various SHG crystals with a scanning optical microscope. The first biological imaging experiments were done by Freund and Deutsch in 1986 to study the orientation of collagen fibers in rat tail tendon. [9] In 1993, Lewis examined the second-harmonic response of styryl dyes in electric fields. He also showed work on imaging live cells. In 2006, Goro Mizutani group developed a non-scanning SHG microscope that significantly shortens the time required for observation of large samples, even if the two-photons wide-field microscope was published in 1996 [10] and could have been used to detect SHG. The non-scanning SHG microscope was used for observation of plant starch, [11] [12] megamolecule, [13] spider silk [14] [15] and so on. In 2010 SHG was extended to whole-animal in vivo imaging. [16] [17] In 2019, SHG applications widened when it was applied to the use of selectively imaging agrochemicals directly on leaf surfaces to provide a way to evaluate the effectiveness of pesticides. [18]

Quantitative measurements

Orientational anisotropy

SHG polarization anisotropy can be used to determine the orientation and degree of organization of proteins in tissues since SHG signals have well-defined polarizations. By using the anisotropy equation: [19]

and acquiring the intensities of the polarizations in the parallel and perpendicular directions. A high value indicates an anisotropic orientation whereas a low value indicates an isotropic structure. In work done by Campagnola and Loew, [19] it was found that collagen fibers formed well-aligned structures with an value.

Forward over backward SHG

SHG being a coherent process (spatially and temporally), it keeps information on the direction of the excitation and is not emitted isotropically. It is mainly emitted in forward direction (same as excitation), but can also be emitted in backward direction depending on the phase-matching condition. Indeed, the coherence length beyond which the conversion of the signal decreases is:

with for forward, but for backward such that >> . Therefore, thicker structures will appear preferentially in forward, and thinner ones in backward: since the SHG conversion depends at first approximation on the square of the number of nonlinear converters, the signal will be higher if emitted by thick structures, thus the signal in forward direction will be higher than in backward. However, the tissue can scatter the generated light, and a part of the SHG in forward can be retro-reflected in the backward direction. [20] Then, the forward-over-backward ratio F/B can be calculated, [20] and is a metric of the global size and arrangement of the SHG converters (usually collagen fibrils). It can also be shown that the higher the out-of-plane angle of the scatterer, the higher its F/B ratio (see fig. 2.14 of [21] ).

Polarization-resolved SHG

The advantages of polarimetry were coupled to SHG in 2002 by Stoller et al. [22] Polarimetry can measure the orientation and order at molecular level, and coupled to SHG it can do so with the specificity to certain structures like collagen: polarization-resolved SHG microscopy (p-SHG) is thus an expansion of SHG microscopy. [23] p-SHG defines another anisotropy parameter, as: [24]

which is, like r, a measure of the principal orientation and disorder of the structure being imaged. Since it is often performed in long cylindrical filaments (like collagen), this anisotropy is often equal to , [25] where is the nonlinear susceptibility tensor and X the direction of the filament (or main direction of the structure), Y orthogonal to X and Z the propagation of the excitation light. The orientation ϕ of the filaments in the plane XY of the image can also be extracted from p-SHG by FFT analysis, and put in a map. [25] [26]

Fibrosis quantization

Collagen (particular case, but widely studied in SHG microscopy), can exist in various forms : 28 different types, of which 5 are fibrillar. One of the challenge is to determine and quantify the amount of fibrillar collagen in a tissue, to be able to see its evolution and relationship with other non-collagenous materials. [27]

To that end, a SHG microscopy image has to be corrected to remove the small amount of residual fluorescence or noise that exist at the SHG wavelength. After that, a mask can be applied to quantify the collagen inside the image. [27] Among other quantization techniques, it is probably the one with the highest specificity, reproductibility and applicability despite being quite complex. [27]

Others

It has also been used to prove that backpropagating action potentials invade dendritic spines without voltage attenuation, establishing a sound basis for future work on Long-term potentiation. Its use here was that it provided a way to accurately measure the voltage in the tiny dendritic spines with an accuracy unattainable with standard two-photon microscopy. [28] Meanwhile, SHG can efficiently convert near-infrared light to visible light to enable imaging-guided photodynamic therapy, overcoming the penetration depth limitations. [29]

Materials that can be imaged

Biological tissues imaged by second-harmonic generation (SHG) microscopy. (a) Transverse cut of a human cornea. (b) Skeletal muscle from zebrafish (myosin). (c) Adult mice-tail tendon. (d) Surface cartilage from a knee of a mature horse. Cornea muscle-ad tendon mice cart-horse-surf.png
Biological tissues imaged by second-harmonic generation (SHG) microscopy. (a) Transverse cut of a human cornea. (b) Skeletal muscle from zebrafish (myosin). (c) Adult mice-tail tendon. (d) Surface cartilage from a knee of a mature horse.

SHG microscopy and its expansions can be used to study various tissues: some example images are reported in the figure below: collagen inside the extracellular matrix remains the main application. It can be found in tendon, skin, bone, cornea, aorta, fascia, cartilage, meniscus, intervertebral disks...

Myosin can also be imaged in skeletal muscle or cardiac muscle.

