Electron magnetic circular dichroism

Last updated

Electron magnetic circular dichroism (EMCD) (also known as electron energy-loss magnetic chiral dichroism) is the EELS [1] equivalent of XMCD.

The effect was first proposed in 2003 [2] and experimentally confirmed in 2006 [3] by the group of Prof. Peter Schattschneider at the Vienna University of Technology.

Similarly to XMCD, EMCD is a difference spectrum of two EELS spectra taken in a magnetic field with opposite helicities. Under appropriate scattering conditions [4] virtual photons with specific circular polarizations can be absorbed, giving rise to spectral differences. The largest difference is expected between the case where one virtual photon with left circular polarization and one with right circular polarization are absorbed. By closely analyzing the difference in the EMCD spectrum, information can be obtained on the magnetic properties of the atom, such as its spin and orbital magnetic moment. [5]

In the case of transition metals such as iron, cobalt, and nickel, the absorption spectra for EMCD are usually measured at the L-edge. This corresponds to the excitation of a 2p electron to a 3d state by the absorption of a virtual photon providing the ionisation energy. The absorption is visible as a spectral feature in the electron energy loss spectrum (EELS). Because the 3d electron states are the origin of the magnetic properties of the elements, the spectra contain information on the magnetic properties. Moreover, since the energy of each transition depends on the atomic number, the information obtained is element specific, that is, it is possible to distinguish the magnetic properties of a given element by examining the EMCD spectrum at its characteristic energy (708 eV for iron).

Since in both EMCD and XMCD the same electronic transitions are probed, the information obtained is the same. However EMCD has a higher spatial resolution [6] [7] and depth sensitivity than its X-ray counterpart. Moreover, EMCD can be measured on any TEM equipped with an EELS detector, whereas XMCD is normally measured only on dedicated synchrotron beamlines.

A disadvantage of EMCD in its original incarnation is its requirement of crystalline materials with a thickness and orientation that just precisely gives the correct 90 degree phase shift needed for EMCD. [3] However, a new method has recently demonstrated that electron vortex beams can also be used to measure EMCD without the geometrical constraints of the original procedure. [8]

See also

Related Research Articles

Circular dichroism (CD) is dichroism involving circularly polarized light, i.e., the differential absorption of left- and right-handed light. Left-hand circular (LHC) and right-hand circular (RHC) polarized light represent two possible spin angular momentum states for a photon, and so circular dichroism is also referred to as dichroism for spin angular momentum. This phenomenon was discovered by Jean-Baptiste Biot, Augustin Fresnel, and Aimé Cotton in the first half of the 19th century. Circular dichroism and circular birefringence are manifestations of optical activity. It is exhibited in the absorption bands of optically active chiral molecules. CD spectroscopy has a wide range of applications in many different fields. Most notably, UV CD is used to investigate the secondary structure of proteins. UV/Vis CD is used to investigate charge-transfer transitions. Near-infrared CD is used to investigate geometric and electronic structure by probing metal d→d transitions. Vibrational circular dichroism, which uses light from the infrared energy region, is used for structural studies of small organic molecules, and most recently proteins and DNA.

<span class="mw-page-title-main">Magnetic circular dichroism</span>

Magnetic circular dichroism (MCD) is the differential absorption of left and right circularly polarized (LCP and RCP) light, induced in a sample by a strong magnetic field oriented parallel to the direction of light propagation. MCD measurements can detect transitions which are too weak to be seen in conventional optical absorption spectra, and it can be used to distinguish between overlapping transitions. Paramagnetic systems are common analytes, as their near-degenerate magnetic sublevels provide strong MCD intensity that varies with both field strength and sample temperature. The MCD signal also provides insight into the symmetry of the electronic levels of the studied systems, such as metal ion sites.

Photoemission electron microscopy is a type of electron microscopy that utilizes local variations in electron emission to generate image contrast. The excitation is usually produced by ultraviolet light, synchrotron radiation or X-ray sources. PEEM measures the coefficient indirectly by collecting the emitted secondary electrons generated in the electron cascade that follows the creation of the primary core hole in the absorption process. PEEM is a surface sensitive technique because the emitted electrons originate from a shallow layer. In physics, this technique is referred to as PEEM, which goes together naturally with low-energy electron diffraction (LEED), and low-energy electron microscopy (LEEM). In biology, it is called photoelectron microscopy (PEM), which fits with photoelectron spectroscopy (PES), transmission electron microscopy (TEM), and scanning electron microscopy (SEM).

