Electromagnetic articulography

Last updated

Midsagittal view of the human mouth. Transducer (sensor) coils are typically placed on the tongue and lips. Illu01 head neck.jpg
Midsagittal view of the human mouth. Transducer (sensor) coils are typically placed on the tongue and lips.

Electromagnetic articulography (EMA) is a method of measuring the position of parts of the mouth. EMA uses sensor coils placed on the tongue and other parts of the mouth to measure their position and movement over time during speech and swallowing. Induction coils around the head produce an electromagnetic field that creates, or induces, a current in the sensors in the mouth. Because the current induced is inversely proportional to the cube of the distance, a computer is able to analyse the current produced and determine the sensor coil's location in space.

Contents

EMA is used in linguistics and speech pathology to study articulation and in medicine to study oropharyngeal dysphagia. Other methods have been used to study articulation and ingestion with tradeoffs in the kind and amount of data available. Palatography allows the study of articulations that make contact with the palate such as some lingual consonants, but unlike EMA, palatographs cannot provide data on sounds which do not make contact such as vowels. Fluoroscopy and X-ray microbeam allow the investigation of non-contact movements of the mouth like EMA, but expose subjects to ionizing radiation which limits the amount of data that can be collected from a given participant.

Principles of operation

The ability to observe the movements of articulators has been of great importance to the study of phonetics in order to understand the way sounds are produced. [1]

Electromagnetic articulography uses the principle of electromagnetic induction to measure the position and movement of various points in and around the mouth. A helmet containing electromagnetic transmitters creates a variable magnetic field by running currents through the transmitters at different frequencies. Sensor coils placed midsagittally in the mouth produce current as they move through the magnetic field inversely proportional to the cube of the distance from the transmitters. [2] The current induced alternates at the same frequency as the transmitter coil and the composite signal can be separated out to determine the distance from each individual coil, thus determining the position of the sensor in space. [3] [4]

In two-dimensional articulography, transmitter coils are placed in an equilateral triangle along the midsagittal plane at the forehead, chin, and neck. [2] Because of the geometric orientation of the transmitter coils, accurate readings are able to be taken as long as the sensor coils placed on the tongue stay within about a centimeter of the midsagittal plane and are not angled at more than 30 degrees. [4]

Articulographs able to measure in three dimensions use six transmitter coils organized in a spherical configuration. The transmitters are arranged so that the axis of a sensor coil is never perpendicular to more than three transmitters. Through the transmitter configuration and ability to measure in multiple dimensions, three-dimensional articulographs are able to make measurements outside of the midsagittal plane. 2D articulographs require restrictive headmounts to ensure that the subject's head does not move off the plane of measurement. Because 3D articulographs are able to measure outside of the midsagittal plane, a less restrictive headmount is able to be used. [5]

Development of two and three dimensional sensors

Thomas Hixon was the first to describe the use of electromagnetic principles to measure articulation. In his 1971 letter to the editor, published in The Journal of the Acoustical Society of America, he described a setup using two sensor coils and one generator coil. The sensor coils, attached to the forehead and back of the neck, would remain stationary while the generator coil, attached to the jaw, would move creating variable currents in the sensor coils. These currents could then be used to determine the distance in two dimensions. [6]

Early EMA systems like Hixon's had problems with accounting for tilting of the tongue during use as tilting of the sensor coils causes changes in the induced current that can skew data. [1] In 1987, Paul Schönle et al. published an improved system that used three transmitter coils (analogous to Hixon's generator coil) and computer software to triangulate the position of sensor coils and account for tilt. [1] However modern two-dimensional systems are still unable to compensate for tilting of sensors past 30 degrees and measurement is distorted if sensor coils are moved off the centerline of the mouth. [2] [4] In 1993, Andreas Zierdt published a description of an articulograph that would be able to measure movement in three dimensions, though three dimensional articulographs have only been commercially available since around 2009. [5] Zierdt's conceptualization placed six transmitter coils equidistant from each other. Because sensor coils are dipoles, when they are perpendicular to a transmitter coil the current induced is zero, so Zierdt angled the transmitter coils so that for any given rotation of a sensor coil, it was not perpendicular to more than three transmitter coils allowing for at least three transmitter coils to triangulate the position of the sensor. [5] [7]

Visualisation of the tongue motions of a trumpet player Trumpet Triple Tonguing Visualisation.tif
Visualisation of the tongue motions of a trumpet player