Table 1: Materials visible by or that efficiently generate SHG.
TypeMaterialFound inSHG signalSpecificity
Carbohydrate Cellulose Wood, green plant, algae.Quite weak in normal cellulose, [18] but substantial in crystalline or nanocrystalline cellulose.-
Starch Staple foods, green plant Quite intense signal [30] chirality is at micro and macro level, and the SHG is different under right or left-handed circular polarization
Megamolecular polysaccharide sacran Cyanobactery From sacran cotton-like lump, fibers, and cast filmssignal from films is weaker [13]
Protein Fibroin and sericin Spider silkQuite weak [14]
Collagen [9] tendon, skin, bone, cornea, aorta, fascia, cartilage, meniscus, intervertebral disks  ; connective tissuesQuite strong, depends on the type of the collagen (does it form fibrils, fibers ?) nonlinear susceptibility tensor components are , , , with ~ and / ~ 1.4 in most cases
Myosin Skeletal or cardiac muscle [3] Quite strong nonlinear susceptibility tensor components are , , with ~ but / ~ 0.6 < 1 contrary to collagen
Tubulin Microtubules in mitosis or meiosis, [31] or in neurites (mainly axons) [32] Quite weakThe microtubules have to be aligned to efficiently generate
Minerals Piezoelectric crystalsAlso called nonlinear crystals Strong if phase-matched Different types of phase-matching, critical of non-critical
Polar liquids Water Most living organismsBarely detectable (requires wide-field geometry and ultra-short laser pulses [33] )Directly probing electrostatic fields, since oriented water molecules satisfy phase-matching condition [34]

Coupling with THG microscopy

Third-Harmonic Generation (THG) microscopy can be complementary to SHG microscopy, as it is sensitive to the transverse interfaces, and to the 3rd order nonlinear susceptibility [35]  · [36]

Applications

Cancer progression, tumor characterization

The mammographic density is correlated with the collagen density, thus SHG can be used for identifying breast cancer. [37] SHG is usually coupled to other nonlinear techniques such as Coherent anti-Stokes Raman Scattering or Two-photon excitation microscopy, as part of a routine called multiphoton microscopy (or tomography) that provides a non-invasive and rapid in vivo histology of biopsies that may be cancerous. [38]

Breast cancer

The comparison of forward and backward SHG images gives insight about the microstructure of collagen, itself related to the grade and stage of a tumor, and its progression in breast. [39] Comparison of SHG and 2PEF can also show the change of collagen orientation in tumors. [40] Even if SHG microscopy has contributed a lot to breast cancer research, it is not yet established as a reliable technique in hospitals, or for diagnostic of this pathology in general. [39]

Ovarian cancer

Healthy ovaries present in SHG a uniform epithelial layer and well-organized collagen in their stroma, whereas abnormal ones show an epithelium with large cells and a changed collagen structure. [39] The r ratio (see #Orientational anisotropy) is also used [41] to show that the alignment of fibrils is slightly higher for cancerous than for normal tissues.

Skin cancer

SHG is, again, combined to 2PEF is used to calculate the ratio:

where shg (resp. tpef) is the number of thresholded pixels in the SHG (resp. 2PEF) image, [42] a high MFSI meaning a pure SHG image (with no fluorescence). The highest MFSI is found in cancerous tissues, [39] which provides a contrast mode to differentiate from normal tissues.

SHG was also combined to Third-Harmonic Generation (THG) to show that backward (see #Forward over backward SHG) THG is higher in tumors. [43]

Pancreatic cancer

Changes in collagen ultrastructure in pancreatic cancer can be investigated by multiphoton fluorescence and polarization-resolved SHIM. [44]

Other cancers

SHG microscopy was reported for the study of lung, colonic, esophageal stroma and cervical cancers. [39]

Pathologies detection

Alterations in the organization or polarity of the collagen fibrils can be signs of pathology,. [45] [46]

In particular, the anisotropic alignment of collagen fibers allowed the discrimination of healthy dermis from pathological scars in skin. [47] Also, pathologies in cartilage such as osteoarthritis can be probed by polarization-resolved SHG microscopy,. [48] [49] SHIM was later extended to fibro-cartilage (meniscus). [50]

Tissue engineering

The ability of SHG to image specific molecules can reveal the structure of a certain tissue one material at a time, and at various scales (from macro to micro) using microscopy. For instance, the collagen (type I) is specifically imaged from the extracellular matrix (ECM) of cells, or when it serves as a scaffold or conjonctive material in tissues. [51] SHG also reveals fibroin in silk, myosin in muscles and biosynthetized cellulose. All of this imaging capability can be used to design artificials tissues, by targeting specific points of the tissue : SHG can indeed quantitatively measure some orientations, and material quantity and arrangement. [51] Also, SHG coupled to other multiphoton techniques can serve to monitor the development of engineered tissues, when the sample is relatively thin however. [52] Of course, they can finally be used as a quality control of the fabricated tissues. [52]

Structure of the eye

Cornea, at the surface of the eye, is considered to be made of plywood-like structure of collagen, due to the self-organization properties of sufficiently dense collagen. [53] Yet, the collagenous orientation in lamellae is still under debate in this tissue. [54] Keratoconus cornea can also be imaged by SHG to reveal morphological alterations of the collagen. [55] Third-Harmonic Generation (THG) microscopy is moreover used to image the cornea, which is complementary to SHG signal as THG and SHG maxima in this tissue are often at different places. [56]

See also

Sources

Related Research Articles

<span class="mw-page-title-main">Microscopy</span> Viewing of objects which are too small to be seen with the naked eye

Microscopy is the technical field of using microscopes to view objects and areas of objects that cannot be seen with the naked eye. There are three well-known branches of microscopy: optical, electron, and scanning probe microscopy, along with the emerging field of X-ray microscopy.

