Diffusive gradients in thin films

Last updated

The diffusive gradients in thin films (DGT) technique is an environmental chemistry technique for the detection of elements and compounds in aqueous environments, including natural waters, [1] sediments [2] and soils. [3] It is well suited to in situ detection of bioavailable toxic trace metal contaminants. [4] [5] [6] The technique involves using a specially-designed passive sampler that houses a binding gel, diffusive gel and membrane filter. The element or compound passes through the membrane filter and diffusive gel and is assimilated by the binding gel in a rate-controlled manner. Post-deployment analysis of the binding gel can be used to determine the time-weighted-average bulk solution concentration of the element or compound via a simple equation.

Contents

According to DGT theory, the concentration of an analyte, [C], tends toward 0 (mg/L, ng/L, etc.) as the analyte approaches the binding layer, passing through the diffusive boundary layer (DBL, [?]) and the DGT device's diffusive gel (thickness of Dg). No reverse diffusion of the analyte back into the solution is assumed to occur. DGT theory.png
According to DGT theory, the concentration of an analyte, [C], tends toward 0 (μg/L, ng/L, etc.) as the analyte approaches the binding layer, passing through the diffusive boundary layer (DBL, ẟ) and the DGT device's diffusive gel (thickness of Δg). No reverse diffusion of the analyte back into the solution is assumed to occur.

History

The DGT technique was developed in 1994 by Hao Zhang and William Davison at the Lancaster Environment Centre of Lancaster University in the United Kingdom. The technique was first used to detect metal cations in marine environments using Chelex 100 as the binding agent. Further characterisation of DGT, including the results of field deployments in the Menai Strait and the North Atlantic Ocean, was published in 1995. [7] The technique was first tested in soils in 1998, with results demonstrating that kinetics of dissociation of labile species in the porewater (soil solution) could be determined via DGT. [8] Since then, the DGT technique has been modified and expanded to include a significant number of elements and compounds, including cationic metals, [7] nitrate, [9] phosphate and other oxyanions (V, CrVI, As, Se, Mo, Sb, W), [2] [10] [11] [12] [13] [14] antibiotics, [15] bisphenols, [16] and nanoparticles, [17] and has even been modified for the geochemical exploration of gold. [18] DGT has also been developed and calibrated for the measure of radionuclides, including for the analysis of actinides such as U, Pu, Am and Cm, both in the environment [19] and even in cooling pools for spent nuclear fuel rods. [20]

DGT Research Ltd. was established in July 1997 by the original developers of the technique, Profs. Davison and Zhang, and sells ready-made DGT® devices for water, soil and sediment deployments to measure different analytes, as well as the component parts for self-assembly. The company holds the original patents for the device and DGT® is a trademark which is registered throughout the world. In 2014 a rival company "EasySensor" was set up by Prof. Shiming Ding and supplies devices that the company claims are analogous to the original DGT® products. [21]

The DGT device

A photo of a disassembled DGT device, showing piston and cap. The device in this picture has been fitted with activated carbon for assimilating gold and/or bisphenols. DGT device.jpg
A photo of a disassembled DGT device, showing piston and cap. The device in this picture has been fitted with activated carbon for assimilating gold and/or bisphenols.

The most commonly used DGT device is a plastic "piston-type" probe, and comprises a cylindrical polycarbonate base and a tight-fitting, circular cap with an opening (DGT window). A binding gel, diffusive gel and filter membrane are stacked onto the base, and the cap is used to seal the gel and filter layers inside [4] :4.2.3 Dimensions of the gel layers vary depending on features of the environment, such as the flow rate of water being sampled; [4] :4.2.1 an example is an approximately 2 cm device diameter containing a 1mm gel layer. [22] Other commonly used probe configurations include those for deploying in sediments (to measure solute mobilisation with depth) [23] and in planar form for measuring solute dynamics in the plant rhizosphere. [24]

Principles of operation

Deployment

DGT devices being deployed into groundwater in the Tanami Desert, Australia. DGT deployed borehole.jpg
DGT devices being deployed into groundwater in the Tanami Desert, Australia.

