Cold-formed steel (CFS) is the common term for steel products shaped by cold-working processes carried out near room temperature, such as rolling, pressing, stamping, bending, etc. Stock bars and sheets of cold-rolled steel (CRS) are commonly used in all areas of manufacturing. The terms are opposed to hot-formed steel and hot-rolled steel.
Cold-formed steel, especially in the form of thin gauge sheets, is commonly used in the construction industry for structural or non-structural items such as columns, beams, joists, studs, floor decking, built-up sections and other components. Such uses have become more and more popular in the US since their standardization in 1946.
Cold-formed steel members have been used also in bridges, storage racks, grain bins, car bodies, railway coaches, highway products, transmission towers, transmission poles, drainage facilities, firearms, various types of equipment and others. [1] [2] These types of sections are cold-formed from steel sheet, strip, plate, or flat bar in roll forming machines, by press brake (machine press) or bending operations. The material thicknesses for such thin-walled steel members usually range from 0.0147 in. (0.373 mm) to about ¼ in. (6.35 mm). Steel plates and bars as thick as 1 in. (25.4 mm) can also be cold-formed successfully into structural shapes (AISI, 2007b). [3]
The use of cold-formed steel members in building construction began in the 1850s in both the United States and Great Britain. In the 1920s and 1930s, acceptance of cold-formed steel as a construction material was still limited because there was no adequate design standard and limited information on material use in building codes. One of the first documented uses of cold-formed steel as a building material is the Virginia Baptist Hospital, [4] constructed around 1925 in Lynchburg, Virginia. The walls were load bearing masonry, but the floor system was framed with double back-to-back cold-formed steel lipped channels. According to Chuck Greene, P.E., of Nolen Frisa Associates, [5] the joists were adequate to carry the initial loads and spans, based on current analysis techniques. Greene engineered a recent renovation to the structure and said that for the most part, the joists are still performing well. A site observation during this renovation confirmed that "these joists from the 'roaring twenties' are still supporting loads, over 80 years later!" In the 1940s, Lustron Homes built and sold almost 2500 steel-framed homes, with the framing, finishes, cabinets and furniture made from cold-formed steel.
Design standards for hot-rolled steel (see structural steel) were adopted in 1930s, but were not applicable to cold–formed sections because of their relatively thin steel walls which were susceptible to buckling. Cold-formed steel members maintain a constant thickness around their cross-section, whereas hot-rolled shapes typically exhibit tapering or fillets. Cold-formed steel allowed for shapes which differed greatly from the classical hot-rolled shapes. The material was easily workable; it could be deformed into many possible shapes. Even a small change in the geometry created significant changes in the strength characteristics of the section. It was necessary to establish some minimum requirements and laws to control the buckling and strength characteristics. Also it was observed that the thin walls underwent local buckling under small loads in some sections and that these elements were then capable of carrying higher loads even after local buckling of the members.
In the United States, the first edition of the Specification for the Design of Light Gage Steel Structural Members was published by the American Iron and Steel Institute (AISI) in 1946 (AISI, 1946). [6] The first Allowable Stress Design (ASD) Specification was based on the research work sponsored by AISI at Cornell University under the direction of late Professor George Winter since 1939. [7] As a result of this work, George Winter is now considered the grandfather of cold-formed steel design. The ASD Specification was subsequently revised in 1956, 1960, 1962, 1968, 1980, and 1986 to reflect the technical developments and the results of continued research at Cornell and other universities (Yu et al., 1996). [8] In 1991, AISI published the first edition of the Load and Resistance Factor Design Specification developed at Missouri University of Science and Technology and Washington University in St. Louis under the directions of Wei-Wen Yu and Theodore V. Galambos (AISI, 1991). [9] Both ASD and LRFD Specifications were combined into a single specification in 1996 (AISI, 1996). [10]
In 2001, the first edition of the North American Specification for the Design of Cold-Formed Steel Structural Members was developed by a joint effort of the AISI Committee on Specifications, the Canadian Standards Association (CSA) Technical Committee on Cold-Formed Steel Structural Members, and Camara Nacional de la Industria del Hierro y del Acero (CANACERO) in Mexico (AISI, 2001). [11] It included the ASD and LRFD methods for the United States and Mexico together with the Limit States Design (LSD) method for Canada. This North American Specification has been accredited by the American National Standard Institute (ANSI) as an ANSI Standard to supersede the 1996 AISI Specification and the 1994 CSA Standard. Following the successful use of the 2001 edition of the North American Specification for six years, it was revised and expanded in 2007. [12]
This updated specification includes new and revised design provisions with the additions of the Direct Strength Method in Appendix 1 and the Second-Order Analysis of structural systems in Appendix 2.
