Multispectral optoacoustic tomography

Last updated
Multispectral optoacoustic tomography
Purposeimaging technology that generates high-resolution optical images including biological tissues.

Multi-spectral optoacoustic tomography (MSOT), also known as functional photoacoustic tomography (fPAT), is an imaging technology that generates high-resolution optical images in scattering media, including biological tissues. MSOT illuminates tissue with light of transient energy, typically light pulses lasting 1-100 nanoseconds. The tissue absorbs the light pulses, and as a result undergoes thermo-elastic expansion, a phenomenon known as the optoacoustic or photoacoustic effect. This expansion gives rise to ultrasound waves (photoechoes) that are detected and formed into an image. Image formation can be done by means of hardware (e.g. acoustic focusing or optical focusing) or computed tomography (mathematical image formation). Unlike other types of optoacoustic imaging, MSOT involves illuminating the sample with multiple wavelengths, allowing it to detect ultrasound waves emitted by different photoabsorbing molecules in the tissue, whether endogenous (oxygenated and deoxygenated hemoglobin, melanin) or exogenous (imaging probes, nanoparticles). Computational techniques such as spectral unmixing deconvolute the ultrasound waves emitted by these different absorbers, allowing each emitter to be visualized separately in the target tissue. In this way, MSOT can allow visualization of hemoglobin concentration and tissue oxygenation or hypoxia. Unlike other optical imaging methods, MSOT is unaffected by photon scattering and thus can provide high-resolution optical images deep inside biological tissues. [1]

Contents

Description

MSOT has been described as a 6-dimensional (6-parametric) method, in which the three geometrical dimensions (x, y, z) are complemented by time, illumination wavelengths and band of ultrasound frequencies detected. MSOT can measure over time, allowing longitudinal studies of dynamic processes. [2] Illumination wavelengths in MSOT can cover the entire spectrum from ultraviolet (UV) to infrared (IR). [1] The wavelength defines the photoabsorbers that can be seen and the imaging depth. High-energy ion beams [3] and energy in the radiofrequency range [4] [5] have also been used. The choice of ultrasound frequency band defines resolution and overall size range of the objects that can be resolved. This choice of frequency band dictates whether the imaging will be in the macroscopic regime, involving resolution of 100-500 microns and penetration depth >10 mm, or mesoscopic range, involving resolution of 1-50 microns and penetration depth <10 mm. [1] [6] Microscopic resolution is also possible using multi-spectral optoacoustics. [1] [6] Like optical microscopy, they use focused light to form images and offers fundamentally the same capabilities (submicrometer resolution, <1mm penetration depth).

MSOT has now been used in a broad range of biological applications, including cardiovascular disease research, [7] [8] neuroimaging [9] [10] [11] [12] and cancer research. [13] [14] [15] The development of real-time hand-held imaging systems [2] [16] has enabled clinical use of MSOT for imaging the breast, [17] [18] [19] vasculature, [20] [21] lymph nodes [22] and skin. [23] [24]

Etymology

Multi-spectral. MSOT collects images at multiple wavelengths and resolves the spectral signatures in each voxel imaged, making it a multi-spectral method. Typically, MSOT is used to generate three images: one anatomical image at a single wavelength, one functional image resolving oxy- and deoxy-hemoglobin concentrations, and a third image resolving additional target photoabsorber(s). These additional photoabsorbers include melanin, fat, water and other endogenous or exogenous agents.

Optoacoustic. This term denotes the combination of optical (Greek, oπτικός) and acoustic (Greek, ακουστικός) energy (or components) in a single modality, which distinguishes optoacoustic imaging from optical imaging. Photoecho denotes the combination of light (Greek, Φως <phos>) and sound ( Ήχος <echos>) or reflection of sound Hχώ <echo>). The term photoacoustic is also widely used, and it denotes the generation of acoustic energy by light. Photoecho and photoacoustic are to optoacoustics what photon is to optics: optical methods rely on photons, whereas optoacoustic methods rely on photoechoes or photoacoustic responses.

Tomography. This term denotes images formed by combining raw measurements from multiple points around the specimen in a mathematical inversion scheme. This process is analogous to x-ray computed tomography, except that tomographic mathematical models describe light and sound propagation in tissues.

1m2.jpg

Fig. 1: Operational capabilities of MSOT. Hybrid image showing an optical micrograph of part of a mouse kidney cross-section (gray), overlaid with the distribution of an exogenous fluorescent agent imaged using MSOT (right). Distribution of oxy-hemoglobin (red) and deoxy-hemoglobin (blue) in the tumor, imaged using MSOT (left).

Operating principles

MSOT detects photoechoes, i.e. ultrasound waves generated by thermo-elastic expansion of a sample (e.g. tissue) after absorption of transient electromagnetic energy. Typically, the sample is illuminated with light pulses in the nanosecond range, [25] although intensity-modulated light can also be used. [26] [27] At least some of the electromagnetic energy absorbed by the sample is converted to heat; the resulting temperature rise, on the order of milli-Kelvins, leads to thermo-elastic expansion of the sample. This creates a pressure wave in the form of a broadband ultrasound wave. The ultrasound waves emitted by the sample are detected by transducers positioned near the sample, usually at multiple positions around it. The amplitude of the pressure wave provides information about the local absorption and propagation of energy in the sample, while the time interval between the illumination pulse and arrival of the ultrasound wave at the detector provides information about the distance between the detector and photoecho source. Optoacoustic data collected over time and at multiple positions around the sample are processed using tomographic reconstruction to produce images of the distribution of photoabsorbers in the sample. Data collected after illumination at single wavelengths allow imaging of the distribution of photoabsorbers that share similar absorption characteristics at the given wavelength. Data collected after illumination with multiple wavelengths allow specific distinction of photoabsorbers with different optical absorption spectra, such as oxy- and deoxy-hemoglobin, myoglobin, melanin or exogenous photoabsorbers. [1] The wavelengths of light used to illuminate samples in MSOT are selected based on the absorption characteristics of the target photoabsorbers. To resolve the individual photoabsorbers, images obtained at multiple wavelengths must be further processed using subtraction or spectral unmixing techniques. Background in images can be reduced by exploiting differences in time (baseline subtraction) and in absorption spectra of the various photoabsorbers (spectral unmixing).

Operational dimensions

MSOT has the potential to provide multi-parametric information involving the three spatial dimensions (x, y, z), time, optical wavelength spectrum and ultrasound frequency range. It has therefore been described as a six-dimensional modality. [2] This dimensionality has been made possible by key advances in laser source and detector technology, computed tomography and unmixing techniques. [2] The capabilities and challenges of each MSOT dimension are described below.

Volumetric imaging

Optoacoustic (photoacoustic) imaging is intrinsically a three-dimensional imaging method, since photoechoes (optoacoustic waves) propagate in all three spatial dimensions. Optimal tomographic imaging is therefore achieved by recording time-resolved pressure waves along a closed surface volumetrically surrounding the target tissue. Typically, three-dimensional imaging systems achieve this by scanning a single ultrasound sensor around the sample, or by using one-dimensional [28] or two-dimensional [29] [30] ultrasound sensor arrays to parallelize detection.