DGT devices can be directly deployed in aqueous environmental media, including natural waters, sediments, and soils. [1] In fast-flowing waters, the DGT device's face should be perpendicular to the direction of flow, in order to ensure the diffusive boundary layer (DBL) is not affected by laminar flow. In slow-flowing or stagnant waters such as in ponds or groundwater, deployment of DGT devices with different thicknesses of diffusive gel can allow for the determination of the DBL and a more accurate determination of bulk concentration. [4] :4.2.1 [25] [9] Modifications to the diffusive gel (e.g. increasing or decreasing the thickness) can also be undertaken to ensure low detection limits. [26]

Analysis of binding gels and chemical imaging

After the DGT devices/probes have been retrieved, the binding gels can be eluted using methods that depend on the target analyte and the DGT binding gel (for example, nitric acid can be used to elute most metal cations from Chelex-100 gels). [4] :4.2.1 NaOH can be used to elute most oxyanions from Zr-Oxide(Ding et al., 2010, 2011,2016; Sun et al.,2014).The eluent can then be quantitatively analysed via a range of analytical techniques, including but not limited to: ICP-MS, GFAAS [4] :4.2.1 ICP-OES, AAS, [22] UV-Vis spectroscopy or computer imaging densitometry. [27] For chemical imaging and to obtain two-dimensional (2D) sub-mm high resolution distribution of analytes in heterogenous environments, such as sediments and the rhizosphere, the retrieved gel strips can be analyzed by PIXE or LA-ICP-MS after gel drying. [12] [28] [29] [30] [31]

The DGT equation

DGT is based on the application of Fick's law. [22] Once the mass of an analyte has been determined, the time-averaged concentration of the analyte in the bulk, , can be determined by application of the following equation:

where is the mass of the analyte on the resin, is the thickness of the diffusive layer and filter membrane together, is the diffusion coefficient of the analyte, is the deployment time, and is the area of the DGT window. [4] :Eq.2 More elaborate analysis techniques may be required in cases where the ionic strength of the water is low and where significant organic matter is present. [32]

See also

Related Research Articles

In chemical analysis, chromatography is a laboratory technique for the separation of a mixture into its components. The mixture is dissolved in a fluid solvent called the mobile phase, which carries it through a system on which a material called the stationary phase is fixed. Because the different constituents of the mixture tend to have different affinities for the stationary phase and are retained for different lengths of time depending on their interactions with its surface sites, the constituents travel at different apparent velocities in the mobile fluid, causing them to separate. The separation is based on the differential partitioning between the mobile and the stationary phases. Subtle differences in a compound's partition coefficient result in differential retention on the stationary phase and thus affect the separation.

<span class="mw-page-title-main">High-performance liquid chromatography</span> Technique in analytical chemistry

High-performance liquid chromatography (HPLC), formerly referred to as high-pressure liquid chromatography, is a technique in analytical chemistry used to separate, identify, and quantify specific components in mixtures. The mixtures can originate from food, chemicals, pharmaceuticals, biological, environmental and agriculture, etc., which have been dissolved into liquid solutions.

A biosensor is an analytical device, used for the detection of a chemical substance, that combines a biological component with a physicochemical detector. The sensitive biological element, e.g. tissue, microorganisms, organelles, cell receptors, enzymes, antibodies, nucleic acids, etc., is a biologically derived material or biomimetic component that interacts with, binds with, or recognizes the analyte under study. The biologically sensitive elements can also be created by biological engineering. The transducer or the detector element, which transforms one signal into another one, works in a physicochemical way: optical, piezoelectric, electrochemical, electrochemiluminescence etc., resulting from the interaction of the analyte with the biological element, to easily measure and quantify. The biosensor reader device connects with the associated electronics or signal processors that are primarily responsible for the display of the results in a user-friendly way. This sometimes accounts for the most expensive part of the sensor device, however it is possible to generate a user friendly display that includes transducer and sensitive element. The readers are usually custom-designed and manufactured to suit the different working principles of biosensors.

Capillary electrophoresis (CE) is a family of electrokinetic separation methods performed in submillimeter diameter capillaries and in micro- and nanofluidic channels. Very often, CE refers to capillary zone electrophoresis (CZE), but other electrophoretic techniques including capillary gel electrophoresis (CGE), capillary isoelectric focusing (CIEF), capillary isotachophoresis and micellar electrokinetic chromatography (MEKC) belong also to this class of methods. In CE methods, analytes migrate through electrolyte solutions under the influence of an electric field. Analytes can be separated according to ionic mobility and/or partitioning into an alternate phase via non-covalent interactions. Additionally, analytes may be concentrated or "focused" by means of gradients in conductivity and pH.