<span class="mw-page-title-main">Nonlinear optics</span> Branch of physics

Nonlinear optics (NLO) is the branch of optics that describes the behaviour of light in nonlinear media, that is, media in which the polarization density P responds non-linearly to the electric field E of the light. The non-linearity is typically observed only at very high light intensities (when the electric field of the light is >108 V/m and thus comparable to the atomic electric field of ~1011 V/m) such as those provided by lasers. Above the Schwinger limit, the vacuum itself is expected to become nonlinear. In nonlinear optics, the superposition principle no longer holds.

<span class="mw-page-title-main">Spontaneous parametric down-conversion</span> Optical process

Spontaneous parametric down-conversion is a nonlinear instant optical process that converts one photon of higher energy, into a pair of photons of lower energy, in accordance with the law of conservation of energy and law of conservation of momentum. It is an important process in quantum optics, for the generation of entangled photon pairs, and of single photons.

Fluorescence-lifetime imaging microscopy or FLIM is an imaging technique based on the differences in the exponential decay rate of the photon emission of a fluorophore from a sample. It can be used as an imaging technique in confocal microscopy, two-photon excitation microscopy, and multiphoton tomography.

<span class="mw-page-title-main">Two-photon excitation microscopy</span> Fluorescence imaging technique

Two-photon excitation microscopy is a fluorescence imaging technique that is particularly well-suited to image scattering living tissue of up to about one millimeter in thickness. Unlike traditional fluorescence microscopy, where the excitation wavelength is shorter than the emission wavelength, two-photon excitation requires simultaneous excitation by two photons with longer wavelength than the emitted light. The laser is focused onto a specific location in the tissue and scanned across the sample to sequentially produce the image. Due to the non-linearity of two-photon excitation, mainly fluorophores in the micrometer-sized focus of the laser beam are excited, which results in the spatial resolution of the image. This contrasts with confocal microscopy, where the spatial resolution is produced by the interaction of excitation focus and the confined detection with a pinhole.

<span class="mw-page-title-main">Autofluorescence</span>

Autofluorescence is the natural emission of light by biological structures such as mitochondria and lysosomes when they have absorbed light, and is used to distinguish the light originating from artificially added fluorescent markers (fluorophores).

<span class="mw-page-title-main">Two-photon absorption</span> Simultaneous absorption of two photons by a molecule

In atomic physics, two-photon absorption (TPA or 2PA), also called two-photon excitation or non-linear absorption, is the simultaneous absorption of two photons of identical or different frequencies in order to excite an atom or a molecule from one state (usually the ground state), via a virtual energy level, to a higher energy, most commonly an excited electronic state. Absorption of two photons with different frequencies is called non-degenerate two-photon absorption. Since TPA depends on the simultaneous absorption of two photons, the probability of TPA is proportional to the photon dose (D), which is proportional to the square of the light intensity (D ∝ I2); thus it is a nonlinear optical process. The energy difference between the involved lower and upper states of the molecule is equal or smaller than the sum of the photon energies of the two photons absorbed. Two-photon absorption is a third-order process, with absorption cross section typically several orders of magnitude smaller than one-photon absorption cross section.

<span class="mw-page-title-main">Second-harmonic generation</span> Nonlinear optical process

Second-harmonic generation (SHG), also known as frequency doubling, is the lowest-order wave-wave nonlinear interaction that occurs in various systems, including optical, radio, atmospheric, and magnetohydrodynamic systems. As a prototype behavior of waves, SHG is widely used, for example, in doubling laser frequencies. SHG was initially discovered as a nonlinear optical process in which two photons with the same frequency interact with a nonlinear material, are "combined", and generate a new photon with twice the energy of the initial photons, that conserves the coherence of the excitation. It is a special case of sum-frequency generation (2 photons), and more generally of harmonic generation.

<span class="mw-page-title-main">Harmonic generation</span> Nonlinear optical process

Harmonic generation is a nonlinear optical process in which photons with the same frequency interact with a nonlinear material, are "combined", and generate a new photon with times the energy of the initial photons.

<span class="mw-page-title-main">Bruce J. Tromberg</span> American chemist

Bruce J. Tromberg is an American photochemist and a leading researcher in the field of biophotonics. He is the director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB) within the National Institutes of Health (NIH). Before joining NIH, he was Professor of Biomedical Engineering at The Henry Samueli School of Engineering and of Surgery at the School of Medicine, University of California, Irvine. He was the principal investigator of the Laser Microbeam and Medical Program (LAMMP), and the Director of the Beckman Laser Institute and Medical Clinic at Irvine. He was a co-leader of the Onco-imaging and Biotechnology Program of the NCI Chao Family Comprehensive Cancer Center at Irvine.