Effect on subjects

As sensor coils are placed on the tongue of the subject, articulation may be affected depending on the placement of the coils, but no comparative analysis has shown whether articulation is altered because of the coils. The coils are about 3 mm in size and are not considered to be a particularly large source of error for measurements. Some researchers have found that subjects are irritated by sensor coils placed on the tip of the tongue which can lead to disturbed articulation. Similarly, the wires attached to the sensor coils can inhibit articulation if not run out the side of the mouth. [8]

It has not been shown that long term exposure to electromagnetic fields is harmful to human health, but it is recommended to avoid subjects who are pregnant or who utilize pacemakers. Guidelines place the limit for safe continuous exposure between 100  μT and 200 μT. [9] The field and frequencies output by electromagnetic articulographs are comparable to those put out by computer terminals with the maximum measured being about 10 μT.

Alternative methods

Various diagnostic techniques preceded electromagnetic articulography.

Palatography and electropalatography

Palatography and electropalatography both measure contact of the tongue with the palate and thus are unable to measure articulations that do not make contact with the palate such as vowels. [10]

Palatography involves the painting of a colored substance onto the tongue which is then transferred onto the palate during articulation. A picture is then taken of the palate to record the location of contact and, if another palatogram is to be taken, the mouth is washed out and the tongue repainted. A particularly low cost method that is often used in fieldwork, it can be difficult to collect large amounts of data. [10] [11]

Electropalatography involves the use of a custom-fitted artificial palate containing electrodes that measure contact. While able to record multiple contacts, the artificial palate may obstruct or interfere with articulation, and each subject requires a custom-fitted palate. [12]

Video fluoroscopy

Video fluoroscopy uses X-ray radiation to produce moving pictures of the mouth during articulation or swallowing. It is considered the gold standard in studies of dysphagia because of its ability to take videos of the entire digestive tract during swallowing events. [13] It is often used to study and treat aspiration of food, what parts of the digestive tract are malfunctioning during swallowing, and positions in which swallowing is easiest. [14] Only limited data is able to be collected as sessions are typically limited to three minutes due to the hazards of radiation exposure. [4] [15] and it does not allow for fine grain analysis of tongue movements.

X-ray microbeam

Similar to video fluoroscopy, X-ray microbeam studies use radiation to study movements of articulators. Gold pellets, 2 to 3 mm in size, are placed in and around the mouth similar to the coils used in EMA. Radiation exposure is limited by using computer software to focus narrow X-ray beams, about 6 mm2, on the pellets and track them as they move. [16] Like EMA, X-ray microbeam studies are limited by the placement of the pellets. While able to minimize radiation exposure, the system is largely inaccessible as it is unique to the University of Wisconsin. [4] [16] [17]

Related Research Articles

<span class="mw-page-title-main">Ammeter</span> Device that measures electric current

An ammeter is an instrument used to measure the current in a circuit. Electric currents are measured in amperes (A), hence the name. For direct measurement, the ammeter is connected in series with the circuit in which the current is to be measured. An ammeter usually has low resistance so that it does not cause a significant voltage drop in the circuit being measured.

Phonetics is a branch of linguistics that studies how humans produce and perceive sounds or, in the case of sign languages, the equivalent aspects of sign. Linguists who specialize in studying the physical properties of speech are phoneticians. The field of phonetics is traditionally divided into three sub-disciplines based on the research questions involved such as how humans plan and execute movements to produce speech, how various movements affect the properties of the resulting sound or how humans convert sound waves to linguistic information. Traditionally, the minimal linguistic unit of phonetics is the phone—a speech sound in a language which differs from the phonological unit of phoneme; the phoneme is an abstract categorization of phones and it is also defined as the smallest unit that discerns meaning between sounds in any given language.

<span class="mw-page-title-main">Place of articulation</span> Place in the mouth consonants are articulated

In articulatory phonetics, the place of articulation of a consonant is a location along the vocal tract where its production occurs. It is a point where a constriction is made between an active and a passive articulator. Active articulators are organs capable of voluntary movement which create the constriction, while passive articulators are so called because they are normally fixed and are the parts with which an active articulator makes contact. Along with the manner of articulation and phonation, the place of articulation gives the consonant its distinctive sound.

Velars are consonants articulated with the back part of the tongue against the soft palate, the back part of the roof of the mouth.

<span class="mw-page-title-main">Galvanometer</span> Instrument to measure electric current

A galvanometer is an electromechanical measuring instrument for electric current. Early galvanometers were uncalibrated, but improved versions, called ammeters, were calibrated and could measure the flow of current more precisely. Galvanometers work by deflecting a pointer in response to an electric current flowing through a coil in a constant magnetic field. The mechanism is also used as an actuator in applications such as hard disks.