<span class="mw-page-title-main">Scanning transmission electron microscopy</span> Instrument that produces images by scanning electrons across a sample

A scanning transmission electron microscope (STEM) is a type of transmission electron microscope (TEM). Pronunciation is [stɛm] or [ɛsti:i:ɛm]. As with a conventional transmission electron microscope (CTEM), images are formed by electrons passing through a sufficiently thin specimen. However, unlike CTEM, in STEM the electron beam is focused to a fine spot which is then scanned over the sample in a raster illumination system constructed so that the sample is illuminated at each point with the beam parallel to the optical axis. The rastering of the beam across the sample makes STEM suitable for analytical techniques such as Z-contrast annular dark-field imaging, and spectroscopic mapping by energy dispersive X-ray (EDX) spectroscopy, or electron energy loss spectroscopy (EELS). These signals can be obtained simultaneously, allowing direct correlation of images and spectroscopic data.

<span class="mw-page-title-main">X-ray magnetic circular dichroism</span> Spectroscopic technique

X-ray magnetic circular dichroism (XMCD) is a difference spectrum of two X-ray absorption spectra (XAS) taken in a magnetic field, one taken with left circularly polarized light, and one with right circularly polarized light. By closely analyzing the difference in the XMCD spectrum, information can be obtained on the magnetic properties of the atom, such as its spin and orbital magnetic moment. Using XMCD magnetic moments below 10−5µB can be observed.

Vibrational circular dichroism (VCD) is a spectroscopic technique which detects differences in attenuation of left and right circularly polarized light passing through a sample. It is the extension of circular dichroism spectroscopy into the infrared and near infrared ranges.

The magic angle is a particular value of the collection angle of an electron microscope at which the measured energy-loss spectrum "magically" becomes independent of the tilt angle of the sample with respect to the beam direction. The magic angle is not uniquely defined for isotropic samples, but the definition is unique in the (typical) case of small angle scattering on materials with a "c-axis", such as graphite.

<span class="mw-page-title-main">Rafal E. Dunin-Borkowski</span> British experimental physicist

Rafal Edward Dunin-Borkowski is a British experimental physicist. He is currently Director of the Institute for Microstructure Research (PGI-5) and the Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C) in Forschungszentrum Jülich and Professor of Experimental Physics in RWTH Aachen University.

<span class="mw-page-title-main">Ptychography</span>

Ptychography is a computational method of microscopic imaging. It generates images by processing many coherent interference patterns that have been scattered from an object of interest. Its defining characteristic is translational invariance, which means that the interference patterns are generated by one constant function moving laterally by a known amount with respect to another constant function. The interference patterns occur some distance away from these two components, so that the scattered waves spread out and "fold" into one another as shown in the figure.

Electron nuclear double resonance (ENDOR) is a magnetic resonance technique for elucidating the molecular and electronic structure of paramagnetic species. The technique was first introduced to resolve interactions in electron paramagnetic resonance (EPR) spectra. It is currently practiced in a variety of modalities, mainly in the areas of biophysics and heterogeneous catalysis.

In physics, the Euler–Heisenberg Lagrangian describes the non-linear dynamics of electromagnetic fields in vacuum. It was first obtained by Werner Heisenberg and Hans Heinrich Euler in 1936. By treating the vacuum as a medium, it predicts rates of quantum electrodynamics (QED) light interaction processes.

Peter Schattschneider is an Austrian physicist and science-fiction writer, a retired professor at the Institute of Solid State Physics and a staff member of the USTEM special unit of the Vienna University of Technology. His research focuses on electron microscopy, specifically on electron energy loss spectroscopy and the inelastic interactions between electrons and matter. He is also interested in the history of physics, the science in science fiction, and the role of science in society. His group was responsible for the discovery of electron magnetic circular dichroism in 2006.

<span class="mw-page-title-main">Two-photon circular dichroism</span>

Two-photon circular dichroism (TPCD), the nonlinear counterpart of electronic circular dichroism (ECD), is defined as the differences between the two-photon absorption (TPA) cross-sections obtained using left circular polarized light and right circular polarized light.

<span class="mw-page-title-main">Precession electron diffraction</span>

Precession electron diffraction (PED) is a specialized method to collect electron diffraction patterns in a transmission electron microscope (TEM). By rotating (precessing) a tilted incident electron beam around the central axis of the microscope, a PED pattern is formed by integration over a collection of diffraction conditions. This produces a quasi-kinematical diffraction pattern that is more suitable as input into direct methods algorithms to determine the crystal structure of the sample.

<span class="mw-page-title-main">Orbital angular momentum of free electrons</span>

Electrons in free space can carry quantized orbital angular momentum (OAM) projected along the direction of propagation. This orbital angular momentum corresponds to helical wavefronts, or, equivalently, a phase proportional to the azimuthal angle. Electron beams with quantized orbital angular momentum are also called electron vortex beams.

John Marius Rodenburg is Professor in the Department of Electronic and Electrical Engineering at the University of Sheffield.