<span class="mw-page-title-main">Column chromatography</span> Method to isolate a compound in a mixture

Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential adsorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions. The technique is widely applicable, as many different adsorbents can be used with a wide range of solvents. The technique can be used on scales from micrograms up to kilograms. The main advantage of column chromatography is the relatively low cost and disposability of the stationary phase used in the process. The latter prevents cross-contamination and stationary phase degradation due to recycling. Column chromatography can be done using gravity to move the solvent, or using compressed gas to push the solvent through the column.

<span class="mw-page-title-main">Ion chromatography</span> Separates ions and polar molecules

Ion chromatography is a form of chromatography that separates ions and ionizable polar molecules based on their affinity to the ion exchanger. It works on almost any kind of charged molecule—including small inorganic anions, large proteins, small nucleotides, and amino acids. However, ion chromatography must be done in conditions that are one pH unit away from the isoelectric point of a protein.

<span class="mw-page-title-main">Surface plasmon resonance</span> Physical phenomenon of electron resonance

Surface plasmon resonance (SPR) is a phenomenon that occurs where electrons in a thin metal sheet become excited by light that is directed to the sheet with a particular angle of incidence, and then travel parallel to the sheet. Assuming a constant light source wavelength and that the metal sheet is thin, the angle of incidence that triggers SPR is related to the refractive index of the material and even a small change in the refractive index will cause SPR to not be observed. This makes SPR a possible technique for detecting particular substances (analytes) and SPR biosensors have been developed to detect various important biomarkers.

<span class="mw-page-title-main">Matrix-assisted laser desorption/ionization</span> Ionization technique

In mass spectrometry, matrix-assisted laser desorption/ionization (MALDI) is an ionization technique that uses a laser energy-absorbing matrix to create ions from large molecules with minimal fragmentation. It has been applied to the analysis of biomolecules and various organic molecules, which tend to be fragile and fragment when ionized by more conventional ionization methods. It is similar in character to electrospray ionization (ESI) in that both techniques are relatively soft ways of obtaining ions of large molecules in the gas phase, though MALDI typically produces far fewer multi-charged ions.

A ChemFET is a chemically-sensitive field-effect transistor, that is a field-effect transistor used as a sensor for measuring chemical concentrations in solution. When the target analyte concentration changes, the current through the transistor will change accordingly. Here, the analyte solution separates the source and gate electrodes. A concentration gradient between the solution and the gate electrode arises due to a semi-permeable membrane on the FET surface containing receptor moieties that preferentially bind the target analyte. This concentration gradient of charged analyte ions creates a chemical potential between the source and gate, which is in turn measured by the FET.

<span class="mw-page-title-main">Molecular sensor</span>

A molecular sensor or chemosensor is a molecular structure that is used for sensing of an analyte to produce a detectable change or a signal. The action of a chemosensor, relies on an interaction occurring at the molecular level, usually involves the continuous monitoring of the activity of a chemical species in a given matrix such as solution, air, blood, tissue, waste effluents, drinking water, etc. The application of chemosensors is referred to as chemosensing, which is a form of molecular recognition. All chemosensors are designed to contain a signalling moiety and a recognition moiety, that is connected either directly to each other or through a some kind of connector or a spacer. The signalling is often optically based electromagnetic radiation, giving rise to changes in either the ultraviolet and visible absorption or the emission properties of the sensors. Chemosensors may also be electrochemically based. Small molecule sensors are related to chemosensors. These are traditionally, however, considered as being structurally simple molecules and reflect the need to form chelating molecules for complexing ions in analytical chemistry. Chemosensors are synthetic analogues of biosensors, the difference being that biosensors incorporate biological receptors such as antibodies, aptamers or large biopolymers.

Electrochromatography is a chemical separation technique in analytical chemistry, biochemistry and molecular biology used to resolve and separate mostly large biomolecules such as proteins. It is a combination of size exclusion chromatography and gel electrophoresis. These separation mechanisms operate essentially in superposition along the length of a gel filtration column to which an axial electric field gradient has been added. The molecules are separated by size due to the gel filtration mechanism and by electrophoretic mobility due to the gel electrophoresis mechanism. Additionally there are secondary chromatographic solute retention mechanisms.