In addition to the AISI specifications, the American Iron and Steel Institute has also published commentaries on various editions of the specifications, design manuals, framing design standards, various design guides, and design aids for using cold-formed steel. For details, see AISI website.
The United States, Mexico and Canada use the North American Specification for the Design of Cold-Formed Steel Structural Members, document number AISI S100-2007. Member states of the European Union use section 1-3 of the Eurocode 3 (EN 1993) for the design of cold formed steel members. Other nations utilize various design specifications, many based on AISI S-100, as adopted by the building codes listed below. Another list of international cold-formed steel codes and standards is maintained (and can be edited with permission) at Cold-Formed Steel Codes Around the World.
Ethiopia Building Codes: EBCS-1 Basis of design and actions on structures EBCS-3 Design of steel structures
United States Specification: North American Specification for the Design of Cold-Formed Steel Structural Members, document number AISI S100-2007 published by the American Iron and Steel Institute in October 2007. Building Code: IBC and/or NFPA may be enforced, but both reference AISI S100.
Canada Specification: North American Specification for the Design of Cold-Formed Steel Structural Members, document number CAN/CSA S136-07 as published by Canadian Standards Association. Building Code: The National Building Code of Canada is the model code adopted with amendments by individual Provinces and Territories. The Federal government is outside the jurisdiction of the Provincial/Territorial authority but usually defers to the legislated requirements within the Province/Territory of the building site.
Brazil Specification: NBR 14762:2001 Dimensionamento de estruturas de aço constituídas por perfis formados a frio - Procedimento (Cold-formed steel design - Procedure, last update 2001) and NBR 6355:2003 Perfis estruturais de aço formados a frio - Padronização (Cold-formed steel structural profiles, last update 2003) Building Code: ABNT - Associação Brasileira de Normas Técnicas (www.abnt.org.br)
Chile NCH 427 - suspended because it was written in the 1970s. Cold-formed steel sections were based in part on AISI (U.S). The local Institute for Building code INN has specified in recent Codes for seismic design that designers must use the last edition of the AISI Specification for cold formed steel and the AISC for hot rolled, in their original versions in English until some traduced adaption will be issued here .
Argentina CIRSOC 303 for Light Steel Structures where cold formed steel is included. That Specification, now more than 20 years old, is being replaced by a new one, which will be, in general, an adaption of the current AISI one. The former CIRSOC 303 was an adaption of the Canadian code of that time. At this time CIRSOC 303 was very old, now CIRSOC 301 is in revolution to be aligned with the American codes (LRFD design). In the near future both codes will be aligned also in designations and terminology.
Philippines National Structural Code of the Philippines 2010, Volume 1 Buildings, Towers, and other Vertical Structures, Chapter 5 Part 3 Design of Cold-Formed Steel Structural Members is based on AISI S100-2007
India Specification: IS:801 and IS:811, Indian standard code of practice for use of cold-formed light gauge steel structural members in general building construction, Bureau of Indian Standards, New Delhi (1975). (currently under revision) Building Code : see - model code National Building Code of India
China Specification: Technical Code of Cold-formed Thin-wall Steel Structures Building Code: GB 50018-2002 (current version)
Japan Specification: Design Manual of Light-gauge Steel Structures Building Code: Technical standard notification No.1641 concerning light-gauge steel structures
Malaysia Malaysia uses British Standard BS5950, especially BS5950:Part 5; AS4600 (from Australia) is also referenced.
EU Countries Specification: EN 1993-1-3 (same as Eurocode 3 part 1-3), Design of steel structures - Cold formed thin gauge members and sheeting. Each European country will get its own National Annex Documents (NAD).
Germany Specification: German Committee for Steel Structures (DASt), DASt-Guidelines 016: 1992: Calculation and design of structures with thin-walled cold-formed members; In German Building Code: EN 1993-1-3: 2006 (Eurocode 3 Part 1-3): Design of steel structures – General rules – Supplementary rules for cold-formed members and sheeting; German version prEN 1090 2: 2005 (prEN 1090 Part 2; Draft): Execution of steel structures and aluminium structures – Technical requirements for the execution of steel structures; German version EN 10162: 2003: Cold-rolled steel sections – Technical delivery conditions – Dimensional and cross-sectional tolerances; German version
Italy Specification: UNI CNR 10022 (National Document) EN 1993-1-3 (Not compulsory)
United Kingdom Eurocode for cold-formed steel in the UK. BS EN 1993-1-3:2006: Eurocode 3. Design of steel structures. General rules.