Surface second harmonic generation is a method for probing interfaces in atomic and molecular systems. In second harmonic generation (SHG), the light frequency is doubled, essentially converting two photons of the original beam of energy E into a single photon of energy 2E as it interacts with noncentrosymmetric media. Surface second harmonic generation is a special case of SHG where the second beam is generated because of a break of symmetry caused by an interface. Since centrosymmetric symmetry in centrosymmetric media is only disrupted in the first atomic or molecular layer of a system, properties of the second harmonic signal then provide information about the surface atomic or molecular layers only. Surface SHG is possible even for materials which do not exhibit SHG in the bulk. Although in many situations the dominant second harmonic signal arises from the broken symmetry at the surface, the signal in fact always has contributions from both the surface and bulk. Thus, the most sensitive experiments typically involve modification of a surface and study of the subsequent modification of the harmonic generation properties.

<span class="mw-page-title-main">Multiphoton lithography</span> Technique for creating microscopic structures

Multiphoton lithography of polymer templates has been known for years by the photonic crystal community. Similar to standard photolithography techniques, structuring is accomplished by illuminating negative-tone or positive-tone photoresists via light of a well-defined wavelength. A critical difference is, however, the avoidance of photomasks. Instead, two-photon absorption is utilized to induce a dramatic change in the solubility of the resist for appropriate developers.

A parametric process is an optical process in which light interacts with matter in such a way as to leave the quantum state of the material unchanged. As a direct consequence of this there can be no net transfer of energy, momentum, or angular momentum between the optical field and the physical system. In contrast a non-parametric process is a process in which any part of the quantum state of the system changes.

<span class="mw-page-title-main">Two-photon circular dichroism</span>

Two-photon circular dichroism (TPCD), the nonlinear counterpart of electronic circular dichroism (ECD), is defined as the differences between the two-photon absorption (TPA) cross-sections obtained using left circular polarized light and right circular polarized light.

Wide-field multiphoton microscopy refers to an optical non-linear imaging technique tailored for ultrafast imaging in which a large area of the object is illuminated and imaged without the need for scanning. High intensities are required to induce non-linear optical processes such as two-photon fluorescence or second harmonic generation. In scanning multiphoton microscopes the high intensities are achieved by tightly focusing the light, and the image is obtained by beam scanning. In wide-field multiphoton microscopy the high intensities are best achieved using an optically amplified pulsed laser source to attain a large field of view (~100 µm). The image in this case is obtained as a single frame with a CCD without the need of scanning, making the technique particularly useful to visualize dynamic processes simultaneously across the object of interest. With wide-field multiphoton microscopy the frame rate can be increased up to a 1000-fold compared to multiphoton scanning microscopy. Wide-field multiphoton microscopes are not yet commercially available, but working prototypes exist in several optics laboratories.

Super-resolution photoacoustic imaging is a set of techniques used to enhance spatial resolution in photoacoustic imaging. Specifically, these techniques primarily break the optical diffraction limit of the photoacoustic imaging system. It can be achieved in a variety of mechanisms, such as blind structured illumination, multi-speckle illumination, or photo-imprint photoacoustic microscopy in Figure 1.

Three-photon microscopy (3PEF) is a high-resolution fluorescence microscopy based on nonlinear excitation effect. Different from two-photon excitation microscopy, it uses three exciting photons. It typically uses 1300 nm or longer wavelength lasers to excite the fluorescent dyes with three simultaneously absorbed photons. The fluorescent dyes then emit one photon whose energy is three times the energy of each incident photon. Compared to two-photon microscopy, three-photon microscopy reduces the fluorescence away from the focal plane by , which is much faster than that of two-photon microscopy by . In addition, three-photon microscopy employs near-infrared light with less tissue scattering effect. This causes three-photon microscopy to have higher resolution than conventional microscopy.

<span class="mw-page-title-main">Coherent Raman scattering microscopy</span> Multi-photon microscopy technique

Coherent Raman scattering (CRS) microscopy is a multi-photon microscopy technique based on Raman-active vibrational modes of molecules. The two major techniques in CRS microscopy are stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS). SRS and CARS were theoretically predicted and experimentally realized in the 1960s. In 1982 the first CARS microscope was demonstrated. In 1999, CARS microscopy using a collinear geometry and high numerical aperture objective were developed in Xiaoliang Sunney Xie's lab at Harvard University. This advancement made the technique more compatible with modern laser scanning microscopes. Since then, CRS's popularity in biomedical research started to grow. CRS is mainly used to image lipid, protein, and other bio-molecules in live or fixed cells or tissues without labeling or staining. CRS can also be used to image samples labeled with Raman tags, which can avoid interference from other molecules and normally allows for stronger CRS signals than would normally be obtained for common biomolecules. CRS also finds application in other fields, such as material science and environmental science.

Ultrafast scanning electron microscopy (UFSEM) combines two microscopic modalities, Pump-probe microscopy and Scanning electron microscope, to gather temporal and spatial resolution phenomena. The technique uses ultrashort laser pulses for pump excitation of the material and the sample response will be detected by an Everhart-Thornley detector. Acquiring data depends mainly on formation of images by raster scan mode after pumping with short laser pulse at different delay times. The characterization of the output image will be done through the temporal resolution aspect. Thus, the idea is to exploit the shorter DeBroglie wavelength in respect to the photons which has great impact to increase the resolution about 1 nm. That technique is an up-to-date approach to study the dynamic of charge on material surfaces.

<span class="mw-page-title-main">Marie-Claire Schanne-Klein</span> French physicist and academic

Marie-Claire Schanne-Klein is a French physicist who is a professor at the French National Centre for Scientific Research. She is based in the Laboratory for Optics and Biosciences, where she studies the nonlinear optics of chiral molecules.