A large amount of data must be collected and processed for truly three-dimensional imaging, necessitating a large detector array, long scanning times, and heavy computational burden. To reduce these requirements, the three-dimensional problem is often simplified to a quasi-two-dimensional problem by using focused ultrasound detectors to limit ultrasound detection to a two-dimensional plane in the illuminated volume. The result is a series of two-dimensional, cross-sectional images, which can be collected in real time and can show quite high in-plane resolution if detector elements are packed at high density around the image plane. [16] [31] Translating the detector along the third dimension then allows volumetric scanning. [32]

3m2 msot.jpg

Fig. 2: Volumetric optoacoustic imaging and comparison with reflection-mode ultrasound computed tomography. Cross-sectional tomographic ultrasound (right) and optoacoustic (middle) whole-body image stacks of a living mouse. Histology cross-sections of the tissue shown on the left. [33]

Video-rate (real-time) imaging

Early optoacoustic imaging involved scanning a single ultrasound detector along one or two dimensions, resulting in acquisition times of several seconds, minutes or longer. This made the technique impractical for in vivo animal imaging or clinical use. Technological advances in detector arrays and analog-to-digital converters allow simultaneous data collection over 512 parallel elements, substantially shortening the amount of time needed to acquire a tomographic dataset, even to the point of allowing video-rate imaging. In addition, lasers have been developed that allow switching between wavelengths within 20 ms, enabling video-rate MSOT. [16] [30] Video-rate imaging not only reduces motion artifacts, but also allows in vivo study of biological processes, even in hand-held mode. It also gives the operator real-time feedback essential for orientation and fast localization of areas of interest. [2]

4m msot.jpg

Fig. 3: Five-dimensional imaging of mouse brain perfusion in vivo. (a) Layout of the experimental set-up. (b) Maximal-intensity projections along the axial direction following single-wavelength illumination before (upper) and after injection of two concentrations of contrast agent (10nmol in the middle and 50 nmol lower), indocyanine green. The lower concentration does not provide strong signal over the background signal from blood. Different structures in the mouse brain are indicated: sv, supraorbital veins; icv, inferior cerebral vein; sss, superior sagittal sinus; cs, confluence of sinuses; ts, transverse sinus. (c) Time series of maximal-intensity projections following multi-wavelength illumination after injection of 10 nmol indocyanine green. Inflow of the contrast agent can be followed in real time.

Multi-spectral imaging

A key strength of MSOT is its ability to resolve the photoechoes obtained in response to excitation with different wavelengths of illuminating light. Since the photoechoes depend on the optical absorption characteristics of molecules within the target tissue (or added to the tissue), MSOT can image the distributions of specific photoabsorbing molecules. The endogenous photoabsorbers most often imaged are oxy- and deoxy-hemoglobin, key players in oxygen metabolism, myoglobin, lipids, melanin and water. Several exogenous contrast agents have also been used in MSOT, including some common histology dyes, fluorescent dyes, novel metal-based agents and non-metallic nanoparticles. [2] Transfecting target tissue with reporter genes to express contrast agents in situ has also been reported, such as transfection with the tyrosinase gene to produce melanin. [34] [35]

Through spectral unmixing and other techniques, MSOT data can be used to generate separate images based on the contrast provided by different photoabsorbers. In other words, a single MSOT data collection run provides separate images showing the distribution of oxy- or deoxy-hemoglobin. These images can be merged to provide a complete picture of tissue oxygenation/hypoxia. By using hemoglobin as an intrinsic oxygen sensor, MSOT is the only method available that can provide high-resolution images of tissue oxygenation without the need for exogenous labels. [36] At the same time, MSOT can image additional endogenous photoabsorbers such as lipids and water, as well as exogenous contrast agents.

Imaging with different ultrasound frequency bands (macro-, meso- and microscopy)

Photoechoes show an ultra-wide frequency profile, which is determined by the pulse width of the illuminating pulse and the size of the object. Ultimately, though, the frequencies that can be collected and processed for image reconstruction are determined by the ultrasound detector. Macroscopic MSOT typically uses detectors operating in the frequency range from 0.1 to 10 MHz, allowing imaging depths of approximately 1–5 cm and resolution of 0.1–1 mm. Illumination light wavelengths are typically chosen from the near-IR region of the spectrum and spread over the sample to allow deep penetration. Images are then generated using computed tomography. Such macroscopy is useful for animal and human imaging to analyze tissue anatomy, physiology and response to drugs. Regions of interest are approximately 30–50 cm3, and resolution of 200-300 microns is typical.

Ultrasound detectors have been developed that collect bandwidths of 10-200 MHz or wider, which allows unprecedented mesoscopy at tissue depths of 0.1–1 cm with resolution that can exceed 10 microns even at depths of several millimeters. Illumination light is typically unfocused and selected from the visible and near-IR regions of the spectrum. Images are generated using computed tomography. Such mesoscopy can analyze morphology and biological processes such as inflammation in greater detail than macroscopy, revealing, for example, microvasculature networks in skin and epithelial tissues or the microenvironment within a tumor. [37] Regions of interest are approximately 50 mm3, and resolution of 5-30 microns is typical.

The possibility of applying optoacoustics to the microscopic regime has been suggested. [37] This involves scanning focused light on the tissue surface. The imaging depth (typically <1 mm) and quality of the resulting image are limited by optical diffraction and scattering, not by ultrasound diffraction. In other words, optoacoustic microscopy has the same limitations as conventional optical microscopy. Together, however, the two microscopies can provide more information than either on its own. [38]

Operational characteristics

Modes of operation

MSOT can operate in three imaging modes: [2]

  1. anatomical imaging, which can be performed using a single wavelength of illuminating light and at multiple scales. This mode has been used to visualize various tissue structures and organs in laboratory animals and humans, including vasculature, kidney, heart, liver, brain and muscle.
  2. functional/dynamic imaging, which can be performed at video rates to reveal changes in tissue contrast caused by hemodynamics, motion such as vessel pulsation, and uptake of drugs (pharmacodynamics).
  3. biological / molecular imaging, which exploits the multi-spectral capability of MSOT. This mode has been used to visualize tissue oxygenation, reporter genes, fluorescent proteins and various exogenous agents (e.g. fluorescent dyes, nanoparticles, target-specific agents) in laboratory animals and humans.

Challenges to MSOT-based quantification

MSOT provides anatomical, dynamic and molecular information, but quantifying the features of MSOT images is not straightforward because constituents of the target tissue absorb and scatter the illuminating light. As a result, the illuminating light is attenuated as one moves deeper into the tissue, and the extent of attenuation depends on wavelength. The measured spectral signature of photoabsorbers inside tissue may therefore differ from the absorption spectrum of the same molecule measured inside the cuvette of a spectrophotometer. This discrepancy, termed "spectral coloring", depends on the number and types of photoabsorbers in the propagation path. Spectral coloring poses a challenge to spectral unmixing, which requires accurate knowledge of the absorption spectrum. Moreover, optoacoustic imaging, with a resolution in the range of 1-100 μm, cannot resolve individual photoabsorbing molecules. As a result, the spectral response of the photoabsorber of interest is a linear combination of the spectral responses of background tissue constituents, such as oxy- and deoxy-hemoglobin, melanin, water, lipids and unknown metabolites, [39] which further complicates unmixing. Recently, eigenspectra MSOT has been developed to model more accurately the spectral responses of different photoabsorbers in three-dimensional tissue. [36] This may help improve spectral unmixing and therefore image quality.