<span class="mw-page-title-main">Desorption electrospray ionization</span>

Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples at atmospheric conditions. Coupled ionization sources-MS systems are popular in chemical analysis because the individual capabilities of various sources combined with different MS systems allow for chemical determinations of samples. DESI employs a fast-moving charged solvent stream, at an angle relative to the sample surface, to extract analytes from the surfaces and propel the secondary ions toward the mass analyzer. This tandem technique can be used to analyze forensics analyses, pharmaceuticals, plant tissues, fruits, intact biological tissues, enzyme-substrate complexes, metabolites and polymers. Therefore, DESI-MS may be applied in a wide variety of sectors including food and drug administration, pharmaceuticals, environmental monitoring, and biotechnology.

Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration, sample phase, and composition of the analyte solution. Quite possibly the most important consideration in sample preparation is knowing what phase the sample must be in for analysis to be successful. In some cases the analyte itself must be purified before entering the ion source. In other situations, the matrix, or everything in the solution surrounding the analyte, is the most important factor to consider and adjust. Often, sample preparation itself for mass spectrometry can be avoided by coupling mass spectrometry to a chromatography method, or some other form of separation before entering the mass spectrometer. In some cases, the analyte itself must be adjusted so that analysis is possible, such as in protein mass spectrometry, where usually the protein of interest is cleaved into peptides before analysis, either by in-gel digestion or by proteolysis in solution.

<span class="mw-page-title-main">Capillary electrophoresis–mass spectrometry</span>

Capillary electrophoresis–mass spectrometry (CE–MS) is an analytical chemistry technique formed by the combination of the liquid separation process of capillary electrophoresis with mass spectrometry. CE–MS combines advantages of both CE and MS to provide high separation efficiency and molecular mass information in a single analysis. It has high resolving power and sensitivity, requires minimal volume and can analyze at high speed. Ions are typically formed by electrospray ionization, but they can also be formed by matrix-assisted laser desorption/ionization or other ionization techniques. It has applications in basic research in proteomics and quantitative analysis of biomolecules as well as in clinical medicine. Since its introduction in 1987, new developments and applications have made CE-MS a powerful separation and identification technique. Use of CE–MS has increased for protein and peptides analysis and other biomolecules. However, the development of online CE–MS is not without challenges. Understanding of CE, the interface setup, ionization technique and mass detection system is important to tackle problems while coupling capillary electrophoresis to mass spectrometry.

<span class="mw-page-title-main">Ambient ionization</span>

Ambient ionization is a form of ionization in which ions are formed in an ion source outside the mass spectrometer without sample preparation or separation. Ions can be formed by extraction into charged electrospray droplets, thermally desorbed and ionized by chemical ionization, or laser desorbed or ablated and post-ionized before they enter the mass spectrometer.

<span class="mw-page-title-main">Affinity electrophoresis</span>

Affinity electrophoresis is a general name for many analytical methods used in biochemistry and biotechnology. Both qualitative and quantitative information may be obtained through affinity electrophoresis. Cross electrophoresis, the first affinity electrophoresis method, was created by Nakamura et al. Enzyme-substrate complexes have been detected using cross electrophoresis. The methods include the so-called electrophoretic mobility shift assay, charge shift electrophoresis and affinity capillary electrophoresis. The methods are based on changes in the electrophoretic pattern of molecules through biospecific interaction or complex formation. The interaction or binding of a molecule, charged or uncharged, will normally change the electrophoretic properties of a molecule. Membrane proteins may be identified by a shift in mobility induced by a charged detergent. Nucleic acids or nucleic acid fragments may be characterized by their affinity to other molecules. The methods have been used for estimation of binding constants, as for instance in lectin affinity electrophoresis or characterization of molecules with specific features like glycan content or ligand binding. For enzymes and other ligand-binding proteins, one-dimensional electrophoresis similar to counter electrophoresis or to "rocket immunoelectrophoresis", affinity electrophoresis may be used as an alternative quantification of the protein. Some of the methods are similar to affinity chromatography by use of immobilized ligands.

<span class="mw-page-title-main">Chemiresistor</span> Material with changing electrical resistance according to its surroundings

A chemiresistor is a material that changes its electrical resistance in response to changes in the nearby chemical environment. Chemiresistors are a class of chemical sensors that rely on the direct chemical interaction between the sensing material and the analyte. The sensing material and the analyte can interact by covalent bonding, hydrogen bonding, or molecular recognition. Several different materials have chemiresistor properties: semiconducting metal oxides, some conductive polymers, and nanomaterials like graphene, carbon nanotubes and nanoparticles. Typically these materials are used as partially selective sensors in devices like electronic tongues or electronic noses.