The field of articulatory phonetics is a subfield of phonetics that studies articulation and ways that humans produce speech. Articulatory phoneticians explain how humans produce speech sounds via the interaction of different physiological structures. Generally, articulatory phonetics is concerned with the transformation of aerodynamic energy into acoustic energy. Aerodynamic energy refers to the airflow through the vocal tract. Its potential form is air pressure; its kinetic form is the actual dynamic airflow. Acoustic energy is variation in the air pressure that can be represented as sound waves, which are then perceived by the human auditory system as sound.

<span class="mw-page-title-main">Magnetometer</span> Device that measures magnetism

A magnetometer is a device that measures magnetic field or magnetic dipole moment. Different types of magnetometers measure the direction, strength, or relative change of a magnetic field at a particular location. A compass is one such device, one that measures the direction of an ambient magnetic field, in this case, the Earth's magnetic field. Other magnetometers measure the magnetic dipole moment of a magnetic material such as a ferromagnet, for example by recording the effect of this magnetic dipole on the induced current in a coil.

A transducer is a device that converts energy from one form to another. Usually a transducer converts a signal in one form of energy to a signal in another. Transducers are often employed at the boundaries of automation, measurement, and control systems, where electrical signals are converted to and from other physical quantities. The process of converting one form of energy to another is known as transduction.

Measurement and signature intelligence (MASINT) is a technical branch of intelligence gathering, which serves to detect, track, identify or describe the distinctive characteristics (signatures) of fixed or dynamic target sources. This often includes radar intelligence, acoustic intelligence, nuclear intelligence, and chemical and biological intelligence. MASINT is defined as scientific and technical intelligence derived from the analysis of data obtained from sensing instruments for the purpose of identifying any distinctive features associated with the source, emitter or sender, to facilitate the latter's measurement and identification.

<span class="mw-page-title-main">Wireless power transfer</span> Transmission of electrical energy without wires as a physical link

Wireless power transfer (WPT), wireless power transmission, wireless energy transmission (WET), or electromagnetic power transfer is the transmission of electrical energy without wires as a physical link. In a wireless power transmission system, an electrically powered transmitter device generates a time-varying electromagnetic field that transmits power across space to a receiver device; the receiver device extracts power from the field and supplies it to an electrical load. The technology of wireless power transmission can eliminate the use of the wires and batteries, thereby increasing the mobility, convenience, and safety of an electronic device for all users. Wireless power transfer is useful to power electrical devices where interconnecting wires are inconvenient, hazardous, or are not possible.

<span class="mw-page-title-main">Ankyloglossia</span> Congenital disorder of tongue mobility

Ankyloglossia, also known as tongue-tie, is a congenital oral anomaly that may decrease the mobility of the tongue tip and is caused by an unusually short, thick lingual frenulum, a membrane connecting the underside of the tongue to the floor of the mouth. Ankyloglossia varies in degree of severity from mild cases characterized by mucous membrane bands to complete ankyloglossia whereby the tongue is tethered to the floor of the mouth.

Oral myology is the field of study that involves the evaluation and treatment of the oral and facial musculature, including the muscles of the tongue, lips, cheeks, and jaw.

<span class="mw-page-title-main">Current clamp</span> Tool for measuring electrical current

In electrical and electronic engineering, a current clamp, also known as current probe, is an electrical device with jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.

Electropalatography (EPG) is a technique used to monitor contacts between the tongue and hard palate, particularly during articulation and speech.

Velopharyngeal insufficiency is a disorder of structure that causes a failure of the velum to close against the posterior pharyngeal wall during speech in order to close off the nose during oral speech production. This is important because speech requires sound and airflow to be directed into the oral cavity (mouth) for the production of all speech sound with the exception of nasal sounds. If complete closure does not occur during speech, this can cause hypernasality and/or audible nasal emission during speech. In addition, there may be inadequate airflow to produce most consonants, making them sound weak or omitted.

An Electromagnetic Log, sometimes called an "EM log", is an electronic sensor which measures the speed of a vessel through sea water. Like many other technologies, its name derives from the traditional chip log. It makes use of Faraday's law of induction by measuring the EMF induced in water moving through a magnetic field generated by the sensor.

Radiofrequency coils are the receivers, and sometimes also the transmitters, of radiofrequency (RF) signals in equipment used in magnetic resonance imaging (MRI).

Fiber-optical thermometers can be used in electromagnetically strongly influenced environment, in microwave fields, power plants or explosion-proof areas and wherever measurement with electrical temperature sensors are not possible.