Sensitivity

MSOT can resolve various optoacoustic moieties based on their absorption spectrum, including nanoparticles, dyes and fluorochromes. Most fluorochromes are optimized for fluorescence emission and are sub-optimal for optoacoustic detection, because after absorbing the illuminating energy, they tend to emit fluorescence rather than convert it to heat and generate a photoecho. Dyes with higher absorption cross-sections generate stronger optoacoustic signals. [40]

Therefore, the sensitivity of MSOT depends on the contrast agent used, its distribution and accumulation in the target tissue, and its resistance to photobleaching by the illuminating light. Sensitivity also depends on the ultrasound detector employed, the amount of light energy applied, the voxel size and spectral unmixing method. As imaging depth increases, light and ultrasound attenuation together reduce the optoacoustic signal and therefore the overall detection sensitivity. Ultrasound attenuation is frequency-dependent: higher frequencies are attenuated faster with increasing depth. Selecting ultrasound detectors that are most sensitive at the appropriate frequency can improve sensitivity at the target imaging depth, but at the cost of spatial resolution. [2]

Earlier calculations predicted that MSOT should be able to detect concentrations of organic fluorochromes as low as 5 nM. [41] These calculations did not properly account for frequency-dependent attenuation of ultrasound in tissue or for the requirements of spectral unmixing. [42] Experimental results suggest an in vivo detection sensitivity of 0.1-1 μM for organic dyes with a minimum detectable optical absorption coefficient of 0.1–1 cm−1, such as indocyanine green and Alexa fluochromes. [43] Advanced spectral unmixing methods based on statistical detection schemes can improve MSOT sensitivity. [43] [44]

Contrast and applications

Optoacoustic imaging in general, and MSOT in particular, have been applied to various analyses of animal models, including imaging of organs, pathology, functional processes and bio-distribution. This range of applications demonstrates the flexibility of MSOT, which reflects the range of contrast agents available. Practically every molecule that absorbs light and converts it to a pressure wave has the potential to be detected with optoacoustics. Contrast agents absorbing light in the near-IR are particularly attractive, because they enable imaging at greater depth. [45]

Endogenous contrast agents

Hemoglobin is the dominant absorber of light in the visible and near-IR part of the optical spectrum and is commonly used for optoacoustic imaging. Endogenous contrast provided by hemoglobin allows sensitive imaging of vascular anatomy at various scales. [37] Using MSOT further allows the distinction between oxygenation states of hemoglobin, enabling label-free assessment of tissue oxygenation and hypoxia, [36] both of which are useful parameters in many pathologies and functional studies. Hemoglobin-based imaging to resolve vascular abnormalities and oxygenation status may be useful for various applications, including perfusion imaging, inflammation imaging, and tumor detection and characterization. [2]

Melanin is another important endogenous absorber; it absorbs over a broad range of wavelengths in the visible and near-IR range, with absorption decreasing at longer wavelengths. Optoacoustic imaging of melanin has been used to assess the depth of melanoma ingrowth inside epithelial tissue [46] and to assess the metastatic status of sentinel lymph nodes in melanoma patients. It can also detect circulating melanoma cells. [47]

MSOT can detect several other endogenous tissue absorbers, as long as the correct wavelength range is used to illuminate the sample. Lipids can be imaged at near-IR wavelengths, with the absorption peak occurring at 930 nm. Water absorbs strongly at near-IR wavelengths longer than 900 nm, with a strong peak at 980 nm. Bilirubin and cytochromes can be imaged at blue wavelengths. UV absorption by DNA has also been exploited to image cell nuclei. [48] [49]

Exogenous contrast agents

A multitude of exogenous contrast agents have been developed, or are under development, for optoacoustics. These contrast agents should have an absorption spectrum different from that of endogenous tissue absorbers, so that they can be separated from other background absorbers using spectral unmixing. Different classes of exogenous contrast agents exist. [2] [48] Organic dyes, such as the fluorochromes indocyanine green and methylene blue, are non-specific, approved for clinical use, and suitable for perfusion imaging. They typically have low quantum yield, so they convert a large portion of absorbed energy into heat and thus photoechoes. Since these dyes can be imaged based on optoacoustics and fluorescence, the two types of microscopies can be used to complement and verify each other. [50] In fact, organic dyes are generally well characterized because of their widespread use in fluorescence imaging. [48] Photosensitizers, already in clinical use for photodynamic therapy, can be detected using MSOT, allowing analysis of their pharmacokinetics and bio-distribution in vivo. [51] Light-absorbing nanoparticles offer potential advantages over organic dyes because of their ability to produce stronger photoechoes and their lower photosensitivity. One disadvantage is that they must be approved individually for human use because their safety has not been well established. Gold nanoparticles, [52] silver nanoparticles, [53] carbon nanotubes, [54] and iron-oxide particles have been used for optoacoustic imaging in animals. Gold nanoparticles generate strong optoacoustic signals due to plasmon resonance, and their absorption spectrum can be tuned by modifying their shape. Some iron oxide nanoparticles, such as SPIO, have already been approved for the clinic as MRI contrast agents. [48]

Targeted contrast agents [55] combine a dye or nanoparticle with a targeting ligand to provide MSOT contrast at specific tissues or in the presence of specific cellular or molecular processes. Such agents have been used in MSOT imaging of integrins within tumors in animals. [56] Targeted agents can also be activatable, such that their absorption spectrum changes as the result of a change in the microenvironment. For example, a contrast agent activatable by matrix metalloproteinase (MMP) cleavage has been used to image MMP activity within thyroid tumors in mice. [48] [57]

Fluorescent proteins that are already widespread, powerful tools for biomedical research, such as green fluorescent protein, can also be visualized using MSOT. Newly developed fluorescent proteins that absorb in the near-IR range (e.g. red fluorescent protein) allow imaging deep inside tissues. [9] [58] [59] MSOT based on in situ expression of fluorescent proteins can take advantage of tissue- and development-specific promoters, allowing imaging of specific parts of an organism at specific stages of development. For example, eGFP and mCherry fluorescent proteins have been imaged in model organisms such as Drosophila melanogaster pupae and adult zebrafish, [58] and mCherry has been imaged in tumor cells in the mouse brain. [9] This transgenic approach is not limited to fluorescent proteins: infecting tissue with a vaccinia virus carrying the tyrosinase gene allows in situ production of melanin, which generates strong optoacoustic signal for MSOT. [48] [60]