Australia Specification: AS/NZS 4600 AS/NZS 4600:2005 Similar to NAS 2007 but includes high strength steels such as G550 for all sections. (Greg Hancock) Building Code: Building Code of Australia (National document) calls AS/NZS 4600:2005
New Zealand Specification: AS/NZS 4600 (same as Australia)
In building construction there are basically two types of structural steel: hot-rolled steel shapes and cold-formed steel shapes. The hot rolled steel shapes are formed at elevated temperatures while the cold-formed steel shapes are formed at room temperature. Cold-formed steel structural members are shapes commonly manufactured from steel plate, sheet metal or strip material. The manufacturing process involves forming the material by either press-braking or cold roll forming to achieve the desired shape.
When steel is formed by press-braking or cold rolled forming, there is a change in the mechanical properties of the material by virtue of the cold working of the metal. When a steel section is cold-formed from flat sheet or strip the yield strength, and to a lesser extent the ultimate strength, are increased as a result of this cold working, particularly in the bends of the section.
Some of the main properties of cold formed steel are as follows: [13]
A broad classification of the cold-formed shapes used in the construction industry can be made as individual structural framing members or panels and decks.
Some of the popular applications and the preferred sections are:
The AISI Specification allows the use of steel to the following ASTM specifications in the table below: [14]
Steel Designation | ASTM Designation | Product | Yield Strength Fy (ksi) | Tensile Strength Fu (ksi) | Fu / Fy | Minimum Elongation (%) in 2-in. Gage Length |
---|---|---|---|---|---|---|
Carbon structural steel | A36 | 36 | 58-80 | 1.61 | 23 | |
A36 | 50 | 70 | 1.4 | 21 | ||
High-strength low-alloy Structural steel | A242 | 46 | 67 | 1.46 | 21 | |
Low and intermediate tensile strength carbon steel plates | A283 | |||||
A | 24 | 45-60 | 1.88 | 30 | ||
B | 27 | 50-65 | 1.85 | 28 | ||
C | 30 | 55-75 | 1.83 | 25 | ||
D | 33 | 60-80 | 1.82 | 23 | ||
Cold-formed welded and seamless carbon steel structural tubing in rounds and shapes | A500 | Round Tubing | ||||
A | 33 | 45 | 1.36 | 25 | ||
B | 42 | 58 | 1.38 | 23 | ||
C | 46 | 62 | 1.35 | 21 | ||
D | 36 | 58 | 1.61 | 23 | ||
Shape Tubing | ||||||
A | 39 | 45 | 1.15 | 25 | ||
B | 46 | 58 | 1.26 | 23 | ||
C | 50 | 62 | 1.24 | 21 | ||
D | 36 | 58 | 1.61 | 23 | ||
High-strength carbon–manganese steel | A529 Gr. 42 | 42 | 60-85 | 1.43 | 22 | |
A529 Gr. 50 | 50 | 70-100 | 1.40 | 21 | ||
Hot-rolled carbon steel sheets and strips of structural quality | A570 | |||||
Gr. 30 | 30 | 49 | 1.63 | 21 | ||
Gr. 33 | 33 | 52 | 1.58 | 18 | ||
Gr. 36 | 36 | 53 | 1.47 | 17 | ||
Gr. 40 | 40 | 55 | 1.38 | 15 | ||
Gr. 45 | 45 | 60 | 1.33 | 13 | ||
Gr. 50 | 50 | 65 | 1.30 | 11 | ||
High-strength low-alloy columbium– vanadium steels of structural quality | A572 | |||||
Gr. 42 | 42 | 60 | 1.43 | 24 | ||
Gr. 50 | 50 | 65 | 1.30 | 21 | ||
Gr. 60 | 60 | 75 | 1.25 | 18 | ||
Gr. 65 | 65 | 80 | 1.23 | 17 | ||
High-strength low-alloy structural steel with 50 ksi minimum yield point | A588 | 50 | 70 | 1.40 | 21 | |