Surface plasmon resonance microscopy (SPRM), also called surface plasmon resonance imaging (SPRI), is a label free analytical tool that combines the surface plasmon resonance of metallic surfaces with imaging of the metallic surface. The heterogeneity of the refractive index of the metallic surface imparts high contrast images, caused by the shift in the resonance angle. SPRM can achieve a sub-nanometer thickness sensitivity and lateral resolution achieves values of micrometer scale. SPRM is used to characterize surfaces such as self-assembled monolayers, multilayer films, metal nanoparticles, oligonucleotide arrays, and binding and reduction reactions. Surface plasmon polaritons are surface electromagnetic waves coupled to oscillating free electrons of a metallic surface that propagate along a metal/dielectric interface. Since polaritons are highly sensitive to small changes in the refractive index of the metallic material, it can be used as a biosensing tool that does not require labeling. SPRM measurements can be made in real-time, such as measuring binding kinetics of membrane proteins in single cells, or DNA hybridization.

<span class="mw-page-title-main">Passive sampling</span>

Passive sampling is an environmental monitoring technique involving the use of a collecting medium, such as a man-made device or biological organism, to accumulate chemical pollutants in the environment over time. This is in contrast to grab sampling, which involves taking a sample directly from the media of interest at one point in time. In passive sampling, average chemical concentrations are calculated over a device's deployment time, which avoids the need to visit a sampling site multiple times to collect multiple representative samples. Currently, passive samplers have been developed and deployed to detect toxic metals, pesticides, pharmaceuticals, radionuclides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and other organic compounds in water, while some passive samplers can detect hazardous substances in the air.

A chemical sensor array is a sensor architecture with multiple sensor components that create a pattern for analyte detection from the additive responses of individual sensor components. There exist several types of chemical sensor arrays including electronic, optical, acoustic wave, and potentiometric devices. These chemical sensor arrays can employ multiple sensor types that are cross-reactive or tuned to sense specific analytes.