Emerging applications

Because of its ability to provide spatial and spectral resolution in real time on multiple scales, optoacoustic imaging in general and MSOT in particular are likely to play an important role in clinical imaging and management of cancer, cardiovascular disease and inflammation. MSOT presents numerous advantages over other radiology modalities because of its ability to resolve oxygenated and deoxygenated hemoglobin, its compatibility with a broad array of exogenous contrast agents, its scalability and its ability to image rapidly even below the tissue surface. [2]

Imaging of pharmacokinetics

MSOT can track the fate of administered agents in blood circulation, allowing real-time, in vivo analysis of pharmacokinetics. This may reduce the numbers of animals needed in biomedical research. [61]

Breast cancer imaging

Several optoacoustic studies [19] [62] [63] have aimed to improve on the poor sensitivity of X-ray mammography in dense breast tissue and the low specificity of ultrasound imaging. MSOT may miss fewer malignancies in dense breast tissue than these conventional modalities because optoacoustic contrast is unaffected by breast density. MSOT studies of breast cancer typically focus on detecting the increased vascular density and correspondingly high hemoglobin concentration thought to occur in and around tumors. The flexibility of MSOT may also allow imaging of other tissue and cancer biomarkers not detectable with current methods. [48]

Vascular disease imaging

The hemoglobin distribution in carotid arteries of healthy humans has recently been imaged in real time using a hand-held device similar to diagnostic ultrasound systems currently in the clinic. [16] [20] [64] The ability to image blood vessels in hands and feet may be useful for assessing peripheral vascular disease. [2] [20]

Fig. 4: MSOT of human vasculature. The handheld MSOT probe shown here to measure photoechoes from hemoglobin, allows more sensitive detection of small blood vessels than Doppler ultrasound already in the clinic. Different structures are indicated: ADP, dorsalis pedis artery; ATP, tibialis posterior artery; MH, medial hallux; DH, distal hallux.

Skin imaging

Optoacoustic mesoscopy is suitable for imaging skin lesions. Studies in preclinical models have imaged subcutaneous lesions and their vascular networks and demonstrated the potential to reveal lesion details such as depth, vascular morphology, oxygenation and melanin content. [23] [65] Combining optoacoustic mesoscopy with exogenous agents may provide further useful information. [48]

Endoscopy

Light delivery and ultrasound detection can be miniaturized to create optoacoustic endoscopy systems for gastrointestinal applications. A system combining MSOT and ultrasound endoscopy has been used to image the esophagus and colon in rats and rabbits. [66] [67] [68] [69] [70] [71] The MSOT images revealed vascular features and hemoglobin oxygenation that was not detectable by ultrasound. Moreover, optoacoustic endoscopy can detect the exogenous dye Evans blue after injection into the lymphatic system. Ongoing technological progress is expected to allow optoacoustic imaging of the gastrointestinal tract in humans in the near future, which may allow three-dimensional analysis of suspicious lesions, providing more complete information than white light endoscopy. [2] [48]

Intravascular imaging

Miniaturized optoacoustic devices are also expected to offer interesting possibilities for intravascular imaging [72-74], improving our ability to detect atherosclerosis and stent-related biomarkers. Optoacoustic imaging is likely to be well suited to this application, since it can detect lipids, neovasculature, hemoglobin oxygenation and contrast agents that mark inflammation. [48]

Examination of metastatic status of sentinel lymph nodes

Melanoma metastasizes early into regional lymph nodes, so excision and analysis of so-called sentinel lymph nodes is important for treatment planning and prognosis assessment. To identify the sentinel lymph node for excision, a gamma-emitting radiotracer is injected inside the primary tumor and allowed to accumulate inside the sentinel lymph node. MSOT may provide a non-radioactive, non-invasive alternative for examination of the metastatic status of the sentinel lymph node. Initial studies have shown that MSOT can detect sentinel lymph nodes based on indocyanine green (ICG) accumulation after injection in the tumor, as well as melanoma metastasis inside the lymph nodes. [22]

14m msot.jpg

Fig. 5: MSOT for determination of the metastatic status of sentinel lymph nodes in melanoma patients. (A) Indocyanine green (ICG) is injected and accumulates inside the sentinel lymph node, which is detected using a hand-held two-dimensional MSOT device. (b) MSOT images of the ICG accumulating in the sentinel lymph node (in color), overlaid on a background image of tissue illuminated at a single wavelength. Each image came from a different patient. (c) MSOT imaging of melanin (in color) overlaid on a background image of tissue. The first image shows a patient without melanoma metastasis. The second image shows a patient with melanoma metastasis inside the sentinel lymph node. In both cases, strong melanin signal from the skin can be seen

Intraoperative imaging

Optoacoustic imaging in general and MSOT in particular may address a number of challenges for surgical procedures by providing real-time visualization below the tissue surface. In particular, optoacoustic imaging can provide immediate information on the perfusion status of tissues based on analysis of hemoglobin dynamics and oxygenation. This may, for example, detect areas at high risk of anastomotic leakage under ischemic conditions in the colon or esophagus, allowing preventive measures to be taken. [2]

Possible use for biopsy-free detection of lymph node metastasis

MSOT can detect exogenous contrast agents up to a depth of 5 cm in tissue if the overlaying tissue is sufficiently compressed. It has been evaluated on 500 removed lymph nodes to check for melanin as a sign of melanoma metastasis. [22]

See also

Related Research Articles

<span class="mw-page-title-main">Optical coherence tomography</span> Imaging technique

Optical coherence tomography (OCT) is an imaging technique that uses interferometry with short-coherence-length light to obtain micrometer-level depth resolution and uses transverse scanning of the light beam to form two- and three-dimensional images from light reflected from within biological tissue or other scattering media. Short-coherence-length light can be obtained using a superluminescent diode (SLD) with a broad spectral bandwidth or a broadly tunable laser with narrow linewidth. The first demonstration of OCT imaging was published by a team from MIT and Harvard Medical School in a 1991 article in the journal Science. The article introduced the term "OCT" to credit its derivation from optical coherence-domain reflectometry, in which the axial resolution is based on temporal coherence. The first demonstrations of in vivo OCT imaging quickly followed.

<span class="mw-page-title-main">Near-infrared spectroscopy</span> Analytical method

Near-infrared spectroscopy (NIRS) is a spectroscopic method that uses the near-infrared region of the electromagnetic spectrum. Typical applications include medical and physiological diagnostics and research including blood sugar, pulse oximetry, functional neuroimaging, sports medicine, elite sports training, ergonomics, rehabilitation, neonatal research, brain computer interface, urology, and neurology. There are also applications in other areas as well such as pharmaceutical, food and agrochemical quality control, atmospheric chemistry, combustion research and knowledge.

Computed tomography laser mammography (CTLM) is the trademark of Imaging Diagnostic Systems, Inc. for its optical tomographic technique for female breast imaging.

