IDA Indoor Climate and Energy

Last updated

IDA IndoorClimate andEnergy (IDA ICE) is a Building performance simulation (BPS) software. IDA ICE is a simulation application for the multi-zonal and dynamic study of indoor climate phenomena as well as energy use. The implemented models are state of the art, many studies show that simulation results and measured data compare well. [1] [2] [3]

Contents

IDA Indoor Climate and Energy
Developer(s) EQUA Simulation AB
Initial release1998
Stable release
4.8 (SP2)
Written inNMF, Modelica
Operating system Windows
Available inEnglish, German, French, Swedish, Finnish
License Trialware
Website www.equa.se/en/ida-ice

User interface

The user interface of IDA ICE makes it easy to create simple cases but also offers the flexibility to go into detail of advanced studies. Many inputs are adaptable to local requirements such as climate data, material data, system components or result reports. IDA ICE provides a 3D environment for geometry modeling, the table-based input of boundary conditions provide good visual feedback and enables efficient quality check. A simple procedure for calculating and reporting cooling, heating, air demand, and energy, together with a built-in version handling system, makes it efficient to compare different systems and results.

Advanced daylight calculation are achieved by interfacing the Radiance lighting simulation tool with result visualization in the 3D environment. A module for Appendix G of ASHRAE 90.1-2010 is available, this is used for example in LEED and BREEAM. The integrated radiosity method with single reflection and one measuring point can be used for whole-year daylight analysis and allows modeling daylight-based control strategies (e.g. shading devices, artificial lightening).

There is also the "Early Stage Building Optimization" (ESBO) [4] user interface which makes it possible for users to experiment with variations in both buildings and systems at an early stage with a minimum of user input. A full range of component models for renewable energy studies is available, with boreholes, stratified tanks, heat pumps, solar collectors, CHP, PV, wind turbines, etc.

An interface with OpenFOAM for detailed CFD studies is in development.

Input

IDA ICE supports IFC BIM models generated by tools such as ArchiCAD, Revit, MagiCAD, and others. Geometry an shading on site can also be imported from SketchUp, Rhino or other geometry tools. Solar influx is evaluated through windows (also internal) with full 3D accounting for the local shading situation. Additionally it has an integrated geometry editor where building and zone geometry can be modeled with 2D architectural drawings or pictures serving as template.

Climate files like EnergyPlus weather files (EPW) or ASHRAE climate files, can be downloaded and installed. The table-based input structure allows full interoperability with MS Excel and comparable software. Modern features like copy and paste and Drag&drop combined with visual input data check make input data management easier.

Output

IDA ICE output include tables, charts, reports and plots. 3D visualizations (both stills and animations) show geometry, solar shadings, color coded input data as well as results. Arrow animations in 3D visualize ventilation air flows, window energy balance, and wind driven flows. There are special reports for LEED submittal forms included. The diagram plots deliver vector graphics which allows detailed result analysis in custom reports. Results can be exported to Microsoft Word or Excel. A single zone IDA ICE model with default systems comprises a total of approximately 2 000 time dependent variables, any of which may be plotted.

Predefined output files and reports cover

Related Research Articles

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Passive solar building design</span> Architectural engineering that uses the Suns heat without electric or mechanical systems

In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.

<span class="mw-page-title-main">Scientific visualization</span> Interdisciplinary branch of science concerned with presenting scientific data visually

Scientific visualization is an interdisciplinary branch of science concerned with the visualization of scientific phenomena. It is also considered a subset of computer graphics, a branch of computer science. The purpose of scientific visualization is to graphically illustrate scientific data to enable scientists to understand, illustrate, and glean insight from their data. Research into how people read and misread various types of visualizations is helping to determine what types and features of visualizations are most understandable and effective in conveying information.