Hot-rolled and cold-rolled high-strength low-alloy steel sheet and strip with improved corrosion resistance | A606 | Hot-rolled as rolled cut length | 50 | 70 | 1.40 | 22 |
Hot-rolled as rolled coils | 45 | 65 | 1.44 | 22 | ||
Hot-rolled annealed | 45 | 65 | 1.44 | 22 | ||
Cold-rolled | 45 | 65 | 1.44 | 22 | ||
Hot-rolled and cold-rolled high-strength low-alloy columbium and/or vanadium steel sheet and strip | A607 Class I | |||||
Gr.45 | 45 | 60 | 1.33 | Hot rolled (23) Cold rolled (22) | ||
Gr.50 | 50 | 65 | 1.30 | Hot rolled (20) Cold rolled (20) | ||
Gr.55 | 55 | 70 | 1.27 | Hot rolled (18) Cold rolled (18) | ||
Gr.60 | 60 | 75 | 1.25 | Hot rolled (16) Cold rolled (16) | ||
Gr.65 | 65 | 80 | 1.23 | Hot rolled (14) Cold rolled (15) | ||
Gr.70 | 70 | 85 | 1.21 | Hot rolled (12) Cold rolled (14) | ||
A607 Class II | ||||||
Gr.45 | 45 | 55 | 1.22 | Hot rolled (23) Cold rolled (22) | ||
Gr.50 | 50 | 60 | 1.20 | Hot rolled (20) Cold rolled (20) | ||
Gr.55 | 55 | 65 | 1.18 | Hot rolled (18) Cold rolled (18) | ||
Gr.60 | 60 | 70 | 1.17 | Hot rolled (16) Cold rolled (16) | ||
Gr.65 | 65 | 75 | 1.15 | Hot rolled (14) Cold rolled (15) | ||
Gr.70 | 70 | 80 | 1.14 | Hot rolled (12) Cold rolled (14) | ||
Cold-rolled carbon structural steel sheet | A611 | |||||
A | 25 | 42 | 1.68 | 26 | ||
B | 30 | 45 | 1.50 | 24 | ||
C | 33 | 48 | 1.45 | 22 | ||
D | 40 | 52 | 1.30 | 20 | ||
Zinc-coated or zinc-iron alloy-coated steel sheet | A653 SS | |||||
Gr. 33 | 33 | 45 | 1.36 | 20 | ||
Gr. 37 | 37 | 52 | 1.41 | 18 | ||
Gr. 40 | 40 | 55 | 1.38 | 16 | ||
50 Class 1 | 50 | 65 | 1.30 | 12 | ||
50 Class 3 | 50 | 70 | 1.40 | 12 | ||
HSLAS Type A | ||||||
50 | 50 | 60 | 1.20 | 20 | ||
60 | 60 | 70 | 1.17 | 16 | ||
70 | 70 | 80 | 1.14 | 12 | ||
80 | 80 | 90 | 1.13 | 10 | ||
HSLAS Type B | ||||||
50 | 50 | 60 | 1.20 | 22 | ||
60 | 60 | 70 | 1.17 | 18 | ||
70 | 70 | 80 | 1.14 | 14 | ||
80 | 80 | 90 | 1.13 | 12 | ||
Hot-rolled and cold-rolled high-strength low-alloy steel sheets and strip with improved formability | A715 | |||||
Gr. 50 | 50 | 60 | 1.20 | 22 | ||
Gr. 60 | 60 | 70 | 1.17 | 18 | ||
Gr. 70 | 70 | 80 | 1.14 | 14 | ||
Gr. 80 | 80 | 90 | 1.13 | 12 | ||
55% aluminum-zinc alloy-coated steel sheet by the hot-dip process | A792 | |||||
Gr. 33 | 33 | 45 | 1.36 | 20 | ||
Gr. 37 | 37 | 52 | 1.41 | 18 | ||
Gr. 40 | 40 | 55 | 1.38 | 16 | ||
Gr. 50A | 50 | 65 | 1.30 | 12 | ||
Cold-formed welded and seamless high-strength, low-alloy structural tubing with improved atmospheric corrosion resistance | A847 | 50 | 70 | 1.40 | 19 | |
Zinc-5% aluminum alloy-coated steel sheet by the hot-dip process | A875 SS | |||||
Gr. 33 | 33 | 45 | 1.36 | 20 | ||
Gr. 37 | 37 | 52 | 1.41 | 18 | ||
Gr. 40 | 40 | 55 | 1.38 | 16 | ||
50 Class 1 | 50 | 65 | 1.30 | 12 | ||
50 Class 3 | 50 | 70 | 1.40 | 12 | ||
HSLAS Type A | ||||||
50 | 50 | 60 | 1.20 | 20 | ||
60 | 60 | 70 | 1.17 | 16 | ||
70 | 70 | 80 | 1.14 | 12 | ||
80 | 80 | 90 | 1.13 | 10 | ||
HSLAS Type B | ||||||
50 | 50 | 60 | 1.20 | 22 | ||
60 | 60 | 70 | 1.17 | 18 | ||
70 | 70 | 80 | 1.14 | 14 | ||
80 | 80 | 90 | 1.13 | 12 |
A main property of steel, which is used to describe its behavior, is the stress–strain graph. The stress–strain graphs of cold-formed steel sheet mainly fall into two categories. They are sharp yielding and gradual yielding type illustrated below in Fig.1 and Fig.2, respectively.