References

  1. 1 2 Chaudhary M, Quanz M, Williams J, Maltby E, Oakes K, Spooner I, Walker TR (September 2020). "Assessment of metal(loid) concentrations using Diffusive Gradient Thin (DGT) films in marine, freshwater and wetland aquatic ecosystems impacted by industrial effluents". Case Studies in Chemical and Environmental Engineering. 2: 100041. doi: 10.1016/j.cscee.2020.100041 .
  2. 1 2 Zhang H, Davison W, Gadi R, Kobayashi T (August 1998). "In situ measurement of dissolved phosphorus in natural waters using DGT". Analytica Chimica Acta. 370 (1): 29–38. doi:10.1016/S0003-2670(98)00250-5.
  3. Wilkins CL (October 1983). "Hyphenated techniques for analysis of complex organic mixtures". Science. 222 (4621): 291–6. Bibcode:1983Sci...222..291W. doi:10.1126/science.6353577. PMID   6353577.
  4. 1 2 3 4 5 6 7 "Diffusive Gradients in Thin-films (DGT): A Technique for Determining Bioavailable Metal Concentrations" (PDF). International Network for Acid Prevention. March 2002. Archived from the original (PDF) on 28 February 2015. Retrieved 23 April 2015.
  5. Strivens J, Hayman N, Johnston R, Rosen G (May 2019). "Effects of Dissolved Organic Carbon on Copper Toxicity to Embryos of Mytilus galloprovincialis as Measured by Diffusive Gradient in Thin Films". Environmental Toxicology and Chemistry. 38 (5): 1029–1034. doi:10.1002/etc.4404. PMID   30840314. S2CID   73466599.
  6. Strivens J, Hayman N, Rosen G, Myers-Pigg A (April 2020). "Toward Validation of Toxicological Interpretation of Diffusive Gradients in Thin Films in Marine Waters Impacted by Copper". Environmental Toxicology and Chemistry. 39 (4): 873–881. doi:10.1002/etc.4673. PMID   32004383.
  7. 1 2 Zhang H, Davison W (October 1995). "Performance Characteristics of Diffusion Gradients in Thin Films for the in Situ Measurement of Trace Metals in Aqueous Solution". Analytical Chemistry. 67 (19): 3391–3400. doi:10.1021/ac00115a005.
  8. Harper MP, Davison W, Zhang H, Tych W (August 1998). "Kinetics of metal exchange between solids and solutions in sediments and soils interpreted from DGT measured fluxes". Geochimica et Cosmochimica Acta. 62 (16): 2757–2770. Bibcode:1998GeCoA..62.2757H. doi:10.1016/S0016-7037(98)00186-0.
  9. 1 2 Corbett, Thomas D. W.; Dougherty, Hannah; Maxwell, Bryan; Hartland, Adam; Henderson, William; Rys, Gerald J.; Schipper, Louis A. (2020-05-20). "Utility of 'Diffusive Gradients in Thin-Films' for the measurement of nitrate removal performance of denitrifying bioreactors". Science of the Total Environment. 718: 135267. doi:10.1016/j.scitotenv.2019.135267. ISSN   0048-9697. PMID   31859060. S2CID   209425982.
  10. Santner J, Prohaska T, Luo J, Zhang H (September 2010). "Ferrihydrite containing gel for chemical imaging of labile phosphate species in sediments and soils using diffusive gradients in thin films". Analytical Chemistry. 82 (18): 7668–74. doi:10.1021/ac101450j. PMC   3432420 . PMID   20735010.
  11. Luo J, Zhang H, Santner J, Davison W (November 2010). "Performance characteristics of diffusive gradients in thin films equipped with a binding gel layer containing precipitated ferrihydrite for measuring arsenic(V), selenium(VI), vanadium(V), and antimony(V)". Analytical Chemistry. 82 (21): 8903–9. doi:10.1021/ac101676w. PMID   20936784.
  12. 1 2 Guan DX, Williams PN, Luo J, Zheng JL, Xu HC, Cai C, Ma LQ (March 2015). "Novel precipitated zirconia-based DGT technique for high-resolution imaging of oxyanions in waters and sediments". Environmental Science & Technology. 49 (6): 3653–61. Bibcode:2015EnST...49.3653G. doi:10.1021/es505424m. PMID   25655234.
  13. Stockdale A, Davison W, Zhang H (April 2010). "2D simultaneous measurement of the oxyanions of P, V, As, Mo, Sb, W and U" (PDF). Journal of Environmental Monitoring. 12 (4): 981–4. doi:10.1039/b925627j. PMID   20383381.
  14. Pan Y, Guan DX, Zhao D, Luo J, Zhang H, Davison W, Ma LQ (December 2015). "Novel Speciation Method Based on Diffusive Gradients in Thin-Films for in Situ Measurement of Cr(VI) in Aquatic Systems". Environmental Science & Technology. 49 (24): 14267–73. Bibcode:2015EnST...4914267P. doi:10.1021/acs.est.5b03742. PMID   26535488.
  15. Chen CE, Zhang H, Jones KC (May 2012). "A novel passive water sampler for in situ sampling of antibiotics". Journal of Environmental Monitoring. 14 (6): 1523–30. doi:10.1039/c2em30091e. PMID   22538362.
  16. Zheng JL, Guan DX, Luo J, Zhang H, Davison W, Cui XY, et al. (January 2015). "Activated charcoal based diffusive gradients in thin films for in situ monitoring of bisphenols in waters". Analytical Chemistry. 87 (1): 801–7. doi:10.1021/ac503814j. PMID   25412473.