<span class="mw-page-title-main">Heat recovery ventilation</span> Method of reusing thermal energy in a building

Heat recovery ventilation (HRV), also known as mechanical ventilation heat recovery (MVHR), is an energy recovery ventilation system that operates between two air sources at different temperatures. It's a method that is used to reduce the heating and cooling demands of buildings. By recovering the residual heat in the exhaust gas, the fresh air introduced into the air conditioning system is preheated before it enters the room, or the air cooler of the air conditioning unit performs heat and moisture treatment. A typical heat recovery system in buildings comprises a core unit, channels for fresh and exhaust air, and blower fans. Building exhaust air is used as either a heat source or heat sink, depending on the climate conditions, time of year, and requirements of the building. Heat recovery systems typically recover about 60–95% of the heat in the exhaust air and have significantly improved the energy efficiency of buildings.

<span class="mw-page-title-main">Heliodon</span>

A heliodon (HEE-leo-don) is a device for adjusting the angle between a flat surface and a beam of light to match the angle between a horizontal plane at a specific latitude and the solar beam. Heliodons are used primarily by architects and students of architecture. By placing a model building on the heliodon’s flat surface and making adjustments to the light/surface angle, the investigator can see how the building would look in the three-dimensional solar beam at various dates and times of day.

Building automation(BAS), also known as building management system (BMS) or building energy management system (BEMS), is the automatic centralized control of a building's HVAC (heating, ventilation and air conditioning), electrical, lighting, shading, access control, security systems, and other interrelated systems. Some objectives of building automation are improved occupant comfort, efficient operation of building systems, reduction in energy consumption, reduced operating and maintaining costs and increased security.

<span class="mw-page-title-main">Building science</span>

Building science is the science and technology-driven collection of knowledge in order to provide better indoor environmental quality (IEQ), energy-efficient built environments, and occupant comfort and satisfaction. Building physics, architectural science, and applied physics are terms used for the knowledge domain that overlaps with building science. In building science, the methods used in natural and hard sciences are widely applied, which may include controlled and quasi-experiments, randomized control, physical measurements, remote sensing, and simulations. On the other hand, methods from social and soft sciences, such as case study, interviews & focus group, observational method, surveys, and experience sampling, are also widely used in building science to understand occupant satisfaction, comfort, and experiences by acquiring qualitative data. One of the recent trends in building science is a combination of the two different methods. For instance, it is widely known that occupants’ thermal sensation and comfort may vary depending on their sex, age, emotion, experiences, etc. even in the same indoor environment. Despite the advancement in data extraction and collection technology in building science, objective measurements alone can hardly represent occupants' state of mind such as comfort and preference. Therefore, researchers are trying to measure both physical contexts and understand human responses to figure out complex interrelationships.

<span class="mw-page-title-main">Solar gain</span> Solar energy effect

Solar gain is the increase in thermal energy of a space, object or structure as it absorbs incident solar radiation. The amount of solar gain a space experiences is a function of the total incident solar irradiance and of the ability of any intervening material to transmit or resist the radiation.

Thermal comfort is the condition of mind that expresses satisfaction with the thermal environment and is assessed by subjective evaluation. The human body can be viewed as a heat engine where food is the input energy. The human body will release excess heat into the environment, so the body can continue to operate. The heat transfer is proportional to temperature difference. In cold environments, the body loses more heat to the environment and in hot environments the body does not release enough heat. Both the hot and cold scenarios lead to discomfort. Maintaining this standard of thermal comfort for occupants of buildings or other enclosures is one of the important goals of HVAC design engineers.

<span class="mw-page-title-main">VSim</span>

VSim is a cross-platform computational framework for multiphysics including electrodynamics in the presence of metallic and dielectric shapes as well as with or without self-consistent charged particles and fluids. It is compatible with compatible with Windows, Linux, and macOS.

<span class="mw-page-title-main">Thermal bridge</span>

A thermal bridge, also called a cold bridge, heat bridge, or thermal bypass, is an area or component of an object which has higher thermal conductivity than the surrounding materials, creating a path of least resistance for heat transfer. Thermal bridges result in an overall reduction in thermal resistance of the object. The term is frequently discussed in the context of a building's thermal envelope where thermal bridges result in heat transfer into or out of conditioned space.