These two stress–strain curves are typical for cold-formed steel sheet during tension test. The second graph is the representation of the steel sheet that has undergone the cold-reducing (hard rolling) during manufacturing process, therefore it does not exhibit a yield point with a yield plateau. The initial slope of the curve may be lowered as a result of the prework. Unlike Fig.1, the stress–strain relationship in Fig.2 represents the behavior of annealed steel sheet. For this type of steel, the yield point is defined by the level at which the stress–strain curve becomes horizontal.
Cold forming has the effect of increasing the yield strength of steel, the increase being the consequence of cold working well into the strain-hardening range. This increase is in the zones where the material is deformed by bending or working. The yield stress can be assumed to have been increased by 15% or more for design purposes. The yield stress value of cold-formed steel is usually between 33ksi and 80ksi. The measured values of modulus of elasticity based on the standard methods usually range from 29,000 to 30,000 ksi (200 to 207 GPa). A value of 29,500 ksi (203 GPa) is recommended by AISI in its specification for design purposes. The ultimate tensile strength of steel sheets in the sections has little direct relationship to the design of those members. The load-carrying capacities of cold-formed steel flexural and compression members are usually limited by yield point or buckling stresses that are less than the yield point of steel, particularly for those compression elements having relatively large flat-width ratios and for compression members having relatively large slenderness ratios. The exceptions are bolted and welded connections, the strength of which depends not only on the yield point but also on the ultimate tensile strength of the material. Studies indicate that the effects of cold work on formed steel members depend largely upon the spread between the tensile and the yield strength of the virgin material.
Ductility is defined as ‘'an extent to which a material can sustain plastic deformation without rupture.'’ It is not only required in the forming process but is also needed for plastic redistribution of stress in members and connections, where stress concentration would occur. The ductility criteria and performance of low-ductility steels for cold-formed members and connections have been studied by Dhalla, Winter, and Errera at Cornell University. It was found that the ductility measurement in a standard tension test includes local ductility and uniform ductility. Local ductility is designated as the localized elongation at the eventual fracture zone. Uniform ductility is the ability of a tension coupon to undergo sizeable plastic deformations along its entire length prior to necking. This study also revealed that for the different ductility steels investigated, the elongation in 2-in. (50.8-mm) gage length did not correlate satisfactorily with either the local or the uniform ductility of the material. In order to be able to redistribute the stresses in the plastic range to avoid premature brittle fracture and to achieve full net-section strength in a tension member with stress concentrations, it is suggested that:
Weldability refers to the capacity of steel to be welded into a satisfactory, crack free, sound joint under fabrication conditions without difficulty. [1] Welding is possible in cold-formed steel elements, but it shall follow the standards given in AISI S100-2007, Section E.
1.When thickness less than or equal to 3/16" (4.76mm):
The various possible welds in cold formed steel sections, where the thickness of the thinnest element in the connection is 3/16" or less are as follows
2.When thickness greater than or equal to 3/16" (4.76mm):
Welded connections in which thickness of the thinnest connected arc is greater than 3/16" (4.76mm) shall be in accordance with ANSI/AISC-360. The weld positions are covered as per AISI S100-2007 (Table E2a) [12]
Application | Shop or Field fabrication | Electrode method | Suggested minimum CFS thickness |
---|---|---|---|
CFS to Structural steel | Field-fabrication | Stick-welding | 54 to 68 mils |
CFS to Structural steel | Shop-fabrication | Stick-welding | 54 to 68 mils |
CFS to CFS | Field-fabrication | Stick-welding | 54 to 68 mils |
CFS to CFS | Field-fabrication | Wire-fed MIG (Metal Inert Gas) welding | 43 to 54 mils |
CFS to CFS | Shop-fabrication | Wire-fed MIG (Metal Inert Gas) welding | 33 mils |
Cold-formed steel framing (CFSF) refers specifically to members in light-frame building construction that are made entirely of sheet steel, formed to various shapes at ambient temperatures. The most common shape for CFSF members is a lipped channel, although "Z", "C", tubular, "hat" and other shapes and variations have been used. The building elements that are most often framed with cold-formed steel are floors, roofs, and walls, although other building elements and both structural and decorative assemblies may be steel framed.