<span class="mw-page-title-main">Photoacoustic imaging</span> Imaging using the photoacoustic effect

Photoacoustic imaging or optoacoustic imaging is a biomedical imaging modality based on the photoacoustic effect. Non-ionizing laser pulses are delivered into biological tissues and part of the energy will be absorbed and converted into heat, leading to transient thermoelastic expansion and thus wideband ultrasonic emission. The generated ultrasonic waves are detected by ultrasonic transducers and then analyzed to produce images. It is known that optical absorption is closely associated with physiological properties, such as hemoglobin concentration and oxygen saturation. As a result, the magnitude of the ultrasonic emission, which is proportional to the local energy deposition, reveals physiologically specific optical absorption contrast. 2D or 3D images of the targeted areas can then be formed.

<span class="mw-page-title-main">Functional near-infrared spectroscopy</span> Optical technique for monitoring brain activity

Functional near-infrared spectroscopy (fNIRS) is an optical brain monitoring technique which uses near-infrared spectroscopy for the purpose of functional neuroimaging. Using fNIRS, brain activity is measured by using near-infrared light to estimate cortical hemodynamic activity which occur in response to neural activity. Alongside EEG, fNIRS is one of the most common non-invasive neuroimaging techniques which can be used in portable contexts. The signal is often compared with the BOLD signal measured by fMRI and is capable of measuring changes both in oxy- and deoxyhemoglobin concentration, but can only measure from regions near the cortical surface. fNIRS may also be referred to as Optical Topography (OT) and is sometimes referred to simply as NIRS.

<span class="mw-page-title-main">Molecular imaging</span> Imaging molecules within living patients

Molecular imaging is a field of medical imaging that focuses on imaging molecules of medical interest within living patients. This is in contrast to conventional methods for obtaining molecular information from preserved tissue samples, such as histology. Molecules of interest may be either ones produced naturally by the body, or synthetic molecules produced in a laboratory and injected into a patient by a doctor. The most common example of molecular imaging used clinically today is to inject a contrast agent into a patient's bloodstream and to use an imaging modality to track its movement in the body. Molecular imaging originated from the field of radiology from a need to better understand fundamental molecular processes inside organisms in a noninvasive manner.

<span class="mw-page-title-main">Thermoacoustic imaging</span>

Thermoacoustic imaging was originally proposed by Theodore Bowen in 1981 as a strategy for studying the absorption properties of human tissue using virtually any kind of electromagnetic radiation. But Alexander Graham Bell first reported the physical principle upon which thermoacoustic imaging is based a century earlier. He observed that audible sound could be created by illuminating an intermittent beam of sunlight onto a rubber sheet. Shortly after Bowen's work was published, other researchers proposed methodology for thermoacoustic imaging using microwaves. In 1994 researchers used an infrared laser to produce the first thermoacoustic images of near-infrared optical absorption in a tissue-mimicking phantom, albeit in two dimensions (2D). In 1995 other researchers formulated a general reconstruction algorithm by which 2D thermoacoustic images could be computed from their "projections," i.e. thermoacoustic computed tomography (TCT). By 1998 researchers at Indiana University Medical Center extended TCT to 3D and employed pulsed microwaves to produce the first fully three-dimensional (3D) thermoacoustic images of biologic tissue [an excised lamb kidney ]. The following year they created the first fully 3D thermoacoustic images of cancer in the human breast, again using pulsed microwaves. Since that time, thermoacoustic imaging has gained widespread popularity in research institutions worldwide. As of 2008, three companies were developing commercial thermoacoustic imaging systems – Seno Medical, Endra, Inc. and OptoSonics, Inc.

The photoacoustic Doppler effect is a type of Doppler effect that occurs when an intensity modulated light wave induces a photoacoustic wave on moving particles with a specific frequency. The observed frequency shift is a good indicator of the velocity of the illuminated moving particles. A potential biomedical application is measuring blood flow.

Ultrasound-modulated optical tomography (UOT), also known as Acousto-Optic Tomography (AOT), is a hybrid imaging modality that combines light and sound; it is a form of tomography involving ultrasound. It is used in imaging of biological soft tissues and has potential applications for early cancer detection. As a hybrid modality which uses both light and sound, UOT provides some of the best features of both: the use of light provides strong contrast and sensitivity ; these two features are derived from the optical component of UOT. The use of ultrasound allows for high resolution, as well as a high imaging depth. However, the difficulty of tackling the two fundamental problems with UOT have caused UOT to evolve relatively slowly; most work in the field is limited to theoretical simulations or phantom / sample studies.

The near-infrared (NIR) window defines the range of wavelengths from 650 to 1350 nanometre (nm) where light has its maximum depth of penetration in tissue. Within the NIR window, scattering is the most dominant light-tissue interaction, and therefore the propagating light becomes diffused rapidly. Since scattering increases the distance travelled by photons within tissue, the probability of photon absorption also increases. Because scattering has weak dependence on wavelength, the NIR window is primarily limited by the light absorption of blood at short wavelengths and water at long wavelengths. The technique using this window is called NIRS. Medical imaging techniques such as fluorescence image-guided surgery often make use of the NIR window to detect deep structures.

Preclinical imaging is the visualization of living animals for research purposes, such as drug development. Imaging modalities have long been crucial to the researcher in observing changes, either at the organ, tissue, cell, or molecular level, in animals responding to physiological or environmental changes. Imaging modalities that are non-invasive and in vivo have become especially important to study animal models longitudinally. Broadly speaking, these imaging systems can be categorized into primarily morphological/anatomical and primarily molecular imaging techniques. Techniques such as high-frequency micro-ultrasound, magnetic resonance imaging (MRI) and computed tomography (CT) are usually used for anatomical imaging, while optical imaging, positron emission tomography (PET), and single photon emission computed tomography (SPECT) are usually used for molecular visualizations.

<span class="mw-page-title-main">Diffuse optical imaging</span>

Diffuse optical imaging (DOI) is a method of imaging using near-infrared spectroscopy (NIRS) or fluorescence-based methods. When used to create 3D volumetric models of the imaged material DOI is referred to as diffuse optical tomography, whereas 2D imaging methods are classified as diffuse optical imaging.

Super-resolution photoacoustic imaging is a set of techniques used to enhance spatial resolution in photoacoustic imaging. Specifically, these techniques primarily break the optical diffraction limit of the photoacoustic imaging system. It can be achieved in a variety of mechanisms, such as blind structured illumination, multi-speckle illumination, or photo-imprint photoacoustic microscopy in Figure 1.

<span class="mw-page-title-main">Photoacoustic microscopy</span>

Photoacoustic microscopy is an imaging method based on the photoacoustic effect and is a subset of photoacoustic tomography. Photoacoustic microscopy takes advantage of the local temperature rise that occurs as a result of light absorption in tissue. Using a nanosecond pulsed laser beam, tissues undergo thermoelastic expansion, resulting in the release of a wide-band acoustic wave that can be detected using a high-frequency ultrasound transducer. Since ultrasonic scattering in tissue is weaker than optical scattering, photoacoustic microscopy is capable of achieving high-resolution images at greater depths than conventional microscopy methods. Furthermore, photoacoustic microscopy is especially useful in the field of biomedical imaging due to its scalability. By adjusting the optical and acoustic foci, lateral resolution may be optimized for the desired imaging depth.

Vasilis Ntziachristos is a Greek American biomedical engineer, scientist, and inventor best known for his development of fundamental and translational research tools for imaging tissues based on fluorescence and optoacoustics.