References

  1. Juan Carlos Stockert, Alfonso Blázquez-Castro (2017). "Chapter 19 Non-Linear Optics". Fluorescence Microscopy in Life Sciences. Bentham Science Publishers. pp. 642–686. ISBN   978-1-68108-519-7 . Retrieved 24 December 2017.
  2. 1 2 Roesel, D.; Eremchev, M.; Schönfeldová, T.; Lee, S.; Roke, S. (2022-04-18). "Water as a contrast agent to quantify surface chemistry and physics using second harmonic scattering and imaging: A perspective". Applied Physics Letters. 120 (16). AIP Publishing: 160501. Bibcode:2022ApPhL.120p0501R. doi: 10.1063/5.0085807 . ISSN   0003-6951. S2CID   248252664.
  3. 1 2 Nucciotti, V.; Stringari, C.; Sacconi, L.; Vanzi, F.; Fusi, L.; Linari, M.; Piazzesi, G.; Lombardi, V.; Pavone, F. S. (2010). "Probing myosin structural conformation in vivo by second-harmonic generation microscopy". Proceedings of the National Academy of Sciences. 107 (17): 7763–7768. Bibcode:2010PNAS..107.7763N. doi: 10.1073/pnas.0914782107 . ISSN   0027-8424. PMC   2867856 . PMID   20385845.
  4. 1 2 Chen, Xiyi; Campagnola, P.J. (2016). "SHG Microscopy and Its Comparison with THG, CARS, and Multiphoton Excited Fluorescence Imaging". Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.
  5. Franken, Peter; Weinreich, G; Peters, CW; Hill, AE (1961). "Generation of Optical Harmonics". Physical Review Letters. 7 (4): 118–119. Bibcode:1961PhRvL...7..118F. doi: 10.1103/PhysRevLett.7.118 .
  6. Bloembergen, N.; Chang, R. K.; Jha, S. S.; Lee, C. H. (1968). "Optical Second-Harmonic Generation in Reflection from Media with Inversion Symmetry". Physical Review. 174 (813): 813–822. Bibcode:1968PhRv..174..813B. doi:10.1103/PhysRev.174.813.
  7. Fine, S.; Hansen, W. P. (1971). "Optical second harmonic generation in biological systems". Applied Optics. 10 (10): 2350–2353. Bibcode:1971ApOpt..10.2350F. doi:10.1364/AO.10.002350. PMID   20111328.
  8. Hellwarth, Robert; Christensen, Paul (1974). "Nonlinear optical microscopic examination of structure in polycrystalline ZnSe". Optics Communications. 12 (3): 318–322. Bibcode:1974OptCo..12..318H. doi:10.1016/0030-4018(74)90024-8.
  9. 1 2 Freund, I.; Deutsch, M. (1986). "Second-harmonic microscopy of biological tissue". Optics Letters. 11 (2): 94–96. Bibcode:1986OptL...11...94F. doi:10.1364/OL.11.000094. PMID   19730544.
  10. Brakenhoff, G.J.; Sonoda, Y.; Squier, J.; Norris, T.; Bliton, A.C.; Wade, M.H.; Athey, B. (1996). "Real-time two-photon confocal microscopy using afemtosecond, amplified Tisapphire system". Journal of Microscopy. 181 (3): 253–259. doi:10.1046/j.1365-2818.1996.97379.x. hdl: 2027.42/71623 . PMID   8642584. S2CID   12174100.
  11. Mizutani, G.; Sonoda, Y.; Sano, H.; Sakamoto, M.; Takahashi, T.; Ushioda, S. (2000). "Detection of starch granules in a living plant by optical second harmonic microscopy". Journal of Luminescence. 87: 824–826. Bibcode:2000JLum...87..824M. doi:10.1016/S0022-2313(99)00428-7.
  12. Zhao, Yue; Takahashi, Shogo; Li, Yanrong; Hien, K. T. T.; Matsubara, Akira; Mizutani, Goro; Nakamura, Yasunori (2018). "Ungerminated Rice Grains Observed by Femtosecond Pulse Laser Second-Harmonic Generation Microscopy". J. Phys. Chem. B. 122 (32): 7855–7861. arXiv: 1808.05449 . doi:10.7566/JPSJ.86.124401. PMID   30040415. S2CID   51687400.
  13. 1 2 Zhao, Yue; Hien, Khuat Thi Thu; Mizutani, Goro; Rutt, Harvey N.; Amornwachirabodee, Kittima; Okajima, Maiko; Kaneko, Tatsuo (2017). "Optical second-harmonic images of sacran megamolecule aggregates". Journal of the Optical Society of America A. 34 (2): 146–152. arXiv: 1702.07165 . Bibcode:2017JOSAA..34..146Z. doi:10.1364/JOSAA.34.000146. PMID   28157840. S2CID   4533122.
  14. 1 2 Zhao, Yue; Hien, Khuat Thi Thu; Mizutani, Goro; Rutt, Harvey N. (June 2017). "Second-order nonlinear optical microscopy of spider silk". Applied Physics B. 123 (6): 188. arXiv: 1706.03186 . Bibcode:2017ApPhB.123..188Z. doi:10.1007/s00340-017-6766-z. S2CID   51684427.
  15. Zhao, Yue; Li, Yanrong; Hien, K. T. T.; Mizutani, Goro; Rutt, Harvey N. (2019). "Observation of Spider Silk by Femtosecond Pulse Laser Second Harmonic Generation Microscopy". Surf. Interface Anal. 51 (1): 50–56. arXiv: 1812.10390 . doi:10.1002/sia.6545. S2CID   104921418.