Although cold-formed steel is used for several products in building construction, framing products are different in that they are typically used for wall studs, floor joists, rafters, and truss members. Examples of cold-formed steel that would not be considered framing includes metal roofing, roof and floor deck, composite deck, metal siding, and purlins and girts on metal buildings.
Framing members are typically spaced at 16 or 24 inches on center, with spacing variations lower and higher depending upon the loads and coverings. Wall members are typically vertical lipped channel "stud" members, which fit into unlipped channel "track" sections at the top and bottom. Similar configurations are used for both floor joist and rafter assemblies, but in a horizontal application for floors, and a horizontal or sloped application for roof framing. Additional elements of the framing system include fasteners and connectors, braces and bracing, clips and connectors.
In North America, member types have been divided into five major categories, and product nomenclature is based on those categories.
In high-rise commercial and multi-family residential construction, CFSF is typically used for interior partitions and support of exterior walls and cladding. In many mid-rise and low-rise applications, the entire structural system can be framed with CFSF.
Cold Rolled Steel Buildings are manufactured from pre-galvanised steel coil. With this, it means getting all components of a Cold Rolled frame and a galvanised finish with no need for additional coating or painting. [16]
Connectors are used in cold-formed steel construction to attach members (i.e. studs, joists) to each other or to the primary structure for the purpose of load transfer and support. Since an assembly is only as strong as its weakest component, it is important to engineer each connection so that it meets specified performance requirements. There are two main connection types, Fixed and Movement-Allowing (Slip). Fixed connections of framing members do not allow movement of the connected parts. They can be found in axial-load bearing walls, curtain walls, trusses, roofs, and floors. Movement-Allowing connections are designed to allow deflection of the primary structure in the vertical direction due to live load, or in the horizontal direction due to wind or seismic loads, or both vertical and horizontal directions. One application for a vertical movement-allowing connection is to isolate non-axial load bearing walls (drywall) from the vertical live load of the structure and to prevent damage to finishes. A common clip for this application is an L-shaped top-of-wall clip for walls that are infill between floors. These clips have slots perpendicular to the bend in the clip. Another common clip is the bypass clip for walls that bypass outside the edge of the floor structure. When these clips are L-shaped, they have slots that are parallel to the bend in the clip. If the structure is in an active seismic zone, vertical and horizontal movement-allowing connections may be used to accommodate both the vertical deflection and horizontal drift of the structure.
Connectors may be fastened to cold-formed steel members and primary structure using welds, bolts, or self-drilling screws. These fastening methods are recognized in the American Iron and Steel Institute (AISI) 2007 North American Specification for the Design of Cold-Formed Steel Structural Members, Chapter E. Other fastening methods, such as clinching, power actuated fasteners (PAF), mechanical anchors, adhesive anchors and structural glue, are used based on manufacturer's performance-based tests.
Hot rolled | Cold rolled | ||
---|---|---|---|
Material properties | Yielding strength | The material is not deformed; there is no initial strain in the material, hence yielding starts at actual yield value as the original material. | The yield value is increased by 15%–30% due to prework (initial deformation). |
Modulus of elasticity | 29,000 ksi | 29,500 ksi | |
Unit weight | Unit weight is comparatively huge. | It is much smaller. | |
Ductility | More ductile in nature. | Less ductile. | |
Design | Most of the time, we consider only the global buckling of the member. | Local buckling, Distortional Buckling, Global Buckling have to be considered. | |
Main uses | Load bearing structures, usually heavy load bearing structures and where ductility is more important ( Example Seismic prone areas) | Application in many variety of loading cases. This includes building frames, automobile, aircraft, home appliances, etc. Use limited in cases where high ductility requirements. | |
Flexibility of shapes | Standard shapes are followed. High value of unit weight limits the flexibility of manufacturing wide variety of shapes. | Any desired shape can be molded out of the sheets. The light weight enhances its variety of usage. | |
Economy | High Unit weight increases the overall cost – material, lifting, transporting, etc. It is difficult to work with (e.g. connection). | Low unit weight reduces the cost comparatively. Ease of construction (e.g. connection). | |
Research possibilities | In the advanced stages at present. | More possibilities as the concept is relatively new and material finds wide variety of applications. |
Annealing, also described in the earlier section, is part of the manufacturing process of cold-formed steel sheet. It is a heat treatment technique that alters the microstructure of the cold-reducing steel to recover its ductility.