Multiple scattering low coherence interferometry (ms/LCI) is an imaging technique that relies on analyzing multiply scattered light in order to capture depth-resolved images from optical scattering media. With current applications primarily in medical imaging, has the advantage of a higher range since forward scattered light attenuates less with depth when compared to the specularly reflected light that is assessed in more conventional imaging methods such as optical coherence tomography. This allows ms/LCI to image through up to 90 mean free scattering paths, compared to roughly 27 scattering MFPs in OCT and 1–2 scattering MFPs in confocal microscopy.

Time-domain diffuse optics or time-resolved functional near-infrared spectroscopy is a branch of functional near-Infrared spectroscopy which deals with light propagation in diffusive media. There are three main approaches to diffuse optics namely continuous wave (CW), frequency domain (FD) and time-domain (TD). Biological tissue in the range of red to near-infrared wavelengths are transparent to light and can be used to probe deep layers of the tissue thus enabling various in vivo applications and clinical trials.

Deep learning in photoacoustic imaging

Deep learning in photoacoustic imaging combines the hybrid imaging modality of photoacoustic imaging (PA) with the rapidly evolving field of deep learning. Photoacoustic imaging is based on the photoacoustic effect, in which optical absorption causes a rise in temperature, which causes a subsequent rise in pressure via thermo-elastic expansion. This pressure rise propagates through the tissue and is sensed via ultrasonic transducers. Due to the proportionality between the optical absorption, the rise in temperature, and the rise in pressure, the ultrasound pressure wave signal can be used to quantify the original optical energy deposition within the tissue.

Diffuse optical mammography, or simply optical mammography, is an emerging imaging technique that enables the investigation of the breast composition through spectral analysis. It combines in a single non-invasive tool the capability to implement breast cancer risk assessment, lesion characterization, therapy monitoring and prediction of therapy outcome. It is an application of diffuse optics, which studies light propagation in strongly diffusive media, such as biological tissues, working in the red and near-infrared spectral range, between 600 and 1100 nm.

Photoacoustic flow cytometry or PAFC is a biomedical imaging modality that utilizes photoacoustic imaging to perform flow cytometry. A flow of cells passes a photoacoustic system producing individual signal response. Each signal is counted to produce a quantitative evaluation of the input sample.