A lisp is a speech impairment in which a person misarticulates sibilants. These misarticulations often result in unclear speech in languages with phonemic sibilants.

<span class="mw-page-title-main">Pose tracking</span>

In virtual reality (VR) and augmented reality (AR), a pose tracking system detects the precise pose of head-mounted displays, controllers, other objects or body parts within Euclidean space. Pose tracking is often referred to as 6DOF tracking, for the six degrees of freedom in which the pose is often tracked.

References

  1. 1 2 3 Schönle, Paul; Klause Gräbe; Peter Wenig; Jörg Höhne; Jörg Schrader, and Bastian Conrad. 1987. Electromagnetic Articulography: Use of Alternating Magnetic Fields for Tracking Movements of Multiple Points Inside and Outside the Vocal Tract. Brain and Language 31. 2635. .
  2. 1 2 3 Zhang, Jie; Ian Maddieson; Taehong Cho, and Marco Baroni. 1999. Articulograph AG100 Electromagnetic Articulation Analyzer Homemade Manual UCLA Phonetics Lab . Web: UCLA. Accessed 9 July 2015.
  3. Maassen, Ben, and Pascal van Lieshout. 2010. Speech Motor Control: New Developments in Basic and Applied Research , 325. Oxford: Oxford University Press. Accessed 16 November 2015.
  4. 1 2 3 4 5 Steele, Catriona. 2004. Use of Electromagnetic Midsagittal Articulography in the Study of Swallowing. Journal of Speech, Language, and Hearing Research 47. 342352. .
  5. 1 2 3 Yunusova, Yana; Jordan Green, and Antje Mefferd. 2009. Accuracy Assessment for AG500, Electromagnetic Articulograph. Journal of Speech, Language, and Hearing Research 52. 547555. .
  6. Hixon, Thomas. 1971. An Electromagnetic Method for Transducing Jaw Movements during Speech. Acoustical Society of America 49. 603606. .
  7. Zierdt, Andreas. 1993. Problems of Electromagnetic Position Transduction for a Three-Dimensional Articulographic Measurement System. Institut für Phonetik und sprachliche Kommunikation der Universitat Munchen - Forschungsberichte 31. 137141. .
  8. Hardcastle, William; Hewlett, Nigel (2006), Coarticulation: Theory, Data, and Techniques, Cambridge Studies in Speech Science and Communication, Cambridge University Press
  9. Bernhardt, J.H.. 1988. The establishment of frequency dependent limits for electric and magnetic fields and evaluation of indirect effects. Radiation and Environmental Biophysics 27. 127. .
  10. 1 2 Anderson, Victoria; Patrick Barjam; Robert Bowen, and Katya Pertsova. 2003. Practical Points . (Static Palatography). Web: University of California Los Angeles Linguistics. Accessed 7 July 2015.
  11. Anderson, Victoria; Patrick Barjam; Robert Bowen, and Katya Pertsova. 2003. Palatograms . (Static Palatography). Web: University of California Los Angeles Linguistics. Accessed 7 July 2015.
  12. Toutios, Asterios, and Konstantinos Margaritis. 2005. On the acoustic-to-electropalatographic mapping. Nonlinear Analyses and Algorithms for Speech Processing ed. by Marcos Faundez-Zanuy, Léonard Janer, Anna Esposito, Antonio Satue-Villar, Josep Roure, and Virginia Espinosa-Duro, 186195. Barcelona, Spain: International Conference on Non-Linear Speech Processing.
  13. Olthoff, Arno; Shuo Zhang; Renate Schweizer, and Jens Frahm. 2014. On the Physiology of Normal Swallowing as Revealed by Magnetic Resonance Imaging in Real Time. Gastroenterology Research and Practice 2014. n.p.. .
  14. American Speech-Language-Hearing Association. n.d.. Videofluoroscopic Swallowing Study (VFSS) . Web: American Speech-Language-Hearing Association. Accessed 24 July 2015.
  15. Gramigna, Gary. 2006. How to perform video-fluoroscopic swallowing studies. GI Motility online ed. by Raj Goyal, and Reza Shaker, n.p.. Part 1; (GI Motility online). Web: Nature. Accessed 7 July 2015.
  16. 1 2 Westbury, John. 1991. The significance and measurement of head position during speech production experiments using the x-ray microbeam system. Journal of the Acoustical Society of America 89. 1782 1793. Accessed 24 July 2015.
  17. Westbury, John. June 1994. XRMB History. X-ray Microbeam Speech Production Database User's Handbook, 47. University of Wisconsin.