<span class="mw-page-title-main">Hyper–Rayleigh scattering</span> Optical phenomenon

Hyper–Rayleigh scattering Optical Activity, is a nonlinear optical physical effect whereby chiral scatterers convert light to higher frequencies via harmonic generation processes, in a way that the intensity of generated light depends on the chirality of the scatterers. "Hyper–Rayleigh scattering" is a nonlinear optical counterpart to Rayleigh scattering. "Optical activity" refers to any changes in light properties that are due to chirality.

<span class="mw-page-title-main">Detectors for transmission electron microscopy</span>

There are a variety of technologies available for detecting and recording the images, diffraction patterns, and electron energy loss spectra produced using transmission electron microscopy (TEM).

The FLEUR code is an open-source scientific software package for the simulation of material properties of crystalline solids, thin films, and surfaces. It implements Kohn-Sham density functional theory (DFT) in terms of the all-electron full-potential linearized augmented-plane-wave method. With this, it is a realization of one of the most precise DFT methodologies. The code has the common features of a modern DFT simulation package. In the past, major applications have been in the field of magnetism, spintronics, quantum materials, e.g. in ultrathin films, complex magnetism like in spin spirals or magnetic Skyrmion lattices, and in spin-orbit related physics, e.g. in graphene and topological insulators.

4D scanning transmission electron microscopy is a subset of scanning transmission electron microscopy (STEM) which utilizes a pixelated electron detector to capture a convergent beam electron diffraction (CBED) pattern at each scan location. This technique captures a 2 dimensional reciprocal space image associated with each scan point as the beam rasters across a 2 dimensional region in real space, hence the name 4D STEM. Its development was enabled by evolution in STEM detectors and improvements computational power. The technique has applications in visual diffraction imaging, phase orientation and strain mapping, phase contrast analysis, among others.

References

  1. Egerton, R F (2009). "Electron energy-loss spectroscopy in the TEM". Reports on Progress in Physics. 72 (1): 016502. Bibcode:2009RPPh...72a6502E. doi:10.1088/0034-4885/72/1/016502. ISSN   0034-4885. S2CID   120421818.
  2. Hébert, C.; Schattschneider, P. (2003). "A proposal for dichroic experiments in the electron microscope". Ultramicroscopy. 96 (3–4): 463–468. doi:10.1016/S0304-3991(03)00108-6. ISSN   0304-3991. PMID   12871808.
  3. 1 2 Schattschneider, P.; Rubino, S.; Hébert, C.; Rusz, J.; Kuneš, J.; Novák, P.; Carlino, E.; Fabrizioli, M.; Panaccione, G.; Rossi, G. (2006). "Detection of magnetic circular dichroism using a transmission electron microscope". Nature. 441 (7092): 486–488. Bibcode:2006Natur.441..486S. doi:10.1038/nature04778. ISSN   0028-0836. PMID   16724061. S2CID   4411302.
  4. Hébert, C.; Schattschneider, P.; Rubino, S.; Novak, P.; Rusz, J.; Stöger-Pollach, M. (2008). "Magnetic circular dichroism in electron energy loss spectrometry". Ultramicroscopy. 108 (3): 277–284. doi:10.1016/j.ultramic.2007.07.011. ISSN   0304-3991. PMID   18060698.
  5. Rusz, J and Eriksson, O and Novak, P and Oppeneer, P M (2007). "Sum-rules for electron energy-loss near-edge spectra". Phys. Rev. B. 76 (6): 060408. arXiv: 0706.0402 . Bibcode:2007PhRvB..76f0408R. doi:10.1103/PhysRevB.76.060408. S2CID   119144850.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  6. Schattschneider, P; Stöger-Pollach, M; Rubino, S; Sperl, M; Hurm, C; Zweck, J; Rusz, J (2008). "Detection of Magnetic Circular Dichroism on the 2 nm scale" (PDF). Phys. Rev. B. 78 (10): 104413. Bibcode:2008PhRvB..78j4413S. doi:10.1103/PhysRevB.78.104413.
  7. Schattschneider, P and Hèbert, C and Rubino, S and Stöger-Pollach, M and Rusz, J and Novak, P (2008). "Magnetic circular dichroism in EELS: towards 10 nm resolution". Ultramicroscopy. 108 (5): 433–438. arXiv: cond-mat/0703021 . doi:10.1016/j.ultramic.2007.07.002. PMID   17698291. S2CID   14377662.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  8. Verbeeck, J; Tian, H; Schattschneider, P (2010). "Production and application of electron vortex beams". Nature. 467 (7313): 301–304. Bibcode:2010Natur.467..301V. doi:10.1038/nature09366. PMID   20844532. S2CID   2970408.