References

  1. 1 2 3 4 5 V. Ntziachristos, D. Razansky, "Molecular imaging by means of multispectral optoacoustic tomography (MSOT)", Chem. Rev. 110 (2010) 2783-2794.
  2. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A. Taruttis, V. Ntziachristos, "Advances in real-time multispectral optoacoustic imaging and its applications", Nat Photon 9 (2015) 219-227.
  3. W. Assmann, S. Kellnberger, S. Reinhardt, S. Lehrack, A. Edlich, P.G. Thirolf, M. Moser, G. Dollinger, M. Omar, V. Ntziachristos, K. Parodi, "Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy", Med. Phys. 42 (2015) 567-574.
  4. D. Razansky, S. Kellnberger, V. Ntziachristos, "Near-field radiofrequency thermoacoustic tomography with impulse excitation", Med. Phys. 37 (2010) 4602-4607.
  5. K. Stephan, H. Amir, R. Daniel, N. Vasilis, "Near-field thermoacoustic tomography of small animals", Phys. Med. Biol. 56 (2011) 3433.
  6. L.V. Wang, S. Hu, "Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs", Science 335 (2012) 1458-1462.
  7. A. Taruttis, M. Wildgruber, K. Kosanke, N. Beziere, K. Licha, R. Haag, M. Aichler, A. Walch, E. Rummeny, V. Ntziachristos, "Multispectral optoacoustic tomography of myocardial infarction", Photoacoustics 1 (2013) 3-8.
  8. B. Wang, E. Yantsen, T. Larson, A.B. Karpiouk, S. Sethuraman, J.L. Su, K. Sokolov, S.Y. Emelianov, "Plasmonic Intravascular Photoacoustic Imaging for Detection of Macrophages in Atherosclerotic Plaques", Nano Lett. 9 (2009) 2212-2217.
  9. 1 2 3 N.C. Burton, M. Patel, S. Morscher, W.H.P. Driessen, J. Claussen, N. Beziere, T. Jetzfellner, A. Taruttis, D. Razansky, B. Bednar, V. Ntziachristos, "Multispectral Opto-acoustic Tomography (MSOT) of the Brain and Glioblastoma Characterization", Neuroimage 65 (2013) 522-528.
  10. J. Yao, J. Xia, K.I. Maslov, M. Nasiriavanaki, V. Tsytsarev, A.V. Demchenko, L.V. Wang, "Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo", Neuroimage 64 (2013) 257-266.
  11. L. Xiang, L. Ji, T. Zhang, B. Wang, J. Yang, Q. Zhang, M.S. Jiang, J. Zhou, P.R. Carney, H. Jiang, "Noninvasive real time tomographic imaging of epileptic foci and networks", Neuroimage 66 (2013) 240-248.
  12. S. Gottschalk, T. Felix Fehm, X. Luís Deán-Ben, D. Razansky, "Noninvasive real-time visualization of multiple cerebral hemodynamic parameters in whole mouse brains using five-dimensional optoacoustic tomography", J. Cereb. Blood Flow Metab. 35 (2015) 531-535.
  13. E. Herzog, A. Taruttis, N. Beziere, A.A. Lutich, D. Razansky, V. Ntziachristos, "Optical Imaging of Cancer Heterogeneity with Multispectral Optoacoustic Tomography", Radiology 263 (2012) 461-468.
  14. J. Laufer, P. Johnson, E. Zhang, B. Treeby, B. Cox, B. Pedley, P. Beard, "In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy", J. Biomed. Opt. 17 (2012).
  15. Q. Ruan, L. Xi, S.L. Boye, S. Han, Z.J. Chen, W.W. Hauswirth, A.S. Lewin, M.E. Boulton, B.K. Law, W.G. Jiang, H. Jiang, J. Cai, "Development of an anti-angiogenic therapeutic model combining scAAV2-delivered siRNAs and noninvasive photoacoustic imaging of tumor vasculature development", Cancer Lett. 332 (2013) 120-129.
  16. 1 2 3 4 A. Buehler, M. Kacprowicz, A. Taruttis, V. Ntziachristos, "Real-time handheld multispectral optoacoustic imaging", Opt. Lett. 38 (2013) 1404-1406.
  17. M. Heijblom, D. Piras, M. Brinkhuis, J.C.G. van Hespen, F.M. van den Engh, M. van der Schaaf, J.M. Klaase, T.G. van Leeuwen, W. Steenbergen, S. Manohar, "Photoacoustic image patterns of breast carcinoma and comparisons with Magnetic Resonance Imaging and vascular stained histopathology", Scientific Reports 5 (2015) 11778.
  18. S. Manohar, A. Kharine, J.C.G. van Hespen, W. Steenbergen, T.G. van Leeuwen, "The Twente Photoacoustic Mammoscope: system overview and performance", Phys. Med. Biol. 50 (2005) 2543-2557.
  19. 1 2 S. Manohar, S.E. Vaartjes, J.C.G.v. Hespen, J.M. Klaase, F.M.v.d. Engh, W. Steenbergen, T.G.v. Leeuwen, "Initial results of in vivo non-invasive cancer imaging in the human breast using near-infrared photoacoustics", Opt. Express 15 (2007) 12277-12285.
  20. 1 2 3 A. Taruttis, A.C. Timmermans, P.C. Wouters, M. Kacprowicz, G.M. van Dam, V. Ntziachristos, "Optoacoustic Imaging of Human Vasculature: Feasibility by Using a Handheld Probe", Radiology (2016) 152160.
  21. H.F. Zhang, K. Maslov, M.L. Li, G. Stoica, L.H.V. Wang, "In vivo volumetric imaging of subcutaneous microvasculature by photoacoustic microscopy", Opt. Express 14 (2006) 9317-9323.
  22. 1 2 3 I. Stoffels, S. Morscher, I. Helfrich, U. Hillen, J. Lehy, N.C. Burton, T.C.P. Sardella, J. Claussen, T.D. Poeppel, H.S. Bachmann, A. Roesch, K. Griewank, D. Schadendorf, M. Gunzer, J. Klode, "Metastatic status of sentinel lymph nodes in melanoma determined noninvasively with multispectral optoacoustic imaging", Science Translational Medicine 7 (2015).
  23. 1 2 M. Schwarz, A. Buehler, J. Aguirre, V. Ntziachristos, "Three-dimensional multispectral optoacoustic mesoscopy reveals melanin and blood oxygenation in human skin in vivo", Journal of biophotonics 9 (2016) 55-60.
  24. B. Zabihian, J. Weingast, M. Liu, E. Zhang, P. Beard, H. Pehamberger, W. Drexler, B. Hermann, "In vivo dual-modality photoacoustic and optical coherence tomography imaging of human dermatological pathologies", Biomed Opt Express 6 (2015) 3163-3178.
  25. P. Beard, "Biomedical photoacoustic imaging", Interface Focus 1 (2011) 602-631.
  26. P. Mohajerani, S. Kellnberger, V. Ntziachristos, "Frequency domain optoacoustic tomography using amplitude and phase", Photoacoustics 2 (2014) 111-118.
  27. S. Kellnberger, N.C. Deliolanis, D. Queirós, G. Sergiadis, V. Ntziachristos, "In vivo frequency domain optoacoustic tomography", Opt. Lett. 37 (2012) 3423-3425.
  28. H.P. Brecht, R. Su, M. Fronheiser, S.A. Ermilov, A. Conjusteau, A.A. Oraevsky, "Whole-body three-dimensional optoacoustic tomography system for small animals", J. Biomed. Opt. 14 (2009) 064007.
  29. R.A. Kruger, R.B. Lam, D.R. Reinecke, S.P. Del Rio, R.P. Doyle, "Photoacoustic angiography of the breast", Med. Phys. 37 (2010) 6096-6100.
  30. 1 2 X.L. Deán-Ben, D. Razansky, "Adding fifth dimension to optoacoustic imaging: volumetric time-resolved spectrally enriched tomography", Light: Science & Applications 3 (2014).
  31. A. Buehler, E. Herzog, D. Razansky, V. Ntziachristos, "Video rate optoacoustic tomography of mouse kidney perfusion", Opt. Lett. 35 (2010) 2475-2477.
  32. D. Razansky, A. Buehler, V. Ntziachristos, "Volumetric real-time multispectral optoacoustic tomography of biomarkers", Nat. Protoc. 6 (2011) 1121-1129.
  33. E. Mercep, N.C. Burton, J. Claussen, D. Razansky, «Whole-body live mouse imaging by hybrid reflection-mode ultrasound and optoacoustic tomography», Opt Lett. 40 (2015)4643-4646.
  34. A.P. Jathoul, J. Laufer, O. Ogunlade, B. Treeby, B. Cox, E. Zhang, P. Johnson, A.R. Pizzey, B. Philip, T. Marafioti, M.F. Lythgoe, R.B. Pedley, M.A. Pule, P. Beard, Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter, Nat Photon 9 (2015) 239-246.
  35. J. Stritzker, L. Kirscher, M. Scadeng, N.C. Deliolanis, S. Morscher, P. Symvoulidis, K. Schaefer, Q. Zhang, L. Buckel, M. Hess, U. Donat, W.G. Bradley, V. Ntziachristos, A.A. Szalay, "Vaccinia virus-mediated melanin production allows MR and optoacoustic deep tissue imaging and laser-induced thermotherapy of cancer", Proc. Natl. Acad. Sci. U. S. A. 110 (2013) 3316-3320.