The Direct Strength Method (DSM) is an alternative method of design located in Appendix 1 of the North American Specification for the Design of Cold-formed Steel Structural Members 2007 (AISI S100-07). DSM may be used in lieu of the Main Specification for determining nominal member capacities. Specific advantages include the absence of effective width and iterations, while only using known gross-sectional properties. An increase in prediction confidence stems from forced compatibility between section flanges and web throughout elastic buckling analysis. This increase in prediction accuracy for any section geometry provides a solid basis for rational analysis extension and encourages cross-sectional optimization. Either DSM or the main specification can be used with confidence as the Φ or Ω factors have been designed to insure that both methods are accurate. Currently, DSM only provides solutions for beams and columns and has to be used in conjunction with the main specification for a complete design.
Rational analysis is permitted when using optimized cold form shapes that are outside of the scope of the main specification and are not pre-qualified for DSM use. These non-pre-qualified sections use the factors of safety of ϕ and Ω associated with rational analysis (see AISI 2001 Section A1.1 (b)). The result of the rational analysis times the appropriate factor of safety will be used as the design strength of the section.
Several situations may exist where a rational analysis application of DSM can be used. In general these would include: (1) determining the elastic buckling values and (2) using the DSM equations in Appendix 1 to determine nominal flexural and axial capacities, Mn and Pn. The premise of DSM itself is an example of rational analysis. It uses elastic buckling results to determine the ultimate strength through the use of empirical strength curves. This provides designers with a method for performing a rational analysis in a number of unique situations.
In some cases the rational analysis extension to DSM may be as simple as dealing with an observed buckling mode that is difficult to identify and making a judgment call as to how to categorize the mode. But it could also be used to allow an engineer to include the effects of moment gradients, the influence of different end conditions, or the influence of torsion warping on all buckling modes.
There are currently no provisions within the DSM that pertain to shear, web crippling, holes in members, or strength increases due to the cold work of forming. Research on several of these topics has been completed or is in the process of being completed and should be included in the next update of the AISI Specification. DSM is also limited in determining strength for sections in which very slender elements are used. This is due to the strength of a cross section being predicted as a whole with DSM instead of using the effective width method of the specification which breaks the cross section up into several effective elements. One slender element will cause low strength with DSM, which is not the case with the current specification method. The finite strip method using CUFSM is the most commonly used approach to determine the elastic buckling loads. The program also limits DSM because holes cannot be considered, loads have to be uniform along the member, only simply supported boundary conditions are considered, and the buckling modes interact and cannot be easily distinguishable in some cases.
Reinforced concrete, also called ferroconcrete, is a composite material in which concrete's relatively low tensile strength and ductility are compensated for by the inclusion of reinforcement having higher tensile strength or ductility. The reinforcement is usually, though not necessarily, steel reinforcing bars and is usually embedded passively in the concrete before the concrete sets. However, post-tensioning is also employed as a technique to reinforce the concrete. In terms of volume used annually, it is one of the most common engineering materials. In corrosion engineering terms, when designed correctly, the alkalinity of the concrete protects the steel rebar from corrosion.
Rebar, known when massed as reinforcing steel or steel reinforcement, is a tension device added to concrete to form reinforced concrete and reinforced masonry structures to strengthen and aid the concrete under tension. Concrete is strong under compression, but has low tensile strength. Rebar usually consists of steel bars which significantly increase the tensile strength of the structure. Rebar surfaces feature a continuous series of ribs, lugs or indentations to promote a better bond with the concrete and reduce the risk of slippage.
Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. The condition may refer to a degree of loading or other actions on the structure, while the criteria refer to structural integrity, fitness for use, durability or other design requirements. A structure designed by LSD is proportioned to sustain all actions likely to occur during its design life, and to remain fit for use, with an appropriate level of reliability for each limit state. Building codes based on LSD implicitly define the appropriate levels of reliability by their prescriptions.
A structural insulated panel, or structural insulating panel, (SIP), is a form of sandwich panel used as a building material in the construction industry.
Seismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries and late 1970s for many other parts of the world, many structures were designed without adequate detailing and reinforcement for seismic protection. In view of the imminent problem, various research work has been carried out. State-of-the-art technical guidelines for seismic assessment, retrofit and rehabilitation have been published around the world – such as the ASCE-SEI 41 and the New Zealand Society for Earthquake Engineering (NZSEE)'s guidelines. These codes must be regularly updated; the 1994 Northridge earthquake brought to light the brittleness of welded steel frames, for example.
A joist is a horizontal structural member used in framing to span an open space, often between beams that subsequently transfer loads to vertical members. When incorporated into a floor framing system, joists serve to provide stiffness to the subfloor sheathing, allowing it to function as a horizontal diaphragm. Joists are often doubled or tripled, placed side by side, where conditions warrant, such as where wall partitions require support.
Framing, in construction, is the fitting together of pieces to give a structure, particularly a building, support and shape. Framing materials are usually wood, engineered wood, or structural steel. The alternative to framed construction is generally called mass wall construction, where horizontal layers of stacked materials such as log building, masonry, rammed earth, adobe, etc. are used without framing.
An I-beam is any of various structural members with an Ɪ- or H-shaped cross-section. Technical terms for similar items include H-beam, I-profile, universal column (UC), w-beam, universal beam (UB), rolled steel joist (RSJ), or double-T. I-beams are typically made of structural steel and serve a wide variety of construction uses.
Steel frame is a building technique with a "skeleton frame" of vertical steel columns and horizontal I-beams, constructed in a rectangular grid to support the floors, roof and walls of a building which are all attached to the frame. The development of this technique made the construction of the skyscraper possible. Steel frame has displaced its predecessor, the iron frame, in the early 20th century.
Structural steel is a category of steel used for making construction materials in a variety of shapes. Many structural steel shapes take the form of an elongated beam having a profile of a specific cross section. Structural steel shapes, sizes, chemical composition, mechanical properties such as strengths, storage practices, etc., are regulated by standards in most industrialized countries.
Glass fiber reinforced concrete (GFRC) is a type of fiber-reinforced concrete. The product is also known as glassfibre reinforced concrete or GRC in British English. Glass fiber concretes are mainly used in exterior building façade panels and as architectural precast concrete. Somewhat similar materials are fiber cement siding and cement boards.
A steel building is a metal structure fabricated with steel for the internal support and for exterior cladding, as opposed to steel framed buildings which generally use other materials for floors, walls, and external envelope. Steel buildings are used for a variety of purposes including storage, work spaces and living accommodation. They are classified into specific types depending on how they are used.
Steel Design, or more specifically, Structural Steel Design, is an area of structural engineering used to design steel structures. These structures include schools, houses, bridges, commercial centers, tall buildings, warehouses, aircraft, ships and stadiums. The design and use of steel frames are commonly employed in the design of steel structures. More advanced structures include steel plates and shells.
A steel plate shear wall (SPSW) consists of steel infill plates bounded by boundary elements.
In solid mechanics and structural engineering, section modulus is a geometric property of a given cross-section used in the design of beams or flexural members. Other geometric properties used in design include: area for tension and shear, radius of gyration for compression, and second moment of area and polar second moment of area for stiffness. Any relationship between these properties is highly dependent on the shape in question. There are two types of section modulus, elastic and plastic:
In structural engineering, the open web steel joist (OWSJ) is a lightweight steel truss consisting, in the standard form, of parallel chords and a triangulated web system, proportioned to span between bearing points.
Self-framing metal buildings are a form of pre-engineered building which utilizes roll formed roof and wall panel diaphragms as significant parts of the structural supporting system. Additional structural elements may include mill or cold-formed elements to stiffen the diaphragm perimeters, transfer forces between diaphragms and provide appropriate. As with most pre-engineered buildings, each building will be supplied with all necessary component parts to form a complete building system.
A buckling-restrained brace (BRB) is a structural brace in a building, designed to allow the building to withstand cyclical lateral loadings, typically earthquake-induced loading. It consists of a slender steel core, a concrete casing designed to continuously support the core and prevent buckling under axial compression, and an interface region that prevents undesired interactions between the two. Braced frames that use BRBs – known as buckling-restrained braced frames, or BRBFs – have significant advantages over typical braced frames.
Moment-resisting frame is a rectilinear assemblage of beams and columns, with the beams rigidly connected to the columns.
This glossary of structural engineering terms pertains specifically to structural engineering and its sub-disciplines. Please see glossary of engineering for a broad overview of the major concepts of engineering.