  17. Pouran HM, Martin FL, Zhang H (June 2014). "Measurement of ZnO nanoparticles using diffusive gradients in thin films: binding and diffusional characteristics". Analytical Chemistry. 86 (12): 5906–13. doi:10.1021/ac500730s. hdl: 2436/621804 . PMID   24831848.
  18. Lucas A, Rate A, Zhang H, Salmon SU, Radford N (August 2012). "Development of the diffusive gradients in thin films technique for the measurement of labile gold in natural waters". Analytical Chemistry. 84 (16): 6994–7000. doi:10.1021/ac301003g. PMID   22812590.
  19. Chaplin J, Warwick P, Cundy A, Bochud F, Froidevaux P (25 August 2021). "Novel DGT Configurations for the Assessment of Bioavailable Plutonium, Americium, and Uranium in Marine and Freshwater Environments". Analytical Chemistry. 93 (35): 11937–11945. doi: 10.1021/acs.analchem.1c01342 . PMID   34432435. S2CID   237307309.
  20. Chaplin J, Christl M, Straub M, Bochud F, Froidevaux P (2 June 2022). "Passive Sampling Tool for Actinides in Spent Nuclear Fuel Pools". ACS Omega. 7 (23): 20053−20058. doi:10.1021/acsomega.2c01884. hdl: 20.500.11850/554631 . PMC   9202248 . PMID   35722008. S2CID   249333570.
  21. "global-easysensor.com". Archived from the original on 2020-08-08.
  22. 1 2 3 Thomas P (1 July 2009). "Metals pollution tracing in the sewerage network using the diffusive gradients in thin films technique". Water Science and Technology. 60 (1): 65–70. doi:10.2166/wst.2009.287. PMID   19587403.
  23. Zhang H, Davison W, Miller S, Tych W (1995-10-01). "In situ high resolution measurements of fluxes of Ni, Cu, Fe, and Mn and concentrations of Zn and Cd in porewaters by DGT". Geochimica et Cosmochimica Acta. 59 (20): 4181–4192. Bibcode:1995GeCoA..59.4181Z. doi:10.1016/0016-7037(95)00293-9. ISSN   0016-7037.
  24. Williams PN, Santner J, Larsen M, Lehto NJ, Oburger E, Wenzel W, et al. (2014-08-05). "Localized flux maxima of arsenic, lead, and iron around root apices in flooded lowland rice". Environmental Science & Technology. 48 (15): 8498–506. Bibcode:2014EnST...48.8498W. doi:10.1021/es501127k. PMC   4124062 . PMID   24967508.
  25. Warnken KW, Zhang H, Davison W (June 2006). "Accuracy of the diffusive gradients in thin-films technique: diffusive boundary layer and effective sampling area considerations". Analytical Chemistry. 78 (11): 3780–7. doi:10.1021/ac060139d. PMID   16737237.
  26. Lucas AR, Reid N, Salmon SU, Rate AW (October 2014). "Quantitative assessment of the distribution of dissolved Au, As and Sb in groundwater using the diffusive gradients in thin films technique". Environmental Science & Technology. 48 (20): 12141–9. Bibcode:2014EnST...4812141L. doi:10.1021/es502468d. PMID   25252140.
  27. McGifford RW, Seen AJ, Haddad PR (March 2010). "Direct colorimetric detection of copper(II) ions in sampling using diffusive gradients in thin-films". Analytica Chimica Acta. 662 (1): 44–50. doi:10.1016/j.aca.2009.12.041. PMID   20152264.
  28. Davison W, Fones GR, Grime GW (June 1997). "Dissolved metals in surface sediment and a microbial mat at 100-μm resolution". Nature. 387 (6636): 885–888. Bibcode:1997Natur.387..885D. doi: 10.1038/43147 . S2CID   4261454.
  29. Warnken KW, Zhang H, Davison W (October 2004). "Analysis of polyacrylamide gels for trace metals using diffusive gradients in thin films and laser ablation inductively coupled plasma mass spectrometry". Analytical Chemistry. 76 (20): 6077–84. doi:10.1021/ac0400358. PMID   15481956.
  30. Williams PN, Santner J, Larsen M, Lehto NJ, Oburger E, Wenzel W, et al. (5 August 2014). "Localized flux maxima of arsenic, lead, and iron around root apices in flooded lowland rice". Environmental Science & Technology. 48 (15): 8498–506. Bibcode:2014EnST...48.8498W. doi:10.1021/es501127k. PMC   4124062 . PMID   24967508.
  31. Hoefer C, Santner J, Puschenreiter M, Wenzel WW (April 2015). "Localized metal solubilization in the rhizosphere of Salix smithiana upon sulfur application". Environmental Science & Technology. 49 (7): 4522–9. Bibcode:2015EnST...49.4522H. doi:10.1021/es505758j. PMC   4394708 . PMID   25782052.
  32. Yabuki LN, Colaço CD, Menegário AA, Domingos RN, Kiang CH, Pascoaloto D (February 2014). "Evaluation of diffusive gradients in thin films technique (DGT) for measuring Al, Cd, Co, Cu, Mn, Ni, and Zn in Amazonian rivers". Environmental Monitoring and Assessment. 186 (2): 961–9. doi:10.1007/s10661-013-3430-x. PMID   24052239. S2CID   9781883.