  36. 1 2 3 S. Tzoumas, A. Nunes, I. Olefir, S. Stangl, P. Symvoulidis, S. Glasl, C. Bayer, G. Multhoff, V. Ntziachristos, "Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues", Nature Communications 7 (2016) 12121.
  37. 1 2 3 L.V. Wang, "Multiscale photoacoustic microscopy and computed tomography", Nat Photonics 3 (2009) 503-509.
  38. G.J. Tserevelakis, D. Soliman, M. Omar, V. Ntziachristos, "Hybrid multiphoton and optoacoustic microscope", Opt. Lett. 39 (2014) 1819-1822.
  39. B. Cox, J.G. Laufer, S.R. Arridge, P.C. Beard, "Quantitative spectroscopic photoacoustic imaging: a review", J. Biomed. Opt. 17 (2012).
  40. N. Beziere, V. Ntziachristos, "Optoacoustic Imaging of Naphthalocyanine: Potential for Contrast Enhancement and Therapy Monitoring", J. Nucl. Med. 56 (2015) 323-328.
  41. R.A. Kruger, W.L. Kiser, D.R. Reinecke, G.A. Kruger, K.D. Miller, "Thermoacoustic molecular imaging of small animals", Molecular imaging 2 (2003) 113-123.
  42. D. Razansky, J. Baeten, V. Ntziachristos, "Sensitivity of molecular target detection by multispectral optoacoustic tomography (MSOT)", Med. Phys. 36 (2009) 939-945.
  43. 1 2 S. Tzoumas, N.C. Deliolanis, S. Morscher, V. Ntziachristos, "Unmixing Molecular Agents From Absorbing Tissue in Multispectral Optoacoustic Tomography", IEEE Trans. Med. Imaging 33 (2014) 48-60.
  44. S. Tzoumas, A. Kravtsiv, Y. Gao, A. Buehler, V. Ntziachristos, "Statistical molecular target detection framework for multispectral optoacoustic tomography", IEEE Trans. Med. Imaging PP (2016) 1-1.
  45. V. Ntziachristos, "Going deeper than microscopy: the optical imaging frontier in biology", Nat Meth 7 (2010) 603-614.
  46. H.F. Zhang, K. Maslov, G. Stoica, L.V. Wang, "Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging", Nat Biotech 24 (2006) 848-851.
  47. E.I. Galanzha, E.V. Shashkov, P.M. Spring, J.Y. Suen, V.P. Zharov, "In vivo, Noninvasive, Label-Free Detection and Eradication of Circulating Metastatic Melanoma Cells Using Two-Color Photoacoustic Flow Cytometry with a Diode Laser", Cancer Res. 69 (2009) 7926-7934.
  48. 1 2 3 4 5 6 7 8 9 10 A. Taruttis, G.M. van Dam, V. Ntziachristos, "Mesoscopic and macroscopic optoacoustic imaging of cancer", Cancer Res. 75 (2015) 1548-1559.
  49. D.-K. Yao, K. Maslov, K.K. Shung, Q. Zhou, L.V. Wang, "In vivo label-free photoacoustic microscopy of cell nuclei by excitation of DNA and RNA", Opt. Lett. 35 (2010) 4139-4141.
  50. C. Kim, K.H. Song, F. Gao, L.V. Wang, "Sentinel Lymph Nodes and Lymphatic Vessels: Noninvasive Dual-Modality in Vivo Mapping by Using Indocyanine Green in Rats—Volumetric Spectroscopic Photoacoustic Imaging and Planar Fluorescence Imaging", Radiology 255 (2010) 442-450.
  51. C.J.H. Ho, G. Balasundaram, W. Driessen, R. McLaren, C.L. Wong, U.S. Dinish, A.B.E. Attia, V. Ntziachristos, M. Olivo, "Multifunctional Photosensitizer-Based Contrast Agents for Photoacoustic Imaging", Scientific Reports 4 (2014) 5342.
  52. M. Eghtedari, A. Oraevsky, J.A. Copland, N.A. Kotov, A. Conjusteau, M. Motamedi, "High Sensitivity of In Vivo Detection of Gold Nanorods Using a Laser Optoacoustic Imaging System", Nano Lett. 7 (2007) 1914-1918.
  53. K.A. Homan, M. Souza, R. Truby, G.P. Luke, C. Green, E. Vreeland, S. Emelianov, "Silver Nanoplate Contrast Agents for in Vivo Molecular Photoacoustic Imaging", ACS Nano 6 (2012) 641-650.
  54. A. De La Zerda, C. Zavaleta, S. Keren, S. Vaithilingam, S. Bodapati, Z. Liu, J. Levi, B.R. Smith, T.-J. Ma, O. Oralkan, Z. Cheng, X. Chen, H. Dai, B.T. Khuri-Yakub, S.S. Gambhir, "Carbon nanotubes as photoacoustic molecular imaging agents in living mice", Nat Nano 3 (2008) 557-562.
  55. A. Hellebust, R. Richards-Kortum, "Advances in molecular imaging: targeted optical contrast agents for cancer diagnostics", Nanomedicine 7 (2012) 429-445.
  56. M.L. Li, J.T. Oh, X. Xie, G. Ku, W. Wang, C. Li, G. Lungu, G. Stoica, L.V. Wang, "Simultaneous Molecular and Hypoxia Imaging of Brain Tumors In Vivo Using Spectroscopic Photoacoustic Tomography", Proceedings of the IEEE 96 (2008) 481-489.
  57. J. Levi, S.-R. Kothapalli, S. Bohndiek, J.-K. Yoon, A. Dragulescu-Andrasi, C. Nielsen, A. Tisma, S. Bodapati, G. Gowrishankar, X. Yan, C. Chan, D. Starcevic, S.S. Gambhir, "Molecular Photoacoustic Imaging of Follicular Thyroid Carcinoma", Clin. Cancer Res. 19 (2013) 1494-1502.
  58. 1 2 D. Razansky, M. Distel, C. Vinegoni, R. Ma, N. Perrimon, R.W. Koester, V. Ntziachristos, "Multispectral opto-acoustic tomography of deep-seated fluorescent proteins in vivo", Nat Photonics 3 (2009) 412-417.
  59. A. Krumholz, D.M. Shcherbakova, J. Xia, L.V. Wang, V.V. Verkhusha, "Multicontrast photoacoustic in vivo imaging using near-infrared fluorescent proteins", Scientific Reports 4 (2014) 3939.
  60. R.J. Paproski, A. Heinmiller, K. Wachowicz, R.J. Zemp, "Multi-wavelength photoacoustic imaging of inducible tyrosinase reporter gene expression in xenograft tumors", Sci Rep 4 (2014) 5329.
  61. A. Taruttis, S. Morscher, N.C. Burton, D. Razansky, V. Ntziachristos, "Fast Multispectral Optoacoustic Tomography (MSOT) for Dynamic Imaging of Pharmacokinetics and Biodistribution in Multiple Organs", PLoS ONE 7 (2012).
  62. S.A. Ermilov, T. Khamapirad, A. Conjusteau, M.H. Leonard, R. Lacewell, K. Mehta, T. Miller, A.A. Oraevsky, "Laser optoacoustic imaging system for detection of breast cancer", J Biomed Opt 14 (2009) 024007.
  63. M. Heijblom, D. Piras, W. Xia, J.C.G. van Hespen, J.M. Klaase, F.M. van den Engh, T.G. van Leeuwen, W. Steenbergen, S. Manohar, "Visualizing breast cancer using the Twente photoacoustic mammoscope: What do we learn from twelve new patient measurements?", Opt. Express 20 (2012) 11582-11597.
  64. A. Dima, V. Ntziachristos, "Non-invasive carotid imaging using optoacoustic tomography", Opt. Express 20 (2012) 25044-25057.
  65. C.P. Favazza, O. Jassim, L.A. Cornelius, L.V. Wang, "In vivo photoacoustic microscopy of human cutaneous microvasculature and a nevus", J. Biomed. Opt. 16 (2011) 016015-016015-016016.
  66. J.-M. Yang, C. Favazza, R. Chen, J. Yao, X. Cai, K. Maslov, Q. Zhou, K.K. Shung, L.V. Wang, "Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo", Nat. Med. 18 (2012) 1297-+.
  67. J.-M. Yang, K. Maslov, H.-C. Yang, Q. Zhou, K.K. Shung, L.V. Wang, "Photoacoustic endoscopy", Opt. Lett. 34 (2009) 1591-1593.
  68. T.-J. Yoon, Y.-S. Cho, "Recent advances in photoacoustic endoscopy", World journal of gastrointestinal endoscopy 5 (2013) 534-539.
  69. A.B. Karpiouk, B. Wang, S.Y. Emelianov, "Development of a catheter for combined intravascular ultrasound and photoacoustic imaging", Rev. Sci. Instrum. 81 (2010).
  70. S. Sethuraman, S.R. Aglyamov, J.H. Amirian, R.W. Smalling, S.Y. Emelianov, "Intravascular photoacoustic imaging using an IVUS imaging catheter", IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 54 (2007) 978-986.
  71. B. Wang, J.L. Su, A.B. Karpiouk, K.V. Sokolov, R.W. Smalling, S.Y. Emelianov, "Intravascular Photoacoustic Imaging", IEEE J. Sel. Topics Quantum Electron 16 (2010) 588-599.