  16. Cohen, B. E. (2010). "Biological imaging: Beyond fluorescence". Nature. 467 (7314): 407–8. Bibcode:2010Natur.467..407C. doi: 10.1038/467407a . PMID   20864989. S2CID   205058963.
  17. Pantazis, P.; Maloney, J.; Wu, D.; Fraser, S. (2010). "Second harmonic generating (SHG) nanoprobes for in vivo imaging". Proceedings of the National Academy of Sciences of the United States of America. 107 (33): 14535–14540. Bibcode:2010PNAS..10714535P. doi: 10.1073/pnas.1004748107 . PMC   2930484 . PMID   20668245.
  18. 1 2 Grubbs, Benjamin; Etter, Nicholas; Slaughter, Wesley; Pittsford, Alexander; Smith, Connor; Schmitt, Paul (August 2019). "A Low-Cost Beam-Scanning Second Harmonic Generation Microscope with Application for Agrochemical Development and Testing". Analytical Chemistry. 91 (18): 11723–11730. doi:10.1021/acs.analchem.9b02304. PMID   31424922. S2CID   201099822.
  19. 1 2 Campagnola, Paul J; Loew, Leslie M (2003). "Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms". Nature Biotechnology. 21 (11): 1356–1360. doi:10.1038/nbt894. ISSN   1087-0156. PMID   14595363. S2CID   18701570.
  20. 1 2 Chen, Xiyi; Nadiarynkh, Oleg; Plotnikov, Sergey; Campagnola, Paul J (2012). "Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure". Nature Protocols. 7 (4): 654–669. doi:10.1038/nprot.2012.009. ISSN   1754-2189. PMC   4337962 . PMID   22402635.
  21. Cicchi, Riccardo; Sacconi, Leonardo; Vanzi, Francesco; Pavone, Francesco S. (2016). "How to Build an SHG Apparatus" in Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.
  22. Stoller, P.; Reiser, K.; Celliers, P.; Rubenchik, A. (2002). "Polarization-modulated second harmonic generation in collagen". Biophys. J. 82 (6): 3330–3342. Bibcode:2002BpJ....82.3330S. doi:10.1016/S0006-3495(02)75673-7. PMC   1302120 . PMID   12023255.
  23. Duboisset, Julien; Aït-Belkacem, Dora; Roche, Muriel; Rigneault, Hervé; Brasselet, Sophie (2012). "Generic model of the molecular orientational distribution probed by polarization-resolved second-harmonic generation" (PDF). Physical Review A. 85 (4): 043829. Bibcode:2012PhRvA..85d3829D. doi:10.1103/PhysRevA.85.043829. ISSN   1050-2947. S2CID   85559569.
  24. Teulon, Claire; Gusachenko, Ivan; Latour, Gaël; Schanne-Klein, Marie-Claire (2015). "Theoretical, numerical and experimental study of geometrical parameters that affect anisotropy measurements in polarization-resolved SHG microscopy" (PDF). Optics Express. 23 (7): 9313–28. Bibcode:2015OExpr..23.9313T. doi: 10.1364/OE.23.009313 . ISSN   1094-4087. PMID   25968762.
  25. 1 2 Gusachenko, Ivan; Tran, Viet; Houssen, Yannick Goulam; Allain, Jean-Marc; Schanne-Klein, Marie-Claire (2012). "Polarization-Resolved Second-Harmonic Generation in Tendon upon Mechanical Stretching". Biophysical Journal. 102 (9): 2220–2229. Bibcode:2012BpJ...102.2220G. doi:10.1016/j.bpj.2012.03.068. ISSN   0006-3495. PMC   3341536 . PMID   22824287.
  26. Mazumder, Nirmal; Deka, Gitanjal; Wu, Wei-Wen; Gogoi, Ankur; Zhuo, Guan-Yu; Kao, Fu-Jen (2017). "Polarization resolved second harmonic microscopy". Methods. 128: 105–118. doi:10.1016/j.ymeth.2017.06.012. ISSN   1046-2023. PMID   28624539.
  27. 1 2 3 Marie-Claire Schanne-Klein (2016). "SHG Imaging of Collagen and Application to Fibrosis Quantization" in Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.
  28. Nuriya, Mutsuo; Jiang, Jiang; Nemet, Boaz; Eisenthal, Kenneth B.; Yuste, Rafael (2006). "Imaging membrane potential in dendritic spines". PNAS . 103 (3): 786–790. Bibcode:2006PNAS..103..786N. doi: 10.1073/pnas.0510092103 . PMC   1334676 . PMID   16407122.
  29. Gu, Bobo; Pliss, Artem; Kuzmin, Andrey N. (2016). "In-situ second harmonic generation by cancer cell targeting ZnO nanocrystals to effect photodynamic action in subcellular space". Biomaterials. 104: 78–86. doi: 10.1016/j.biomaterials.2016.07.012 . PMID   27442221.