Specialized wind energy software applications aid in the development and operation of wind farms.

Fire Dynamics Simulator (FDS) is a computational fluid dynamics (CFD) model of fire-driven fluid flow. The computer program solves numerically a large eddy simulation form of the Navier–Stokes equations appropriate for low-speed, thermally-driven flow, with an emphasis on smoke and heat transport from fires, to describe the evolution of fire.

TracePro is a commercial optical engineering software program for designing and analyzing optical and illumination systems. The program's graphical user interface (GUI) is 3D CAD-based creating a virtual prototyping environment to perform software simulation before manufacture.

<span class="mw-page-title-main">Underfloor air distribution</span>

Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets, located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

<span class="mw-page-title-main">Building performance simulation</span> Replication of aspects of building performance

Building performance simulation (BPS) is the replication of aspects of building performance using a computer-based, mathematical model created on the basis of fundamental physical principles and sound engineering practice. The objective of building performance simulation is the quantification of aspects of building performance which are relevant to the design, construction, operation and control of buildings. Building performance simulation has various sub-domains; most prominent are thermal simulation, lighting simulation, acoustical simulation and air flow simulation. Most building performance simulation is based on the use of bespoke simulation software. Building performance simulation itself is a field within the wider realm of scientific computing.

OpenStudio is a suite of free and open-source software applications for building energy analysis used in building information modeling. OpenStudio applications run on Microsoft Windows, Macintosh, and Linux platforms. Its primary application is a plugin for proprietary SketchUp, that enables engineers to view and edit 3D models for EnergyPlus simulation software.

Sensitivity analysis identifies how uncertainties in input parameters affect important measures of building performance, such as cost, indoor thermal comfort, or CO2 emissions. Input parameters for buildings fall into roughly three categories:

<span class="mw-page-title-main">Ventilative cooling</span>

Ventilative cooling is the use of natural or mechanical ventilation to cool indoor spaces. The use of outside air reduces the cooling load and the energy consumption of these systems, while maintaining high quality indoor conditions; passive ventilative cooling may eliminate energy consumption. Ventilative cooling strategies are applied in a wide range of buildings and may even be critical to realize renovated or new high efficient buildings and zero-energy buildings (ZEBs). Ventilation is present in buildings mainly for air quality reasons. It can be used additionally to remove both excess heat gains, as well as increase the velocity of the air and thereby widen the thermal comfort range. Ventilative cooling is assessed by long-term evaluation indices. Ventilative cooling is dependent on the availability of appropriate external conditions and on the thermal physical characteristics of the building.

References

  1. Cornaro, Cristina; Puggioni, Valerio Adoo; Strollo, Rodolfo Maria (2016). "Dynamic simulation and on-site measurements for energy retrofit of complex historic buildings: Villa Mondragone case study". Journal of Building Engineering. 6: 17–28. doi:10.1016/j.jobe.2016.02.001.
  2. Christensen, Jørgen Erik; Chasapis, Kleanthis; Gazovic, Libor; Kolarik, Jakub (2015). "Indoor Environment and Energy Consumption Optimization Using Field Measurements and Building Energy Simulation". Energy Procedia. 78: 2118–2123. doi: 10.1016/j.egypro.2015.11.281 .
  3. Nageler, P.; Schweiger, G.; Pichler, M.; Brandl, D.; Mach, T.; Heimrath, R.; Schranzhofer, H.; Hochenauer, C. (2018). "Validation of dynamic building energy simulation tools based on a real test-box with thermally activated building systems (TABS)". Energy and Buildings. 168: 42–55. doi:10.1016/j.enbuild.2018.03.025.
  4. "ESBO user interface". EQUA Simulation AB. Retrieved 2018-04-02.