  30. Psilodimitrakopoulos, Sotiris; Amat-Roldan, Ivan; Loza-Alvarez, Pablo; Artigas, David (2010). "Estimating the helical pitch angle of amylopectin in starch using polarization second harmonic generation microscopy". Journal of Optics. 12 (8): 084007. Bibcode:2010JOpt...12h4007P. doi:10.1088/2040-8978/12/8/084007. hdl: 2117/10342 . ISSN   2040-8978. S2CID   120603827.
  31. Pavone, Francesco S.; Campagnola, P.J. (2016). Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.
  32. Van Steenbergen, V.; Boesmans, W.; Li, Z.; de Coene, Y.; Vints, K.; Baatsen, P.; Dewachter, I.; Ameloot, M.; Clays, K.; Vanden Berghe, P. (2019). "Molecular understanding of label-free second harmonic imaging of microtubules". Nature Communications. 10 (1): 3530. Bibcode:2019NatCo..10.3530V. doi:10.1038/s41467-019-11463-8. ISSN   2041-1723. PMC   6684603 . PMID   31387998.
  33. Roesel, D.; Eremchev, M.; Schönfeldová, T.; Lee, S.; Roke, S. (18 April 2022). "Water as a contrast agent to quantify surface chemistry and physics using second harmonic scattering and imaging: A perspective". Applied Physics Letters. 120 (16): 160501. Bibcode:2022ApPhL.120p0501R. doi: 10.1063/5.0085807 . eISSN   1077-3118. ISSN   0003-6951. S2CID   248252664.
  34. Roesel, David; Eremchev, Maksim; Poojari, Chetan S.; Hub, Jochen S.; Roke, Sylvie (15 December 2022). "Ion-Induced Transient Potential Fluctuations Facilitate Pore Formation and Cation Transport through Lipid Membranes". Journal of the American Chemical Society. 144 (51): 23352–23357. doi:10.1021/jacs.2c08543. eISSN   1520-5126. ISSN   0002-7863. PMC   9801421 . PMID   36521841.
  35. Barad, Y.; Eisenberg, H.; Horowitz, M.; Silberberg, Y. (1997). "Nonlinear scanning laser microscopy by third harmonic generation". Applied Physics Letters. 70 (8): 922–924. Bibcode:1997ApPhL..70..922B. doi:10.1063/1.118442. ISSN   0003-6951.
  36. Olivier, N.; Luengo-Oroz, M. A.; Duloquin, L.; Faure, E.; Savy, T.; Veilleux, I.; Solinas, X.; Debarre, D.; Bourgine, P.; Santos, A.; Peyrieras, N.; Beaurepaire, E. (2010). "Cell Lineage Reconstruction of Early Zebrafish Embryos Using Label-Free Nonlinear Microscopy" (PDF). Science. 329 (5994): 967–971. Bibcode:2010Sci...329..967O. doi:10.1126/science.1189428. ISSN   0036-8075. PMID   20724640. S2CID   6971291.
  37. Alowami, Salem; Troup, Sandra; Al-Haddad, Sahar; Kirkpatrick, Iain; Watson, Peter H (2003). "Mammographic density is related to stroma and stromal proteoglycan expression". Breast Cancer Research. 5 (5): R129-35. doi: 10.1186/bcr622 . ISSN   1465-542X. PMC   314426 . PMID   12927043.
  38. König, Karsten (2018). "Multiphoton Tomography (MPT)" Chap.13 in Multiphoton Microscopy and Fluorescence Lifetime Imaging - Applications in Biology and Medicine. De Gruyter. ISBN   978-3-11-042998-5.
  39. 1 2 3 4 5 Keikhosravi, Adib; Bredfeldt, Jeremy S.; Sagar, Abdul Kader; Eliceiri, Kevin W. (2014). "Second-harmonic generation imaging of cancer". Quantitative Imaging in Cell Biology. Methods in Cell Biology. Vol. 123. pp. 531–546. doi:10.1016/B978-0-12-420138-5.00028-8. ISBN   978-0-12-420138-5. ISSN   0091-679X. PMID   24974046.
  40. Provenzano, Paolo P; Eliceiri, Kevin W; Campbell, Jay M; Inman, David R; White, John G; Keely, Patricia J (2006). "Collagen reorganization at the tumor-stromal interface facilitates local invasion". BMC Medicine. 4 (38): 38. doi: 10.1186/1741-7015-4-38 . PMC   1781458 . PMID   17190588.
  41. Nadiarnykh, Oleg; LaComb, Ronald B; Brewer, Molly A; Campagnola, Paul J (2010). "Alterations of the extracellular matrix in ovarian cancer studied by Second Harmonic Generation imaging microscopy". BMC Cancer. 10 (1): 94. doi: 10.1186/1471-2407-10-94 . ISSN   1471-2407. PMC   2841668 . PMID   20222963.
  42. Lin, Sung-Jan; Jee, Shiou-Hwa; Kuo, Chien-Jui; Wu, Ruei-Jr; Lin, Wei-Chou; Chen, Jau-Shiuh; Liao, Yi-Hua; Hsu, Chih-Jung; Tsai, Tsen-Fang; Chen, Yang-Fang; Dong, Chen-Yuan (2006). "Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging". Optics Letters. 31 (18): 2756–8. Bibcode:2006OptL...31.2756L. doi:10.1364/OL.31.002756. ISSN   0146-9592. PMID   16936882.
  43. Chen, Szu-Yu; Chen, Shee-Uan; Wu, Hai-Yin; Lee, Wen-Jeng; Liao, Yi-Hua; Sun, Chi-Kuang (2009). "In Vivo Virtual Biopsy of Human Skin by Using Noninvasive Higher Harmonic Generation Microscopy" (PDF). IEEE Journal of Selected Topics in Quantum Electronics. 16 (3): 478–492. doi:10.1109/JSTQE.2009.2031987. S2CID   21644641.
  44. Tokarz, Danielle; Cisek, Richard; Joseph, Ariana; Golaraei, Ahmad; Mirsanaye, Kamdin; Krouglov, Serguei; Asa, Sylvia L.; Wilson, Brian C.; Barzda, Virginijus (2019). "Characterization of Pancreatic Cancer Tissue Using Multiphoton Excitation Fluorescence and Polarization-Sensitive Harmonic Generation Microscopy". Frontiers in Oncology. 9: 272. doi: 10.3389/fonc.2019.00272 . ISSN   2234-943X. PMC   6478795 . PMID   31058080.
  45. König, Karsten (2018). Multiphoton Microscopy and Fluorescence Lifetime Imaging - Applications in Biology and Medicine. De Gruyter. ISBN   978-3-11-042998-5.
  46. Cicchi, Riccardo (2014). "The New Digital Pathology: Just Say NLO". Digestive Diseases and Sciences. 59 (7): 1347–1348. doi: 10.1007/s10620-014-3165-8 . ISSN   0163-2116. PMID   24817337.
  47. Cicchi, Riccardo; Vogler, Nadine; Kapsokalyvas, Dimitrios; Dietzek, Benjamin; Popp, Jürgen; Pavone, Francesco Saverio (2013). "From molecular structure to tissue architecture: collagen organization probed by SHG microscopy". Journal of Biophotonics. 6 (2): 129–142. doi: 10.1002/jbio.201200092 . ISSN   1864-063X. PMID   22791562. Open Access logo PLoS transparent.svg
  48. Mansfield, Jessica C.; Winlove, C. Peter; Moger, Julian; Matcher, Steve J. (2008). "Collagen fiber arrangement in normal and diseased cartilage studied by polarization sensitive nonlinear microscopy". Journal of Biomedical Optics. 13 (4): 044020. Bibcode:2008JBO....13d4020M. doi:10.1117/1.2950318. hdl: 10036/4485 . ISSN   1083-3668. PMID   19021348. S2CID   25096045. Open Access logo PLoS transparent.svg
  49. Yeh, Alvin T.; Hammer-Wilson, Marie J.; Van Sickle, David C.; Benton, Hilary P.; Zoumi, Aikaterini; Tromberg, Bruce J.; Peavy, George M. (2005). "Nonlinear optical microscopy of articular cartilage". Osteoarthritis and Cartilage. 13 (4): 345–352. doi: 10.1016/j.joca.2004.12.007 . ISSN   1063-4584. PMID   15780648. S2CID   20052077. Open Access logo PLoS transparent.svg
  50. Han, Woojin M.; Heo, Su-Jin; Driscoll, Tristan P.; Delucca, John F.; McLeod, Claire M.; Smith, Lachlan J.; Duncan, Randall L.; Mauck, Robert L.; Elliott, Dawn M. (2016). "Microstructural heterogeneity directs micromechanics and mechanobiology in native and engineered fibrocartilage". Nature Materials. 15 (4): 477–484. Bibcode:2016NatMa..15..477H. doi:10.1038/nmat4520. ISSN   1476-1122. PMC   4805445 . PMID   26726994.
  51. 1 2 Chen, W.L.; Lee, H.S. (2016). "SHG Imaging for Tissue Engineering Applications". Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.
  52. 1 2 Enejder, A.; Brackmann, C. (2020). "Use of Multiphoton Microscopy for Tissue Engineering Applications". Imaging in Cellular and Tissue Engineering, 1st edition. CRC Taylor&Francis. ISBN   9780367445867.
  53. Krachmer, J.H.; Mannis, M.J.; Holland, E.J. (2005). Cornea, Fundamentals, Diagnosis and Management. 2nd edition. Elsevier Mosby. ISBN   0323023150.
  54. Bueno, Juan M.; Ávila, Francisco J.; Martínez-García, M. Carmen (2019). "Quantitative Analysis of the Corneal Collagen Distribution after In Vivo Cross-Linking with Second Harmonic Microscopy". BioMed Research International. 2019: 3860498. doi: 10.1155/2019/3860498 . ISSN   2314-6133. PMC   6348900 . PMID   30756083.
  55. Morishige, N.; Shin-gyou-uchi, R.; Azumi, H.; Ohta, H.; Morita, Y.; Yamada, N.; Kimura, K.; Takahara, A.; Sonoda, K.-H. (2014). "Quantitative Analysis of Collagen Lamellae in the Normal and Keratoconic Human Cornea by Second Harmonic Generation Imaging Microscopy". Investigative Ophthalmology & Visual Science. 55 (12): 8377–8385. doi:10.1167/iovs.14-15348. ISSN   0146-0404. PMID   25425311.
  56. Olivier, N.; Débarre, D.; Beaurepaire, E. (2016). "THG Microscopy of Cells and Tissues: Contrast Mechanisms and Applications". Second Harmonic Generation Imaging, 2nd edition. CRC Taylor&Francis. ISBN   978-1-4398-4914-9.